The present work deals with the study of the thermal performances of a convective dryer for fruits and vegetables. This dryer, operating with energy generated from the combustion of biomass in a boiler connected to a ...The present work deals with the study of the thermal performances of a convective dryer for fruits and vegetables. This dryer, operating with energy generated from the combustion of biomass in a boiler connected to a water/air heat exchanger could be a solution to the problematic of energy related to drying. An experimental and theoretical study is carried out on the temperature profile inside the dryer. For this purpose, 10.3 kg of tomatoes were dried on the experimental setup. The operation lasted about 16 hours and reduced the moisture content from 93.8% to 12% in wet basis. The overall thermal efficiency of the convective dryer during the trial is 10.76%. For the theoretical study, the dryer components (boiler, water/air exchanger and drying chamber) are first modeled individually;the different sub-programs are then coupled to form the convective dryer program. The method of global heat balances combined with the one called “ε-NUT” is used. The set of equations is discretized using the implicit method of finite differences, then solved with the Gauss algorithm in Fortran 90. The theoretical results obtained are in good agreement with those measured.展开更多
The purpose of this study is to experimentally analyze the thermal behavior of the walls of a prototype experimental house. A Datalogger and thermocouples were used on the experimental house to determine the temperatu...The purpose of this study is to experimentally analyze the thermal behavior of the walls of a prototype experimental house. A Datalogger and thermocouples were used on the experimental house to determine the temperatures of the exterior and interior walls. Also, “MSR” type HygroPuce was used to determine the exterior and interior temperatures and relative humidity of the habitat. The results show that a wall made of bio-based materials with a mixture of “earth + Hibiscus cannabinus L. fibers” allows reducing the fluctuations of the interior temperatures. We observe the peaks of temperatures on the external walls at 11:00 am and for the interior walls, the peaks are observed at 5:00 pm. The maximum thermal phase shift between the peaks of the external and internal temperatures is about 7.5 hours, and the maximum damping factor is 0.9. Also, we note that the thermal performance of the material used in the design of the envelope of the house is determined by the improvement of the response of the envelope in front of the external thermal solicitations.展开更多
文摘The present work deals with the study of the thermal performances of a convective dryer for fruits and vegetables. This dryer, operating with energy generated from the combustion of biomass in a boiler connected to a water/air heat exchanger could be a solution to the problematic of energy related to drying. An experimental and theoretical study is carried out on the temperature profile inside the dryer. For this purpose, 10.3 kg of tomatoes were dried on the experimental setup. The operation lasted about 16 hours and reduced the moisture content from 93.8% to 12% in wet basis. The overall thermal efficiency of the convective dryer during the trial is 10.76%. For the theoretical study, the dryer components (boiler, water/air exchanger and drying chamber) are first modeled individually;the different sub-programs are then coupled to form the convective dryer program. The method of global heat balances combined with the one called “ε-NUT” is used. The set of equations is discretized using the implicit method of finite differences, then solved with the Gauss algorithm in Fortran 90. The theoretical results obtained are in good agreement with those measured.
文摘The purpose of this study is to experimentally analyze the thermal behavior of the walls of a prototype experimental house. A Datalogger and thermocouples were used on the experimental house to determine the temperatures of the exterior and interior walls. Also, “MSR” type HygroPuce was used to determine the exterior and interior temperatures and relative humidity of the habitat. The results show that a wall made of bio-based materials with a mixture of “earth + Hibiscus cannabinus L. fibers” allows reducing the fluctuations of the interior temperatures. We observe the peaks of temperatures on the external walls at 11:00 am and for the interior walls, the peaks are observed at 5:00 pm. The maximum thermal phase shift between the peaks of the external and internal temperatures is about 7.5 hours, and the maximum damping factor is 0.9. Also, we note that the thermal performance of the material used in the design of the envelope of the house is determined by the improvement of the response of the envelope in front of the external thermal solicitations.