This study aims to analyze the spatio-temporal variability of the characteristics of water resources in the Diani watershed,located in the southeast of the Republic of Guinea.The objective is to assess the availabilit...This study aims to analyze the spatio-temporal variability of the characteristics of water resources in the Diani watershed,located in the southeast of the Republic of Guinea.The objective is to assess the availability and quantity of water for sustainable management of this essential resource.The results obtained show a slight variability of hydro-climatic parameters.The most remarkable wet periods by their intensity of(1982-1998)and(2005-2012)are moderate and that of 1986-1990 is extremely severe during which they are felt on all the stations of the South of Guinea.In addition,the dry years,the end of 1970 and 1980 to 1987 recognized by the WMO(World Meteorological Organization)as drought years were highlighted in the Diani watershed in the South of the Republic of Guinea.展开更多
This prospective survey was conducted from February to December 2014 about the use ceftriaxone (ceftriaz) for antibioprophylaxy concerning 300 patients by the surgery staff in the Gabriel Touré Teaching Hospital ...This prospective survey was conducted from February to December 2014 about the use ceftriaxone (ceftriaz) for antibioprophylaxy concerning 300 patients by the surgery staff in the Gabriel Touré Teaching Hospital in Mali. The quantity of drug used was based on the weight of the patient. One dose was administrated in intravenous at the anesthesiology induction time. For more than 2 hours of intervention time, 4 (1.3%) patients received a second dose. The majority of cases (189, 63%) were out of emergency (emergency cases—111, 37%). The mean age was 41.6 years (range: 3 - 95 years). The patients were classed Altmeir II 203 (67.7%) and Altmeir I 97 (32.3%). The NNISS score 0 concerned 101 (33.6%) and NNISS 1 in 180 (60%) patients. The factors of risky were anemia (38;12.7%), diabetes (6;2%), and HIV (3;1%). The mean of intervention duration was 56.8?±?27.5 minutes. Four cases of intervention site infection were encountered caused by?Pseudomonas?aeruginosa?in 2 patients;?Escherichia coli?(1 case), and?Staphylococcus aureus?(1 case). Conclusion: Antibioprohylaxy is not the only way to prevent infections but it stays necessary. The respect of hygien and aseptic measures should be used to reduce the rate of intervention site infection.展开更多
The operating site infections constitute the major postoperative issue in surgery. Our objectives were to determine the hospital frequency, the risk factors, the involved germs as well as the cost generated by the ope...The operating site infections constitute the major postoperative issue in surgery. Our objectives were to determine the hospital frequency, the risk factors, the involved germs as well as the cost generated by the operating site infections. Method: Our three months prospective survey run from September the 1st to November the 30th 2013 has included all department patients being operated on and hospitalized. The criteria have been set by CDC d’Atlanta. Results: 374 files were involved, among them 229 (61.2%) were emergencies and 145 (38.8%) were scheduled. The average age was 41 (extremes 7 and 95 standard deviation 17.46), the sex ratio 1.67. The infective risk according to Altmeier has found 17.5% type 1, 25.1% type 2, 11.2% type 3 and 46.3% type 4;according to NNISS, 96 (25.7) were NNISS 0;94 (51.9%) NNISS 1;80 (21.4%) NNISS 2;and 4 (1.1%) NNISS. In the Altmeier class I have not got antibiotic before infection signs appearances. Our overall rate of operating site infections was 7.9% (29 cases), with 24 (82.8%) emergency cases. According to Altmeier’s class of infective risk, the rate of operating site infections was 1.54% making 1 out of 65 type I patients;4.3% making 4 out of 93 type II patients;11.9% making 5 out of 42 type III patients;10.9% making 19 out of 174 type IV patients. According to NNISS, the infective risk has been assessed and was 2.08% for score 0, we have got 8.25% score 1, and 12.5% for score 2, and 25% for score 3. The bacteriology has been dominated by Escherichia colii(51.7), Proteus mirabilisi(13.8), and Klebsiella pneumoniaei(10.34). The germs have been resistant to the combination Amoxicillin-clavulanic Acid between 50% and 87% of cases. The most active antibiotics on the germs have been Cephalosporin, Polypeptides, and aminoglycosides. The hospital stay has been delayed to 12 days on average by operating site infections, making 2.5 times greater than those uninfected. The infection has increased the cost of management around 600 Euro.展开更多
This study is a continuation of our research work on the energy recovery of OM(Organic Matter)and the protection of the environment.It took place from October 1 to November 25,2021 in the poultry farm of Mr.Elhadj Day...This study is a continuation of our research work on the energy recovery of OM(Organic Matter)and the protection of the environment.It took place from October 1 to November 25,2021 in the poultry farm of Mr.Elhadj Daye KABA in the Senkefra district,urban commune of Kankan.During this work,we designed,built and tested a 6 m^(3)biodigester.Cow dung(2,500 kg)with 2,300 L of water served as a substrate for the production of biogas during 30 days of digestion.The following physico-chemical parameters:Temperature(T°C),Humidity(H%),Hydrogen potential(pH),Dry Matter(DM),Organic Matter(OM)and the ratio between Carbon(C)and Nitrogen(N)(C/N)of cow dung were determined,namely:T(28°);H(75%);pH(6.5);MS(15%);MO(55%)and C/N(25%).During the 30 days of digestion,the temperature varied from 27 to 35°C with an average of 30.57°C(mesophilic digestion);the pH varied from 6 to 9,with an average of 7.58;the daily production kinetics represented the four stages of digestion(hydrolysis,acidogenesis,acetogenesis and methanogenesis).The cumulative production of biogas is 198 m^(3).The composition of the biogas produced is 60%CH_(4),36%CO_(2),2%N_(2),2%H_(2)S and 1.5%H2.The biogas produced was used for lighting,water heating and cooking.These results show that the biogas produced is of good quality and remains consistent with the literature.展开更多
In order to increase the available power of the electrical energy distribution station and improve the voltage profile of the distribution lines, the use of shunt capacitor banks is indicated. The main results obtaine...In order to increase the available power of the electrical energy distribution station and improve the voltage profile of the distribution lines, the use of shunt capacitor banks is indicated. The main results obtained during this study are: a reduction in subscribed power from 14913.978 kVA to 14010.100 kVA, a reduction in the transformer load rate from 99.4% to 93.4%, a reduction in reactive power called from 5481.729 kVAr to 481.729 kVAr, an increase in the active power transported by the substation from 8505.062 kW to 8962.323 kW, a reduction in the voltage drop from 4.8% to 3.9%, an increase in the power available at the secondary of the transformer station at full load from 13950 kW to 14700 kW and an annual electrical energy saving of 339943.48 kWh of electrical energy, therefore fuel savings and a reduction in CO<sub>2</sub> and SO<sub>2</sub> emissions due to this energy saving will be achieved. The installation of capacitor banks for optimization of reactive energy allowed a reduction in the current called therefore a reduction in the absorbed power: 14153.061 kVA, i.e. a reduction of 903.876 kVA. It is therefore essential that energy players are convinced of the need to install capacitors to reduce or even eliminate their reactive energy bill. This is necessarily accompanied by an investment by Electricité De Guinée by setting up active and reactive energy meters but also by implementing pricing in line with the reduction in the transfer of reactive energy in the network.展开更多
This study was carried out at the Mamou Higher Institute of Technology during the period from March 10 to April 15, 2022, with the aim of designing and testing a solar dryer with forced convection by drying potatoes. ...This study was carried out at the Mamou Higher Institute of Technology during the period from March 10 to April 15, 2022, with the aim of designing and testing a solar dryer with forced convection by drying potatoes. The dryer was designed using local materials. Its main geometric parameters are: 1) height of the drying chamber (90 cm), 2) length of the drying chamber (50 cm), 3) width of the drying chamber (43 cm), 4) surface of the racks (0.1806 m<sup>2</sup>), 5) surface of the heat accumulator (0.2537 m<sup>2</sup>). The experiment focused on the vacuum test of the dryer for two days and that of the drying of the sweet potato for three days from 8:30 a.m. to 5:30 p.m. The average vacuum test temperature values of the three environments are respectively accumulator (43°C), dryer chamber (41°C) and ambient environment (34°C). Four kilograms (4 kg) of boiled sweet potato were dried. The average temperatures in the accumulator and in the drying chamber during the three days of drying are respectively 33°C and 39°C. The final mass of the dried product is 1.2 kg, with a quantity of water extracted of 2 liters or 63% of the initial mass of the product. The average drying rate is 0.074 kg/h. The drying kinetics showed a decreasing rate in the absence of the heating period and the constant rate period.展开更多
In the town of Mamou,all homes with sanitation systems are equipped with autonomous installations not connected to a sewer network.The emptying service is provided by manual emptiers and by the living environment and ...In the town of Mamou,all homes with sanitation systems are equipped with autonomous installations not connected to a sewer network.The emptying service is provided by manual emptiers and by the living environment and sanitation service of the urban municipality which has a single 6 m^(3)truck.The objective of this work is to determine the quantity of fecal sludge produced within the city for sustainable management.The methodology adopted is based on a field survey and the use of three methods for evaluating the quantities of sludge(specific production,quantity of sludge collected by the sludge truck and the total production of sludge produced in the various sludge works).The results obtained show that,out of the 2,940 sanitation works identified,2,936 works have been emptied at least once since their construction.Then 2,307 structures are emptied manually or 78.57%,against;619 structures emptied mechanically or 21.08%.The structures are emptied on average every 3 years for septic tanks and every 5 years for dry latrines.The specific production of sludge is 685,241,532 m^(3)/year;the production of sludge by the mechanical emptying technique varies from 588,641.57 m^(3)/year to 724,800.46 m^(3)/year and the production of sludge by manual emptying is 1,573,709.33 m^(3)/year,for a total quantity of sludge produced including between 2,162,350 m^(3)/year to 685,241,531.9 m^(3)/year.展开更多
This article describes the design and creation of a remote monitoring and control system based on GSM(Global System for Mobile)communications technology for monitoring the key parameters of a biodigester.Biodigesters ...This article describes the design and creation of a remote monitoring and control system based on GSM(Global System for Mobile)communications technology for monitoring the key parameters of a biodigester.Biodigesters are widely used for the conversion of organic materials into biogas,thereby contributing to renewable energy production and organic waste management.However,real-time monitoring and regulation of parameters such as temperature,humidity,product gas level,pH are essential to ensure the efficiency and safety of the digestion process.We created the device for remote control of the operating parameters of the biodigester using an Arduino card,a DHT11 sensor,a pH sensor,a GSM module and a 2×16 LCD(Liquide-Crystal-Display)display.A biodigester(4.5 L plastic container)and accessories were used.The experimental device created made it possible to remotely monitor the evolution of the temperature,humidity,the gas produced as well as the pH in the digester loaded with cow dung,for 45 days.Examination of the real-time evolution of the parameters measured by the device produced showed the same results as those carried out locally by the usual instruments,with a correlation coefficient of around 98%.During this digestion period,the temperature provided by the sensor varied from 25°C to 37°C(mesophilic mode)and the humidity levels varied from 70%to 95%.The results obtained show the reliability of the device produced.This research represents a significant advance in the management of biodigestion facilities.It offers a powerful tool to maximize biogas production,reduce maintenance costs,minimize environmental impact and contribute to the transition to cleaner,renewable energy.展开更多
This research,carried out during September and October 2020 in the city of Kankan,made it possible to take stock of the city’s household waste management.The quantities of waste from the four main landfills in the ci...This research,carried out during September and October 2020 in the city of Kankan,made it possible to take stock of the city’s household waste management.The quantities of waste from the four main landfills in the city are assessed,namely:Sogbè(1350.3 m^(3)),Station(195.5 m^(3)),Station University of Kankan(2491.5 m^(3))and Salamani(369.6 m^(3)).Waste from three landfills/dumps was characterized for 26 days.This characterization covered 5,010.6 kg of waste,composed of 4263.9 kg of organic matter,462.1 kg of recyclable matter and 284.6 kg of inorganic matter.The survey concerned a target population of 403 inhabitants,which made it possible to determine a production ratio per habitant per day of(0.48 kg/habitant/d).Finally,a composting experiment of 2000 kg of organic matter was carried out.The results obtained during this study constitute the basic elements allowing defining a better policy of management of household solid waste in the city of Kankan.展开更多
文摘This study aims to analyze the spatio-temporal variability of the characteristics of water resources in the Diani watershed,located in the southeast of the Republic of Guinea.The objective is to assess the availability and quantity of water for sustainable management of this essential resource.The results obtained show a slight variability of hydro-climatic parameters.The most remarkable wet periods by their intensity of(1982-1998)and(2005-2012)are moderate and that of 1986-1990 is extremely severe during which they are felt on all the stations of the South of Guinea.In addition,the dry years,the end of 1970 and 1980 to 1987 recognized by the WMO(World Meteorological Organization)as drought years were highlighted in the Diani watershed in the South of the Republic of Guinea.
文摘This prospective survey was conducted from February to December 2014 about the use ceftriaxone (ceftriaz) for antibioprophylaxy concerning 300 patients by the surgery staff in the Gabriel Touré Teaching Hospital in Mali. The quantity of drug used was based on the weight of the patient. One dose was administrated in intravenous at the anesthesiology induction time. For more than 2 hours of intervention time, 4 (1.3%) patients received a second dose. The majority of cases (189, 63%) were out of emergency (emergency cases—111, 37%). The mean age was 41.6 years (range: 3 - 95 years). The patients were classed Altmeir II 203 (67.7%) and Altmeir I 97 (32.3%). The NNISS score 0 concerned 101 (33.6%) and NNISS 1 in 180 (60%) patients. The factors of risky were anemia (38;12.7%), diabetes (6;2%), and HIV (3;1%). The mean of intervention duration was 56.8?±?27.5 minutes. Four cases of intervention site infection were encountered caused by?Pseudomonas?aeruginosa?in 2 patients;?Escherichia coli?(1 case), and?Staphylococcus aureus?(1 case). Conclusion: Antibioprohylaxy is not the only way to prevent infections but it stays necessary. The respect of hygien and aseptic measures should be used to reduce the rate of intervention site infection.
文摘The operating site infections constitute the major postoperative issue in surgery. Our objectives were to determine the hospital frequency, the risk factors, the involved germs as well as the cost generated by the operating site infections. Method: Our three months prospective survey run from September the 1st to November the 30th 2013 has included all department patients being operated on and hospitalized. The criteria have been set by CDC d’Atlanta. Results: 374 files were involved, among them 229 (61.2%) were emergencies and 145 (38.8%) were scheduled. The average age was 41 (extremes 7 and 95 standard deviation 17.46), the sex ratio 1.67. The infective risk according to Altmeier has found 17.5% type 1, 25.1% type 2, 11.2% type 3 and 46.3% type 4;according to NNISS, 96 (25.7) were NNISS 0;94 (51.9%) NNISS 1;80 (21.4%) NNISS 2;and 4 (1.1%) NNISS. In the Altmeier class I have not got antibiotic before infection signs appearances. Our overall rate of operating site infections was 7.9% (29 cases), with 24 (82.8%) emergency cases. According to Altmeier’s class of infective risk, the rate of operating site infections was 1.54% making 1 out of 65 type I patients;4.3% making 4 out of 93 type II patients;11.9% making 5 out of 42 type III patients;10.9% making 19 out of 174 type IV patients. According to NNISS, the infective risk has been assessed and was 2.08% for score 0, we have got 8.25% score 1, and 12.5% for score 2, and 25% for score 3. The bacteriology has been dominated by Escherichia colii(51.7), Proteus mirabilisi(13.8), and Klebsiella pneumoniaei(10.34). The germs have been resistant to the combination Amoxicillin-clavulanic Acid between 50% and 87% of cases. The most active antibiotics on the germs have been Cephalosporin, Polypeptides, and aminoglycosides. The hospital stay has been delayed to 12 days on average by operating site infections, making 2.5 times greater than those uninfected. The infection has increased the cost of management around 600 Euro.
文摘This study is a continuation of our research work on the energy recovery of OM(Organic Matter)and the protection of the environment.It took place from October 1 to November 25,2021 in the poultry farm of Mr.Elhadj Daye KABA in the Senkefra district,urban commune of Kankan.During this work,we designed,built and tested a 6 m^(3)biodigester.Cow dung(2,500 kg)with 2,300 L of water served as a substrate for the production of biogas during 30 days of digestion.The following physico-chemical parameters:Temperature(T°C),Humidity(H%),Hydrogen potential(pH),Dry Matter(DM),Organic Matter(OM)and the ratio between Carbon(C)and Nitrogen(N)(C/N)of cow dung were determined,namely:T(28°);H(75%);pH(6.5);MS(15%);MO(55%)and C/N(25%).During the 30 days of digestion,the temperature varied from 27 to 35°C with an average of 30.57°C(mesophilic digestion);the pH varied from 6 to 9,with an average of 7.58;the daily production kinetics represented the four stages of digestion(hydrolysis,acidogenesis,acetogenesis and methanogenesis).The cumulative production of biogas is 198 m^(3).The composition of the biogas produced is 60%CH_(4),36%CO_(2),2%N_(2),2%H_(2)S and 1.5%H2.The biogas produced was used for lighting,water heating and cooking.These results show that the biogas produced is of good quality and remains consistent with the literature.
文摘In order to increase the available power of the electrical energy distribution station and improve the voltage profile of the distribution lines, the use of shunt capacitor banks is indicated. The main results obtained during this study are: a reduction in subscribed power from 14913.978 kVA to 14010.100 kVA, a reduction in the transformer load rate from 99.4% to 93.4%, a reduction in reactive power called from 5481.729 kVAr to 481.729 kVAr, an increase in the active power transported by the substation from 8505.062 kW to 8962.323 kW, a reduction in the voltage drop from 4.8% to 3.9%, an increase in the power available at the secondary of the transformer station at full load from 13950 kW to 14700 kW and an annual electrical energy saving of 339943.48 kWh of electrical energy, therefore fuel savings and a reduction in CO<sub>2</sub> and SO<sub>2</sub> emissions due to this energy saving will be achieved. The installation of capacitor banks for optimization of reactive energy allowed a reduction in the current called therefore a reduction in the absorbed power: 14153.061 kVA, i.e. a reduction of 903.876 kVA. It is therefore essential that energy players are convinced of the need to install capacitors to reduce or even eliminate their reactive energy bill. This is necessarily accompanied by an investment by Electricité De Guinée by setting up active and reactive energy meters but also by implementing pricing in line with the reduction in the transfer of reactive energy in the network.
文摘This study was carried out at the Mamou Higher Institute of Technology during the period from March 10 to April 15, 2022, with the aim of designing and testing a solar dryer with forced convection by drying potatoes. The dryer was designed using local materials. Its main geometric parameters are: 1) height of the drying chamber (90 cm), 2) length of the drying chamber (50 cm), 3) width of the drying chamber (43 cm), 4) surface of the racks (0.1806 m<sup>2</sup>), 5) surface of the heat accumulator (0.2537 m<sup>2</sup>). The experiment focused on the vacuum test of the dryer for two days and that of the drying of the sweet potato for three days from 8:30 a.m. to 5:30 p.m. The average vacuum test temperature values of the three environments are respectively accumulator (43°C), dryer chamber (41°C) and ambient environment (34°C). Four kilograms (4 kg) of boiled sweet potato were dried. The average temperatures in the accumulator and in the drying chamber during the three days of drying are respectively 33°C and 39°C. The final mass of the dried product is 1.2 kg, with a quantity of water extracted of 2 liters or 63% of the initial mass of the product. The average drying rate is 0.074 kg/h. The drying kinetics showed a decreasing rate in the absence of the heating period and the constant rate period.
文摘In the town of Mamou,all homes with sanitation systems are equipped with autonomous installations not connected to a sewer network.The emptying service is provided by manual emptiers and by the living environment and sanitation service of the urban municipality which has a single 6 m^(3)truck.The objective of this work is to determine the quantity of fecal sludge produced within the city for sustainable management.The methodology adopted is based on a field survey and the use of three methods for evaluating the quantities of sludge(specific production,quantity of sludge collected by the sludge truck and the total production of sludge produced in the various sludge works).The results obtained show that,out of the 2,940 sanitation works identified,2,936 works have been emptied at least once since their construction.Then 2,307 structures are emptied manually or 78.57%,against;619 structures emptied mechanically or 21.08%.The structures are emptied on average every 3 years for septic tanks and every 5 years for dry latrines.The specific production of sludge is 685,241,532 m^(3)/year;the production of sludge by the mechanical emptying technique varies from 588,641.57 m^(3)/year to 724,800.46 m^(3)/year and the production of sludge by manual emptying is 1,573,709.33 m^(3)/year,for a total quantity of sludge produced including between 2,162,350 m^(3)/year to 685,241,531.9 m^(3)/year.
文摘This article describes the design and creation of a remote monitoring and control system based on GSM(Global System for Mobile)communications technology for monitoring the key parameters of a biodigester.Biodigesters are widely used for the conversion of organic materials into biogas,thereby contributing to renewable energy production and organic waste management.However,real-time monitoring and regulation of parameters such as temperature,humidity,product gas level,pH are essential to ensure the efficiency and safety of the digestion process.We created the device for remote control of the operating parameters of the biodigester using an Arduino card,a DHT11 sensor,a pH sensor,a GSM module and a 2×16 LCD(Liquide-Crystal-Display)display.A biodigester(4.5 L plastic container)and accessories were used.The experimental device created made it possible to remotely monitor the evolution of the temperature,humidity,the gas produced as well as the pH in the digester loaded with cow dung,for 45 days.Examination of the real-time evolution of the parameters measured by the device produced showed the same results as those carried out locally by the usual instruments,with a correlation coefficient of around 98%.During this digestion period,the temperature provided by the sensor varied from 25°C to 37°C(mesophilic mode)and the humidity levels varied from 70%to 95%.The results obtained show the reliability of the device produced.This research represents a significant advance in the management of biodigestion facilities.It offers a powerful tool to maximize biogas production,reduce maintenance costs,minimize environmental impact and contribute to the transition to cleaner,renewable energy.
文摘This research,carried out during September and October 2020 in the city of Kankan,made it possible to take stock of the city’s household waste management.The quantities of waste from the four main landfills in the city are assessed,namely:Sogbè(1350.3 m^(3)),Station(195.5 m^(3)),Station University of Kankan(2491.5 m^(3))and Salamani(369.6 m^(3)).Waste from three landfills/dumps was characterized for 26 days.This characterization covered 5,010.6 kg of waste,composed of 4263.9 kg of organic matter,462.1 kg of recyclable matter and 284.6 kg of inorganic matter.The survey concerned a target population of 403 inhabitants,which made it possible to determine a production ratio per habitant per day of(0.48 kg/habitant/d).Finally,a composting experiment of 2000 kg of organic matter was carried out.The results obtained during this study constitute the basic elements allowing defining a better policy of management of household solid waste in the city of Kankan.