In this paper, we introduce the notion of a (2+1)-dimenslonal differential equation describing three-dimensional hyperbolic spaces (3-h.s.). The (2+1)-dimensional coupled nonlinear Schrodinger equation and its...In this paper, we introduce the notion of a (2+1)-dimenslonal differential equation describing three-dimensional hyperbolic spaces (3-h.s.). The (2+1)-dimensional coupled nonlinear Schrodinger equation and its sister equation, the (2+1)-dimensional coupled derivative nonlinear Schrodinger equation, are shown to describe 3-h.s, The (2 + 1 )-dimensional generalized HF model:St=(1/2i[S,Sy]+2iσS)x,σx=-1/4i tr(SSxSy), in which S ∈ GLc(2)/GLc(1)×GLc(1),provides another example of (2+1)-dimensional differential equations describing 3-h.s. As a direct con-sequence, the geometric construction of an infinire number of conservation lairs of such equations is illustrated. Furthermore we display a new infinite number of conservation lairs of the (2+1)-dimensional nonlinear Schrodinger equation and the (2+1)-dimensional derivative nonlinear Schrodinger equation by a geometric way.展开更多
Inductively coupled plasma optical emission spectrometric approach(1CP-OES) is used to determine the potassium content as principal component in pyrotechnic compositions used for fireworks and firecrackers. Element ...Inductively coupled plasma optical emission spectrometric approach(1CP-OES) is used to determine the potassium content as principal component in pyrotechnic compositions used for fireworks and firecrackers. Element of potassium is conunonly found in potassium nitrate and potassium perchlorate in pyrotechnic compositions in fireworks and firecrackers. Statistical analysis shows that potassium nitrate content in pyrotechnics is between 10% to 60% and the potassium perchlorate content is between 20% to 70%,which counted in the content of potassium element is between 4% to 23%. Concept of this method: considering the weight of the sample is 400rag,constant volume is 1L and the concentration of potassium is between 10 mg/L to 90 mg/L in sample solution, the determination scope of the method for the potassium content would be between 1% to 23%.Further experiments proved that the fitting correlation coefficient of potassium calibration curve is 0.9997 or higher, recovery is 89.15%-100.23%.The allowable differential value is 0.4% between two single tests under repeatable conditions. This method can completely satisfy the requirements of the fireworks and firecrackers industry with high accuracy and good precision.展开更多
基金The project partially supported by National Natural Science Foundation of China
文摘In this paper, we introduce the notion of a (2+1)-dimenslonal differential equation describing three-dimensional hyperbolic spaces (3-h.s.). The (2+1)-dimensional coupled nonlinear Schrodinger equation and its sister equation, the (2+1)-dimensional coupled derivative nonlinear Schrodinger equation, are shown to describe 3-h.s, The (2 + 1 )-dimensional generalized HF model:St=(1/2i[S,Sy]+2iσS)x,σx=-1/4i tr(SSxSy), in which S ∈ GLc(2)/GLc(1)×GLc(1),provides another example of (2+1)-dimensional differential equations describing 3-h.s. As a direct con-sequence, the geometric construction of an infinire number of conservation lairs of such equations is illustrated. Furthermore we display a new infinite number of conservation lairs of the (2+1)-dimensional nonlinear Schrodinger equation and the (2+1)-dimensional derivative nonlinear Schrodinger equation by a geometric way.
文摘Inductively coupled plasma optical emission spectrometric approach(1CP-OES) is used to determine the potassium content as principal component in pyrotechnic compositions used for fireworks and firecrackers. Element of potassium is conunonly found in potassium nitrate and potassium perchlorate in pyrotechnic compositions in fireworks and firecrackers. Statistical analysis shows that potassium nitrate content in pyrotechnics is between 10% to 60% and the potassium perchlorate content is between 20% to 70%,which counted in the content of potassium element is between 4% to 23%. Concept of this method: considering the weight of the sample is 400rag,constant volume is 1L and the concentration of potassium is between 10 mg/L to 90 mg/L in sample solution, the determination scope of the method for the potassium content would be between 1% to 23%.Further experiments proved that the fitting correlation coefficient of potassium calibration curve is 0.9997 or higher, recovery is 89.15%-100.23%.The allowable differential value is 0.4% between two single tests under repeatable conditions. This method can completely satisfy the requirements of the fireworks and firecrackers industry with high accuracy and good precision.