BACKGROUND Magnetic compression anastomosis(MCA)is a simple procedure contributing to a reliable anastomosis.However,digestive-tract reconstruction after total gastrectomy using MCA has not yet been reported.AIM To in...BACKGROUND Magnetic compression anastomosis(MCA)is a simple procedure contributing to a reliable anastomosis.However,digestive-tract reconstruction after total gastrectomy using MCA has not yet been reported.AIM To investigate the feasibility of MCA for simultaneous esophagojejunostomy and jejunojejunostomy after total gastrectomy using beagle dogs.METHODS Sixteen beagles were randomly divided into an MCA group(study group,n=8)and a manual-suture anastomosis group(control group,n=8).Two different magnetic anastomosis devices were used in the study group for esophagojejunal and jejunojejunal anastomoses.Both devices included a pair of circular daughter and parent magnets each.The time of esophagojejunostomy and jejunojejunostomy,postoperative complications,and survival rate of the two groups were compared.The dogs were sacrificed one month after the operation and their anastomotic specimens were obtained.Healing was observed by the naked eye and a light microscope.RESULTS Digestive-tract reconstruction after total gastrectomy was successfully completed in both groups(survival rate=100%).In the study group,esophagojejunal and jejunojejunal anastomoses took 6.13±0.58 and 4.06±0.42 min,respectively,significantly lower than those in the control group(15.63±1.53 min,P<0.001 and 10.31±1.07 min,P<0.001,respectively).Complications such as bleeding,anastomotic leakage,and anastomotic stenosis were not observed.In the study group,the magnets did not interfere with each other.Discharge time of the jejunojejunal magnetic anastomosis device was 10.75±1.28 d,while that of the esophagojejunal magnetic anastomosis device was 12.25±1.49 d.Residual silk was found in the control group.The study group showed a greater smoothness of the anastomosis than that of the control group.All layers of anastomosis healed well in both groups.CONCLUSION MCA is a safe and feasible procedure for digestive-tract reconstruction after total gastrectomy in this animal model.展开更多
BACKGROUND Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis,there is no report on a single-approach operation using the natural orifice.AIM To design a def...BACKGROUND Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis,there is no report on a single-approach operation using the natural orifice.AIM To design a deformable self-assembled magnetic anastomosis ring(DSAMAR)for colonic anastomosis for use in single-approach operation and evaluate its feasibility and safety through animal experiments.METHODS The animal model for colonic stenosis was prepared by partial colonic ligation in eight beagles.The magnetic compression anastomosis of their colonic stricture was performed by endoscopically assisted transanal implantation of the DSAMAR.The anastomotic specimen,obtained 2 wk after the operation,was observed by both the naked eye and a light microscope.RESULTS The DSAMAR was successfully inserted into the proximal end of colon stenosis through the anus.The DSAMAR of seven dogs was successfully transformed into rings,while that of the remaining dog was removed after the first deformation failed.The rings were successfully retransformed after optimization.All animals underwent colonic anastomosis using the DSAMAR.No device-related or procedure-related adverse events were observed.The colostomy specimens of the experimental dogs were obtained 2 wk after the operation.Both gross and histological observations showed good anastomotic healing.CONCLUSION The DSAMAR is a safe and feasible option for the treatment of colon stenosis.Its specific deformation and selfassembly capability maximize the applicability of the minimally invasive treatment.展开更多
BACKGROUND Hepatic portal blood flow occlusion is a common technique for reducing hepatic hemorrhage during hepatectomy.We designed a novel Y-Z magnetic hepatic portal blocking band(Y-Z MHPBB)based on the principle of...BACKGROUND Hepatic portal blood flow occlusion is a common technique for reducing hepatic hemorrhage during hepatectomy.We designed a novel Y-Z magnetic hepatic portal blocking band(Y-Z MHPBB)based on the principle of magnetic compression technique.AIM To introduce the Y-Z MHPBB device and verify the feasibility of this device for hepatic portal blood flow occlusion in dogs.METHODS Ten beagles were randomly divided into the experimental group and control group.The operation time,intraoperative blood loss,the number of portal blood flow occlusions,the total time spent on adjusting the blocking band,and the average time spent on adjusting the blocking band were recorded.The surgeons evaluated the feasibility and flexibility of the two portal occlusion devices.RESULTS Laparoscopic hepatectomy was successfully performed in both the experimental group and control group.There was no statistical difference between the two groups in the operation time,intraoperative blood loss,and the number of hepatic portal blood flow occlusions.With respect to the total time spent on adjusting the blocking band and the average time spent on adjusting the blocking band,the experimental group showed significantly better outcomes than the control group,with a statistical difference(P<0.05).The operators found that the Y-Z MHPBB was superior to the modified T-tube in terms of operational flexibility.CONCLUSION The Y-Z MHPBB seems to be an ingenious design,accurate blood flow occlusion effect,and good flexibility;and it can be used for hepatic portal blood flow occlusion during laparoscopic hepatectomy.展开更多
BACKGROUND Esophageal cancer has high incidence globally and is often diagnosed at an advanced stage.With the widespread application of endoscopic technologies,the need for early detection and diagnosis of esophageal ...BACKGROUND Esophageal cancer has high incidence globally and is often diagnosed at an advanced stage.With the widespread application of endoscopic technologies,the need for early detection and diagnosis of esophageal cancer has gradually been realized.Endoscopic submucosal dissection(ESD)has become the standard of care for managing early tumors of the esophagus,stomach,and colon.However,due to the steep learning curve,difficult operation,and technically demanding nature of the procedure,ESD has currently been committed to the development of various assistive technologies.AIM To explore the feasibility and applicability of magnetic anchor technique(MAT)-assisted ESD for early esophageal cancer.METHODS Isolated pig esophagi were used as the experimental model,and the magnetic anchor device was designed by us.The esophagi used were divided into two groups,namely the operational and control groups,and 10 endoscopists completed the procedure.The two groups were evaluated for the following aspects:The total operative time,perforation rate,rate of whole mucosal resection,diameter of the peering mucosa,and scores of endoscopists’feelings with the procedure,including the convenience,mucosal surface exposure degree,and tissue tension.In addition,in the operational group,the soft tissue clip and the target magnet(TM)were connected by a thin wire through a small hole at the tail end of the TM.Under gastroscopic guidance,the soft tissue clip was clamped to the edge of the lesioned mucosa,which was marked in advance.By changing the position of the anchor magnet(AM)outside the esophagus,the pulling force and pulling direction of the TM could be changed,thus exposing the mucosal peeling surface and assisting the ESD.RESULTS Herein,each of the two groups comprised 10 isolated esophageal putative mucosal lesions.The diameter of the peering mucosa did not significantly differ between the two groups(2.13±0.06 vs 2.15±0.06,P=0.882).The total operative time was shorter in the operational group than in the control group(17.04±0.22 min vs 21.94±0.23 min,P<0.001).During the entire experiment,the TM remained firmly connected with the soft tissue clip and did not affect the opening,closing,and release of the soft tissue clip.The interaction between the TM and AM could provide sufficient tissue tension and completely expose the mucosa,which greatly assists the surgeon with the operation.There was no avulsion of the mucosa,and mucosal lesions were intact when peeled.Therefore,the scores of endoscopists’feelings were higher in the operational group than in the control group in terms of the convenience(9.22±0.19 vs 8.34±0.15,P=0.002),mucosal surface exposure degree(9.11±0.15 vs 8.25±0.12,P<0.001),and tissue tension(9.35±0.13 vs 8.02±0.17,P<0.001).The two groups did not significantly differ in the perforation rate and rate of whole mucosal resection.CONCLUSION We found MAT-assisted ESD safe and feasible for early esophageal cancer.It could greatly improve the endoscopic operation experience and showed good clinical application prospects.展开更多
基金the Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University,No.2022MS-07(to Yan XP)Key Research and Development Plan of Shaanxi Province,No.2021GXLH-Z-009(to Li Y).
文摘BACKGROUND Magnetic compression anastomosis(MCA)is a simple procedure contributing to a reliable anastomosis.However,digestive-tract reconstruction after total gastrectomy using MCA has not yet been reported.AIM To investigate the feasibility of MCA for simultaneous esophagojejunostomy and jejunojejunostomy after total gastrectomy using beagle dogs.METHODS Sixteen beagles were randomly divided into an MCA group(study group,n=8)and a manual-suture anastomosis group(control group,n=8).Two different magnetic anastomosis devices were used in the study group for esophagojejunal and jejunojejunal anastomoses.Both devices included a pair of circular daughter and parent magnets each.The time of esophagojejunostomy and jejunojejunostomy,postoperative complications,and survival rate of the two groups were compared.The dogs were sacrificed one month after the operation and their anastomotic specimens were obtained.Healing was observed by the naked eye and a light microscope.RESULTS Digestive-tract reconstruction after total gastrectomy was successfully completed in both groups(survival rate=100%).In the study group,esophagojejunal and jejunojejunal anastomoses took 6.13±0.58 and 4.06±0.42 min,respectively,significantly lower than those in the control group(15.63±1.53 min,P<0.001 and 10.31±1.07 min,P<0.001,respectively).Complications such as bleeding,anastomotic leakage,and anastomotic stenosis were not observed.In the study group,the magnets did not interfere with each other.Discharge time of the jejunojejunal magnetic anastomosis device was 10.75±1.28 d,while that of the esophagojejunal magnetic anastomosis device was 12.25±1.49 d.Residual silk was found in the control group.The study group showed a greater smoothness of the anastomosis than that of the control group.All layers of anastomosis healed well in both groups.CONCLUSION MCA is a safe and feasible procedure for digestive-tract reconstruction after total gastrectomy in this animal model.
基金the Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University,No.2022MS-07the Key Research&Development Program-Social Development of Shaanxi Province of China,No.2023-YBSF-247.
文摘BACKGROUND Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis,there is no report on a single-approach operation using the natural orifice.AIM To design a deformable self-assembled magnetic anastomosis ring(DSAMAR)for colonic anastomosis for use in single-approach operation and evaluate its feasibility and safety through animal experiments.METHODS The animal model for colonic stenosis was prepared by partial colonic ligation in eight beagles.The magnetic compression anastomosis of their colonic stricture was performed by endoscopically assisted transanal implantation of the DSAMAR.The anastomotic specimen,obtained 2 wk after the operation,was observed by both the naked eye and a light microscope.RESULTS The DSAMAR was successfully inserted into the proximal end of colon stenosis through the anus.The DSAMAR of seven dogs was successfully transformed into rings,while that of the remaining dog was removed after the first deformation failed.The rings were successfully retransformed after optimization.All animals underwent colonic anastomosis using the DSAMAR.No device-related or procedure-related adverse events were observed.The colostomy specimens of the experimental dogs were obtained 2 wk after the operation.Both gross and histological observations showed good anastomotic healing.CONCLUSION The DSAMAR is a safe and feasible option for the treatment of colon stenosis.Its specific deformation and selfassembly capability maximize the applicability of the minimally invasive treatment.
基金Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University(to Yan XP),No.2022MS-07。
文摘BACKGROUND Hepatic portal blood flow occlusion is a common technique for reducing hepatic hemorrhage during hepatectomy.We designed a novel Y-Z magnetic hepatic portal blocking band(Y-Z MHPBB)based on the principle of magnetic compression technique.AIM To introduce the Y-Z MHPBB device and verify the feasibility of this device for hepatic portal blood flow occlusion in dogs.METHODS Ten beagles were randomly divided into the experimental group and control group.The operation time,intraoperative blood loss,the number of portal blood flow occlusions,the total time spent on adjusting the blocking band,and the average time spent on adjusting the blocking band were recorded.The surgeons evaluated the feasibility and flexibility of the two portal occlusion devices.RESULTS Laparoscopic hepatectomy was successfully performed in both the experimental group and control group.There was no statistical difference between the two groups in the operation time,intraoperative blood loss,and the number of hepatic portal blood flow occlusions.With respect to the total time spent on adjusting the blocking band and the average time spent on adjusting the blocking band,the experimental group showed significantly better outcomes than the control group,with a statistical difference(P<0.05).The operators found that the Y-Z MHPBB was superior to the modified T-tube in terms of operational flexibility.CONCLUSION The Y-Z MHPBB seems to be an ingenious design,accurate blood flow occlusion effect,and good flexibility;and it can be used for hepatic portal blood flow occlusion during laparoscopic hepatectomy.
基金the Key Research&Development Program-Social Development of Shaanxi Province of China,No.2021SF-163and the Innovation Capability Support Plan of Shaanxi Province of China,No.2020KJXX-022.
文摘BACKGROUND Esophageal cancer has high incidence globally and is often diagnosed at an advanced stage.With the widespread application of endoscopic technologies,the need for early detection and diagnosis of esophageal cancer has gradually been realized.Endoscopic submucosal dissection(ESD)has become the standard of care for managing early tumors of the esophagus,stomach,and colon.However,due to the steep learning curve,difficult operation,and technically demanding nature of the procedure,ESD has currently been committed to the development of various assistive technologies.AIM To explore the feasibility and applicability of magnetic anchor technique(MAT)-assisted ESD for early esophageal cancer.METHODS Isolated pig esophagi were used as the experimental model,and the magnetic anchor device was designed by us.The esophagi used were divided into two groups,namely the operational and control groups,and 10 endoscopists completed the procedure.The two groups were evaluated for the following aspects:The total operative time,perforation rate,rate of whole mucosal resection,diameter of the peering mucosa,and scores of endoscopists’feelings with the procedure,including the convenience,mucosal surface exposure degree,and tissue tension.In addition,in the operational group,the soft tissue clip and the target magnet(TM)were connected by a thin wire through a small hole at the tail end of the TM.Under gastroscopic guidance,the soft tissue clip was clamped to the edge of the lesioned mucosa,which was marked in advance.By changing the position of the anchor magnet(AM)outside the esophagus,the pulling force and pulling direction of the TM could be changed,thus exposing the mucosal peeling surface and assisting the ESD.RESULTS Herein,each of the two groups comprised 10 isolated esophageal putative mucosal lesions.The diameter of the peering mucosa did not significantly differ between the two groups(2.13±0.06 vs 2.15±0.06,P=0.882).The total operative time was shorter in the operational group than in the control group(17.04±0.22 min vs 21.94±0.23 min,P<0.001).During the entire experiment,the TM remained firmly connected with the soft tissue clip and did not affect the opening,closing,and release of the soft tissue clip.The interaction between the TM and AM could provide sufficient tissue tension and completely expose the mucosa,which greatly assists the surgeon with the operation.There was no avulsion of the mucosa,and mucosal lesions were intact when peeled.Therefore,the scores of endoscopists’feelings were higher in the operational group than in the control group in terms of the convenience(9.22±0.19 vs 8.34±0.15,P=0.002),mucosal surface exposure degree(9.11±0.15 vs 8.25±0.12,P<0.001),and tissue tension(9.35±0.13 vs 8.02±0.17,P<0.001).The two groups did not significantly differ in the perforation rate and rate of whole mucosal resection.CONCLUSION We found MAT-assisted ESD safe and feasible for early esophageal cancer.It could greatly improve the endoscopic operation experience and showed good clinical application prospects.