Aqueous zinc metal batteries(AZMBs)are promising candidates for next-generation energy storage due to the excellent safety, environmental friendliness, natural abundance, high theoretical specific capacity, and low re...Aqueous zinc metal batteries(AZMBs)are promising candidates for next-generation energy storage due to the excellent safety, environmental friendliness, natural abundance, high theoretical specific capacity, and low redox potential of zinc(Zn) metal. However,several issues such as dendrite formation, hydrogen evolution, corrosion, and passivation of Zn metal anodes cause irreversible loss of the active materials. To solve these issues, researchers often use large amounts of excess Zn to ensure a continuous supply of active materials for Zn anodes. This leads to the ultralow utilization of Zn anodes and squanders the high energy density of AZMBs. Herein, the design strategies for AZMBs with high Zn utilization are discussed in depth, from utilizing thinner Zn foils to constructing anode-free structures with theoretical Zn utilization of 100%, which provides comprehensive guidelines for further research. Representative methods for calculating the depth of discharge of Zn anodes with different structures are first summarized. The reasonable modification strategies of Zn foil anodes, current collectors with pre-deposited Zn, and anode-free aqueous Zn metal batteries(AF-AZMBs) to improve Zn utilization are then detailed. In particular, the working mechanism of AF-AZMBs is systematically introduced. Finally, the challenges and perspectives for constructing high-utilization Zn anodes are presented.展开更多
基于海上移动平台GNSS动态精密单点定位技术(precise point positioning,PPP),对海洋上空可降水量(precipitable water vapor,PWV)探测的影响因素进行了研究,主要分析了采样间隔,卫星截止高度角,PPP解算方式(固定解或浮点解)以及有无北...基于海上移动平台GNSS动态精密单点定位技术(precise point positioning,PPP),对海洋上空可降水量(precipitable water vapor,PWV)探测的影响因素进行了研究,主要分析了采样间隔,卫星截止高度角,PPP解算方式(固定解或浮点解)以及有无北斗卫星系统组合对海洋PWV反演的影响。结果显示,采样间隔为30 s时,PWV反演的精度最高;可用卫星数较少的情况下,截止高度角设为5°~10°时,PWV反演精度更优,随着卫星截止高度角的增大,反演精度逐渐降低;定位解是否固定对PWV反演精度影响较小;在GPS GLONASS系统组合的基础上,加入北斗卫星观测值,将提高观测的冗余度,有利于PWV反演精度的提高。展开更多
BACKGROUND Endoscopic submucosal dissection (ESD) has been routinely performed in applicable early gastric cancer (EGC) patients as an alternative to conventional surgical operations that involve lymph node dissection...BACKGROUND Endoscopic submucosal dissection (ESD) has been routinely performed in applicable early gastric cancer (EGC) patients as an alternative to conventional surgical operations that involve lymph node dissection. The indications for ESD have been recently expanded to include larger, ulcerated, and undifferentiated mucosal lesions, and differentiated lesions with slight submucosal invasion. The risk of lymph node metastasis (LNM) is the most important consideration when deciding on a treatment strategy for EGC. Despite the advantages over surgical procedures, lymph nodes cannot be removed by ESD. In addition, whether patients who meet the expanded indications for ESD can be managed safely remains controversial. AIM To determine whether the ESD indications are applicable to Chinese patients and to investigate the predictors of LNM in EGC. METHODS We retrospectively analyzed 12552 patients who underwent surgery for gastric cancer between June 2007 and December 2018 at the Affiliated Hospital of Qingdao University. A total of 1262 (10.1%) EGC patients were eligible for inclusion in this study. Data on the patients’ clinical, endoscopic, and histopathological characteristics were collected. The absolute and expanded indications for ESD were validated by regrouping the enrolled patients and determining the positive LNM results in each subgroup. Predictors of LNM in patients were evaluated by univariate and multivariate analyses. RESULTS LNM was observed in 182 (14.4%) patients. No LNM was detected in the patients who met the absolute indications (0/90). LNM occurred in 4/311 (1.3%) patients who met the expanded indications. According to univariate analysis, LNM was significantly associated with positive tumor marker status, medium (20-30 mm) and large (>30 mm) lesion sizes, excavated macroscopic-type tumors, ulcer presence, submucosal invasion (SM1 and SM2), poor differentiation, lymphovascular invasion (LVI), perineural invasion, and diffuse and mixed Lauren’s types. Multivariate analysis demonstrated SM1 invasion (odds ration [OR]= 2.285, P = 0.03), SM2 invasion (OR = 3.230, P < 0.001), LVI (OR = 15.702, P < 0.001), mucinous adenocarcinoma (OR = 2.823, P = 0.015), and large lesion size (OR = 1.900, P = 0.006) to be independent risk factors. CONCLUSION The absolute indications for ESD are reasonable, and the feasibility of expanding the indications for ESD requires further investigation. The predictors of LNM include invasion depth, LVI, mucinous adenocarcinoma, and lesion size.展开更多
基金the financial support from the National Natural Science Foundation of China (Grant Nos. 52201201, 52372171)the State Key Lab of Advanced Metals and Materials (Grant No. 2022Z-11)+1 种基金the Fundamental Research Funds for the Central Universities (Grant No. 00007747, 06500205)the Initiative Postdocs Supporting Program (Grant No. BX20190002)。
文摘Aqueous zinc metal batteries(AZMBs)are promising candidates for next-generation energy storage due to the excellent safety, environmental friendliness, natural abundance, high theoretical specific capacity, and low redox potential of zinc(Zn) metal. However,several issues such as dendrite formation, hydrogen evolution, corrosion, and passivation of Zn metal anodes cause irreversible loss of the active materials. To solve these issues, researchers often use large amounts of excess Zn to ensure a continuous supply of active materials for Zn anodes. This leads to the ultralow utilization of Zn anodes and squanders the high energy density of AZMBs. Herein, the design strategies for AZMBs with high Zn utilization are discussed in depth, from utilizing thinner Zn foils to constructing anode-free structures with theoretical Zn utilization of 100%, which provides comprehensive guidelines for further research. Representative methods for calculating the depth of discharge of Zn anodes with different structures are first summarized. The reasonable modification strategies of Zn foil anodes, current collectors with pre-deposited Zn, and anode-free aqueous Zn metal batteries(AF-AZMBs) to improve Zn utilization are then detailed. In particular, the working mechanism of AF-AZMBs is systematically introduced. Finally, the challenges and perspectives for constructing high-utilization Zn anodes are presented.
文摘基于海上移动平台GNSS动态精密单点定位技术(precise point positioning,PPP),对海洋上空可降水量(precipitable water vapor,PWV)探测的影响因素进行了研究,主要分析了采样间隔,卫星截止高度角,PPP解算方式(固定解或浮点解)以及有无北斗卫星系统组合对海洋PWV反演的影响。结果显示,采样间隔为30 s时,PWV反演的精度最高;可用卫星数较少的情况下,截止高度角设为5°~10°时,PWV反演精度更优,随着卫星截止高度角的增大,反演精度逐渐降低;定位解是否固定对PWV反演精度影响较小;在GPS GLONASS系统组合的基础上,加入北斗卫星观测值,将提高观测的冗余度,有利于PWV反演精度的提高。
基金Supported by the National Natural Science Foundation of China,No.81502025the China Postdoctoral Science Foundation,No.2018M632631
文摘BACKGROUND Endoscopic submucosal dissection (ESD) has been routinely performed in applicable early gastric cancer (EGC) patients as an alternative to conventional surgical operations that involve lymph node dissection. The indications for ESD have been recently expanded to include larger, ulcerated, and undifferentiated mucosal lesions, and differentiated lesions with slight submucosal invasion. The risk of lymph node metastasis (LNM) is the most important consideration when deciding on a treatment strategy for EGC. Despite the advantages over surgical procedures, lymph nodes cannot be removed by ESD. In addition, whether patients who meet the expanded indications for ESD can be managed safely remains controversial. AIM To determine whether the ESD indications are applicable to Chinese patients and to investigate the predictors of LNM in EGC. METHODS We retrospectively analyzed 12552 patients who underwent surgery for gastric cancer between June 2007 and December 2018 at the Affiliated Hospital of Qingdao University. A total of 1262 (10.1%) EGC patients were eligible for inclusion in this study. Data on the patients’ clinical, endoscopic, and histopathological characteristics were collected. The absolute and expanded indications for ESD were validated by regrouping the enrolled patients and determining the positive LNM results in each subgroup. Predictors of LNM in patients were evaluated by univariate and multivariate analyses. RESULTS LNM was observed in 182 (14.4%) patients. No LNM was detected in the patients who met the absolute indications (0/90). LNM occurred in 4/311 (1.3%) patients who met the expanded indications. According to univariate analysis, LNM was significantly associated with positive tumor marker status, medium (20-30 mm) and large (>30 mm) lesion sizes, excavated macroscopic-type tumors, ulcer presence, submucosal invasion (SM1 and SM2), poor differentiation, lymphovascular invasion (LVI), perineural invasion, and diffuse and mixed Lauren’s types. Multivariate analysis demonstrated SM1 invasion (odds ration [OR]= 2.285, P = 0.03), SM2 invasion (OR = 3.230, P < 0.001), LVI (OR = 15.702, P < 0.001), mucinous adenocarcinoma (OR = 2.823, P = 0.015), and large lesion size (OR = 1.900, P = 0.006) to be independent risk factors. CONCLUSION The absolute indications for ESD are reasonable, and the feasibility of expanding the indications for ESD requires further investigation. The predictors of LNM include invasion depth, LVI, mucinous adenocarcinoma, and lesion size.