An equation model for calculating the adiabatic temperature of the wet-bulb thermometer has been obtained empirical fit through a meteorological database, specificly a trough relative humidity and air temperature. A c...An equation model for calculating the adiabatic temperature of the wet-bulb thermometer has been obtained empirical fit through a meteorological database, specificly a trough relative humidity and air temperature. A comparison of the results of calculations with the use of this equation and from meteorological database was made. The model deducted of the comparison is valid for a dry bulb temperature range of 3°C to 35°C and for relative humidity percentage in a range of 7% to 97%. Normalized errors are less than 5.5%. It means a maximum variation of 0.55°C from data. However, this variation from error represents only 3.6% of the data sample. The equation model was satisfactory.展开更多
Closed wet cooling towers(CWCTs) are used widely because of their better water quality and smaller water consumption. However, the operating parameters shown in the technical documents are only for rated conditions in...Closed wet cooling towers(CWCTs) are used widely because of their better water quality and smaller water consumption. However, the operating parameters shown in the technical documents are only for rated conditions in summer, not for any other conditions, especially in low air wet-bulb temperature areas such as those near 0℃. In addition, CWCTs often fail to achieve the designed cooling effect at low air wet-bulb temperatures. A experiment set of CWCT was built, and the performance of the CWCT at low air wet-bulb temperature near 0℃ was investigated. The impact of the operating parameters(air flow rate, cooling water flow rate, and spray water flow rate) on the heat and mass transfer performance of the CWCT was measured and analyzed. The results show the cooling performance of the CWCT at an air wet-bulb temperature 0℃, 2℃, and 4℃ is about 47%–63% of the rated operating condition;the optimal operating parameters of these conditions for the CWCT are just the same as those of the rated operating condition in summer. According to the experimental results, some operating advices are given.展开更多
文摘An equation model for calculating the adiabatic temperature of the wet-bulb thermometer has been obtained empirical fit through a meteorological database, specificly a trough relative humidity and air temperature. A comparison of the results of calculations with the use of this equation and from meteorological database was made. The model deducted of the comparison is valid for a dry bulb temperature range of 3°C to 35°C and for relative humidity percentage in a range of 7% to 97%. Normalized errors are less than 5.5%. It means a maximum variation of 0.55°C from data. However, this variation from error represents only 3.6% of the data sample. The equation model was satisfactory.
文摘Closed wet cooling towers(CWCTs) are used widely because of their better water quality and smaller water consumption. However, the operating parameters shown in the technical documents are only for rated conditions in summer, not for any other conditions, especially in low air wet-bulb temperature areas such as those near 0℃. In addition, CWCTs often fail to achieve the designed cooling effect at low air wet-bulb temperatures. A experiment set of CWCT was built, and the performance of the CWCT at low air wet-bulb temperature near 0℃ was investigated. The impact of the operating parameters(air flow rate, cooling water flow rate, and spray water flow rate) on the heat and mass transfer performance of the CWCT was measured and analyzed. The results show the cooling performance of the CWCT at an air wet-bulb temperature 0℃, 2℃, and 4℃ is about 47%–63% of the rated operating condition;the optimal operating parameters of these conditions for the CWCT are just the same as those of the rated operating condition in summer. According to the experimental results, some operating advices are given.