AIM:To investigate whether a noninvasive measurement of tissue strain has a potential usefulness for management of nonalcoholic steatohepatitis(NASH).METHODS:In total 26 patients,23 NASHs and 3 normal controls were en...AIM:To investigate whether a noninvasive measurement of tissue strain has a potential usefulness for management of nonalcoholic steatohepatitis(NASH).METHODS:In total 26 patients,23 NASHs and 3 normal controls were enrolled in this study.NASH was staged based on Brunt criterion.At a region of interest(ROI),a shear wave was evoked by implementing an acoustic radiation force impulse(ARFI),and the propagation velocity was quantif ied.RESULTS:Shear wave velocity(SWV) could be reproducibly quantified at all ROIs in all subjects except for 4 NASH cases,in which a reliable SWV value was not calculated at several ROIs.An average SWV of 1.34 ± 0.26 m/s in fibrous stage 0-1 was significantly slower than 2.20 ± 0.74 m/s and 2.90 ± 1.01 m/s in stages 3 and 4,respectively,but was not significantly different from 1.79 ± 0.78 m/s in stage 2.When a cutoff value was set at 1.47 m/s,receiver operating characteristic analysis showed significance to dissociate stages 3 and 4 from stage 0-1(P=0.0092) with sensitivity,specificity and area under curve of 100%,75% and 94.2%,respectively.In addition,the correlation between SWV and hyaluronic acid was significant(P<0.0001),while a tendency toward negative correlation was observed with serum albumin(P=0.053).CONCLUSION:The clinical implementation of ARFI provides noninvasive repeated evaluations of liver stiffness at an arbitrary position,which has the potential to shed new light on NASH management.展开更多
文摘AIM:To investigate whether a noninvasive measurement of tissue strain has a potential usefulness for management of nonalcoholic steatohepatitis(NASH).METHODS:In total 26 patients,23 NASHs and 3 normal controls were enrolled in this study.NASH was staged based on Brunt criterion.At a region of interest(ROI),a shear wave was evoked by implementing an acoustic radiation force impulse(ARFI),and the propagation velocity was quantif ied.RESULTS:Shear wave velocity(SWV) could be reproducibly quantified at all ROIs in all subjects except for 4 NASH cases,in which a reliable SWV value was not calculated at several ROIs.An average SWV of 1.34 ± 0.26 m/s in fibrous stage 0-1 was significantly slower than 2.20 ± 0.74 m/s and 2.90 ± 1.01 m/s in stages 3 and 4,respectively,but was not significantly different from 1.79 ± 0.78 m/s in stage 2.When a cutoff value was set at 1.47 m/s,receiver operating characteristic analysis showed significance to dissociate stages 3 and 4 from stage 0-1(P=0.0092) with sensitivity,specificity and area under curve of 100%,75% and 94.2%,respectively.In addition,the correlation between SWV and hyaluronic acid was significant(P<0.0001),while a tendency toward negative correlation was observed with serum albumin(P=0.053).CONCLUSION:The clinical implementation of ARFI provides noninvasive repeated evaluations of liver stiffness at an arbitrary position,which has the potential to shed new light on NASH management.