期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Patient satisfaction and follow-up adherence to glaucoma case management clinic in China 被引量:1
1
作者 Hao Lin Hu-Jie Lu +3 位作者 Wen-Zhe Zhou shu-shu zuo Yan-Yan Chen Shao-Dan Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期73-81,共9页
AIM:To assess glaucoma patient satisfaction and follow-up adherence in case management and identify associated predictors to improve healthcare quality and patient outcomes.METHODS:In this cross-sectional study,a tota... AIM:To assess glaucoma patient satisfaction and follow-up adherence in case management and identify associated predictors to improve healthcare quality and patient outcomes.METHODS:In this cross-sectional study,a total of 119 patients completed a Patient Satisfaction Questionnaire-18 and a sociodemographic questionnaire.Clinical data was obtained from the case management system.Follow-up adherence was defined as completing each follow-up within±30d of the scheduled time set by ophthalmologists during the study period.RESULTS:Average satisfaction scored 78.65±7,with an average of 4.39±0.58 across the seven dimensions.Age negatively correlated with satisfaction(P=0.008),whilst patients with follow-up duration of 2 or more years reported higher satisfaction(P=0.045).Multivariate logistics regression analysis revealed that longer follow-up durations were associated with lower follow-up adherence(OR=0.97,95%CI,0.95-1.00,P=0.044).Additionally,patients with suspected glaucoma(OR=2.72,95%CI,1.03-7.20,P=0.044)and those with an annual income over 100000 Chinese yuan demonstrated higher adherence(OR=5.57,95%CI,1.00-30.89,P=0.049).CONCLUSION:The case management model proves effective for glaucoma patients,with positive adherence rates.The implementation of this model can be optimized in the future based on the identified factors and extended to glaucoma patients in more hospitals. 展开更多
关键词 GLAUCOMA patient satisfaction follow-up adherence case management
下载PDF
Two different autorefractors for vision screening in children and adolescents
2
作者 Xiao-Jun Chen Lin-Jie Liu +5 位作者 Bing Sun Dan-Dan Jiang shu-shu zuo Yan-Hui Wang Chun-Hua Zhang Yan-Yan Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期331-338,共8页
AIM:To compare the consistency of two autorefractors(Tianle RM-9000 and Topcon KR-800)for school-age myopia children,and to provide a basis for largescale data analysis and comparison.METHODS:The refractive error in 9... AIM:To compare the consistency of two autorefractors(Tianle RM-9000 and Topcon KR-800)for school-age myopia children,and to provide a basis for largescale data analysis and comparison.METHODS:The refractive error in 909 subjects(age 4–18y)were measured using both autorefractors without cycloplegia.The data were analyzed using Fourier decomposition and the correlation coefficients,intraclass correlation coefficients(ICC),and Bland-Altman limits of agreement(LoA)for each parameter were calculated.RESULTS:There was a strong correlation between the spherical equivalent(SE),sphere diopter(DS),and cylinder diopter(DC)readings of the Tianle RM-9000 and those of the Topcon KR-800,with correlation coefficient values of 0.98,0.98 and 0.83 and ICC values of 0.99,0.99 and 0.93,respectively.However,the correlation coefficients and ICC values of J0 and J45 were unreliable(R=-0.004,-0.034;both ICC<0.10).Bland-Altman analysis revealed that SE,DS,and DC measured by the Tianle RM-9000 were significantly biased toward myopia compared with the Topcon KR-800,and the mean differences were-0.072,-0.026,-0.091 D,respectively(all P<0.01).The minimum absolute value of the difference within the 95%LoA for SE,DS,and DC was 0.63 D,0.50 D,0.62 D,respectively;all these values were in the clinically acceptable range.For J0 and J45,the mean differences were close to zero(P=0.43,0.84);however,the 95%LoA were relatively wide(J0 SD:0.53;95%CI:-1.00,1.10;J45 SD:0.52;95%CI:-1.00,1.00).CONCLUSION:The two autorefractors are consistent with each other,as the differences in SE,DS,and DC were within the clinically acceptable range.Readers can compare the data measured by either device in different studies and use the two devices in the same study to generate a dataset that can be analyzed together.However,the J0 and J45 vectors are unreliable and should not be used to assess astigmatism. 展开更多
关键词 refractive error autorefractors school-age myopia children
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部