A rapid method to determine glutamic acid (Glu) in cerebrospinal fluid (CSF) by capillaryelectrophoresis with high frequency conductivity detection (contactless conductivity detection) wasdescribed. The CSF sample was...A rapid method to determine glutamic acid (Glu) in cerebrospinal fluid (CSF) by capillaryelectrophoresis with high frequency conductivity detection (contactless conductivity detection) wasdescribed. The CSF sample was pretreated with silver cation resin to remove high concentration ofCl- ions in CSF. The separation was achieved in the buffer solution of 10 mmol/L Tris and 8mmol/L boric acid at the separation voltage of 20.0 kV. Glu showed linear response in the range of5.0×10-6 to 6.0×10-3 mol/L, the limit of detection was 1.0×10-6 mol/L. The method was used foranalysis Glu in CSF satisfactorily with a recovery of 97.8-98.8%.展开更多
The period-3 behaviors of 105 exons from 20 genes in human were studied by Fourier power spectrum. The results indicated that not all exons show the period-3 behavior. The exons were adjusted in order to make them acc...The period-3 behaviors of 105 exons from 20 genes in human were studied by Fourier power spectrum. The results indicated that not all exons show the period-3 behavior. The exons were adjusted in order to make them accord with the order of the protein translated, and we found that the period-3 character is relation to the length of exons and the bases distribution in the three codon position. Furthermore, as long as the exons with period-3 behavior accord with the order of protein translated, they would exhibit the synonymous codons usage preference, and the codons with g/c at the third position are used in higher frequency. The results are significant to the gene prediction and the research on the introns.展开更多
基金This project was supported by the Guangdong Provincial Foundation of Natural Science(021808)
文摘A rapid method to determine glutamic acid (Glu) in cerebrospinal fluid (CSF) by capillaryelectrophoresis with high frequency conductivity detection (contactless conductivity detection) wasdescribed. The CSF sample was pretreated with silver cation resin to remove high concentration ofCl- ions in CSF. The separation was achieved in the buffer solution of 10 mmol/L Tris and 8mmol/L boric acid at the separation voltage of 20.0 kV. Glu showed linear response in the range of5.0×10-6 to 6.0×10-3 mol/L, the limit of detection was 1.0×10-6 mol/L. The method was used foranalysis Glu in CSF satisfactorily with a recovery of 97.8-98.8%.
基金This work was supported by the National Natural Science Foundation of China(Grants 20475068)the Natural Science Foundation of Guangdong Province(Contact No.031577)the Opening Foundation of State Key Laboratory of Chem/Biosensing and Chemometrics of Hunan University(2003).
文摘The period-3 behaviors of 105 exons from 20 genes in human were studied by Fourier power spectrum. The results indicated that not all exons show the period-3 behavior. The exons were adjusted in order to make them accord with the order of the protein translated, and we found that the period-3 character is relation to the length of exons and the bases distribution in the three codon position. Furthermore, as long as the exons with period-3 behavior accord with the order of protein translated, they would exhibit the synonymous codons usage preference, and the codons with g/c at the third position are used in higher frequency. The results are significant to the gene prediction and the research on the introns.