In order to achieve the auto-timing counts measurement of nuclear radiation using ORTEC 974 Counter/Timer, an auto-timing counts virtual instrument system based on the LabVIEW virtual instrument development platform a...In order to achieve the auto-timing counts measurement of nuclear radiation using ORTEC 974 Counter/Timer, an auto-timing counts virtual instrument system based on the LabVIEW virtual instrument development platform and GPIB instrument control and transmission bus protocol is designed in this paper. By introducing software timing technique, the minimum time base of factory setting improves from 0.1 s to 0.03 s. The timing counts performance and longtime stability are also discussed in detail. The automatic data recording and saving facilitates data analysis and processing. Its real-time display and statistic function is very convenient for monitoring the nuclear radiation.展开更多
Purpose Back-n is a white neutron beamline at China spallation neutron source,which was established in the year of 2018.It is a powerful facility for nuclear data measurement,neutron detector calibration,and radiation...Purpose Back-n is a white neutron beamline at China spallation neutron source,which was established in the year of 2018.It is a powerful facility for nuclear data measurement,neutron detector calibration,and radiation effect research.Method A series of detectors were built for different experiments,including beam monitoring,beam profile measurement,neutron induced secondaries(fission fragments,light charged particles and gamma)cross section measurement,and neutron resonance radiography,etc.A common digitization electronics and a cluster-based DAQ were developed for these detector systems.Most detectors have been employed at Back-n and serviced for experiments from the beginning of the beamline running.Results and conclusion As an overview of detectors of Back-n,the details of the detector design and the experiment performing are described in this paper.Some developing systems,e.g.,MTPC and B-MCP,are also included.展开更多
文摘In order to achieve the auto-timing counts measurement of nuclear radiation using ORTEC 974 Counter/Timer, an auto-timing counts virtual instrument system based on the LabVIEW virtual instrument development platform and GPIB instrument control and transmission bus protocol is designed in this paper. By introducing software timing technique, the minimum time base of factory setting improves from 0.1 s to 0.03 s. The timing counts performance and longtime stability are also discussed in detail. The automatic data recording and saving facilitates data analysis and processing. Its real-time display and statistic function is very convenient for monitoring the nuclear radiation.
基金support provided by the National KeyR&DProgram of China(Grant No.2016YFA0401600).
文摘Purpose Back-n is a white neutron beamline at China spallation neutron source,which was established in the year of 2018.It is a powerful facility for nuclear data measurement,neutron detector calibration,and radiation effect research.Method A series of detectors were built for different experiments,including beam monitoring,beam profile measurement,neutron induced secondaries(fission fragments,light charged particles and gamma)cross section measurement,and neutron resonance radiography,etc.A common digitization electronics and a cluster-based DAQ were developed for these detector systems.Most detectors have been employed at Back-n and serviced for experiments from the beginning of the beamline running.Results and conclusion As an overview of detectors of Back-n,the details of the detector design and the experiment performing are described in this paper.Some developing systems,e.g.,MTPC and B-MCP,are also included.