Electrical Tree Image Segmentation Using Hybrid Multi Scale Line Tracking Algorithm
1
作者 Mohd Annuar isa Mohamad Nur Khairul Hafizi Rohani +7 位作者 Baharuddin Ismail Mohamad Kamarol Jamil muzamir isa Afifah Shuhada Rosmi Mohd Aminudin Jamlos Wan Azani Mustafa Nurulbariah Idris Abdullahi Abubakar Mas’ud 《Computers, Materials & Continua》 SCIE EI 2023年第4期741-760,共20页
Electrical trees are an aging mechanismmost associated with partial discharge(PD)activities in crosslinked polyethylene(XLPE)insulation of high-voltage(HV)cables.Characterization of electrical tree structures gained c... Electrical trees are an aging mechanismmost associated with partial discharge(PD)activities in crosslinked polyethylene(XLPE)insulation of high-voltage(HV)cables.Characterization of electrical tree structures gained considerable attention from researchers since a deep understanding of the tree morphology is required to develop new insulation material.Two-dimensional(2D)optical microscopy is primarily used to examine tree structures and propagation shapes with image segmentation methods.However,since electrical trees can emerge in different shapes such as bush-type or branch-type,treeing images are complicated to segment due to manifestation of convoluted tree branches,leading to a high misclassification rate during segmentation.Therefore,this study proposed a new method for segmenting 2D electrical tree images based on the multi-scale line tracking algorithm(MSLTA)by integrating batch processing method.The proposed method,h-MSLTA aims to provide accurate segmentation of electrical tree images obtained over a period of tree propagation observation under optical microscopy.The initial phase involves XLPE sample preparation and treeing image acquisition under real-time microscopy observation.The treeing images are then sampled and binarized in pre-processing.In the next phase,segmentation of tree structures is performed using the h-MSLTA by utilizing batch processing in multiple instances of treeing duration.Finally,the comparative investigation has been conducted using standard performance assessment metrics,including accuracy,sensitivity,specificity,Dice coefficient and Matthew’s correlation coefficient(MCC).Based on segmentation performance evaluation against several established segmentation methods,h-MSLTA achieved better results of 95.43%accuracy,97.28%specificity,69.43%sensitivity rate with 23.38%and 24.16%average improvement in Dice coefficient and MCC score respectively over the original algorithm.In addition,h-MSLTA produced accurate measurement results of global tree parameters of length and width in comparison with the ground truth image.These results indicated that the proposed method had a solid performance in terms of segmenting electrical tree branches in 2D treeing images compared to other established techniques. 展开更多
关键词 Image segmentation multi-scale line tracking electrical tree partial discharge high-voltage cable
下载PDF
Design, Implementation and Simulation of Non-Intrusive Sensor for On-Line Condition Monitoring of MV Electrical Components
2
作者 Muhammad Shafiq Matti Lehtonen +1 位作者 Lauri Kutt muzamir isa 《Engineering(科研)》 2014年第11期680-691,共12页
Non-intrusive measurement technology is of great interest for the electrical utilities in order to avoid an interruption in the normal operation of the supply network during diagnostics measurements and inspections. I... Non-intrusive measurement technology is of great interest for the electrical utilities in order to avoid an interruption in the normal operation of the supply network during diagnostics measurements and inspections. Inductively coupled electromagnetic sensing provides a possibility of non-intrusive measurements for online condition monitoring of the electrical components in a Medium Voltage (MV) distribution network. This is accomplished by employing Partial Discharge (PD) activity monitoring, one of the successful methods to assess the working condition of MV components but often requires specialized equipment for carrying out the measurements. In this paper, Rogowski coil sensor is presented as a robust solution for non-intrusive measurements of PD signals. A high frequency prototype of Rogowski coil is designed in the laboratory. Step-by-step approach of constructing the sensor system is presented and performance of its components (coil head, damping component, integrator and data acquisition system) is evaluated using practical and simulated environments. Alternative Transient Program-Electromagnetic Transient Program (ATP-EMTP) is used to analyze the designed model of the Rogowski coil. Real and simulated models of the coil are used to investigate the behavior of Rogowski coil sensor at its different stages of development from a transducer coil to a complete measuring device. Both models are compared to evaluate their accuracy for PD applications. Due to simple design, flexible hardware, and low cost of Rogowski coil, it can be considered as an efficient current measuring device for integrated monitoring applications where a large number of sensors are required to develop an automated online condition monitoring system for a distribution network. 展开更多
关键词 Non-Intrusive Sensors Condition Monitoring PARTIAL DISCHARGE ROGOWSKI COIL ATP-EMTP
下载PDF
Experimental Evaluation of Rogowski Coil Performance for Locating PD in Energized Overhead Covered-Conductor Feeder
3
作者 muzamir isa Nagy Ibrahim Elkalashy +1 位作者 Ghulam Murtaza Hashmi Matti Lehtonen 《Journal of Energy and Power Engineering》 2012年第6期949-959,共11页
An experimental analysis is performed to evaluate Rogowski coil performance for PD (partial discharge) location on overhead CC (covered-conductor) distribution lines. The measuring set-up is arranged in high volta... An experimental analysis is performed to evaluate Rogowski coil performance for PD (partial discharge) location on overhead CC (covered-conductor) distribution lines. The measuring set-up is arranged in high voltage laboratory. A multi-end measuring method is chosen as a technique to locate PD source point on the line. A power transformer is used to energize one end of the CC line by the AC voltage source. The performance of Rogowski-coil is tested in noisy environment. The tests are carried out conceming different measurement conditions such as off-line and on-line PD measuring systems. The results obtained from the laboratory measurements confirm the capability of the Rogowski-coil in order to measure and locate the high frequency PD source on the CC line in consistent with energizing AC source. Chirp detector is used as a signal-processing tool in order to extract the PD signals and then apply the locator algorithm. 展开更多
关键词 Partial discharge Rogowski coil overhead covered-conductor distribution network PD sensors.
下载PDF