BACKGROUND Most endoscopic anti-reflux interventions for gastroesophageal reflux disease(GERD)management are technically challenging to practice with inadequate data to support it utility.Therefore,this study was carr...BACKGROUND Most endoscopic anti-reflux interventions for gastroesophageal reflux disease(GERD)management are technically challenging to practice with inadequate data to support it utility.Therefore,this study was carried to evaluate the effectiveness and safety newer endoscopic full-thickness fundoplication(EFTP)device along with Argon Plasma Coagulation to treat individuals with GERD.AIM To evaluate the effectiveness and safety newer EFTP device along with Argon Plasma Coagulation to treat individuals with GERD.METHODS This study was a single-center comparative analysis conducted on patients treated at a Noble Institute of Gastroenterology,Ahmedabad,hospital between 2020 and 2022.The research aimed to retrospectively analyze patient data on GERD symptoms and proton pump inhibitor(PPI)dependence who underwent EFTP using the GERD-X system along with argon plasma coagulation(APC).The primary endpoint was the mean change in the total gastroesophageal reflux disease health-related quality of life(GERD-HRQL)score compared to the baseline measurement at the 3-month follow-up.Secondary endpoints encompassed enhancements in the overall GERD-HRQL score,improvements in GERD symptom scores at the 3 and changes in PPI usage at the 3 and 12-month time points.RESULTS In this study,patients most were in Hill Class II,and over half had ineffective esophageal motility.Following the EFTP procedure,there were significant improvements in heartburn and regurgitation scores,as well as GERDHRQL scores(P<0.001).PPI use significantly decreased,with 82.6%not needing PPIs or prokinetics at end of 1 year.No significant adverse events related to the procedures were observed in either group.CONCLUSION The EFTP along with APC procedure shows promise in addressing GERD symptoms and improving patients'quality of life,particularly for suitable candidates.Moreover,the application of a lone clip with APC yielded superior outcomes and exhibited greater cost-effectiveness.展开更多
AIM: To assess the usefulness of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) for lymph node metastasis in pancreatobiliary carcinoma.METHODS: All patients suspected of pancreatobiliary carcinoma wit...AIM: To assess the usefulness of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) for lymph node metastasis in pancreatobiliary carcinoma.METHODS: All patients suspected of pancreatobiliary carcinoma with visible lymph nodes after standard EUS between June, 2009 and January, 2012 were enrolled. In the primary analysis, patients with successful EUS-fine needle aspiration (FNA) were included. The lymph nodes were assessed by several standard EUS variables (short and long axis lengths, shape, edge characteristic and echogenicity), color Doppler EUS variable [central intranodal blood vessel (CIV) presence] and CH-EUS variable (heterogeneous/homogeneous enhancement patterns). The diagnostic accuracy relative to EUS-FNA was calculated. In the second analysis, N-stage diagnostic accuracy of CH-EUS was compared with EUS-FNA in patients who underwent surgical resection.RESULTS: One hundred and nine patients (143 lymph nodes) fulfilled the criteria. The short axis cut-off ≥ 13 mm predicted malignancy with a sensitivity and specificity of 72% and 85%, respectively. These values were 72% and 63% for the long axis cut-off ≥ 20 mm, 62% and 75% for the round shape variable, 81% and 30% for the sharp edge variable, 66% and 61% for the hypoechogenicity variable, 70% and 72% for the CIV-absent variable, and 83% and 91% for the heterogeneous CH-EUS-enhancement variable, respectively. CH-EUS was more accurate than standard and color Doppler EUS, except the short axis cut-off. Notably, three patients excluded because of EUS-FNA failure were correctly N-staged by CH-EUS.CONCLUSION: CH-EUS complements standard and color Doppler EUS and EUS-FNA for assessment of lymph node metastases.展开更多
AIM: To assess anti-migration potential of six biliary covered self-expandable metal stents(C-SEMSs) by using a newly designed phantom model. METHODS: In the phantom model, the stent was placed in differently sized ho...AIM: To assess anti-migration potential of six biliary covered self-expandable metal stents(C-SEMSs) by using a newly designed phantom model. METHODS: In the phantom model, the stent was placed in differently sized holes in a silicone wall and retracted with a retraction robot. Resistance force to migration(RFM) was measured by a force gauge on the stent end. Radial force(RF) was measured with a RF measurement machine. Measured flare structure variables were the outer diameter, height, and taper angle of the flare(ODF, HF, and TAF, respectively). Correlations between RFM and RF or flare variables were analyzed using a linear correlated model.RESULTS: Out of the six stents, five stents were braided, the other was laser-cut. The RF and RFM of each stent were expressed as the average of five replicate measurements. For all six stents, RFM and RF decreased as the hole diameter increased. For all six stents, RFM and RF correlated strongly when the stent had not fully expanded. This correlation was not observed in the five braided stents excluding the laser cut stent. For all six stents, there was a strong correlation between RFM and TAF when the stent fully expanded. For the five braided stents, RFM after full stent expansion correlated strongly with all three stent flare structure variables(ODF, HF, and TAF). The laser-cut C-SEMS had higher RFMs than the braided C-SEMSs regardless of expansion state.CONCLUSION: RF was an important anti-migration property when the C-SEMS did not fully expand. Once fully expanded, stent flare structure variables plays an important role in anti-migration.展开更多
文摘BACKGROUND Most endoscopic anti-reflux interventions for gastroesophageal reflux disease(GERD)management are technically challenging to practice with inadequate data to support it utility.Therefore,this study was carried to evaluate the effectiveness and safety newer endoscopic full-thickness fundoplication(EFTP)device along with Argon Plasma Coagulation to treat individuals with GERD.AIM To evaluate the effectiveness and safety newer EFTP device along with Argon Plasma Coagulation to treat individuals with GERD.METHODS This study was a single-center comparative analysis conducted on patients treated at a Noble Institute of Gastroenterology,Ahmedabad,hospital between 2020 and 2022.The research aimed to retrospectively analyze patient data on GERD symptoms and proton pump inhibitor(PPI)dependence who underwent EFTP using the GERD-X system along with argon plasma coagulation(APC).The primary endpoint was the mean change in the total gastroesophageal reflux disease health-related quality of life(GERD-HRQL)score compared to the baseline measurement at the 3-month follow-up.Secondary endpoints encompassed enhancements in the overall GERD-HRQL score,improvements in GERD symptom scores at the 3 and changes in PPI usage at the 3 and 12-month time points.RESULTS In this study,patients most were in Hill Class II,and over half had ineffective esophageal motility.Following the EFTP procedure,there were significant improvements in heartburn and regurgitation scores,as well as GERDHRQL scores(P<0.001).PPI use significantly decreased,with 82.6%not needing PPIs or prokinetics at end of 1 year.No significant adverse events related to the procedures were observed in either group.CONCLUSION The EFTP along with APC procedure shows promise in addressing GERD symptoms and improving patients'quality of life,particularly for suitable candidates.Moreover,the application of a lone clip with APC yielded superior outcomes and exhibited greater cost-effectiveness.
基金Supported by Grants from the Japan Society for the Promotion of Science and the Japanese Foundation for the Research and Promotion of Endoscopy,No.22590764 and No.25461035
文摘AIM: To assess the usefulness of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) for lymph node metastasis in pancreatobiliary carcinoma.METHODS: All patients suspected of pancreatobiliary carcinoma with visible lymph nodes after standard EUS between June, 2009 and January, 2012 were enrolled. In the primary analysis, patients with successful EUS-fine needle aspiration (FNA) were included. The lymph nodes were assessed by several standard EUS variables (short and long axis lengths, shape, edge characteristic and echogenicity), color Doppler EUS variable [central intranodal blood vessel (CIV) presence] and CH-EUS variable (heterogeneous/homogeneous enhancement patterns). The diagnostic accuracy relative to EUS-FNA was calculated. In the second analysis, N-stage diagnostic accuracy of CH-EUS was compared with EUS-FNA in patients who underwent surgical resection.RESULTS: One hundred and nine patients (143 lymph nodes) fulfilled the criteria. The short axis cut-off ≥ 13 mm predicted malignancy with a sensitivity and specificity of 72% and 85%, respectively. These values were 72% and 63% for the long axis cut-off ≥ 20 mm, 62% and 75% for the round shape variable, 81% and 30% for the sharp edge variable, 66% and 61% for the hypoechogenicity variable, 70% and 72% for the CIV-absent variable, and 83% and 91% for the heterogeneous CH-EUS-enhancement variable, respectively. CH-EUS was more accurate than standard and color Doppler EUS, except the short axis cut-off. Notably, three patients excluded because of EUS-FNA failure were correctly N-staged by CH-EUS.CONCLUSION: CH-EUS complements standard and color Doppler EUS and EUS-FNA for assessment of lymph node metastases.
基金Supported by Japan Society for the Promotion of Science and the Japanese Foundation for the Research and Promotion of Endoscopy,No.22590764 and No.25461035
文摘AIM: To assess anti-migration potential of six biliary covered self-expandable metal stents(C-SEMSs) by using a newly designed phantom model. METHODS: In the phantom model, the stent was placed in differently sized holes in a silicone wall and retracted with a retraction robot. Resistance force to migration(RFM) was measured by a force gauge on the stent end. Radial force(RF) was measured with a RF measurement machine. Measured flare structure variables were the outer diameter, height, and taper angle of the flare(ODF, HF, and TAF, respectively). Correlations between RFM and RF or flare variables were analyzed using a linear correlated model.RESULTS: Out of the six stents, five stents were braided, the other was laser-cut. The RF and RFM of each stent were expressed as the average of five replicate measurements. For all six stents, RFM and RF decreased as the hole diameter increased. For all six stents, RFM and RF correlated strongly when the stent had not fully expanded. This correlation was not observed in the five braided stents excluding the laser cut stent. For all six stents, there was a strong correlation between RFM and TAF when the stent fully expanded. For the five braided stents, RFM after full stent expansion correlated strongly with all three stent flare structure variables(ODF, HF, and TAF). The laser-cut C-SEMS had higher RFMs than the braided C-SEMSs regardless of expansion state.CONCLUSION: RF was an important anti-migration property when the C-SEMS did not fully expand. Once fully expanded, stent flare structure variables plays an important role in anti-migration.