The splitter is an important component of water-based cooling systems used to extract heat from computer boards.In the present study,the flow characteristics of a 16-splitter structure were numerically simulated and c...The splitter is an important component of water-based cooling systems used to extract heat from computer boards.In the present study,the flow characteristics of a 16-splitter structure were numerically simulated and compared with experimental results to verify the reliability of the numerical simulation method.Accordingly,the concept of splitter structural coefficients was proposed.Based on the results of this study,we recommend a selection range of 5≤k≤6 for the structure factor k of the splitter;after optimization,the maximum deviation of the splitter outlet flow was reduced from the original value of 100%to 8.3%.展开更多
To investigate the fouling characteristics of the composite insulator surface under the salt fog environment,the FXBW-110/120-2 composite insulator was taken as the research object.Based on the field-induced charge me...To investigate the fouling characteristics of the composite insulator surface under the salt fog environment,the FXBW-110/120-2 composite insulator was taken as the research object.Based on the field-induced charge mechanism,the multi-physical field coupling software COMSOL was used to numerically simulate the fouling characteristics,explored the calculation method of ESDD,and demonstrated its rationality.Based on this method,the pollution characteristics of the composite insulator under the pollution fog environment were studied,and the influence of wind speed,droplet size,and voltage type on the pollution characteristics of the composite insulator was analyzed.The results showed that:with the increase in wind speed,the amount of accumulated pollution of insulator increases in the range of droplet size,and the relationship between wind speed and accumulated pollution is approximately linear;at the same wind speed,the amount of accumulated pollution increases with the increase of droplet size under the action of DC voltage;when there is no voltage,the amount of dirt on the upper surface of the insulator is more than that on the lower surface,while it is the opposite under DC voltage.展开更多
The water-cooling heat dissipation technology can solve the heat dissipation and noise problems of the calculation plate.Therefore,the structural design of the water-cooling plate directly affects its flow and heat tr...The water-cooling heat dissipation technology can solve the heat dissipation and noise problems of the calculation plate.Therefore,the structural design of the water-cooling plate directly affects its flow and heat transfer characteristics,which restricts the promotion and application of the technology.To this end,the water-cooling plate of a heat dissipation system was taken as the research object,and its flow and heat transfer characteristics were numerical simulated and experimental studied.Through comparative analysis,the rationality of the numerical simulation method was verified.Based on this,three improved schemes of water-cooling plate structure were proposed and numerical simulation was carried out,and the optimal model was verified by experiments.The results of the study show that compared with the original water-cooling plate,the optimized water-cooling plate has increased internal flow velocity and distributes uniformly,increased heat transfer amount by 4.2%,and the average temperature of the calculation plate decreased by 5.3%.展开更多
文摘The splitter is an important component of water-based cooling systems used to extract heat from computer boards.In the present study,the flow characteristics of a 16-splitter structure were numerically simulated and compared with experimental results to verify the reliability of the numerical simulation method.Accordingly,the concept of splitter structural coefficients was proposed.Based on the results of this study,we recommend a selection range of 5≤k≤6 for the structure factor k of the splitter;after optimization,the maximum deviation of the splitter outlet flow was reduced from the original value of 100%to 8.3%.
文摘To investigate the fouling characteristics of the composite insulator surface under the salt fog environment,the FXBW-110/120-2 composite insulator was taken as the research object.Based on the field-induced charge mechanism,the multi-physical field coupling software COMSOL was used to numerically simulate the fouling characteristics,explored the calculation method of ESDD,and demonstrated its rationality.Based on this method,the pollution characteristics of the composite insulator under the pollution fog environment were studied,and the influence of wind speed,droplet size,and voltage type on the pollution characteristics of the composite insulator was analyzed.The results showed that:with the increase in wind speed,the amount of accumulated pollution of insulator increases in the range of droplet size,and the relationship between wind speed and accumulated pollution is approximately linear;at the same wind speed,the amount of accumulated pollution increases with the increase of droplet size under the action of DC voltage;when there is no voltage,the amount of dirt on the upper surface of the insulator is more than that on the lower surface,while it is the opposite under DC voltage.
文摘The water-cooling heat dissipation technology can solve the heat dissipation and noise problems of the calculation plate.Therefore,the structural design of the water-cooling plate directly affects its flow and heat transfer characteristics,which restricts the promotion and application of the technology.To this end,the water-cooling plate of a heat dissipation system was taken as the research object,and its flow and heat transfer characteristics were numerical simulated and experimental studied.Through comparative analysis,the rationality of the numerical simulation method was verified.Based on this,three improved schemes of water-cooling plate structure were proposed and numerical simulation was carried out,and the optimal model was verified by experiments.The results of the study show that compared with the original water-cooling plate,the optimized water-cooling plate has increased internal flow velocity and distributes uniformly,increased heat transfer amount by 4.2%,and the average temperature of the calculation plate decreased by 5.3%.