Background:To evaluate the precision of corneal higher-order aberrations measurements after small incision lenticule extraction(SMILE)using the Sirius Scheimpfug-Placido topographer(CSO,Italy).Methods:Seventy-fve eyes...Background:To evaluate the precision of corneal higher-order aberrations measurements after small incision lenticule extraction(SMILE)using the Sirius Scheimpfug-Placido topographer(CSO,Italy).Methods:Seventy-fve eyes from 75 postoperative subjects were included in this prospective study.Three consecutive corneal aberrometric measurements were obtained with the Scheimpfug-Placido topographer by two experienced operators to assess intra-and inter-observer reproducibility.The within-subject standard deviation(Sw),test-retest repeatability(TRT)and the intraclass correlation coefcient(ICC)were calculated.Results:For intraobserver repeatability of anterior and total corneal aberrations,all ICCs were more than 0.922,except for trefoil(0.722 to 0.768).The ICCs of total root mean square(RMS),coma Z(3,±1),and spherical aberration Z(4,0)were over 0.810 while higher-order RMS,trefoil Z(3,±3),and astigmatism II Z(4,±2)were below 0.634 for posterior corneal surface aberrations.All Sw values for all types of aberrations were equal to or below 0.07μm.Regarding interobserver reproducibility,all TRT values were no more than 0.12μm,0.05μm,and 0.11μm for anterior,posterior,and total corneal aberrations,respectively.The ICC values ranged from 0.875 to 0.989,from 0.686 to 0.976 and over 0.834 for anterior,posterior,and total corneal aberrations,respectively.Conclusions:The repeatability of measurements of anterior and total corneal aberrations with the Sirius system in corneas after SMILE surgery was high,except for trefoil.There was some variability in posterior corneal aberrometric measurements.High reproducibility of corneal aberrometric measurements was observed between measurements of both examiners,except for trefoil,with poor to moderate reproducibility.展开更多
Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound ...Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound pachymetry(USP).Methods:A systematic literature search was conducted for relevant studies published on PubMed,Medline,EMBASE,and the Cochrane Library and ClinicalTrials.gov from inception to August 1st,2019.Primary outcome measures were CCT measurements between Sirius and USP.A random effects model was used to pool CCT measurements.Results:A total of twelve studies involving 862 eyes were included in this meta-analysis.The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different(P<0.0001).The mean difference between Sirius and USP was-11.26μm with a 95%confidence interval(CI)(-16.92μm,-5.60μm).The heterogeneity Was IP=60%(P=0.004).Conclusion:CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP.However,it may be argued that the mean difference of 11.26μm is not a clinically significant difference.展开更多
Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound ...Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound pachymetry(USP).Methods:A systematic literature search was conducted for relevant studies published on PubMed,Medline,EMBASE,and the Cochrane Library and ClinicalTrials.gov from inception to August 1st,2019.Primary outcome measures were CCT measurements between Sirius and USP.A random effects model was used to pool CCT measurements.Results:A total of twelve studies involving 862 eyes were included in this meta-analysis.The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different(P<0.0001).The mean difference between Sirius and USP was−11.26μm with a 95%confidence interval(CI)(−16.92μm,−5.60μm).The heterogeneity was I^(2)=60%(P=0.004).Conclusion:CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP.However,it may be argued that the mean difference of 11.26μm is not a clinically significant difference.展开更多
Purpose:To assess the repeatability and reproducibility of swept-source optical coherence tomography(SS-OCT)and Scheimpflug system and evaluate the agreement between the two systems in measuring multiple corneal regio...Purpose:To assess the repeatability and reproducibility of swept-source optical coherence tomography(SS-OCT)and Scheimpflug system and evaluate the agreement between the two systems in measuring multiple corneal regions in children.Methods:Pachymetric and keratometric maps for both systems were evaluated.Central,midperipheral and peripheral corneal thickness(CT),keratometry and astigmatism power vectors were recorded.The three outcomes yielded by the same observer were used to assess intraobserver repeatability.The differences in the mean values provided by each observer were used to evaluate interobserver reproducibility.Within-subject standard deviation,test-retest repeatability(TRT)and coefficient of variation(CoV)were used to analyze the intraobserver repeatability and interobserver reproducibility.Paired T-test and Bland-Altman were used to appraise interdevice agreement.Results:Seventy-eight eyes of 78 children were included.The CoV was≤2.12 and 1.10%,respectively,for repeatability and reproducibility.TRT and CoV were lower for central and paracentral CT measurements than for peripheral measurements.The SS-OCT device generated higher precision when acquiring CT data,whereas Scheimpflug system showed higher reliability when measuring corneal keratometry.Although the CT readings measured using SS-OCT were significantly thinner than Scheimpflug device(P<0.001),the central and thinnest CT values were still of high agreement.The interdevice agreement of keratometry measurement was high for the central corneal region and moderate for the paracentral and peripheral areas.Conclusions:The precision of CT measurements by SS-OCT was higher,while the reliability of keratometry measurements by the Scheimpflug system was higher in children.Apart from the measured values in the central corneal region,the thickness and keratometry readings should not be considered interchangeable between the two systems.展开更多
Purpose:To assess the repeatability and reproducibility of swept-source optical coherence tomography(SS-OCT)and Scheimpflug system and evaluate the agreement between the two systems in measuring multiple corneal regio...Purpose:To assess the repeatability and reproducibility of swept-source optical coherence tomography(SS-OCT)and Scheimpflug system and evaluate the agreement between the two systems in measuring multiple corneal regions in children.Methods:Pachymetric and keratometric maps for both systems were evaluated.Central,midperipheral and peripheral corneal thickness(CT),keratometry and astigmatism power vectors were recorded.The three outcomes yielded by the same observer were used to assess intraobserver repeatability.The differences in the mean values provided by each observer were used to evaluate interobserver reproducibility.Within-subject standard deviation,test-retest repeatability(TRT)and coefficient of variation(CoV)were used to analyze the intraobserver repeatability and interobserver reproducibility.Paired T-test and Bland-Altman were used to appraise interdevice agreement.Results:Seventy-eight eyes of 78 children were included.The CoV was≤2.12 and 1.10%,respectively,for repeatability and reproducibility.TRT and CoV were lower for central and paracentral CT measurements than for peripheral measurements.The SS-OCT device generated higher precision when acquiring CT data,whereas Scheimpflug system showed higher reliability when measuring corneal keratometry.Although the CT readings measured using SS-OCT were significantly thinner than Scheimpflug device(P<0.001),the central and thinnest CT values were still of high agreement.The interdevice agreement of keratometry measurement was high for the central corneal region and moderate for the paracentral and peripheral areas.Conclusions:The precision of CT measurements by SS-OCT was higher,while the reliability of keratometry measurements by the Scheimpflug system was higher in children.Apart from the measured values in the central corneal region,the thickness and keratometry readings should not be considered interchangeable between the two systems.展开更多
基金the Medical and Health Science and Technology Program of Zhejiang Province(2019KY111)Foundation of Wenzhou City Science&Technology Bureau(Y2020037)+1 种基金EYE&ENT Hospital of Fudan University High-level Talents Program(2021318)Clinical Research Plan of SHDC(SHDC2020CR1043B)。
文摘Background:To evaluate the precision of corneal higher-order aberrations measurements after small incision lenticule extraction(SMILE)using the Sirius Scheimpfug-Placido topographer(CSO,Italy).Methods:Seventy-fve eyes from 75 postoperative subjects were included in this prospective study.Three consecutive corneal aberrometric measurements were obtained with the Scheimpfug-Placido topographer by two experienced operators to assess intra-and inter-observer reproducibility.The within-subject standard deviation(Sw),test-retest repeatability(TRT)and the intraclass correlation coefcient(ICC)were calculated.Results:For intraobserver repeatability of anterior and total corneal aberrations,all ICCs were more than 0.922,except for trefoil(0.722 to 0.768).The ICCs of total root mean square(RMS),coma Z(3,±1),and spherical aberration Z(4,0)were over 0.810 while higher-order RMS,trefoil Z(3,±3),and astigmatism II Z(4,±2)were below 0.634 for posterior corneal surface aberrations.All Sw values for all types of aberrations were equal to or below 0.07μm.Regarding interobserver reproducibility,all TRT values were no more than 0.12μm,0.05μm,and 0.11μm for anterior,posterior,and total corneal aberrations,respectively.The ICC values ranged from 0.875 to 0.989,from 0.686 to 0.976 and over 0.834 for anterior,posterior,and total corneal aberrations,respectively.Conclusions:The repeatability of measurements of anterior and total corneal aberrations with the Sirius system in corneas after SMILE surgery was high,except for trefoil.There was some variability in posterior corneal aberrometric measurements.High reproducibility of corneal aberrometric measurements was observed between measurements of both examiners,except for trefoil,with poor to moderate reproducibility.
基金supported in part by the Foundation of Wenzhou City Science&Technology Bureau(Grant No.Y2020037)Medical and Health Science and Technology Program of Zhejiang Province(Grant No.2019KY111)+1 种基金Zhejiang Provincial&Ministry of Health Research Fund for Medical Sciences(Grant No.WKJ-ZJ-2134)Zhejiang Provincial High-level Talents Program(Grant No.2017-102).
文摘Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound pachymetry(USP).Methods:A systematic literature search was conducted for relevant studies published on PubMed,Medline,EMBASE,and the Cochrane Library and ClinicalTrials.gov from inception to August 1st,2019.Primary outcome measures were CCT measurements between Sirius and USP.A random effects model was used to pool CCT measurements.Results:A total of twelve studies involving 862 eyes were included in this meta-analysis.The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different(P<0.0001).The mean difference between Sirius and USP was-11.26μm with a 95%confidence interval(CI)(-16.92μm,-5.60μm).The heterogeneity Was IP=60%(P=0.004).Conclusion:CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP.However,it may be argued that the mean difference of 11.26μm is not a clinically significant difference.
基金supported in part by the Foundation of Wenzhou City Science&Technology Bureau(Y2020037)Medical and Health Science and Technology Program of Zhejiang Province(2019KY111)+1 种基金Zhejiang Provincial&Ministry of Health Research Fund for Medical Sciences(WKJ-ZJ-2134)Zhejiang Provincial High-level Talents Program(2017–102).
文摘Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound pachymetry(USP).Methods:A systematic literature search was conducted for relevant studies published on PubMed,Medline,EMBASE,and the Cochrane Library and ClinicalTrials.gov from inception to August 1st,2019.Primary outcome measures were CCT measurements between Sirius and USP.A random effects model was used to pool CCT measurements.Results:A total of twelve studies involving 862 eyes were included in this meta-analysis.The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different(P<0.0001).The mean difference between Sirius and USP was−11.26μm with a 95%confidence interval(CI)(−16.92μm,−5.60μm).The heterogeneity was I^(2)=60%(P=0.004).Conclusion:CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP.However,it may be argued that the mean difference of 11.26μm is not a clinically significant difference.
基金This work was supported in part by the Medical and Health Science and Technology Program of Zhejiang Province(2019KY111)Foundation of Wenzhou City Science&Technology Bureau(Y20180174)+3 种基金Zhejiang Provincial Key Research and Development Program(2018C03012)Zhejiang Provincial High-level Talents Program(2017–102)Wenzhou Key Team of Scientific and Technological Innovation(C20170002)The contribution from the G.B.Bietti Foundation was supported by the Italian Ministry of Health and Fondazione Roma.
文摘Purpose:To assess the repeatability and reproducibility of swept-source optical coherence tomography(SS-OCT)and Scheimpflug system and evaluate the agreement between the two systems in measuring multiple corneal regions in children.Methods:Pachymetric and keratometric maps for both systems were evaluated.Central,midperipheral and peripheral corneal thickness(CT),keratometry and astigmatism power vectors were recorded.The three outcomes yielded by the same observer were used to assess intraobserver repeatability.The differences in the mean values provided by each observer were used to evaluate interobserver reproducibility.Within-subject standard deviation,test-retest repeatability(TRT)and coefficient of variation(CoV)were used to analyze the intraobserver repeatability and interobserver reproducibility.Paired T-test and Bland-Altman were used to appraise interdevice agreement.Results:Seventy-eight eyes of 78 children were included.The CoV was≤2.12 and 1.10%,respectively,for repeatability and reproducibility.TRT and CoV were lower for central and paracentral CT measurements than for peripheral measurements.The SS-OCT device generated higher precision when acquiring CT data,whereas Scheimpflug system showed higher reliability when measuring corneal keratometry.Although the CT readings measured using SS-OCT were significantly thinner than Scheimpflug device(P<0.001),the central and thinnest CT values were still of high agreement.The interdevice agreement of keratometry measurement was high for the central corneal region and moderate for the paracentral and peripheral areas.Conclusions:The precision of CT measurements by SS-OCT was higher,while the reliability of keratometry measurements by the Scheimpflug system was higher in children.Apart from the measured values in the central corneal region,the thickness and keratometry readings should not be considered interchangeable between the two systems.
基金supported in part by the Medical and Health Science and Technology Program of Zhejiang Province(2019kY111)Foundation of Wenzhou City Science&Technology Bureau(Y20180174)+2 种基金Zhejiang Provincial Key Researchand Development Program(2018C03012)Zhejiang Provincial High-level Talents Program(2017-102)WenzhouKey Teamof Scientific and Technological Innovation(C20170002).
文摘Purpose:To assess the repeatability and reproducibility of swept-source optical coherence tomography(SS-OCT)and Scheimpflug system and evaluate the agreement between the two systems in measuring multiple corneal regions in children.Methods:Pachymetric and keratometric maps for both systems were evaluated.Central,midperipheral and peripheral corneal thickness(CT),keratometry and astigmatism power vectors were recorded.The three outcomes yielded by the same observer were used to assess intraobserver repeatability.The differences in the mean values provided by each observer were used to evaluate interobserver reproducibility.Within-subject standard deviation,test-retest repeatability(TRT)and coefficient of variation(CoV)were used to analyze the intraobserver repeatability and interobserver reproducibility.Paired T-test and Bland-Altman were used to appraise interdevice agreement.Results:Seventy-eight eyes of 78 children were included.The CoV was≤2.12 and 1.10%,respectively,for repeatability and reproducibility.TRT and CoV were lower for central and paracentral CT measurements than for peripheral measurements.The SS-OCT device generated higher precision when acquiring CT data,whereas Scheimpflug system showed higher reliability when measuring corneal keratometry.Although the CT readings measured using SS-OCT were significantly thinner than Scheimpflug device(P<0.001),the central and thinnest CT values were still of high agreement.The interdevice agreement of keratometry measurement was high for the central corneal region and moderate for the paracentral and peripheral areas.Conclusions:The precision of CT measurements by SS-OCT was higher,while the reliability of keratometry measurements by the Scheimpflug system was higher in children.Apart from the measured values in the central corneal region,the thickness and keratometry readings should not be considered interchangeable between the two systems.