In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiat...In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiation area is required for the extracted ion beams,which is crucial because it directly affects the experimental precision and therapeutic effect.Specifically,ultra-large-area and high-uniformity scanning are crucial requirements for spacecraft radiation effects assessment and serve as core specification for beamline terminal design.In the 300 MeV proton and heavy ion accelerator complex at the Space Environment Simulation and Research Infrastructure(SESRI),proton and heavy ion beams will be accelerated and ultimately delivered to three irradiation terminals.In order to achieve the required large irradiation area of 320 mm×320 mm,horizontal and vertical scanning magnets are used in the extraction beam line.However,considering the various requirements for beam species and energies,the tracking accuracy of power supplies(PSs),the eddy current effect of scanning magnets,and the fluctuation of ion bunch structure will reduce the irradiation uniformity.To mitigate these effects,a beam uniformity optimization method based on the measured beam distribution was proposed and applied in the accelerator complex at SESRI.In the experiment,the uniformity is successfully optimized from 75%to over 90%after five iterations of adjustment to the PS waveforms.In this paper,the method and experimental results were introduced.展开更多
轻子散射实验是探索核子与原子核结构的理想工具。中国电子离子对撞机(Electron Ion Collider in China,EicC)建议书设想在已开建的强流重离子加速器装置(High Intensity heavy ion Accelerator Facility,HIAF)的基础上,升级质子束流为2...轻子散射实验是探索核子与原子核结构的理想工具。中国电子离子对撞机(Electron Ion Collider in China,EicC)建议书设想在已开建的强流重离子加速器装置(High Intensity heavy ion Accelerator Facility,HIAF)的基础上,升级质子束流为20 GeV的极化束流,并建造2.8~5 GeV极化电子束流,从而实现质心系能量为15~20 GeV的双极化电子-离子对撞。EicC设计的亮度为(2~4)×10^33cm^-2·s^-1,质子束流极化率达到70%,电子束流极化率达到80%。该装置除了能提供极化轻离子束流(例如:氦-3)外,也可产生非极化重离子束流(碳-12~铀-238)。EicC将聚焦核子海夸克部分子结构、原子核物质结构与性质、奇特强子态三个方面的物理研究。高亮度、高精度的对撞机有助于精确地测量核子结构函数并对核子进行三维成像,揭示强相互作用的动力学规律;原子核部分子分布包括核子短程关联以及原子核介质效应同样是该提案的重要科学目标;EicC能区接近重味夸克产生阈值,在研究重味强子谱方面拥有低背景的独特优势,有助于发现研究新的奇特强子态。质子质量起源问题也可以通过重味矢量介子的产生来研究。为了完成上述物理目标,我们将利用最先进的探测器技术建造接近全立体角覆盖的EicC对撞机谱仪。在准备EicC白皮书的过程中,我们得到世界各国专家的支持。EicC的物理与已有的实验和美国即将建设的EIC中的物理项目相互补充。EicC的建成及运行有望引领前沿的中高能核物理研究,使我国在加速器和探测器先进技术等领域实现跨越式发展,为我国核物理与强子物理以及相关科学领域提供大型综合实验平台与人才培养基地。展开更多
随着织机转速提高,共轭凸轮与四连杆组合的平行式打纬机构中的连杆构件会在惯性载荷的作用下变形加大,从而导致钢筘前死心位置与理想位置产生偏差,影响打纬精度。针对该问题采用虚拟仿真与实验结合的方法对机构进行研究,建立了平行打纬...随着织机转速提高,共轭凸轮与四连杆组合的平行式打纬机构中的连杆构件会在惯性载荷的作用下变形加大,从而导致钢筘前死心位置与理想位置产生偏差,影响打纬精度。针对该问题采用虚拟仿真与实验结合的方法对机构进行研究,建立了平行打纬机构柔性连杆下的动力学模型,并运用ADAMS软件进行仿真,探究不同凸轮转速和连杆不同材料对钢筘前死心位置的影响,同时搭建实验平台对仿真结论进行验证。结果表明:凸轮转速对钢筘前死心位置的影响是非线性的,凸轮转速在180 r min以内钢筘的前死心位置稳定且偏差值较小。弹性连杆构件选用比刚度更大的材料有助于减小钢筘前死心位置偏差。研究结果可为高速共轭凸轮平行打纬机构的设计和优化提供参考。展开更多
基金Supported by National Key R&D Program of China(2019YFA0405400)。
文摘In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiation area is required for the extracted ion beams,which is crucial because it directly affects the experimental precision and therapeutic effect.Specifically,ultra-large-area and high-uniformity scanning are crucial requirements for spacecraft radiation effects assessment and serve as core specification for beamline terminal design.In the 300 MeV proton and heavy ion accelerator complex at the Space Environment Simulation and Research Infrastructure(SESRI),proton and heavy ion beams will be accelerated and ultimately delivered to three irradiation terminals.In order to achieve the required large irradiation area of 320 mm×320 mm,horizontal and vertical scanning magnets are used in the extraction beam line.However,considering the various requirements for beam species and energies,the tracking accuracy of power supplies(PSs),the eddy current effect of scanning magnets,and the fluctuation of ion bunch structure will reduce the irradiation uniformity.To mitigate these effects,a beam uniformity optimization method based on the measured beam distribution was proposed and applied in the accelerator complex at SESRI.In the experiment,the uniformity is successfully optimized from 75%to over 90%after five iterations of adjustment to the PS waveforms.In this paper,the method and experimental results were introduced.
文摘轻子散射实验是探索核子与原子核结构的理想工具。中国电子离子对撞机(Electron Ion Collider in China,EicC)建议书设想在已开建的强流重离子加速器装置(High Intensity heavy ion Accelerator Facility,HIAF)的基础上,升级质子束流为20 GeV的极化束流,并建造2.8~5 GeV极化电子束流,从而实现质心系能量为15~20 GeV的双极化电子-离子对撞。EicC设计的亮度为(2~4)×10^33cm^-2·s^-1,质子束流极化率达到70%,电子束流极化率达到80%。该装置除了能提供极化轻离子束流(例如:氦-3)外,也可产生非极化重离子束流(碳-12~铀-238)。EicC将聚焦核子海夸克部分子结构、原子核物质结构与性质、奇特强子态三个方面的物理研究。高亮度、高精度的对撞机有助于精确地测量核子结构函数并对核子进行三维成像,揭示强相互作用的动力学规律;原子核部分子分布包括核子短程关联以及原子核介质效应同样是该提案的重要科学目标;EicC能区接近重味夸克产生阈值,在研究重味强子谱方面拥有低背景的独特优势,有助于发现研究新的奇特强子态。质子质量起源问题也可以通过重味矢量介子的产生来研究。为了完成上述物理目标,我们将利用最先进的探测器技术建造接近全立体角覆盖的EicC对撞机谱仪。在准备EicC白皮书的过程中,我们得到世界各国专家的支持。EicC的物理与已有的实验和美国即将建设的EIC中的物理项目相互补充。EicC的建成及运行有望引领前沿的中高能核物理研究,使我国在加速器和探测器先进技术等领域实现跨越式发展,为我国核物理与强子物理以及相关科学领域提供大型综合实验平台与人才培养基地。
文摘随着织机转速提高,共轭凸轮与四连杆组合的平行式打纬机构中的连杆构件会在惯性载荷的作用下变形加大,从而导致钢筘前死心位置与理想位置产生偏差,影响打纬精度。针对该问题采用虚拟仿真与实验结合的方法对机构进行研究,建立了平行打纬机构柔性连杆下的动力学模型,并运用ADAMS软件进行仿真,探究不同凸轮转速和连杆不同材料对钢筘前死心位置的影响,同时搭建实验平台对仿真结论进行验证。结果表明:凸轮转速对钢筘前死心位置的影响是非线性的,凸轮转速在180 r min以内钢筘的前死心位置稳定且偏差值较小。弹性连杆构件选用比刚度更大的材料有助于减小钢筘前死心位置偏差。研究结果可为高速共轭凸轮平行打纬机构的设计和优化提供参考。