Offshore wind farms are becoming increasingly distant from onshore centralized control centers,and the communication delays between them inevitably introduce time delays in the measurement signal of the primary freque...Offshore wind farms are becoming increasingly distant from onshore centralized control centers,and the communication delays between them inevitably introduce time delays in the measurement signal of the primary frequency control.This causes a deterioration in the performance of the primary frequency control and,in some cases,may even result in frequency instability within the power system.Therefore,a frequency response model that incorporates communication delays was established for power systems that integrate offshore wind power.The Padéapproximation was used to model the time delays,and a linearized frequency response model of the power system was derived to investigate the frequency stability under different time delays.The influences of the wind power proportion and frequency control parameters on the system frequency stability were explored.In addition,a Smith delay compensation control strategy was devised to mitigate the effects of communication delays on the system frequency dynamics.Finally,a power system incorporating offshore wind power was constructed using the MATLAB/Simulink platform.The simulation results demonstrate the effectiveness and robustness of the proposed delay compensation control strategy.展开更多
In recent years,artificial intelligence(AI)has been widely used in the field of electricity,such as load prediction,fault diagnosis of the power equipment,intelligent scheduling of power grids.However,the application ...In recent years,artificial intelligence(AI)has been widely used in the field of electricity,such as load prediction,fault diagnosis of the power equipment,intelligent scheduling of power grids.However,the application of latest AI technology still has many technical difficulties to be solved.In the process of upgrading from the traditional power system to the new-type power system,AC grids,DC grids and micro grids coexist.In addition,there are huge amount of power equipment and electronic devices,and the coupling relationship is very complicated.Moreover,the high proportion of clean energy and flexible loads connected to the grid leads to the enhancement of the stochastic characteristics of the system.And short-term and ultra-short-term forecasts are much more difficult.Therefore,the editorial office of Global Energy Interconnection has planned the special issue of“Artificial Intelligence Applied in New-Type Power System”.展开更多
In an integrated energy system(IES) composed of multiple subsystems, energy coupling causes an energy supply blockage or shutdown in one subsystem, thereby affecting the energy flow distribution optimization of other ...In an integrated energy system(IES) composed of multiple subsystems, energy coupling causes an energy supply blockage or shutdown in one subsystem, thereby affecting the energy flow distribution optimization of other subsystems.The energy supply should be globally optimized during the IES energy supply restoration process to produce the highest restoration net income. Mobile emergency sources can be quickly and flexibly connected to supply energy after an energy outage to ensure a reliable supply to the system, which adds complexity to the decision. This study focuses on a powergas IES with mobile emergency sources and analyzes the coupling relationship between the gas distribution system and the power distribution system in terms of sources, networks, and loads, and the influence of mobile emergency source transportation. The influence of the transient process caused by the restoration operation of the gas distribution system on the power distribution system is also discussed. An optimization model for power-gas IES restoration was established with the objective of maximizing the net income. The coordinated restoration optimization decision-making process was also built to realize the decoupling iteration of the power-gas IES, including system status recognition, mobile emergency source dispatching optimization, gas-to-power gas flow optimization, and parallel intra-partition restoration scheme optimization for both the power and gas distribution systems. A simulation test power-gas IES consisting of an 81-node medium-voltage power distribution network, an 89-node medium-pressure gas distribution network, and four mobile emergency sources was constructed. The simulation analysis verified the efficiency of the proposed coordinated restoration optimization method.展开更多
The high overlap of participants in the carbon emissions trading and electricity markets couples the operations of the two markets.The carbon emission cost(CEC)of coal-fired units becomes part of the power generation ...The high overlap of participants in the carbon emissions trading and electricity markets couples the operations of the two markets.The carbon emission cost(CEC)of coal-fired units becomes part of the power generation cost through market coupling.The accuracy of CEC calculation affects the clearing capacity of coal-fired units in the electric power market.Study of carbon–electricity market interaction and CEC calculations is still in its initial stages.This study analyzes the impact of carbon emissions trading and compliance on the operation of the electric power market and defines the cost transmission mode between the carbon emissions trading and electric power markets.A long-period interactive operation simulation mechanism for the carbon–electricity market is established,and operation and trading models of the carbon emissions trading market and electric power market are established.A daily rolling estimation method for the CEC of coal-fired units is proposed,along with the CEC per unit electric quantity of the coal-fired units.The feasibility and effectiveness of the proposed method are verified through an example simulation,and the factors influencing the CEC are analyzed.展开更多
The doubly fed induction generator(DFIG) is major type of wind turbine generator used in grid-connected wind farms. Practical models of DFIG have been built to study the influence of wind power generation on power sys...The doubly fed induction generator(DFIG) is major type of wind turbine generator used in grid-connected wind farms. Practical models of DFIG have been built to study the influence of wind power generation on power system dynamics. However, most existing practical models of the DFIG are based on rectangular coordinates,in which frequency variation is neglected. In this paper, a phase-amplitude(P-A) model is proposed for a DFIG based on phase and amplitude of the internal voltage. The model structure is much like that of the synchronous generator, and the rotor voltage can manipulate both the amplitude and the phase of the internal voltage.Comparisons have been made between the new P-A model of the DFIG and the synchronous generator model,as well as the asynchronous motor model.The contributions of the new P-A model of the DFIG are discussed and it is demonstrated that the proposed model has better ability in describing power system dynamic phenomena such as voltage dynamics and structural dynamics. Simulation results and a field test validate these contributions.展开更多
A new hierarchical parameter estimation method for doubly fed induction generator (DFIG) and drive train system in a wind turbine generator (WTG) is proposed in this paper. Firstly, the parameters of the DFIG and ...A new hierarchical parameter estimation method for doubly fed induction generator (DFIG) and drive train system in a wind turbine generator (WTG) is proposed in this paper. Firstly, the parameters of the DFIG and the drive train are estimated locally under different types of disturbances. Secondly, a coordination estimation method is further applied to identify the parameters of the DFIG and the drive train simultaneously with the purpose of attaining the global optimal estimation results. The main benefit of the proposed scheme is the improved estimation accuracy. Estimation results confirm the applicability of the proposed estimation technique.展开更多
基金the support of the National Natural Science Foundation of China(52077061)Fundamental Research Funds for the Central Universities(B240201121).
文摘Offshore wind farms are becoming increasingly distant from onshore centralized control centers,and the communication delays between them inevitably introduce time delays in the measurement signal of the primary frequency control.This causes a deterioration in the performance of the primary frequency control and,in some cases,may even result in frequency instability within the power system.Therefore,a frequency response model that incorporates communication delays was established for power systems that integrate offshore wind power.The Padéapproximation was used to model the time delays,and a linearized frequency response model of the power system was derived to investigate the frequency stability under different time delays.The influences of the wind power proportion and frequency control parameters on the system frequency stability were explored.In addition,a Smith delay compensation control strategy was devised to mitigate the effects of communication delays on the system frequency dynamics.Finally,a power system incorporating offshore wind power was constructed using the MATLAB/Simulink platform.The simulation results demonstrate the effectiveness and robustness of the proposed delay compensation control strategy.
文摘In recent years,artificial intelligence(AI)has been widely used in the field of electricity,such as load prediction,fault diagnosis of the power equipment,intelligent scheduling of power grids.However,the application of latest AI technology still has many technical difficulties to be solved.In the process of upgrading from the traditional power system to the new-type power system,AC grids,DC grids and micro grids coexist.In addition,there are huge amount of power equipment and electronic devices,and the coupling relationship is very complicated.Moreover,the high proportion of clean energy and flexible loads connected to the grid leads to the enhancement of the stochastic characteristics of the system.And short-term and ultra-short-term forecasts are much more difficult.Therefore,the editorial office of Global Energy Interconnection has planned the special issue of“Artificial Intelligence Applied in New-Type Power System”.
基金supported by the Open Research Fund of Jiangsu Collaborative Innovation Center for Smart Distribution Network (XTCX202001)National Natural Science Foundation of China (52077061)。
文摘In an integrated energy system(IES) composed of multiple subsystems, energy coupling causes an energy supply blockage or shutdown in one subsystem, thereby affecting the energy flow distribution optimization of other subsystems.The energy supply should be globally optimized during the IES energy supply restoration process to produce the highest restoration net income. Mobile emergency sources can be quickly and flexibly connected to supply energy after an energy outage to ensure a reliable supply to the system, which adds complexity to the decision. This study focuses on a powergas IES with mobile emergency sources and analyzes the coupling relationship between the gas distribution system and the power distribution system in terms of sources, networks, and loads, and the influence of mobile emergency source transportation. The influence of the transient process caused by the restoration operation of the gas distribution system on the power distribution system is also discussed. An optimization model for power-gas IES restoration was established with the objective of maximizing the net income. The coordinated restoration optimization decision-making process was also built to realize the decoupling iteration of the power-gas IES, including system status recognition, mobile emergency source dispatching optimization, gas-to-power gas flow optimization, and parallel intra-partition restoration scheme optimization for both the power and gas distribution systems. A simulation test power-gas IES consisting of an 81-node medium-voltage power distribution network, an 89-node medium-pressure gas distribution network, and four mobile emergency sources was constructed. The simulation analysis verified the efficiency of the proposed coordinated restoration optimization method.
基金supported by Anhui Provincial Natural Science Foundation(No.2208085UD02)National Natural Science Foundation of China(No.52077061).
文摘The high overlap of participants in the carbon emissions trading and electricity markets couples the operations of the two markets.The carbon emission cost(CEC)of coal-fired units becomes part of the power generation cost through market coupling.The accuracy of CEC calculation affects the clearing capacity of coal-fired units in the electric power market.Study of carbon–electricity market interaction and CEC calculations is still in its initial stages.This study analyzes the impact of carbon emissions trading and compliance on the operation of the electric power market and defines the cost transmission mode between the carbon emissions trading and electric power markets.A long-period interactive operation simulation mechanism for the carbon–electricity market is established,and operation and trading models of the carbon emissions trading market and electric power market are established.A daily rolling estimation method for the CEC of coal-fired units is proposed,along with the CEC per unit electric quantity of the coal-fired units.The feasibility and effectiveness of the proposed method are verified through an example simulation,and the factors influencing the CEC are analyzed.
文摘The doubly fed induction generator(DFIG) is major type of wind turbine generator used in grid-connected wind farms. Practical models of DFIG have been built to study the influence of wind power generation on power system dynamics. However, most existing practical models of the DFIG are based on rectangular coordinates,in which frequency variation is neglected. In this paper, a phase-amplitude(P-A) model is proposed for a DFIG based on phase and amplitude of the internal voltage. The model structure is much like that of the synchronous generator, and the rotor voltage can manipulate both the amplitude and the phase of the internal voltage.Comparisons have been made between the new P-A model of the DFIG and the synchronous generator model,as well as the asynchronous motor model.The contributions of the new P-A model of the DFIG are discussed and it is demonstrated that the proposed model has better ability in describing power system dynamic phenomena such as voltage dynamics and structural dynamics. Simulation results and a field test validate these contributions.
基金This research was supported by the National Natural Science Foundation of China (Major Program) (Grant Nos. 51190102 and 51207045).
文摘A new hierarchical parameter estimation method for doubly fed induction generator (DFIG) and drive train system in a wind turbine generator (WTG) is proposed in this paper. Firstly, the parameters of the DFIG and the drive train are estimated locally under different types of disturbances. Secondly, a coordination estimation method is further applied to identify the parameters of the DFIG and the drive train simultaneously with the purpose of attaining the global optimal estimation results. The main benefit of the proposed scheme is the improved estimation accuracy. Estimation results confirm the applicability of the proposed estimation technique.