A remote open-path laser-induced breakdown spectroscopy(LIBS) system was designed and studied in the present work for the purpose of combining the LIBS technique with the steel production line. In this system, the rel...A remote open-path laser-induced breakdown spectroscopy(LIBS) system was designed and studied in the present work for the purpose of combining the LIBS technique with the steel production line. In this system, the relatively simple configuration and optics were employed to measure the steel samples at a remote distance and a hot sample temperature. The system has obtained a robustness for the deviation of the sample position because of the open-path and alloptical structure. The measurement was carried out at different sample temperatures by placing the samples in a muffle furnace with a window in the front door. The results show that the intensity of the spectral lines increased as the sample temperature increased. The influence of the sample temperature on the quantitative analysis of manganese in the steel samples was investigated by measuring ten standard steel samples at different temperatures. Three samples were selected as the test sample for the simulation measurement. The results show that, at the sample temperature of 500 ℃, the average relative error of prediction is 3.1% and the average relative standard deviation is 7.7%, respectively.展开更多
Performance improvement was attained in data reconstructions of 2-dimensional tunable diode laser absorption spectroscopy(TDLAS). Multiplicative Algebraic Reconstruction Technique(MART) algorithm was adopted for data ...Performance improvement was attained in data reconstructions of 2-dimensional tunable diode laser absorption spectroscopy(TDLAS). Multiplicative Algebraic Reconstruction Technique(MART) algorithm was adopted for data reconstruction. The data obtained in an experiment for the measurement of temperature and concentration fields of gas flows were used. The measurement theory is based upon the Beer-Lambert law, and the measurement system consists of a tunable laser, collimators, detectors, and an analyzer. Methane was used as a fuel for combustion with air in the Bunsen-type burner. The data used for the reconstruction are from the optical signals of 8-laser beams passed on a cross-section of the methane flame. The performances of MART algorithm in data reconstruction were validated and compared with those obtained by Algebraic Reconstruction Technique(ART) algorithm.展开更多
A femoral artery pseudoaneurysm is one complication of vascular intervention, and the incidence is increasing. Early management is then needed to avoid potential dangers from it. It differs from a true aneurysm in tha...A femoral artery pseudoaneurysm is one complication of vascular intervention, and the incidence is increasing. Early management is then needed to avoid potential dangers from it. It differs from a true aneurysm in that it doesn't include any component of the vascular wall, and is not studied as much as a true aneurysm. Here, a model of a femoral pseudoaneurysm was made and a Computational Fluid Dynamics(CFD) simulation was verified with PIV experiment. Afterwards, a CFD simulation with two different models was performed to look for any findings which may help in developing new treatment methods.展开更多
基金supported by National Natural Science Foundation of China (Nos. 51506171 and 51675415)National Natural Science Foundation of China for Key Program (No. 51335009)+1 种基金National Key Research and Development Program of China (No. 2017YFD0700200)the joint research fund between Tokushima University and Xi’an Jiaotong University
文摘A remote open-path laser-induced breakdown spectroscopy(LIBS) system was designed and studied in the present work for the purpose of combining the LIBS technique with the steel production line. In this system, the relatively simple configuration and optics were employed to measure the steel samples at a remote distance and a hot sample temperature. The system has obtained a robustness for the deviation of the sample position because of the open-path and alloptical structure. The measurement was carried out at different sample temperatures by placing the samples in a muffle furnace with a window in the front door. The results show that the intensity of the spectral lines increased as the sample temperature increased. The influence of the sample temperature on the quantitative analysis of manganese in the steel samples was investigated by measuring ten standard steel samples at different temperatures. Three samples were selected as the test sample for the simulation measurement. The results show that, at the sample temperature of 500 ℃, the average relative error of prediction is 3.1% and the average relative standard deviation is 7.7%, respectively.
基金supported by Basic Science Research Program through the National Research Foundation of Korea(NRF)(No.2014R1A1A4A01005191)and by(No.2015 H1C1A1035890)by MSIP(No.2015R1A2A2A 01006803)
文摘Performance improvement was attained in data reconstructions of 2-dimensional tunable diode laser absorption spectroscopy(TDLAS). Multiplicative Algebraic Reconstruction Technique(MART) algorithm was adopted for data reconstruction. The data obtained in an experiment for the measurement of temperature and concentration fields of gas flows were used. The measurement theory is based upon the Beer-Lambert law, and the measurement system consists of a tunable laser, collimators, detectors, and an analyzer. Methane was used as a fuel for combustion with air in the Bunsen-type burner. The data used for the reconstruction are from the optical signals of 8-laser beams passed on a cross-section of the methane flame. The performances of MART algorithm in data reconstruction were validated and compared with those obtained by Algebraic Reconstruction Technique(ART) algorithm.
基金supported by research funding from Soongsil UniversityGrant No. 05-2011-0050 from Seoul National University Hospital Research Fund
文摘A femoral artery pseudoaneurysm is one complication of vascular intervention, and the incidence is increasing. Early management is then needed to avoid potential dangers from it. It differs from a true aneurysm in that it doesn't include any component of the vascular wall, and is not studied as much as a true aneurysm. Here, a model of a femoral pseudoaneurysm was made and a Computational Fluid Dynamics(CFD) simulation was verified with PIV experiment. Afterwards, a CFD simulation with two different models was performed to look for any findings which may help in developing new treatment methods.