Energy Consumption Monitoring Analysis for Residential, Educational and Public Buildings 被引量:1
1
作者 Allan Hani teet-andrus koiv 《Smart Grid and Renewable Energy》 2012年第3期231-238,共8页
In the present article thermal and electrical energy consumptions for different types of buildings are analyzed. The latitude and longitude of the researched area are defined 59?00'N and 26?00'E. According to ... In the present article thermal and electrical energy consumptions for different types of buildings are analyzed. The latitude and longitude of the researched area are defined 59?00'N and 26?00'E. According to K?ppen climate classification the area is located in warm summer continental climate. The study consist 40 residential, 7 educational and 44 public buildings. Three years data for each building type among 2006-2011 was used. Several detailed energy balances are presented for apartment buildings. In addition the different ways of domestic hot water preparation are analyzed for apartment buildings. The school buildings average consumption values are represented in study. Also valuable information of measured electrical energy consumption balance for a new office building is presented. Finally there is included the energy consumption analysis of public buildings. 展开更多
关键词 Specific ENERGY CONSUMPTION Thermal ENERGY Electrical ENERGY RESIDENTIAL BUILDINGS EDUCATIONAL BUILDINGS OFFICE BUILDINGS
下载PDF
The Efficiency Analysis of the Exhaust Air Heat Pump System 被引量:1
2
作者 Alo Mikola teet-andrus koiv 《Engineering(科研)》 2014年第13期1037-1045,共9页
This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air h... This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5. 展开更多
关键词 Heat Pump Exhaust Air Heat Pump Heat Recovery Heat Requirement COP The Coefficient of Performance
下载PDF
The Application of the Ground Source and Air-to-Water Heat Pumps in Cold Climate Areas 被引量:3
3
作者 Kaspar Tennokese teet-andrus koiv +1 位作者 Alo Mikola Villu Vares 《Smart Grid and Renewable Energy》 2013年第7期473-481,共9页
This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulati... This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulation and analysis were carried out for a typical detached house, with 200 m2 of living area, the heat demand of 9 kW and the average heat demand for DHW production of 1 kW. In heating period the average Coefficient of Performance (COP) of the A&WHP is considerably lower than COP of the GSHP. 展开更多
关键词 Ground Source Heat Pump Air-Water Heat Pump Heat Requirement COP
下载PDF
DHW Design Flow Rates and Consumption Profiles in Educational, Office Buildings and Shopping Centres
4
作者 teet-andrus koiv Alo Mikola Alvar Toode 《Smart Grid and Renewable Energy》 2013年第3期287-296,共10页
The paper gives a thorough survey of the studies of different authors in the field of domestic hot water (DHW) consumption and consumption profiles. It presents an overview of the research done into DHW by the Tallinn... The paper gives a thorough survey of the studies of different authors in the field of domestic hot water (DHW) consumption and consumption profiles. It presents an overview of the research done into DHW by the Tallinn University of Technology. Working out on the basis of investigations has been new empirical formulas for determining design flow rates for schools, kindergartens, office buildings and shopping centres. DHW consumption profiles of typical buildings are presented. Comparisons are given on the determination of DHW design flow rates by the standard EVS 835, the EN 806-3 and the recommended formulas. The latter makes it possible to considerably decrease the design flow rates which in turn enables to deminish the load of the equipment, to improve the quality of control and to decrease the diameters of the pipes of the district heating network and the losses of heat in them. 展开更多
关键词 DHW DHW DESIGN Flow Rate SCHOOLS Kindergartens Office Buildings SHOPPING Centres CONSUMPTION Profiles
下载PDF
Ventilation Solutions in Renovated Apartment Buildings in Cold Climate Conditions
5
作者 teet-andrus koiv Alo Mikola Raimo Simson 《Engineering(科研)》 2015年第3期129-139,共11页
Different solutions of renovating the ventilation in apartment buildings have been researched. The analysis shows that the use of heat recovery in cold climate regions is essential. Central as well as apartment- and r... Different solutions of renovating the ventilation in apartment buildings have been researched. The analysis shows that the use of heat recovery in cold climate regions is essential. Central as well as apartment- and room-based solutions with heat recovery have been studied. Balanced ventilation is suitable for small (2 - 3-storey) apartment buildings with a suitable room solution for apartments. In larger apartment buildings, the system with the exhaust air heat pump could be used. This is particularly suitable for apartment buildings with mechanical exhaust ventilation. In small apartments, it is most suitable to use room-based air handling units (AHUs) with the recuperative heat exchanger, plus exhaust ventilators in the WC, bathroom and kitchen. The economic indicators of this system are best for two-room apartments. Apartment-based AHUs are suitable for large apartments if there is no opposition from the residents, which is caused by ventilation tubes (ducts) in the apartment. The comparison of the reduced energy cost in case of different AHUs has been presented for small apartment buildings. 展开更多
关键词 AHU Heat RECOVERY AIR CHANGE ENERGY Calculation for AIR HEATING ENERGY Efficiency of AHU
下载PDF
The Preliminary Research of Sea Water District Heating and Cooling for Tallinn Coastal Area
6
作者 Allan Hani teet-andrus koiv 《Smart Grid and Renewable Energy》 2012年第3期246-252,共7页
This paper describes possibilities to utilize sea water for district heating and cooling purposes in Tallinn costal area. The sea water temperature profiles and suitability of heating and cooling generation are studie... This paper describes possibilities to utilize sea water for district heating and cooling purposes in Tallinn costal area. The sea water temperature profiles and suitability of heating and cooling generation are studied for continental climatic conditions. The district network study bases on 21 buildings located near to the Gulf of Finland. Industrial reversible heat pump technology is selected to cover heating and cooling loads for the new buildings. Combination of existing district heating and heat pump technology is considered for existing buildings. The results show possibilities, threats and need for further research of the sea water based heat pump district network implementation. 展开更多
关键词 DISTRICT HEATING COOLING SEA Water Heat PUMP RENEWABLE Energy Office Building
下载PDF
Ventilation of Apartment Buildings and Nursing Homes
7
作者 Alo Mikola teet-andrus koiv Hendrik Voll 《Smart Grid and Renewable Energy》 2014年第5期107-119,共13页
The paper presents the results of the investigations into the indoor climate and energy efficiency of ventilation devices in residential buildings and nursing homes. The indoor climate studies discussed in the article... The paper presents the results of the investigations into the indoor climate and energy efficiency of ventilation devices in residential buildings and nursing homes. The indoor climate studies discussed in the article were conducted in a nursing home where room ventilation is based on Meltem Air Handling Units (AHU). Similar studies have been carried out in apartment buildings where CO2 levels in bedrooms were compared before and after renovating the ventilation with Meltem AHU and installing exhaust fans in the bathroom/WC and kitchen. Tenants evaluate the use of Meltem AHU in apartments very positively. The article presents the efficiency results of Meltem AHU with different external air temperatures conducted in apartments in real-life situations. The study shows that skilful renovation of ventilation in old apartment buildings enables to achieve good indoor climate and energy saving at the same time. 展开更多
关键词 INDOOR CLIMATE APARTMENT Buildings NURSING HOME AHU Energy Efficiency of AHU
下载PDF
Optimization of Office Building Façades in a Warm Summer Continental Climate
8
作者 Allan Hani teet-andrus koiv 《Smart Grid and Renewable Energy》 2012年第3期222-230,共9页
A typical office building model with conventional use and contemporary building systems was developed for fa?ade optimization in continental climate. Wall, glazing area and window parameters were taken as the main var... A typical office building model with conventional use and contemporary building systems was developed for fa?ade optimization in continental climate. Wall, glazing area and window parameters were taken as the main variables. The objective function of optimization task described in this article is the minimization of cooling and heating energy con-sumption. The office building fa?ades optimization was carried out using a combination of IDA Indoor Climate and Energy 4.5 and GenOpt. The process is described in detail so that the approach may be emulated. A hybrid multidimen-sional optimization algorithm GPSPSOCCHJ was used in calculation process. The optimization results are presented in four quick selection charts to assist architects, designers and real estate developers make suitable early stage fa?ade selection decisions. 展开更多
关键词 OPTIMIZATION ENVELOPE Design Passive Solar Control Energy Efficiency Office Building
下载PDF