期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Determination of aniline in environmental water samples by alternating-current oscillopolarographic titration 被引量:6
1
作者 Jun Ping Xiao qing xiang zhou +2 位作者 Xiao Ke Tian Hua Hua Bai Xian Fa Su 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期730-733,共4页
A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosa... A new method for the determination of aniline in environmental water based on oscillopolarographic titration was presented in this paper. Several factors including the kind, concentration, and volume of acid, the dosage of potassium bromide, the temperature and concentration of concomitant substances were investigated in detail. The experimental results indicated that this method was simple, rapid, and sensitive. The linear range was 8.367 × 10(?4) to 2.789 × 10(?2) mol L(?1), the relative standard deviation (R.S.D.) was lower than 0.96%, and the spiked recoveries of aniline in environmental water samples were in the range of 99.4–106.9% under the optimal conditions. The results indicated that the present method could be used as an alternative method for aniline determination in realworld water samples. 展开更多
关键词 Alternating-current oscillopolarographic titration ANILINE Potassium bromide
下载PDF
Enhancement of Sensitivity for Determination of Phenols in Environmental Water Samples by Single-drop Liquid Phase Microextraction Using Ionic Liquid prior to HPLC 被引量:5
2
作者 qing xiang zhou Jun Ping XIAO +1 位作者 Cun Ling YE Xin Ming WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第8期1073-1076,共4页
A single-drop liquid phase micro-extraction procedure using 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) was demonstrated for the sensitive determination of four phenols in water samples. Under the... A single-drop liquid phase micro-extraction procedure using 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) was demonstrated for the sensitive determination of four phenols in water samples. Under the optimized conditions, the linear range of proposed method was excellent in the range of 0.5-100 μg·L^-1, the reproducibility (RSD, n=6) were in the range 5.4%-8.9% and detection limits (S/N=3) were 0.3, 0.3, 0.5 and 0.5 μg·L^-1 for 2, 4-dichlorophenol, 2-naphthol, 2-nitrophenol and 4-chlorophenol, respectively. The experimental results indicated that the effect of complex matrices natural water samples could be resolved with addition of sodium ethylene diamine tetracetate (EDTA) into the samples. Excellent spiked recoveries were achieved for these four phenols ranged from 86.2%-114.9 %. All these facts demonstrated that the proposed method with merits of low cost, simplicity and easy operating would be a competitive alternative procedure for the determination of such compounds at trace level. 展开更多
关键词 1-Butyl-3-methylimidazolium hexafluorophosphate single-drop liquid phase microextraction phenols.
下载PDF
Sensitive determination of fenpropathrin,cyhalothrin and deltamethrin in environmental water samples using multiwalled carbon nanotubes cartridge prior to HPLC 被引量:3
3
作者 qing xiang zhou Guo Hong Xie +2 位作者 Jun Ping Xiao Wei Dong Wang Yu Jie Ding 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第1期95-98,共4页
This paper described a new method for the trace determination of fenpropathrin, cyhalothrin and deltamethrin using multiwalled carbon nanotubes (MWCNTs) cartridge. Important parameters, such as the sample pH, eluent... This paper described a new method for the trace determination of fenpropathrin, cyhalothrin and deltamethrin using multiwalled carbon nanotubes (MWCNTs) cartridge. Important parameters, such as the sample pH, eluent and its volume, sample flow rate and sample volume were investigated in detail. The linear ranges, the detection limits, and precisions (R.S.D.) were in the range of 0.1- 40 μg L^-11, 1.34.3 ng L^-1 and 2.3-2.8%, respectively. The performance of the proposed method was validated with real water samples, and the spiked recoveries were in the range of 91.7-117.8%, respectively. The experimental results demonstrated that the proposed method was an excellent alternative for the routine analysis of such pollutants in environmental samples. 2007 Qing Xiang Zhou. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved. 展开更多
关键词 Multiwalled carbon nanotubes FENPROPATHRIN CYHALOTHRIN DELTAMETHRIN High performance liquid chromatography
下载PDF
Preconcentration of copper with multi-walled carbon nanotubes pretreated by potassium permanganate cartridge for solid phase extraction prior to flame atomic absorption spectrometry 被引量:2
4
作者 Jun Ping Xiao qing xiang zhou Hua Hua Bai 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期714-717,共4页
A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water s... A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1–100 ng/mL (R(2) = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment. 展开更多
关键词 Multi-walled carbon nanotubes Solid phase extraction (SPE) Flame atomic absorption spectrometry
下载PDF
Rapid determination of atrazine in environmental water samples by a novel liquid phase microextraction 被引量:1
5
作者 qing xiang zhou Guo Hong Xie Long Pang 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第1期89-91,共3页
A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such a... A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such as sample pH, extraction and disperser solvents, salting-out effect, and extraction time were investigated. The experimental results indicated that proposed method possessed an excellent analytical performance, The linear range, detection limit, and precision (R.S.D.) were 0.1- 50 ng mL- 1 (R2 = 0.9955), 0.601 ng mL- 1 and 6,4%, respectively. The proposed method was validated with the real water samples, and the spiked recoveries were in the range of 69.9-89.8%, respectively. These results indicated that the established method with high enrichment factor, short extraction time was an excellent alternative for the routine analysis of atrazine in environmental samples. 2007 Qing Xiang Zhou. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved. 展开更多
关键词 Liquid phase microextraction ATRAZINE High performance liquid chromatography Water samples
下载PDF
TiO_2 nanotubes:A novel solid phase extraction adsorbent for the sensitive determination of nickel in environmental water samples 被引量:1
6
作者 Xin Ning Zhao Qi Zeng Shi +1 位作者 Guo Hong Xie qing xiang zhou 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第7期865-867,共3页
A novel method was developed for the sensitive determination of nickel in environmental water samples by using TiO2 nanotubes, a new nanomaterial, as solid phase extraction absorbent. In general, TiO2 nanomaterials we... A novel method was developed for the sensitive determination of nickel in environmental water samples by using TiO2 nanotubes, a new nanomaterial, as solid phase extraction absorbent. In general, TiO2 nanomaterials were often used for catalytic degradation of pollutants in environmental field, and only a very few application in environmental analytic chemistry. In present work, TiO2 nanotubes was firstly used for the enrichment of nickel and the factors would influence the preconcentration performance were optimized. Under the optimal conditions, TiO2 nanotubes exhibited its good enrichment capacity for nickel and the detection limit of the proposed method was 1 ng· mL^-1. The proposed method was validated with real water samples, and excellent results were obtained with the spiked recoveries in the range of 94.4-99.2%, respectively. 展开更多
关键词 TiO2 nanotubes NICKEL Flame atomic absorption spectrometry
下载PDF
Fluorometric determination of nonylphenol in water samples enriched with zirconium doped titanium dioxide nanotubes solid phase extraction 被引量:5
7
作者 Xian Fa Su Xin Ning Zhao +1 位作者 Guo Hong Xie qing xiang zhou 《Chinese Chemical Letters》 SCIE CAS CSCD 2012年第8期969-972,共4页
This paper developed a fluorometric method for the sensitive determination of nonylphenol in water samples by preconcentration with zirconium doped titanium dioxide nanotubes solid phase extraction.The parameters on e... This paper developed a fluorometric method for the sensitive determination of nonylphenol in water samples by preconcentration with zirconium doped titanium dioxide nanotubes solid phase extraction.The parameters on extraction that would influence the enrichment performance such as the kind and volume of eluent,sample pH,sample flow rate,and sample volume were optimized in detail.Under the optimal conditions,the proposed method provided an excellent linear range of 1-150 mg/L and good LOD of 0.076 mg/L.The relative standard deviation(RSD,n = 6) was 2.8%.Proposed method was also used for the analysis of real water samples and the spiked recoveries were satisfied in the range of 98.7-103%. 展开更多
关键词 Zirconium doped TiO2 nanotubes NONYLPHENOL Solid phase extraction Water samples
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部