OBJECTIVE To assess the feasibility and safety of the minimalistic approach to left atrial appendage occlusion(LAAO) guided by cardiac computed tomography angiography(CCTA).METHODS Ninety consecutive patients who unde...OBJECTIVE To assess the feasibility and safety of the minimalistic approach to left atrial appendage occlusion(LAAO) guided by cardiac computed tomography angiography(CCTA).METHODS Ninety consecutive patients who underwent LAAO, with or without CCTA-guided, were matched(1:2). Each step of the LAAO procedure in the computed tomography(CT) guidance group(CT group) was directed by preprocedural CT planning. In the control group, LAAO was performed using the standard method. All patients were followed up for 12 months, and device surveillance was conducted using CCTA.RESULTS A total of 90 patients were included in the analysis, with 30 patients in the CT group and 60 matched patients in the control group. All patients were successfully implanted with Watchman devices. The mean ages for the CT group and the control group were 70.0 ± 9.4 years and 68.4 ± 11.9 years(P = 0.52), respectively. The procedure duration(45.6 ± 10.7 min vs. 58.8 ± 13.0 min,P < 0.001) and hospital stay(7.5 ± 2.4 day vs. 9.6 ± 2.8 day, P = 0.001) in the CT group was significantly shorter compared to the control group. However, the total radiation dose was higher in the CT group compared to the control group(904.9 ± 348.0 m Gy vs.711.9 ± 211.2 m Gy, P = 0.002). There were no significant differences in periprocedural pericardial effusion(3.3% vs. 6.3%, P = 0.8) between the two groups. The rate of postprocedural adverse events(13.3% vs. 18.3%, P = 0.55) were comparable between both groups at 12 months follow-up.CONCLUSIONS CCTA is capable of detailed LAAO procedure planning. Minimalistic LAAO with preprocedural CCTA planning was feasible and safe, with shortened procedure time and acceptable increased radiation and contras consumption. For patients with contraindications to general anesthesia and/or transesophageal echocardiography, this promising method may be an alternative to conventional LAAO.展开更多
The real-time retrieval of submicron aerosol size distributions is of major interest for applications. Based on the Mie theory,the spectral extinction method offers a simple measurement principle and a convenient opti...The real-time retrieval of submicron aerosol size distributions is of major interest for applications. Based on the Mie theory,the spectral extinction method offers a simple measurement principle and a convenient optical arrangement. In contrast to the relative simplicity of the experimental measurement the retrieval of the particles size distribution and particle concentration from the spectral extinction method is difficult. Mie scattering Equation is a Fredholm Integral Equation of the First Kind. This paper develops a hybrid iterative model-dependent algorithm for on-line particle sizing from extinction spectra which is both computationally efficient and accurate. Applying the refined Mie diagnostic iterative procedures within some candidate solutions can identify the unique result accurately and rapidly enough for real time measurement. With the addition of added Gaussian noise,an average tolerance up to 5% of noise level is kept for particle size from submicron to micrometer under moderate polydispersity.展开更多
基金supported by the Logistics Support Ministry of China (No.22BJZ41)the Capital's Funds for Health Improvement and Research (No.CFH2024-2-5071)。
文摘OBJECTIVE To assess the feasibility and safety of the minimalistic approach to left atrial appendage occlusion(LAAO) guided by cardiac computed tomography angiography(CCTA).METHODS Ninety consecutive patients who underwent LAAO, with or without CCTA-guided, were matched(1:2). Each step of the LAAO procedure in the computed tomography(CT) guidance group(CT group) was directed by preprocedural CT planning. In the control group, LAAO was performed using the standard method. All patients were followed up for 12 months, and device surveillance was conducted using CCTA.RESULTS A total of 90 patients were included in the analysis, with 30 patients in the CT group and 60 matched patients in the control group. All patients were successfully implanted with Watchman devices. The mean ages for the CT group and the control group were 70.0 ± 9.4 years and 68.4 ± 11.9 years(P = 0.52), respectively. The procedure duration(45.6 ± 10.7 min vs. 58.8 ± 13.0 min,P < 0.001) and hospital stay(7.5 ± 2.4 day vs. 9.6 ± 2.8 day, P = 0.001) in the CT group was significantly shorter compared to the control group. However, the total radiation dose was higher in the CT group compared to the control group(904.9 ± 348.0 m Gy vs.711.9 ± 211.2 m Gy, P = 0.002). There were no significant differences in periprocedural pericardial effusion(3.3% vs. 6.3%, P = 0.8) between the two groups. The rate of postprocedural adverse events(13.3% vs. 18.3%, P = 0.55) were comparable between both groups at 12 months follow-up.CONCLUSIONS CCTA is capable of detailed LAAO procedure planning. Minimalistic LAAO with preprocedural CCTA planning was feasible and safe, with shortened procedure time and acceptable increased radiation and contras consumption. For patients with contraindications to general anesthesia and/or transesophageal echocardiography, this promising method may be an alternative to conventional LAAO.
文摘The real-time retrieval of submicron aerosol size distributions is of major interest for applications. Based on the Mie theory,the spectral extinction method offers a simple measurement principle and a convenient optical arrangement. In contrast to the relative simplicity of the experimental measurement the retrieval of the particles size distribution and particle concentration from the spectral extinction method is difficult. Mie scattering Equation is a Fredholm Integral Equation of the First Kind. This paper develops a hybrid iterative model-dependent algorithm for on-line particle sizing from extinction spectra which is both computationally efficient and accurate. Applying the refined Mie diagnostic iterative procedures within some candidate solutions can identify the unique result accurately and rapidly enough for real time measurement. With the addition of added Gaussian noise,an average tolerance up to 5% of noise level is kept for particle size from submicron to micrometer under moderate polydispersity.