Objectives:Meta-analysis was performed to evaluate the effect of staged revascularization with concomitant chronic total occlusion(CTO)in the non-infarct-associated artery(non-IRA)in patients with ST-segment elevation...Objectives:Meta-analysis was performed to evaluate the effect of staged revascularization with concomitant chronic total occlusion(CTO)in the non-infarct-associated artery(non-IRA)in patients with ST-segment elevation myocardial infarction(STEMI)treated with primary percutaneous coronary intervention(p-PCI).Methods:Various electronic databases were searched for studies published from inception to June,2021.The primary endpoint was all-cause death,and the secondary endpoint was a composite of major adverse cardiac events(MACEs).Odds ratios(ORs)were pooled with 95%confidence intervals(CIs)for dichotomous data.Results:Seven studies involving 1540 participants were included in thefinal analysis.Pooled analyses revealed that patients with successful staged revascularization for CTO in non-IRA with STEMI treated with p-PCI had overall lower all-cause death compared with the occluded CTO group(OR,0.46;95%CI,0.23–0.95),cardiac death(OR,0.43;95%CI,0.20–0.91),MACEs(OR,0.47;95%CI,0.32–0.69)and heart failure(OR,0.57;95%CI,0.37–0.89)com-pared with the occluded CTO group.No significant differences were observed between groups regarding myocardial infarction and repeated revascularization.Conclusions:Successful revascularization of CTO in the non-IRA was associated with better outcomes in patients with STEMI treated with p-PCI.展开更多
Objectives:The use of current robotic systems to assist in percutaneous coronary intervention(PCI)fundamentally differs from performing conventional PCI.To overcome this problem,we developed a novel master-slave robot...Objectives:The use of current robotic systems to assist in percutaneous coronary intervention(PCI)fundamentally differs from performing conventional PCI.To overcome this problem,we developed a novel master-slave robotic control system to assist in PCI,and evaluated its safety and feasibility in the delivery and manipulation of coronary guidewires in vitro and in vivo.Methods:The novel robotic assist PCI system is composed of three parts:1)a master actuator,which imitates the traditional torque used by surgeons in conventional PCI,2)a slave actuator,including a guidewire delivery system and force monitoring equipment,and 3)a local area network based communication system.Results:The experiment was performed in six pigs.Both robotic and manual control completed the operation with no device-or procedure-associated complications.An experienced interventional cardiologist who was afirst-time user of the novel robotic PCI system was able to advance the guidewire into a distal branch of a coronary artery within a similar time to that required with the manual procedure.Conclusion:This early in vivo experiment with the novel robotic assisted PCI control system demonstrated that its feasibility,safety,and procedural effectiveness are comparable to those of manual operation.The novel robotic-assisted PCI control system required significantly less time to learn than other currently available systems.展开更多
Aiming at the detection of the sucker rod defects,a real-time detection system is designed using the non-destructive testing technology of magnetic flux leakage(MFL).An MFL measurement system consists of many parts,an...Aiming at the detection of the sucker rod defects,a real-time detection system is designed using the non-destructive testing technology of magnetic flux leakage(MFL).An MFL measurement system consists of many parts,and this study focuses on the signal acquisition and processing system.First of all,this paper introduces the hardware part of the acquisition system in detail,including the selection of the Hall-effect sensor,the design of the signal conditioning circuit,and the working process of the single chip computer(SCM)control serial port.Based on LabVIEW,a graphical programming software,the software part of the acquisition system is written,including serial port parameter configuration,detection signal recognition,original signal filtering,real-time display,data storage and playback.Finally,an experimental platform for the MFL detection is set up,and the MFL measurement is carried out on the transverse and longitudinal defects of the sucker rod surface.The experimental result shows that the designed acquisition and processing system has good detection performance,simple design and high flexibility.展开更多
Background:The purpose of our study was to assess whether the occurrence of ISR might be associated with plasma TMAO levels in patients with ACS after DES implantation.Methods:This was a single center retrospective ca...Background:The purpose of our study was to assess whether the occurrence of ISR might be associated with plasma TMAO levels in patients with ACS after DES implantation.Methods:This was a single center retrospective case-control study,in which 64 symptomatic patients with repeated coronary angiography after PCI and 15 patients with ISR were included in the ISR group,and 49 patients without ISR were included in the non-ISR group.High-performance liquid chromatography with tandem mass spectrometry was used to measure plasma TMAO levels.Results:No significant differences were observed in plasma TMAO between the ISR and non-ISR groups.Plasma TMAO levels showed no significant correlation with ISR,but were significantly positively correlated with diabetes mellitus,serum HbA1c levels and serum creatinine levels;moreover,they were significantly negatively correlated with female sex.ISR was significantly positively correlated with diabetes mellitus,fasting blood glucose levels,the neutro-phil to lymphocyte ratio and syntax score;in addition,it was significantly negatively correlated with platelets.Logistic regression analysis indicated that fasting blood glucose was the only independent predictor of ISR.Conclusion:Plasma TMAO may not be associated with ISR and plaque burden in patients with ACS after DES im-plantation,whereas FBG may predict the development of ISR in these patients.展开更多
Extreme ultraviolet lithography(EUVL)and electron beam lithography(EBL)are considered to be crucial lithography techniques utilized in the fabrication of nanoscale semiconductor devices.However,the industry currently ...Extreme ultraviolet lithography(EUVL)and electron beam lithography(EBL)are considered to be crucial lithography techniques utilized in the fabrication of nanoscale semiconductor devices.However,the industry currently faces a scarcity of EUV photoresists that meet the increasingly challenging standards in terms of resolution,sensitivity and roughness.Metal oxo nanoclusters have garnered significant interest in the field of EUV photoresist due to their relatively stronger absorption cross-section for extreme ultraviolet light and lower dimensions.In this study,we utilize a heterometallic nanocluster strategy by a combination of titanium and zirconium metals to investigate their solubility,assess the suitability of various developers,and evaluate their performance in electron-beam and EUVL,as well as study their etch resistance for pattern transfer.We demonstrate that R-4 is able to get a critical dimension(CD)of 25 nm at low doses under EBL,as well as 50 nm resolution at EUVL with a remarkable sensitivity of 19.7 mJ cm−2.This study offers an efficient heterometallic method for optimizing the lithographic performance of metal oxo nanocluster photoresists,which can benefit the development of commercially viable next-generation EUV photoresists.展开更多
A promising electrochemical sensor was fabricated by electrodeposition of Pd nanoparticles (PdNPs) on poly(thiophene-3-acetic acid) (PTAA)-modified glassy carbon electrode (GCE), forming a PdNPs/PTAA composite...A promising electrochemical sensor was fabricated by electrodeposition of Pd nanoparticles (PdNPs) on poly(thiophene-3-acetic acid) (PTAA)-modified glassy carbon electrode (GCE), forming a PdNPs/PTAA composites-modified GCE (PdNPs/PTAA/GCE). Scanning electron microscope (SEM) and electrochemical techniques were used for the characterization of these composites. It was found that the PdNPs/PTAA layer was very uniform. ]Electrochemical experiments showed that this proposed PdNPs/PTAA composites-modified electrode exhibited excellent electrocatalytic activity towards the oxidation of hydrazine. Under the optimum conditions, the proposed sensor can be applied to the quantification of hydrazine with a wide linear range from 8.0 × 10-9 mol/L to 1.0 × 10-5 mol/L with a low detection limit of 2.67 × 10-9 mol/L. The experiment results also showed that the sensor exhibited good reproducibility and long-term stability, as well as high selectivity with no interference from other potential competing species.展开更多
基金supported by the Beijing Tsinghua Changgung Hospital Fund(grant No.12019C1009).
文摘Objectives:Meta-analysis was performed to evaluate the effect of staged revascularization with concomitant chronic total occlusion(CTO)in the non-infarct-associated artery(non-IRA)in patients with ST-segment elevation myocardial infarction(STEMI)treated with primary percutaneous coronary intervention(p-PCI).Methods:Various electronic databases were searched for studies published from inception to June,2021.The primary endpoint was all-cause death,and the secondary endpoint was a composite of major adverse cardiac events(MACEs).Odds ratios(ORs)were pooled with 95%confidence intervals(CIs)for dichotomous data.Results:Seven studies involving 1540 participants were included in thefinal analysis.Pooled analyses revealed that patients with successful staged revascularization for CTO in non-IRA with STEMI treated with p-PCI had overall lower all-cause death compared with the occluded CTO group(OR,0.46;95%CI,0.23–0.95),cardiac death(OR,0.43;95%CI,0.20–0.91),MACEs(OR,0.47;95%CI,0.32–0.69)and heart failure(OR,0.57;95%CI,0.37–0.89)com-pared with the occluded CTO group.No significant differences were observed between groups regarding myocardial infarction and repeated revascularization.Conclusions:Successful revascularization of CTO in the non-IRA was associated with better outcomes in patients with STEMI treated with p-PCI.
基金supported by the Capital Health Research and Development of Special(2020-4-2243)Beijing Municipal Administration of Hospitals Incubating Program(No.PX2021039)+1 种基金Beijing Hospitals Authority Ascent Plan(No.DFL20190902)Beijing Hospitals Authority Clinical Medicine Development of Special Funding Support(No.ZYLX201831).
文摘Objectives:The use of current robotic systems to assist in percutaneous coronary intervention(PCI)fundamentally differs from performing conventional PCI.To overcome this problem,we developed a novel master-slave robotic control system to assist in PCI,and evaluated its safety and feasibility in the delivery and manipulation of coronary guidewires in vitro and in vivo.Methods:The novel robotic assist PCI system is composed of three parts:1)a master actuator,which imitates the traditional torque used by surgeons in conventional PCI,2)a slave actuator,including a guidewire delivery system and force monitoring equipment,and 3)a local area network based communication system.Results:The experiment was performed in six pigs.Both robotic and manual control completed the operation with no device-or procedure-associated complications.An experienced interventional cardiologist who was afirst-time user of the novel robotic PCI system was able to advance the guidewire into a distal branch of a coronary artery within a similar time to that required with the manual procedure.Conclusion:This early in vivo experiment with the novel robotic assisted PCI control system demonstrated that its feasibility,safety,and procedural effectiveness are comparable to those of manual operation.The novel robotic-assisted PCI control system required significantly less time to learn than other currently available systems.
文摘Aiming at the detection of the sucker rod defects,a real-time detection system is designed using the non-destructive testing technology of magnetic flux leakage(MFL).An MFL measurement system consists of many parts,and this study focuses on the signal acquisition and processing system.First of all,this paper introduces the hardware part of the acquisition system in detail,including the selection of the Hall-effect sensor,the design of the signal conditioning circuit,and the working process of the single chip computer(SCM)control serial port.Based on LabVIEW,a graphical programming software,the software part of the acquisition system is written,including serial port parameter configuration,detection signal recognition,original signal filtering,real-time display,data storage and playback.Finally,an experimental platform for the MFL detection is set up,and the MFL measurement is carried out on the transverse and longitudinal defects of the sucker rod surface.The experimental result shows that the designed acquisition and processing system has good detection performance,simple design and high flexibility.
基金supported by grant 81970299 from the National Natural Science Foundation of China,Beijing Hospitals Authority Ascent Plan(No.DFL20190902)Beijing Municipal Administration of Hospitals Incubating Program(No.PX2021039)+1 种基金Beijing Hospitals Authority Clinical Medicine development of special funding support(No.ZYLX201831)The Capital Health Research and Development of Special(No.2020-4-2243).
文摘Background:The purpose of our study was to assess whether the occurrence of ISR might be associated with plasma TMAO levels in patients with ACS after DES implantation.Methods:This was a single center retrospective case-control study,in which 64 symptomatic patients with repeated coronary angiography after PCI and 15 patients with ISR were included in the ISR group,and 49 patients without ISR were included in the non-ISR group.High-performance liquid chromatography with tandem mass spectrometry was used to measure plasma TMAO levels.Results:No significant differences were observed in plasma TMAO between the ISR and non-ISR groups.Plasma TMAO levels showed no significant correlation with ISR,but were significantly positively correlated with diabetes mellitus,serum HbA1c levels and serum creatinine levels;moreover,they were significantly negatively correlated with female sex.ISR was significantly positively correlated with diabetes mellitus,fasting blood glucose levels,the neutro-phil to lymphocyte ratio and syntax score;in addition,it was significantly negatively correlated with platelets.Logistic regression analysis indicated that fasting blood glucose was the only independent predictor of ISR.Conclusion:Plasma TMAO may not be associated with ISR and plaque burden in patients with ACS after DES im-plantation,whereas FBG may predict the development of ISR in these patients.
基金supported by the National Natural Science Foundation of China(22271284 and 91961108)“the Fundamental Research Funds for the Central Universities”,Nankai University(075-63233091)。
文摘Extreme ultraviolet lithography(EUVL)and electron beam lithography(EBL)are considered to be crucial lithography techniques utilized in the fabrication of nanoscale semiconductor devices.However,the industry currently faces a scarcity of EUV photoresists that meet the increasingly challenging standards in terms of resolution,sensitivity and roughness.Metal oxo nanoclusters have garnered significant interest in the field of EUV photoresist due to their relatively stronger absorption cross-section for extreme ultraviolet light and lower dimensions.In this study,we utilize a heterometallic nanocluster strategy by a combination of titanium and zirconium metals to investigate their solubility,assess the suitability of various developers,and evaluate their performance in electron-beam and EUVL,as well as study their etch resistance for pattern transfer.We demonstrate that R-4 is able to get a critical dimension(CD)of 25 nm at low doses under EBL,as well as 50 nm resolution at EUVL with a remarkable sensitivity of 19.7 mJ cm−2.This study offers an efficient heterometallic method for optimizing the lithographic performance of metal oxo nanocluster photoresists,which can benefit the development of commercially viable next-generation EUV photoresists.
基金financially supported by the National Natural Science Foundation of China (Nos.50963002,51073074)Jiangxi Provincial Department of Education (Nos.GJJ11590,GJJ10678)
文摘A promising electrochemical sensor was fabricated by electrodeposition of Pd nanoparticles (PdNPs) on poly(thiophene-3-acetic acid) (PTAA)-modified glassy carbon electrode (GCE), forming a PdNPs/PTAA composites-modified GCE (PdNPs/PTAA/GCE). Scanning electron microscope (SEM) and electrochemical techniques were used for the characterization of these composites. It was found that the PdNPs/PTAA layer was very uniform. ]Electrochemical experiments showed that this proposed PdNPs/PTAA composites-modified electrode exhibited excellent electrocatalytic activity towards the oxidation of hydrazine. Under the optimum conditions, the proposed sensor can be applied to the quantification of hydrazine with a wide linear range from 8.0 × 10-9 mol/L to 1.0 × 10-5 mol/L with a low detection limit of 2.67 × 10-9 mol/L. The experiment results also showed that the sensor exhibited good reproducibility and long-term stability, as well as high selectivity with no interference from other potential competing species.