The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for...The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for voltage balancing between branches.To solve this problem,this paper defines sequence circulating components and theoretically analyzes the influence mechanism of different sequence circulating components on branch capacitor voltage.A fully decoupled branch energy balancing control method based on four groups of sequence circulating components is proposed.This method can control capacitor voltages of nine branches in horizontal,vertical and diagonal directions.Considering influences of both circulating current and voltage,a cross decoupled control is designed to improve control precision.Simulation results are taken from a low-frequency transmission system based on PSCAD/EMTDC,and effectiveness and precision of the proposed branch energy balancing control method are verified in the case of nonuniform parameters and an unbalanced power system.展开更多
The cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-...The cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-wire system.However,as the zero-sequence voltage is expressed in trigonometric form,traditional control methods involve many complicated operations,such as the square-root,trigonometric operations,and inverse tangent operations.To simplify cluster voltage balancing control,this paper converts the zero-sequence voltage to the dq frame in a DC representation by introducing a virtually orthogonal variable,and the DC components of the zero-sequence voltage in the dq frame are regulated linearly by proportional integral regulators,rather than being calculated from uneven active powers in traditional controls.This removes all complicated operations.Finally,this paper presents simulation and experimental results for a 400 V±7.5 kvar star-connected STATCOM,in balanced and unbalanced scenarios,thereby verifying the effectiveness of the proposed control.展开更多
基金supported by National Key R&D Program of China(No.2021YFB2401100).
文摘The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for voltage balancing between branches.To solve this problem,this paper defines sequence circulating components and theoretically analyzes the influence mechanism of different sequence circulating components on branch capacitor voltage.A fully decoupled branch energy balancing control method based on four groups of sequence circulating components is proposed.This method can control capacitor voltages of nine branches in horizontal,vertical and diagonal directions.Considering influences of both circulating current and voltage,a cross decoupled control is designed to improve control precision.Simulation results are taken from a low-frequency transmission system based on PSCAD/EMTDC,and effectiveness and precision of the proposed branch energy balancing control method are verified in the case of nonuniform parameters and an unbalanced power system.
基金supported by National Key R&D Program of China(No.2021YFB2401100)the Science and Technology Project of State Grid Corporation of China(No.5211DS22002C).
文摘The cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-wire system.However,as the zero-sequence voltage is expressed in trigonometric form,traditional control methods involve many complicated operations,such as the square-root,trigonometric operations,and inverse tangent operations.To simplify cluster voltage balancing control,this paper converts the zero-sequence voltage to the dq frame in a DC representation by introducing a virtually orthogonal variable,and the DC components of the zero-sequence voltage in the dq frame are regulated linearly by proportional integral regulators,rather than being calculated from uneven active powers in traditional controls.This removes all complicated operations.Finally,this paper presents simulation and experimental results for a 400 V±7.5 kvar star-connected STATCOM,in balanced and unbalanced scenarios,thereby verifying the effectiveness of the proposed control.