期刊文献+
共找到1,767篇文章
< 1 2 89 >
每页显示 20 50 100
A Tabletop Nano-CT Image Noise Reduction Network Based on 3-Dimensional Axial Attention Mechanism
1
作者 Huijuan Fu Linlin Zhu +5 位作者 ChunhuiWang Xiaoqi Xi Yu Han Lei Li Yanmin Sun Bin Yan 《Computers, Materials & Continua》 SCIE EI 2024年第7期1711-1725,共15页
Nano-computed tomography(Nano-CT)is an emerging,high-resolution imaging technique.However,due to their low-light properties,tabletop Nano-CT has to be scanned under long exposure conditions,which the scanning process ... Nano-computed tomography(Nano-CT)is an emerging,high-resolution imaging technique.However,due to their low-light properties,tabletop Nano-CT has to be scanned under long exposure conditions,which the scanning process is time-consuming.For 3D reconstruction data,this paper proposed a lightweight 3D noise reduction method for desktop-level Nano-CT called AAD-ResNet(Axial Attention DeNoise ResNet).The network is framed by theU-net structure.The encoder and decoder are incorporated with the proposed 3D axial attention mechanism and residual dense block.Each layer of the residual dense block can directly access the features of the previous layer,which reduces the redundancy of parameters and improves the efficiency of network training.The 3D axial attention mechanism enhances the correlation between 3D information in the training process and captures the long-distance dependence.It can improve the noise reduction effect and avoid the loss of image structure details.Experimental results show that the network can effectively improve the image quality of a 0.1-s exposure scan to a level close to a 3-s exposure,significantly shortening the sample scanning time. 展开更多
关键词 Deep learning tabletop Nano-CT image denoising 3D axial attention mechanism
下载PDF
Efficient single-pixel imaging encrypted transmission based on 3D Arnold transformation
2
作者 梁振宇 王朝瑾 +4 位作者 王阳阳 高皓琪 朱东涛 许颢砾 杨星 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期378-386,共9页
Single-pixel imaging(SPI)can transform 2D or 3D image data into 1D light signals,which offers promising prospects for image compression and transmission.However,during data communication these light signals in public ... Single-pixel imaging(SPI)can transform 2D or 3D image data into 1D light signals,which offers promising prospects for image compression and transmission.However,during data communication these light signals in public channels will easily draw the attention of eavesdroppers.Here,we introduce an efficient encryption method for SPI data transmission that uses the 3D Arnold transformation to directly disrupt 1D single-pixel light signals and utilizes the elliptic curve encryption algorithm for key transmission.This encryption scheme immediately employs Hadamard patterns to illuminate the scene and then utilizes the 3D Arnold transformation to permutate the 1D light signal of single-pixel detection.Then the transformation parameters serve as the secret key,while the security of key exchange is guaranteed by an elliptic curve-based key exchange mechanism.Compared with existing encryption schemes,both computer simulations and optical experiments have been conducted to demonstrate that the proposed technique not only enhances the security of encryption but also eliminates the need for complicated pattern scrambling rules.Additionally,this approach solves the problem of secure key transmission,thus ensuring the security of information and the quality of the decrypted images. 展开更多
关键词 single-pixel imaging 3D Arnold transformation elliptic curve encryption image encryption
下载PDF
Geant4 simulation of fast-electron bremsstrahlung imaging at the HL-3 tokamak
3
作者 Shi-Kui Cheng Yi-Po Zhang +4 位作者 Yue-Jiang Shi Jie Zhang Shuai Guan Hong-Bing Xu Qiu-Lei Yang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期213-229,共17页
To further research on high-parameter plasma,we plan to develop a two-dimensional hard X-ray(HXR)imaging system at the HL-3 tokamak to measure HXRs with energies ranging from 20 to 300 keV.The application of an array-... To further research on high-parameter plasma,we plan to develop a two-dimensional hard X-ray(HXR)imaging system at the HL-3 tokamak to measure HXRs with energies ranging from 20 to 300 keV.The application of an array-structured detector ensures that this system can measure HXR-radiation spectra from the entire plasma cross section.Therefore,it is suitable for the study of fast-electron physics,such as radio-frequency wave current drives,fast electrons driving instabilities,and plasma disruptions in fusion research.In this study,we develop a simulation for calculating fast-electron bremsstrahlung in the HL-3 tokamak based on the Monte Carlo simulation code Geant4,in which the plasma geometry and forward scattering of fast-electron bremsstrahlung are considered.The preliminary calculation results indicate that the HXR energy deposi-tion on the detector is symmetrically distributed,even though the plasma distribution is asymmetric owing to the toroidal effect.These simulation results are helpful in constructing the relationship between the energy deposition on the detector and parameter distribution on the plasma cross section during HL-3 experiments.This is beneficial for the reconstruction of the fast-electron-distribution function and for optimizing the design of the HXR-imaging system. 展开更多
关键词 GEANT4 SIMULATION HL-3 TOKAMAK Fast-electron bremsstrahlung Hard X-ray imaging
下载PDF
MACS-W:A modified optical clearing agent for imaging 3D cell cultures
4
作者 Xiang Zhong Chao Gao +6 位作者 Hui Li Yuening He Peng Fei Zaozao Chen Zhongze Gu Dan Zhu Tingting Yu 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第2期24-34,共11页
Three-dimensional(3D)cell cultures have contributed to a variety of biological research fields by filling the gap between monolayers and animal models.The modern optical sectioning microscopic methods make it possible... Three-dimensional(3D)cell cultures have contributed to a variety of biological research fields by filling the gap between monolayers and animal models.The modern optical sectioning microscopic methods make it possible to probe the complexity of 3D cell cultures but are limited by the inherent opaqueness.While tissue optical clearing methods have emerged as powerful tools for investigating whole-mount tissues in 3D,they often have limitations,such as being too harsh for fragile 3D cell cultures,requiring complex handling protocols,or inducing tissue deformation with shrinkage or expansion.To address this issue,we proposed a modified optical clearing method for 3D cell cultures,called MACS-W,which is simple,highly efficient,and morphology-preserving.In our evaluation of MACS-W,we found that it exhibits excellent clearing capability in just 10 min,with minimal deformation,and helps drug evaluation on tumor spheroids.In summary,MACS-W is a fast,minimally-deformative and fluorescence compatible clearing method that has the potential to be widely used in the studies of 3D cell cultures. 展开更多
关键词 Tissue optical clearing 3D cell cultures imaging
下载PDF
Magnetic resonance imaging combined with serum endolipin and galactagoglobin-3 to diagnose cerebral infarction in the elderly with diabetes mellitus
5
作者 Yan-Hui Zhang Dong Liang 《World Journal of Diabetes》 SCIE 2024年第7期1509-1517,共9页
BACKGROUND Magnetic resonance imaging(MRI)combined with serum endothelin and galactagoglobin-3(Gal-3)can improve the clinical diagnosis of diabetes mellitus complicated with cerebral infarction.AIM To analyze the clin... BACKGROUND Magnetic resonance imaging(MRI)combined with serum endothelin and galactagoglobin-3(Gal-3)can improve the clinical diagnosis of diabetes mellitus complicated with cerebral infarction.AIM To analyze the clinical value of MRI combined with serum endolipin and Gal-3 for the diagnosis of cerebral infarction in the elderly with diabetes mellitus.METHODS One hundred and fifty patients with acute cerebral infarction hospitalized between January 2021 and December 2023 were divided into two groups according to comorbid diabetes mellitus,including 62 and 88 cases in the diabetic and nondiabetic cerebral infarction groups.Serum samples were collected to detect the expression of serum endolipoxins,and Gal-3,and cranial MRI was performed at admission.Differences between the two groups were compared to analyze the diagnostic value of these parameters.RESULTS Serum endolipin and Gal-3 expression were higher in the diabetic cerebral infarction group(P<0.05).The arterial wall area,vessel area,normalized wall index,and lumen stenosis rate were higher in the diabetic cerebral infarction group,while the rate of arterial lumen moderate and severe stenosis was 48.39% higher(36.36%,P<0.05).The percentage of large(29.03%)and multiple infarcts(33.87%)in the diabetic cerebral infarction group was higher(13.64% and 20.45%),and the incidence rate of lacunar infarcts was lower(37.10%vs 65.91%)(P<0.05).The total incidence of arterial plaque in patients in the diabetic cerebral infarction group was 96.77% higher(69.32%),while the incidence of necrotic lipid core plaque was 58.06%higher(26.14%)(P<0.05).Receiver operating characteristic curve analysis was performed to assess the diagnosis utility of these techniques.MRI in combination with serum endoglin and Gal-3 had the highest area under the curve,the Yoden index,sensitivity and specificity(P<0.05).CONCLUSION The expression of serum endolipin and Gal-3 in elderly patients with diabetes mellitus with cerebral infarction showed an elevated trend,and the degree of luminal stenosis was severe.MRI predominantly revealed large and multiple infarct foci.This combined index examination can improve the clinical diagnosis of diabetes mellitus combined with cerebral infarction. 展开更多
关键词 Endolipin GALECTIN-3 Magnetic resonance imaging Elderly Diabetes mellitus Cerebral infarction
下载PDF
Non-invasively differentiate non-alcoholic steatohepatitis by visualizing hepatic integrinαvβ3 expression with a targeted molecular imaging modality
6
作者 Xiao-Quan Huang Ling Wu +7 位作者 Chun-Yan Xue Chen-Yi Rao Qing-Qing Fang Ying Chen Cao Xie Sheng-Xiang Rao Shi-Yao Chen Feng Li 《World Journal of Hepatology》 2024年第11期1290-1305,共16页
BACKGROUND Non-invasive methods to diagnose non-alcoholic steatohepatitis(NASH),an inflammatory subtype of non-alcoholic fatty liver disease(NAFLD),are currently unavailable.AIM To develop an integrinαvβ3-targeted m... BACKGROUND Non-invasive methods to diagnose non-alcoholic steatohepatitis(NASH),an inflammatory subtype of non-alcoholic fatty liver disease(NAFLD),are currently unavailable.AIM To develop an integrinαvβ3-targeted molecular imaging modality to differentiate NASH.METHODS Integrinαvβ3 expression was assessed in Human LO2 hepatocytes Scultured with palmitic and oleic acids(FFA).Hepatic integrinαvβ3 expression was analyzed in rabbits fed a high-fat diet(HFD)and in rats fed a high-fat,high-carbohydrate diet(HFCD).After synthesis,cyclic arginine-glycine-aspartic acid peptide(cRGD)was labeled with gadolinium(Gd)and used as a contrast agent in magnetic resonance imaging(MRI)performed on mice fed with HFCD.RESULTS Integrinαvβ3 was markedly expressed on FFA-cultured hepatocytes,unlike the control hepatocytes.Hepatic integrinαvβ3 expression significantly increased in both HFD-fed rabbits and HFCD-fed rats as simple fatty liver(FL)progressed to steatohepatitis.The distribution of integrinαvβ3 in the liver of NASH cases largely overlapped with albumin-positive staining areas.In comparison to mice with simple FL,the relative liver MRI-T1 signal value at 60 minutes post-injection of Gd-labeled cRGD was significantly increased in mice with steatohepatitis(P<0.05),showing a positive correlation with the NAFLD activity score(r=0.945;P<0.01).Hepatic integrinαvβ3 expression was significantly upregulated during NASH development,with hepatocytes being the primary cells expressing integrinαvβ3.CONCLUSION After using Gd-labeled cRGD as a tracer,NASH was successfully distinguished by visualizing hepatic integrinαvβ3 expression with MRI. 展开更多
关键词 Non-alcoholic steatohepatitis Cyclic peptides Magnetic resonance imaging Non-invasive diagnosis Hepatic integrinαvβ3
下载PDF
Evaluation of Airway Obstruction at Soft Palate Level in Male Patients with Obstructive Sleep Apnea/Hypopnea Syndrome:Dynamic 3-Dimensional CT Imaging of Upper Airway 被引量:10
7
作者 肖英 陈雄 +4 位作者 史河水 杨阳 何烈纯 董家琪 孔维佳 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2011年第3期413-418,共6页
This study examined the dynamic characteristics of upper airway collapse at soft palate level in patients with obstructive sleep apnea/hypopnea syndrome(OSAHS) by using dynamic 3-Dimensional(3-D) CT imaging.A tota... This study examined the dynamic characteristics of upper airway collapse at soft palate level in patients with obstructive sleep apnea/hypopnea syndrome(OSAHS) by using dynamic 3-Dimensional(3-D) CT imaging.A total of 41 male patients who presented with 2 of the following symptoms,i.e.,daytime sleepiness and fatigue,frequent snoring,and apnea with witness,were diagnosed as having OSAHS.They underwent full-night polysomnography and then dynamic 3-D CT imaging of the upper airway during quiet breathing and in Muller's maneuver.The soft palate length(SPL),the minimal cross-sectional area of the retropalatal region(mXSA-RP),and the vertical distance from the hard palate to the upper posterior part of the hyoid(hhL) were compared between the two breathing states.These parameters,together with hard palate length(HPL),were also compared between mild/moderate and severe OSAHS groups.Association of these parameters with the severity of OSAHS [as reflected by apnea hypopnea index(AHI) and the lowest saturation of blood oxygen(LSaO2)] was examined.The results showed that 31 patients had severe OSAHS,and 10 mild/moderate OSAHS.All the patients had airway obstruction at soft palate level.mXSA-RP was significantly decreased and SPL remarkably increased during Muller's maneuver as compared with the quiet breathing state.There were no significant differences in these airway parameters(except the position of the hyoid bone) between severe and mild/moderate OSAHS groups.And no significant correlation between these airway parameters and the severity of OSAHS was found.The position of hyoid was lower in the severe OSAHS group than in the mild/moderate OSAHS group.The patients in group with body mass index(BMI)≥26 had higher collapse ratio of mXSA-RP,greater neck circumference and smaller mXSA-RP in the Muller's maneuver than those in group with BMI26(P0.05 for all).It was concluded that dynamic 3-D CT imaging could dynamically show the upper airway changes at soft palate level in OSAHS patients.All the OSAHS patients had airway obstruction of various degrees at soft palate level.But no correlation was observed between the airway change at soft palate level and the severity of OSAHS.The patients in group with BMI≥26 were more likely to develop airway obstruction at soft palate level than those with BMI26. 展开更多
关键词 obstructive sleep apnea/hypopnea syndrome upper airway obstruction soft palate level dynamic computed tomography 3-dimensional imaging
下载PDF
The Application Value of Ultrasound Imaging in the Differential Diagnosis of Benign and Malignant Breast Nodules of BI-RADS 3 and Above
8
作者 Dongmei Chen 《Proceedings of Anticancer Research》 2024年第2期53-58,共6页
Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast ... Objective:To explore the diagnostic value of ultrasound imaging for breast nodules of breast imaging-reporting and data system(BI-RADS)category 3 and above.Methods:From June 2021 to July 2022,163 patients with breast nodules of BI-RADS 3 or above were selected as the research subjects.After pathological diagnosis,24 cases were malignant breast nodules of BI-RADS 3 or above,while 139 cases were benign breast nodules of BI-RADS 3 or above.The diagnosis rate of malignant and benign breast nodules of BI-RADS 3 or above,including 95%CI,was observed and analyzed.Results:The malignant and benign detection rates of conventional ultrasound were 88.63%and 75.00%,respectively,and the malignant and benign detection rates of ultrasound imaging were 93.18%and 87.50%,respectively,with 95%CIs greater than 0.7.Conclusion:Ultrasound imaging can help improve the diagnostic accuracy of benign and malignant breast nodules of BI-RADS 3 and above and reduce the misdiagnosis rate. 展开更多
关键词 ULTRASOUND Ultrasound imaging Breast imaging-reporting and data system(BI-RADS)category 3 and above Diagnosis
下载PDF
3-Dimensional Irradiance Imaging with a Single Camera System
9
作者 陆永刚 王式民 +1 位作者 朱震 徐益谦 《Journal of Southeast University(English Edition)》 EI CAS 1998年第2期40-44,共5页
The focusing tomography is presented to reconstruct 3 dimensional irradiance distribution. A 3 dimensional luminous body could be considered as the combination of many 2 dimensional parallel luminous sections. Focu... The focusing tomography is presented to reconstruct 3 dimensional irradiance distribution. A 3 dimensional luminous body could be considered as the combination of many 2 dimensional parallel luminous sections. Focus on these discrete sections respectively by a single camera, a group of images would be captured to form governing equations of irradiance. After inversion procedure, the irradiance distribution of different sections could be decoded. In this experimentation two lightbulbs are used to simulate two luminous sections. Reasonable results demonstrate that this technique could be a useful method in irradiance reconstruction after further development. 展开更多
关键词 focusing tomography 3 dimensional irradiance reconstruction image
下载PDF
Three-dimensional imaging identified the accessory bile duct in a patient with cholangiocarcinoma 被引量:7
10
作者 Ryoichi Miyamoto Yukio Oshiro +4 位作者 Shinji Hashimoto Keisuke Kohno Kiyoshi Fukunaga Tatsuya Oda Nobuhiro Ohkohchi 《World Journal of Gastroenterology》 SCIE CAS 2014年第32期11451-11455,共5页
The development of diagnostic imaging technology, such as multidetector computed tomography(MDCT) and magnetic resonance cholangiopancreatography(MRCP), has made it possible to obtain detailed images of the bile duct.... The development of diagnostic imaging technology, such as multidetector computed tomography(MDCT) and magnetic resonance cholangiopancreatography(MRCP), has made it possible to obtain detailed images of the bile duct. Recent reports have indicated that a 3-dimensional(3D) reconstructed imaging system would be useful for understanding the liver anatomy before surgery. We have investigated a novel method that fuses MDCT and MRCP images. This novel system easily made it possible to detect the anatomical relationship between the vessels and bile duct in the portal hepatis. In this report, we describe a very rare case of extrahepatic cholangiocarcinoma associated with an accessory bile duct from the caudate lobe connecting with the intrapancreatic bile duct. We were unable to preoperatively detect this accessory bile duct using MDCT and MRCP. However, prior to the second operation, we were able to clearly visualise the injured accessory bile duct using our novel 3D imaging modality. In thisreport, we suggest that this imaging technique can be considered a novel and useful modality for understanding the anatomy of the portal hepatis, including the hilar bile duct. 展开更多
关键词 3-dimensional imaging Hepatobiliary and pancreatic surgery Accessory bile duct Caudate lobe bile duct CHOLANGIOCARCINOMA
下载PDF
A Rare Case of Concordant Atrioventricular Connection to L-Looped Ventricles in Situs Solitus:4-Dimensional Magnetic Resonance Imaging and 3D Printing
11
作者 Gregory Perens Takegawa Yoshida J.Paul Finn 《Congenital Heart Disease》 SCIE 2022年第4期387-392,共6页
An infant male presented with the rare anatomy consisting of situs solitus,concordant atrioventricular connections to L-looped ventricles,double outlet right ventricle(DORV),and hypoplastic aortic arch.6 months after ... An infant male presented with the rare anatomy consisting of situs solitus,concordant atrioventricular connections to L-looped ventricles,double outlet right ventricle(DORV),and hypoplastic aortic arch.6 months after neonatal aortic arch repair,the morphologic right ventricle function deteriorated,and surgical evaluation was undertaken to determine if either biventricular repair with a systemic morphologic left ventricle or right ventricular exclusion was possible.After initial echocardiography,magnetic resonance imaging(MRI)was used to create detailed axial and 4-dimensional(4D)images and 3-dimensional(3D)printed models.The detailed anatomy of this rare,complex case and its use in pre-surgical planning is presented. 展开更多
关键词 Magnetic resonance imaging cardiac segments 3D printing
下载PDF
Stimulated Raman scattering microscopy with phase-controlled light focusing and aberration correction for rapid and label-free, volumetric deep tissue imaging
12
作者 Weiqi Wang Zhiwei Huang 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第9期40-52,共13页
We report a novel stimulated Raman scattering(SRS)microscopy technique featuring phase-controlled light focusing and aberration corrections for rapid,deep tissue 3D chemical imaging with subcellular resolution.To acco... We report a novel stimulated Raman scattering(SRS)microscopy technique featuring phase-controlled light focusing and aberration corrections for rapid,deep tissue 3D chemical imaging with subcellular resolution.To accomplish phasecontrolled SRS(PC-SRS),we utilize a single spatial light modulator to electronically tune the axial positioning of both the shortened-length Bessel pump and the focused Gaussian Stokes beams,enabling z-scanning-free optical sectioning in the sample.By incorporating Zernike polynomials into the phase patterns,we simultaneously correct the system aberrations at two separate wavelengths(~240 nm difference),achieving a~3-fold enhancement in signal-to-noise ratio over the uncorrected imaging system.PC-SRS provides>2-fold improvement in imaging depth in various samples(e.g.,polystyrene bead phantoms,porcine brain tissue)as well as achieves SRS 3D imaging speed of~13 Hz per volume for real-time monitoring of Brownian motion of polymer beads in water,superior to conventional point-scanning SRS 3D imaging.We further utilize PC-SRS to observe the metabolic activities of the entire tumor liver in living zebrafish in cellsilent region,unraveling the upregulated metabolism in liver tumor compared to normal liver.This work shows that PCSRS provides unprecedented insights into morpho-chemistry,metabolic and dynamic functioning of live cells and tissue in real-time at the subcellular level. 展开更多
关键词 SRS 3D imaging phase-controlled light focusing image aberration corrections deep tissue imaging
下载PDF
Development and prospect of acoustic reflection imaging logging processing and interpretation method
13
作者 LI Ning LIU Peng +5 位作者 WU Hongliang LI Yusheng ZHANG Wenhao WANG Kewen FENG Zhou WANG Hao 《Petroleum Exploration and Development》 SCIE 2024年第4期839-851,共13页
Acoustic reflection imaging logging technology can detect and evaluate the development of reflection anomalies,such as fractures,caves and faults,within a range of tens of meters from the wellbore,greatly expanding th... Acoustic reflection imaging logging technology can detect and evaluate the development of reflection anomalies,such as fractures,caves and faults,within a range of tens of meters from the wellbore,greatly expanding the application scope of well logging technology.This article reviews the development history of the technology and focuses on introducing key methods,software,and on-site applications of acoustic reflection imaging logging technology.Based on the analyses of major challenges faced by existing technologies,and in conjunction with the practical production requirements of oilfields,the further development directions of acoustic reflection imaging logging are proposed.Following the current approach that utilizes the reflection coefficients,derived from the computation of acoustic slowness and density,to perform seismic inversion constrained by well logging,the next frontier is to directly establish the forward and inverse relationships between the downhole measured reflection waves and the surface seismic reflection waves.It is essential to advance research in imaging of fractures within shale reservoirs,the assessment of hydraulic fracturing effectiveness,the study of geosteering while drilling,and the innovation in instruments of acoustic reflection imaging logging technology. 展开更多
关键词 acoustic reflection imaging monopole P-waves dipole S-waves horizontal well acoustic reflection imaging 3D imaging well logging-seismic integration CIFLog software
下载PDF
Two-photon polymerization lithography for imaging optics
14
作者 Hao Wang Cheng-Feng Pan +16 位作者 Chi Li Kishan S Menghrajani Markus A Schmidt Aoling Li Fu Fan Yu Zhou Wang Zhang Hongtao Wang Parvathi Nair Suseela Nair John You En Chan Tomohiro Mori Yueqiang Hu Guangwei Hu Stefan A Maier Haoran Ren Huigao Duan Joel K W Yang 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2024年第4期21-60,共40页
Optical imaging systems have greatly extended human visual capabilities,enabling the observation and understanding of diverse phenomena.Imaging technologies span a broad spectrum of wavelengths from x-ray to radio fre... Optical imaging systems have greatly extended human visual capabilities,enabling the observation and understanding of diverse phenomena.Imaging technologies span a broad spectrum of wavelengths from x-ray to radio frequencies and impact research activities and our daily lives.Traditional glass lenses are fabricated through a series of complex processes,while polymers offer versatility and ease of production.However,modern applications often require complex lens assemblies,driving the need for miniaturization and advanced designs with micro-and nanoscale features to surpass the capabilities of traditional fabrication methods.Three-dimensional(3D)printing,or additive manufacturing,presents a solution to these challenges with benefits of rapid prototyping,customized geometries,and efficient production,particularly suited for miniaturized optical imaging devices.Various 3D printing methods have demonstrated advantages over traditional counterparts,yet challenges remain in achieving nanoscale resolutions.Two-photon polymerization lithography(TPL),a nanoscale 3D printing technique,enables the fabrication of intricate structures beyond the optical diffraction limit via the nonlinear process of two-photon absorption within liquid resin.It offers unprecedented abilities,e.g.alignment-free fabrication,micro-and nanoscale capabilities,and rapid prototyping of almost arbitrary complex 3D nanostructures.In this review,we emphasize the importance of the criteria for optical performance evaluation of imaging devices,discuss material properties relevant to TPL,fabrication techniques,and highlight the application of TPL in optical imaging.As the first panoramic review on this topic,it will equip researchers with foundational knowledge and recent advancements of TPL for imaging optics,promoting a deeper understanding of the field.By leveraging on its high-resolution capability,extensive material range,and true 3D processing,alongside advances in materials,fabrication,and design,we envisage disruptive solutions to current challenges and a promising incorporation of TPL in future optical imaging applications. 展开更多
关键词 two-photon polymerization lithography 3D printing additive manufacturing imaging optics and nanophotonics
下载PDF
A"messenger zone hypothesis"based on the visual three-dimensional spatial distribution of motoneurons innervating deep limb muscles
15
作者 Chen Huang Shen Wang +3 位作者 Jin Deng Xinyi Gu Shuhang Guo Xiaofeng Yin 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第7期1559-1567,共9页
Coordinated contraction of skeletal muscles relies on selective connections between the muscles and multiple classes of the spinal motoneuro ns.Howeve r,current research on the spatial location of the spinal motoneuro... Coordinated contraction of skeletal muscles relies on selective connections between the muscles and multiple classes of the spinal motoneuro ns.Howeve r,current research on the spatial location of the spinal motoneurons innervating differe nt muscles is limited.In this study,we investigated the spatial distribution and relative position of different motoneurons that control the deep muscles of the mouse hindlimbs,which were innervated by the obturator nerve,femoral nerve,inferior gluteal nerve,deep pe roneal nerve,and tibial nerve.Locations were visualized by combining a multiplex retrograde tracking technique compatible with three-dimensional imaging of solvent-cleared o rgans(3DISCO)and 3-D imaging technology based on lightsheet fluorescence microscopy(LSFM).Additionally,we propose the hypothesis that"messenger zones"exist as interlaced areas between the motoneuron pools that dominate the synergistic or antagonist muscle groups.We hypothesize that these interlaced neurons may participate in muscle coordination as messenger neurons.Analysis revealed the precise mutual positional relationships among the many motoneurons that innervate different deep muscles of the mouse.Not only do these findings update and supplement our knowledge regarding the overall spatial layout of spinal motoneurons that control mouse limb muscles,but they also provide insights into the mechanisms through which muscle activity is coordinated and the architecture of motor circuits. 展开更多
关键词 3-D imaging MOTONEURONS multiple retrograde tracing muscle coordination skeletal muscle spatial distribution optical tissue clearing
下载PDF
3D imaging lipidometry in single cell by in-flow holographic tomography 被引量:1
16
作者 Daniele Pirone Daniele Sirico +10 位作者 Lisa Miccio Vittorio Bianco Martina Mugnano Danila del Giudice Gianandrea Pasquinelli Sabrina Valente Silvia Lemma Luisa Iommarini Ivana Kurelac Pasquale Memmolo Pietro Ferraro 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第1期10-25,共16页
The most recent discoveries in the biochemical field are highlighting the increasingly important role of lipid droplets(LDs)in several regulatory mechanisms in living cells.LDs are dynamic organelles and therefore the... The most recent discoveries in the biochemical field are highlighting the increasingly important role of lipid droplets(LDs)in several regulatory mechanisms in living cells.LDs are dynamic organelles and therefore their complete characterization in terms of number,size,spatial positioning and relative distribution in the cell volume can shed light on the roles played by LDs.Until now,fluorescence microscopy and transmission electron microscopy are assessed as the gold standard methods for identifying LDs due to their high sensitivity and specificity.However,such methods generally only provide 2D assays and partial measurements.Furthermore,both can be destructive and with low productivity,thus limiting analysis of large cell numbers in a sample.Here we demonstrate for the first time the capability of 3D visualization and the full LD characterization in high-throughput with a tomographic phase-contrast flow-cytometer,by using ovarian cancer cells and monocyte cell lines as models.A strategy for retrieving significant parameters on spatial correlations and LD 3D positioning inside each cell volume is reported.The information gathered by this new method could allow more in depth understanding and lead to new discoveries on how LDs are correlated to cellular functions. 展开更多
关键词 lipid droplets label-free phase-contrast imaging in-flow tomography 3D imaging
下载PDF
Integral imaging-based tabletop light field 3D display with large viewing angle 被引量:2
17
作者 Yan Xing Xing-Yu Lin +9 位作者 Lin-Bo Zhang Yun-Peng Xia Han-Le Zhang Hong-Yu Cui Shuang Li Tong-Yu Wang Hui Ren Di Wang Huan Deng Qiong-Hua Wang 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第6期19-30,共12页
Light field 3D display technology is considered a revolutionary technology to address the critical visual fatigue issues in the existing 3D displays.Tabletop light field 3D display provides a brand-new display form th... Light field 3D display technology is considered a revolutionary technology to address the critical visual fatigue issues in the existing 3D displays.Tabletop light field 3D display provides a brand-new display form that satisfies multi-user shared viewing and collaborative works,and it is poised to become a potential alternative to the traditional wall and portable display forms.However,a large radial viewing angle and correct radial perspective and parallax are still out of reach for most current tabletop light field 3D displays due to the limited amount of spatial information.To address the viewing angle and perspective issues,a novel integral imaging-based tabletop light field 3D display with a simple flat-panel structure is proposed and developed by applying a compound lens array,two spliced 8K liquid crystal display panels,and a light shaping diffuser screen.The compound lens array is designed to be composed of multiple three-piece compound lens units by employing a reverse design scheme,which greatly extends the radial viewing angle in the case of a limited amount of spatial information and balances other important 3D display parameters.The proposed display has a radial viewing angle of 68.7°in a large display size of 43.5 inches,which is larger than the conventional tabletop light field 3D displays.The radial perspective and parallax are correct,and high-resolution 3D images can be reproduced in large radial viewing positions.We envision that this proposed display opens up possibility for redefining the display forms of consumer electronics. 展开更多
关键词 tabletop light field 3D display integral imaging compound lens array radial viewing angle
下载PDF
Clinical study on improving the diagnostic accuracy of adult elbow joint cartilage injury by multisequence magnetic resonance imaging
18
作者 Wei-Wei Ding Lei Ding +6 位作者 Li Li Pan Zhang Rui Gong Jian Li Meng-Ying Xu Feng Ding Bing Chen 《World Journal of Clinical Cases》 SCIE 2024年第25期5673-5680,共8页
BACKGROUND Due to frequent and high-risk sports activities,the elbow joint is susceptible to injury,especially to cartilage tissue,which can cause pain,limited movement and even loss of joint function.AIM To evaluate ... BACKGROUND Due to frequent and high-risk sports activities,the elbow joint is susceptible to injury,especially to cartilage tissue,which can cause pain,limited movement and even loss of joint function.AIM To evaluate magnetic resonance imaging(MRI)multisequence imaging for improving the diagnostic accuracy of adult elbow cartilage injury.METHODS A total of 60 patients diagnosed with elbow cartilage injury in our hospital from January 2020 to December 2021 were enrolled in this retrospective study.We analyzed the accuracy of conventional MRI sequences(T1-weighted imaging,T2-weighted imaging,proton density weighted imaging,and T2 star weighted image)and Three-Dimensional Coronary Imaging by Spiral Scanning(3D-CISS)in the diagnosis of elbow cartilage injury.Arthroscopy was used as the gold standard to evaluate the diagnostic effect of single and combination sequences in different injury degrees and the consistency with arthroscopy.RESULTS The diagnostic accuracy of 3D-CISS sequence was 89.34%±4.98%,the sensitivity was 90%,and the specificity was 88.33%,which showed the best performance among all sequences(P<0.05).The combined application of the whole sequence had the highest accuracy in all sequence combinations,the accuracy of mild injury was 91.30%,the accuracy of moderate injury was 96.15%,and the accuracy of severe injury was 93.33%(P<0.05).Compared with arthroscopy,the combination of all MRI sequences had the highest consistency of 91.67%,and the kappa value reached 0.890(P<0.001).CONCLUSION Combination of 3D-CISS and each sequence had significant advantages in improving MRI diagnostic accuracy of elbow cartilage injuries in adults.Multisequence MRI is recommended to ensure the best diagnosis and treatment. 展开更多
关键词 MRI multisequence imaging Cartilage injury of elbow joint Accuracy of diagnosis ARTHROSCOPY 3D-CISS
下载PDF
Anisotropic creep behavior of soft-hard interbedded rock masses based on 3D printing and digital imaging correlation technology 被引量:1
19
作者 TIAN Yun WU Fa-quan +5 位作者 TIAN Hong-ming LI Zhe SHU Xiao-yun HE Lin-kai HUANG Man CHEN Wei-zhong 《Journal of Mountain Science》 SCIE CSCD 2023年第4期1147-1158,共12页
Three-dimensional(3D)printing technology is increasingly used in experimental research of geotechnical engineering.Compared to other materials,3D layer-by-layer printing specimens are extremely similar to the inherent... Three-dimensional(3D)printing technology is increasingly used in experimental research of geotechnical engineering.Compared to other materials,3D layer-by-layer printing specimens are extremely similar to the inherent properties of natural layered rock masses.In this paper,soft-hard interbedded rock masses with different dip angles were prepared based on 3D printing(3DP)sand core technology.Uniaxial compression creep tests were conducted to investigate its anisotropic creep behavior based on digital imaging correlation(DIC)technology.The results show that the anisotropic creep behavior of the 3DP soft-hard interbedded rock mass is mainly affected by the dip angles of the weak interlayer when the stress is at low levels.As the stress level increases,the effect of creep stress on its creep anisotropy increases significantly,and the dip angle is no longer the main factor.The minimum value of the long-term strength and creep failure strength always appears in the weak interlayer within 30°–60°,which explains why the failure of the layered rock mass is controlled by the weak interlayer and generally emerges at 45°.The tests results are verified by comparing with theoretical and other published studies.The feasibility of the 3DP soft-hard interbedded rock mass provides broad prospects and application values for 3DP technology in future experimental research. 展开更多
关键词 3D printing Soft-hard interbedded rock mass Digital imaging correlation technology Weak interlayer Anisotropic creep
下载PDF
Airborne sparse flight array SAR 3D imaging based on compressed sensing in frequency domain 被引量:1
20
作者 TIAN He DONG Chunzhu +1 位作者 YIN Hongcheng YUAN Li 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2023年第1期56-67,共12页
In airborne array synthetic aperture radar(SAR), the three-dimensional(3D) imaging performance and cross-track resolution depends on the length of the equivalent array. In this paper, Barker sequence criterion is used... In airborne array synthetic aperture radar(SAR), the three-dimensional(3D) imaging performance and cross-track resolution depends on the length of the equivalent array. In this paper, Barker sequence criterion is used for sparse flight sampling of airborne array SAR, in order to obtain high cross-track resolution in as few times of flights as possible. Under each flight, the imaging algorithm of back projection(BP) and the data extraction method based on modified uniformly redundant arrays(MURAs) are utilized to obtain complex 3D image pairs. To solve the side-lobe noise in images, the interferometry between each image pair is implemented, and compressed sensing(CS) reconstruction is adopted in the frequency domain. Furthermore, to restore the geometrical relationship between each flight, the phase information corresponding to negative MURA is compensated on each single-pass image reconstructed by CS. Finally,by coherent accumulation of each complex image, the high resolution in cross-track direction is obtained. Simulations and experiments in X-band verify the availability. 展开更多
关键词 three-dimensional(3D)imaging synthetic aperture radar(SAR) sparse flight INTERFEROMETRY compressed sensing(CS)
下载PDF
上一页 1 2 89 下一页 到第
使用帮助 返回顶部