In order to ensure the safe operation of the compressors used in water chillers,in the present study some interlock protections have been added to the related design.These include a low pressure protection,a high pres...In order to ensure the safe operation of the compressors used in water chillers,in the present study some interlock protections have been added to the related design.These include a low pressure protection,a high pressure protection,an exhaust temperature protection and a differential pressure protection.Some tests have been conducted by tuning the saturation suction and exhaust temperatures of the compressor through adjustment of the cold source outlet temperature and the ambient temperature.The results show that the ambient temperature increases with decreasing device load and increasing fan speed under the same saturated suction temperature;the device refrigerating capacity steps up with augmenting load and dropping saturation exhaust temperature,while it is not greatly affected by the fan speed.Moreover,the Energy efficiency ratio(COP)decreases with the rise of the saturation exhaust temperature.This parameter is not affected much by the device load and fan speed at high saturation exhaust temperature,while it improves on increasing the device load and decreasing the fan speed at low saturation exhaust temperature.展开更多
The thermal transmission coefficient for a micro-ribbed tube has been determined using theoretical relationships and the outcomes of such calculations have been compared with experiments conducted using a R1234yf refr...The thermal transmission coefficient for a micro-ribbed tube has been determined using theoretical relationships and the outcomes of such calculations have been compared with experiments conducted using a R1234yf refrigerant undergoing condensation.In particular four theoretical single-phase flow and three multi-phase flow models have been used in this regard.The experimental results show that:the Oliver et al.criterion equation overestimates the experimental results as its accuracy is significantly affected by the specific conditions realized inside micro-fin tubes;the Miyara et al.criterion equation prediction error is less than 15%;the Cavallini et al.approach gives the highest prediction accuracy;the Goto et al.model overestimates the test data.Such results are critically discussed and some indications for the improvement of such models are provided.展开更多
The performances of a refrigeration unit relying on compressors working in parallel have been investigated considering the influence of the compressor volumetric efficiency and isentropic efficiency on the compression...The performances of a refrigeration unit relying on compressors working in parallel have been investigated considering the influence of the compressor volumetric efficiency and isentropic efficiency on the compression ratio.Moreover,the following influential factors have been taken into account:evaporation temperature,condensation temperature and compressor suction-exhaust pressure ratio for different opening conditions of the compressor.The following quantities have been selected as the unit performance measurement indicators:refrigeration capacity,energy efficiency ratio(COP),compressor power consumption,and refrigerant flow rate.The experimental results indicate that the system refrigeration capacity and COP decrease with a decrease in evaporation temperature,increase of condensation temperature,and increase in pressure ratio.The refrigerant flow rate increases with the increase in evaporation temperature,decrease in condensing temperature and increase in pressure ratio.The compressor power consumption increases with the increase in condensing temperature and increase in pressure ratio,but is not significantly affected by the evaporation temperature.展开更多
Experiments about heat transfer in the presence of a two-phase flow due to the condensation of a R1234yf refrigerant have been performed considering a smooth tube and two micro-fin tubes.The following experimental con...Experiments about heat transfer in the presence of a two-phase flow due to the condensation of a R1234yf refrigerant have been performed considering a smooth tube and two micro-fin tubes.The following experimental conditions have been considered:Condensation temperatures of 40℃,43℃ and 45℃,mass fluxes of 500–900 kg/(m^(2)·s),vapor qualities at the inlet and outlet of the heat transfer tube in the ranges 0.8–0.9 and 0.2–0.3,respectively.These tests have shown that:(1)The heat transfer coefficient increases with decreasing the condensation temperature and on increasing the mass flux;(2)The heat transfer coefficient inside the micro-fin tube is larger than that for the smooth tube;(3)The heat transfer enhancement factors for the micro-fin tube with a fin helical angle of 8°and 15°are 2.51–2.89 and 3.11–3.57,respectively;both are higher than the area increase ratio.These experimental results have been compared with correlations available in the literature:the Cavallini et al.correlation has the highest accuracy in predicting the heat transfer coefficient inside the smooth tube,the related percentage error and the average prediction error are±8%and 0.56%,respectively;for the micro-fin tube these become±25%and 6%,respectively.展开更多
基金This work was supported by the National Natural Science Foundation of China(No.41877251)Major Science and Technology Projects of Xinxiang City(No.21ZD012).
文摘In order to ensure the safe operation of the compressors used in water chillers,in the present study some interlock protections have been added to the related design.These include a low pressure protection,a high pressure protection,an exhaust temperature protection and a differential pressure protection.Some tests have been conducted by tuning the saturation suction and exhaust temperatures of the compressor through adjustment of the cold source outlet temperature and the ambient temperature.The results show that the ambient temperature increases with decreasing device load and increasing fan speed under the same saturated suction temperature;the device refrigerating capacity steps up with augmenting load and dropping saturation exhaust temperature,while it is not greatly affected by the fan speed.Moreover,the Energy efficiency ratio(COP)decreases with the rise of the saturation exhaust temperature.This parameter is not affected much by the device load and fan speed at high saturation exhaust temperature,while it improves on increasing the device load and decreasing the fan speed at low saturation exhaust temperature.
基金supported by the National Natural Science Foundation of China(No.41877251)Major Science and Technology Projects of Xinxiang City(No.21ZD012).
文摘The thermal transmission coefficient for a micro-ribbed tube has been determined using theoretical relationships and the outcomes of such calculations have been compared with experiments conducted using a R1234yf refrigerant undergoing condensation.In particular four theoretical single-phase flow and three multi-phase flow models have been used in this regard.The experimental results show that:the Oliver et al.criterion equation overestimates the experimental results as its accuracy is significantly affected by the specific conditions realized inside micro-fin tubes;the Miyara et al.criterion equation prediction error is less than 15%;the Cavallini et al.approach gives the highest prediction accuracy;the Goto et al.model overestimates the test data.Such results are critically discussed and some indications for the improvement of such models are provided.
基金supported by the National Natural Science Foundation of China(No.41877251)the Key project of Natural Science Foundation of Tianjin City(No.6JCZDJC39000).
文摘The performances of a refrigeration unit relying on compressors working in parallel have been investigated considering the influence of the compressor volumetric efficiency and isentropic efficiency on the compression ratio.Moreover,the following influential factors have been taken into account:evaporation temperature,condensation temperature and compressor suction-exhaust pressure ratio for different opening conditions of the compressor.The following quantities have been selected as the unit performance measurement indicators:refrigeration capacity,energy efficiency ratio(COP),compressor power consumption,and refrigerant flow rate.The experimental results indicate that the system refrigeration capacity and COP decrease with a decrease in evaporation temperature,increase of condensation temperature,and increase in pressure ratio.The refrigerant flow rate increases with the increase in evaporation temperature,decrease in condensing temperature and increase in pressure ratio.The compressor power consumption increases with the increase in condensing temperature and increase in pressure ratio,but is not significantly affected by the evaporation temperature.
基金supported by the National Natural Science Foundation of China(No.41877251).
文摘Experiments about heat transfer in the presence of a two-phase flow due to the condensation of a R1234yf refrigerant have been performed considering a smooth tube and two micro-fin tubes.The following experimental conditions have been considered:Condensation temperatures of 40℃,43℃ and 45℃,mass fluxes of 500–900 kg/(m^(2)·s),vapor qualities at the inlet and outlet of the heat transfer tube in the ranges 0.8–0.9 and 0.2–0.3,respectively.These tests have shown that:(1)The heat transfer coefficient increases with decreasing the condensation temperature and on increasing the mass flux;(2)The heat transfer coefficient inside the micro-fin tube is larger than that for the smooth tube;(3)The heat transfer enhancement factors for the micro-fin tube with a fin helical angle of 8°and 15°are 2.51–2.89 and 3.11–3.57,respectively;both are higher than the area increase ratio.These experimental results have been compared with correlations available in the literature:the Cavallini et al.correlation has the highest accuracy in predicting the heat transfer coefficient inside the smooth tube,the related percentage error and the average prediction error are±8%and 0.56%,respectively;for the micro-fin tube these become±25%and 6%,respectively.