期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Harmonic State-Space Based AC-Side Impedance Model of MMC and High Frequency Oscillation Characteristics Analysis
1
作者 Hui Fang Jingsen Zhou +3 位作者 Haozheng wang yanxu wang Hongji Xiang Yechun Xin 《Energy Engineering》 EI 2023年第4期831-849,共19页
Recently,high-frequency oscillation of themodularmultilevel converter(MMC)based high-voltage direct current(HVDC)projects has attracted great attentions.In order to analyze the small-signal stability,this paper uses t... Recently,high-frequency oscillation of themodularmultilevel converter(MMC)based high-voltage direct current(HVDC)projects has attracted great attentions.In order to analyze the small-signal stability,this paper uses the harmonic state-space(HSS)method to establish a detailed frequency domain impedance model of the AC-side of the HVDC transmission system,which considers the internal dynamic characteristics.In addition,the suggested model is also used to assess the system’s high-frequency oscillationmechanism,and the effects of the MMC current inner loop control,feedforward voltage links,and control delay on the high-frequency impedance characteristics and the effect of higher harmonic components.Finally,three oscillation suppression schemes are analyzed for the oscillation problems occurring in actual engineering,and a simplified impedance model considering only the highfrequency impedance characteristics is established to compare the suppression effect with the detailed impedance model to prove its reliability. 展开更多
关键词 Modular multilevel converter impedance modeling small-signal stability suppression strategy
下载PDF
Analysis of Additional Damping Control Strategy and Parameter Optimization for Improving Small Signal Stability of VSC-HVDC System
2
作者 Hui Fang Jingsen Zhou +3 位作者 Hanjie Liu yanxu wang Hongji Xiang Yechun Xin 《Energy Engineering》 EI 2023年第4期931-948,共18页
The voltage source converter based high voltage direct current(VSC-HVDC)system is based on voltage source converter,and its control system is more complex.Also affected by the fast control of power electronics,oscilla... The voltage source converter based high voltage direct current(VSC-HVDC)system is based on voltage source converter,and its control system is more complex.Also affected by the fast control of power electronics,oscillation phenomenon in wide frequency domain may occur.To address the problem of small signal stability of the VSCHVDC system,a converter control strategy is designed to improve its small signal stability,and the risk of system oscillation is reduced by attaching a damping controller and optimizing the control parameters.Based on the modeling of the VSC-HVDC system,the general architecture of the inner and outer loop control of the VSCHVDC converter is established;and the damping controllers for DC control and AC control are designed in the phase-locked loop and the inner and outer loop control parts respectively;the state-space statemodel of the control system is established to analyze its performance.And the electromagnetic transient simulation model is built on the PSCAD/EMTDC simulation platform to verify the accuracy of the small signal model.The influence of the parameters of each control part on the stability of the system is summarized.The main control parts affecting stability are optimized for the phenomenon of oscillation due to changes in operation mode occurring on the AC side due to faults and other reasons,which effectively eliminates system oscillation and improves system small signal stability,providing a certain reference for engineering design. 展开更多
关键词 VSC-HVDC system small signal modeling eigenvalue analysis parameter optimization
下载PDF
计算流体力学研究B型主动脉夹层中4D Flow MRI的应用进展
3
作者 王彦旭 何益港 秦永林 《中华介入放射学电子杂志》 2023年第2期159-163,共5页
主动脉夹层是危及生命的心血管急症之一,其复杂的血流动力学特征对疾病发生和发展具有重要意义。计算流体力学方法问世后,许多学者已将其用于分析人体血管血流动力学。现有基于计算流体力学(computational fluid dynamics,CFD)的B型主... 主动脉夹层是危及生命的心血管急症之一,其复杂的血流动力学特征对疾病发生和发展具有重要意义。计算流体力学方法问世后,许多学者已将其用于分析人体血管血流动力学。现有基于计算流体力学(computational fluid dynamics,CFD)的B型主动脉夹层(type B aortic dissection,TBAD)血流动力学研究不足在于,计算结果的准确性和临床意义的解释有待提高。四维流动磁共振(4D Flow MRI)与CFD相结合为解决这些问题提供了新思路。文章就CFD研究TBAD中4D Flow MRI应用进展做一综述。 展开更多
关键词 B型主动脉夹层 血流动力学 计算流体力学 4D Flow MRI
原文传递
Combined Wind-Storage Frequency Modulation Control Strategy Based on Fuzzy Prediction and Dynamic Control
4
作者 Weiru wang Yulong Cao +3 位作者 yanxu wang Jiale You Guangnan Zhang Yu Xiao 《Energy Engineering》 EI 2024年第12期3801-3823,共23页
To ensure frequency stability in power systems with high wind penetration,the doubly-fed induction generator(DFIG)is often used with the frequency fast response control(FFRC)to participate in frequency response.Howeve... To ensure frequency stability in power systems with high wind penetration,the doubly-fed induction generator(DFIG)is often used with the frequency fast response control(FFRC)to participate in frequency response.However,a certain output power suppression amount(OPSA)is generated during frequency support,resulting in the frequency modulation(FM)capability of DFIG not being fully utilised,and the system’s unbalanced power will be increased during speed recovery,resulting in a second frequency drop(SFD)in the system.Firstly,the frequency response characteristics of the power system with DFIG containing FFRC are analysed.Then,based on the analysis of the generation mechanism of OPSA and SFD,a combined wind-storage FM control strategy is proposed to improve the system’s frequency response characteristics.This strategy reduces the effect of OPSA and improves the FM capability of DFIG by designing the fuzzy logic of the coefficients of FFRC according to the system frequency index in the frequency support stage.During the speed recovery stage,the energy storage(ES)active power reference value is calculated according to the change of DFIG rotor speed,and the ES output power is dynamically adjusted to reduce the SFD.Finally,taking the IEEE 39-bus test system as an example,real-time digital simulation verification was conducted based on the RTLAB OP5707 simulation platform.The simulation results showthat theproposedmethodcan improve theFMcapabilityofDFIG,reduce the SFDunder thepremise of guaranteeing the rapid rotor speed recovery,and avoid the overshooting phenomenon so that the systemfrequency can be quickly restored to a stable state. 展开更多
关键词 Doubly-fed induction generator frequency fast response control output power suppression amount frequency response characteristics second frequency drop combined wind-storage
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部