The magnetic field profiles,which are produced by three ways in the deposition chamber and plasma chamber of single coil divergent field MWECR CVD system,are investigated.The magnetic field gradient of these magnetic ...The magnetic field profiles,which are produced by three ways in the deposition chamber and plasma chamber of single coil divergent field MWECR CVD system,are investigated.The magnetic field gradient of these magnetic field profiles is obtained quantitatively by using Lorentz fit.The results indicate that the gradient value of the magnetic field profile near by the substrate,which is produced by a coil current with 137.7A if a SmCo permanent magnet is equipped under the substrate holder,is the largest;when the SmCo permanent magnet is taken away,the larger one is produced by the coil current with 137.7A and the smallest one produced by a coil current with 115.2A.High deposition rate of a-Si∶H film is observed near by the substrate with high magnetic field gradient.But uneven deposition rate along the radius of the sample holder is also found by infrared analysis technology when sample is deposited in magnetic field profile,which is produced by the coil current with 137.7A if the SmCo permanent magnet is equipped under the substrate holder.展开更多
A method of measuring in-situ magnetic field gradient is proposed in this paper. The magnetic shield is widely used in the atomic magnetometer. However, there is magnetic field gradient in the magnetic shield, which w...A method of measuring in-situ magnetic field gradient is proposed in this paper. The magnetic shield is widely used in the atomic magnetometer. However, there is magnetic field gradient in the magnetic shield, which would lead to additional gradient broadening. It is impossible to use an ex-situ magnetometer to measure magnetic field gradient in the region of a cell, whose length of side is several centimeters. The method demonstrated in this paper can realize the in-situ measurement of the magnetic field gradient inside the cell, which is significant for the spin relaxation study. The magnetic field gradients along the longitudinal axis of the magnetic shield are measured by a spin-exchange relaxation-free (SERF) magnetometer by adding a magnetic field modulation in the probe beam's direction. The transmissivity of the cell for the probe beam is always inhomogeneous along the pump beam direction, and the method proposed in this paper is independent of the intensity of the probe beam, which means that the method is independent of the cell's transmissivity. This feature makes the method more practical experimentally. Moreover, the AC-Stark shift can seriously degrade and affect the precision of the magnetic field gradient measurement. The AC-Stark shift is suppressed by locking the pump beam to the resonance of potassium's D1 line. Furthermore, the residual magnetic fields are measured with σ+- and σ--polarized pump beams, which can further suppress the effect of the AC-Stark shift. The method of measuring in-situ magnetic field gradient has achieved a magnetic field gradient precision of better than 30 pT/mm.展开更多
The effect of the Raman-pulse duration related to the magnetic field gradient, as a systematic error, is playing an important role on evaluating the performance of high-precision atomic gravimeters. We study this effe...The effect of the Raman-pulse duration related to the magnetic field gradient, as a systematic error, is playing an important role on evaluating the performance of high-precision atomic gravimeters. We study this effect with a simplified theoretical model of the time-propagation operator. According to the typical parameters, we find that this effect should be taken into account when the gravimeter reaches an accuracy of 10^-10g, and the larger the pulse duration is, the more obvious the systematic effect will be. Finally, we make a simple discussion on the possibility of testing this effect.展开更多
Although 9.4 T magnetic resonance imaging(MRI) has been tested in healthy volunteers,its safety in diabetic patients is unclear.Furthermore,the effects of high static magnetic fields(SMFs),especially gradient vs.unifo...Although 9.4 T magnetic resonance imaging(MRI) has been tested in healthy volunteers,its safety in diabetic patients is unclear.Furthermore,the effects of high static magnetic fields(SMFs),especially gradient vs.uniform fields,have not been investigated in diabetics.Here,we investigated the consequences of exposure to 1.0-9.4 T high SMFs of different gradients(>10 T/m vs.0-10 T/m)on type 1 diabetic(T1D) and type 2 diabetic(T2D) mice.We found that 14 h of prolonged treatment of gradient(as high as 55.5 T/m) high SMFs(1.0-8.6 T) had negative effects on T1D and T2D mice,including spleen,hepatic,and renal tissue impairment and elevated glycosylated serum protein,blood glucose,inflammation,and anxiety,while 9.4 T quasi-uniform SMFs at 0-10 T/m did not induce the same effects.In regular T1D mice(blood glucose>16.7 mmol/L),the>10 T/m gradient high SMFs increased malondialdehyde(P<0.01) and decreased superoxide dismutase(P<0.05).However,in the severe T1D mice(blood glucose≥30.0 mmol/L),the>10 T/m gradient high SMFs significantly increased tissue damage and reduced survival rate.In vitro cellular studies showed that gradient high SMFs increased cellular reactive oxygen species and apoptosis and reduced MS-1 cell number and proliferation.Therefore,this study showed that prolonged exposure to high-field(1.0-8.6 T)>10 T/m gradient SMFs(35-1 380 times higher than that of current clinical MRI)can have negative effects on diabetic mice,especially mice with severe T1D,whereas 9.4 T high SMFs at 0-10T/m did not produce the same effects,providing important information for the future development and clinical application of SMFs,especially high-field MRI.展开更多
We consider a cantilever mechanical oscillator(MO) made of diamond. A nitrogen-vacancy(NV) center lies at the end of the cantilever. Two magnetic tips near the NV center induce a strong second-order magnetic field gra...We consider a cantilever mechanical oscillator(MO) made of diamond. A nitrogen-vacancy(NV) center lies at the end of the cantilever. Two magnetic tips near the NV center induce a strong second-order magnetic field gradient. Under coherent driving of the MO, we find that the coupling between the MO and the NV center is greatly enhanced. We studied how to generate entanglement between the MO and the NV center and realize quantum state transfer between them. We also propose a scheme to generate two-mode squeezing between different MO modes by coupling them to the same NV center. The decoherence and dissipation effects for both the MO and the NV center are numerically calculated using the present parameter values of the experimental configuration. We have achieved high fidelity for entanglement generation, quantum state transfer, and large twomode squeezing.展开更多
In this study,the effects of high magnetic field gradients on the segregation of alloying elements,crystallized phases,and particles in alloys during solidification process and corresponding microstructures were discu...In this study,the effects of high magnetic field gradients on the segregation of alloying elements,crystallized phases,and particles in alloys during solidification process and corresponding microstructures were discussed.It was confirmed that applying an external high magnetic field gradient during solidification process is an effective processing route for controlling segregation in alloys and then fabricating functional materials which have special mierostruetures and properties.Such controlling and fabrication were realized by controlling the migration of the alloying elements, crystallized phases,and particles in the liquid matrix on the basis of the Lorentz and magnetic forces.展开更多
Optically levitated nano-particle with spins is a promising system for high-precision measurement and quantum information processing. We theoretically analyze the ratio between the fluctuation of particle's displa...Optically levitated nano-particle with spins is a promising system for high-precision measurement and quantum information processing. We theoretically analyze the ratio between the fluctuation of particle's displacement caused by spins in magnetic field and caused by molecular collisions of the residual air. When the ratio is larger than unity, the displacement fluctuation of spins flipping can be remarkably detected. By theoretical analysis and numerical simulation, we propose and validate a scheme for the detection of gradient of the magnetic field by levitating ferromagnetic nano-particle, and also put forward a realizable detection scheme of the single spin by levitating nano-diamond particle with single nitrogen-vacancy(NV) centers.展开更多
We present a review of the principal developments in the evolution and synergism of solute and particle migration in a liquid melt in high-gradient magnetic fields and we also describe their effects on the solidificat...We present a review of the principal developments in the evolution and synergism of solute and particle migration in a liquid melt in high-gradient magnetic fields and we also describe their effects on the solidification microstructure of alloys.Diverse areas relevant to various aspects of theory and applications of high-gradient magnetic field-controlled migration of solutes and particles are surveyed.They include introduction,high-gradient magnetic field effects,migration behavior of solute and particles in high-gradient magnetic fields,microstructure evolution induced by high-gradient magnetic fieldcontrolled migrations of solute and particles,and properties of materials modified by high-gradient magnetic field-tailored microstructure.Selected examples of binary and multiphase alloy systems are presented and examined,with the main focus on the correlation between the high-gradient magnetic field-modified migration and the related solidification microstructure evolution.Particular attention is given to the mechanisms responsible for the microstructure evolution induced by highgradient magnetic fields.展开更多
Rice varieties Handao 2,Zhongbai 4,Han-jingzi,and Akihikari were treated with gradi-ent magnetic fileld to study the effect of gradi-ent field on rice.The magnetic field was madeup of 12 plots magnetic plates arranged...Rice varieties Handao 2,Zhongbai 4,Han-jingzi,and Akihikari were treated with gradi-ent magnetic fileld to study the effect of gradi-ent field on rice.The magnetic field was madeup of 12 plots magnetic plates arranged in eachother south and north pole.The magneticstrength was 0-40 mT.Each four varieties wasput under the magnetic plate 15 cm away,andwent through the magnetic field with the speedof 20 cm/s.The same varieties without thetreatment were used as CK.Both of the seedswere soaked in water for 48 h in room temper-ature,and then sprouted on the porcelain platewith absorbed water paper.When the展开更多
Since high magnetic field(MF) intensity can improve the image quality and reduce magnetic resonance imaging(MRI) acquisition time, the field intensity of MRIs has continued to increase over the past few decades. A...Since high magnetic field(MF) intensity can improve the image quality and reduce magnetic resonance imaging(MRI) acquisition time, the field intensity of MRIs has continued to increase over the past few decades. Although MRIs in most current hospitals are 0.5 T–3 T, there are preclinical studies have been carried out using 9.4 T MRI, and engineers are also putting efforts on building MRIs with even higher MFs. However, the accompanied safety issue of high-field MRIs is an emergent question to address before their clinical applications. In the meantime, the static magnetic field(SMF) has been shown to inhibit tumor growth in previous studies. Here, we investigated both the safety issue and the anti-tumor potentials of 3.7 T–24.5 T SMFs on GIST-T1 gastrointestinal stromal tumor-bearing nude mice. We followed up the mice three weeks after their exposure to high SMF and found that none of the mice died or had severe organ damage, except for slightly decreased food intake, weight gain, and liver function. Moreover, the tumor growth was inhibited by 3.7 T–24.5 T SMFs(up to ~54%). It is interesting that the effects are more dependent on MF gradient than intensities, and for the same gradient and intensity, mice responded differently to hypogravity and hypergravity conditions. Therefore, our study not only demonstrated the safeness of high SMFs up to 24.5 T on mice but also revealed their anti-tumor potentials in the future.展开更多
The section shape of an assembled magnetic medium is the most important structural parameter of a high gradient magnetic separator, which directly affects the induction distribution and magnetic field gradient of the ...The section shape of an assembled magnetic medium is the most important structural parameter of a high gradient magnetic separator, which directly affects the induction distribution and magnetic field gradient of the magnetic separator. In this study, equilateral triangle, square, hexagonal, octagon, dodecagon, and round shape sections of the assembled magnetic medium are chosen to study their influence on magnetic field distribution characteristics using the ANSYS analysis. This paper utilizes a single assembled magnetic medium to understand the relationship between the geometry of the assembled magnetic medium and its magnetic field distribution characteristics. The results show that high magnetic field,regional field, magnetic field gradient, and magnetic force formed by the different sections of the assembled magnetic medium in the same background magnetic field reduce in turn based on the triangle,square, hexagonal, octagon, dodecagon, and round. Based on the magnetic field characteristics analytic results, the magnetic separation tests of the ilmenite are carried out. The results indicate that the section shape of the toothed plate compared with the section shape of cylinder can improve the recovery of ilmenite up to 45% in the same magnetizing current condition of 2A, which is consistent with magnetic field characteristics analysis of different assembled magnetic medium section shapes.展开更多
In order to eliminate noise interference of metal magnetic memory signal in early diagnosis of stress concentration zones and metal defects, the empirical mode decomposition method combined with the magnetic field gra...In order to eliminate noise interference of metal magnetic memory signal in early diagnosis of stress concentration zones and metal defects, the empirical mode decomposition method combined with the magnetic field gradient characteristic was proposed. A compressive force periodically acting upon a casing pipe led to appreciable deformation, and magnetic signals were measured by a magnetic indicator TSC-1M-4. The raw magnetic memory signal was first decomposed into different intrinsic mode functions and a residue, and the magnetic field gradient distribution of the subsequent reconstructed signal was obtained. The experimental results show that the gradient around 350 mm represents the maximum value ignoring the marginal effect, and there is a good correlation between the real maximum field gradient and the stress concentration zone. The wavelet transform associated with envelop analysis also exhibits this gradient characteristic, indicating that the proposed method is effective for early identifying critical zones.展开更多
This paper presents a novel method that uses the interception effect of gradient magnetic field on oxygen molecules to realize enrichment.The use of two opposite magnetic poles of two magnets at a certain distance for...This paper presents a novel method that uses the interception effect of gradient magnetic field on oxygen molecules to realize enrichment.The use of two opposite magnetic poles of two magnets at a certain distance forms a magnetic space having a field intensity gradient near its borders.When air injected into the magnetic space outflows from the magnetic space via its borders,oxygen molecules in the air will experience the interception effect of the gradient magnetic field,but nitrogen molecules will outflow from the magnetic space without hindrance.Thus,continuous oxygen enrichment is realized.The enrichment degree of oxygen reaches 0.65%when the inlet and outlet air flows are 40 mL/min and 20 mL/min,respectively,and the gas temperature is 298 K and the maximal product of magnetic flux density and its gradient is 563 T2/m(the distance between two magnetic poles is 1 mm).When the gas temperature rises to 343 K,the enrichment degree drops to 0.32%;and when the maximal product of magnetic flux density and field intensity gradient drops to 101 T2/m(the distance between two magnetic poles is 4 mm),the enrichment degree drops to 0.23%.The experimental results show that there is an optimal ratio between the inlet air flow and the outlet air flow.Under the experimental conditions in this paper,the value is about 2.0.It is demonstrated that the method presented in this paper can continuously enrich oxygen and has a higher enrich-ment degree than other oxygen-enrichment methods using magnetic separation.展开更多
We study the ground-state phases of two-dimensional rotating spin-orbit coupled spin-1/2 Bose-Einstein condensates(BECs) in a gradient magnetic field. The competition between gradient magnetic field, spin-orbit coupli...We study the ground-state phases of two-dimensional rotating spin-orbit coupled spin-1/2 Bose-Einstein condensates(BECs) in a gradient magnetic field. The competition between gradient magnetic field, spin-orbit coupling and rotation leads to a variety of ground-state phase structures. In the weakly rotation regime, as the increase of gradient magnetic field strength, the BECs experiences a phase transition from the unstable phase to the single vortex-line phase. The unstable phase presents the vortex lines structures along the off-diagonal direction. With magnetic field gradient strength increasing, the number of vortex lines changes accordingly. As the magnetic field gradient strength increases further, the single vortex-line phase with a single vortex line along the diagonal direction is formed. The phase diagram shows that the boundary between the two phases is linear with the relative repulsion λ?≥?1 and is nonlinear with λ?展开更多
A novel oxygen-enriched method is presented. Using two opposite magnetic poles of two magnets with certain distance forms a magnetic space having a field intensity gradient near its borders. When air injected into the...A novel oxygen-enriched method is presented. Using two opposite magnetic poles of two magnets with certain distance forms a magnetic space having a field intensity gradient near its borders. When air injected into the magnetic space outflows from the magnetic space via its borders, oxygen molecules in air will experience the interception effect of the gradient magnetic field, but nitrogen molecules will outflow without hindrance. Thereby the continuous oxygen enrichment is realized. The results show that the maximum increment of oxygen concentration reaches 0.49% at 298 K when the maximum product of magnetic flux density and field intensity gradient is 563T^2/m. The enrichment level is significantly influenced by the gas temperature and the magnetic field. The maximum increment of oxygen concentration drops to 0.16% when the gas temperature rises to 343 K, and drops to 0.09% when the maximum product of magnetic flux density and gradient is reduced to 101 T^2/m from 563 T^2/m.展开更多
The liquid metal free surface innovation concept have been considered as liquid metal devices of divertor/limiter and tile of first wall in fusion device because it can withstand over 50 MW·m^2 heating load, is e...The liquid metal free surface innovation concept have been considered as liquid metal devices of divertor/limiter and tile of first wall in fusion device because it can withstand over 50 MW·m^2 heating load, is easily renewed by circulation and many overcome neutron irradiation damage life time limit. There are three types of free surface in the innovation concept as film, curtain (jets or drops) and capillary. The free surface jet is played a more attention at present. But it is no so clear and only a few available data that their magneto-hydrodynamics (MHD) instabilities, interaction with plasma and exclusion of the particles (ions, Alpha particles and so on) from liquid metal, in despite of many liquid metal free surface facilities built and operated especially in US in last two years. Recently, some primary results are carried out at LMEL facility at Southwestern Institute of Physics.展开更多
The design requirement and principle of the deflection magnet for Magnetron and Penning H^- ion source are discussed. It is proved that there exists a maximum emittance for the beam that may be transformed by the magn...The design requirement and principle of the deflection magnet for Magnetron and Penning H^- ion source are discussed. It is proved that there exists a maximum emittance for the beam that may be transformed by the magnet into a state with equal Twiss parameters of αr=αy and βr =βr=βy, which is the requisite condition to get a minimum emittance at the entrance of RFQ after transporting by a LEBT with solenoids. For this maximum emittance, the corresponding magnetic field gradient index is 1.展开更多
文摘The magnetic field profiles,which are produced by three ways in the deposition chamber and plasma chamber of single coil divergent field MWECR CVD system,are investigated.The magnetic field gradient of these magnetic field profiles is obtained quantitatively by using Lorentz fit.The results indicate that the gradient value of the magnetic field profile near by the substrate,which is produced by a coil current with 137.7A if a SmCo permanent magnet is equipped under the substrate holder,is the largest;when the SmCo permanent magnet is taken away,the larger one is produced by the coil current with 137.7A and the smallest one produced by a coil current with 115.2A.High deposition rate of a-Si∶H film is observed near by the substrate with high magnetic field gradient.But uneven deposition rate along the radius of the sample holder is also found by infrared analysis technology when sample is deposited in magnetic field profile,which is produced by the coil current with 137.7A if the SmCo permanent magnet is equipped under the substrate holder.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61227902,61374210,and 61121003)
文摘A method of measuring in-situ magnetic field gradient is proposed in this paper. The magnetic shield is widely used in the atomic magnetometer. However, there is magnetic field gradient in the magnetic shield, which would lead to additional gradient broadening. It is impossible to use an ex-situ magnetometer to measure magnetic field gradient in the region of a cell, whose length of side is several centimeters. The method demonstrated in this paper can realize the in-situ measurement of the magnetic field gradient inside the cell, which is significant for the spin relaxation study. The magnetic field gradients along the longitudinal axis of the magnetic shield are measured by a spin-exchange relaxation-free (SERF) magnetometer by adding a magnetic field modulation in the probe beam's direction. The transmissivity of the cell for the probe beam is always inhomogeneous along the pump beam direction, and the method proposed in this paper is independent of the intensity of the probe beam, which means that the method is independent of the cell's transmissivity. This feature makes the method more practical experimentally. Moreover, the AC-Stark shift can seriously degrade and affect the precision of the magnetic field gradient measurement. The AC-Stark shift is suppressed by locking the pump beam to the resonance of potassium's D1 line. Furthermore, the residual magnetic fields are measured with σ+- and σ--polarized pump beams, which can further suppress the effect of the AC-Stark shift. The method of measuring in-situ magnetic field gradient has achieved a magnetic field gradient precision of better than 30 pT/mm.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11625417,11727809,11474115,91636219,and 91636221)the Post-doctoral Science Foundation of China(Grant No.2017M620308)
文摘The effect of the Raman-pulse duration related to the magnetic field gradient, as a systematic error, is playing an important role on evaluating the performance of high-precision atomic gravimeters. We study this effect with a simplified theoretical model of the time-propagation operator. According to the typical parameters, we find that this effect should be taken into account when the gravimeter reaches an accuracy of 10^-10g, and the larger the pulse duration is, the more obvious the systematic effect will be. Finally, we make a simple discussion on the possibility of testing this effect.
基金supported by the National Natural Science Foundation of China (U21A20148, 31900506, 52007185)International Partnership Program of the Chinese Academy of Sciences(116134KYSB20210052)+2 种基金Heye Health Technology Chong Ming Project(HYCMP2021010)CAS President’s International Fellowship Initiative Grant(2022VMA0009)CASHIPS Director’s Fund (BJPY2021A06,2021YZGH04, YZJJ2020QN26, YZJJZX202014, YZJJ2021QN32,YZJJ2023QN43)。
文摘Although 9.4 T magnetic resonance imaging(MRI) has been tested in healthy volunteers,its safety in diabetic patients is unclear.Furthermore,the effects of high static magnetic fields(SMFs),especially gradient vs.uniform fields,have not been investigated in diabetics.Here,we investigated the consequences of exposure to 1.0-9.4 T high SMFs of different gradients(>10 T/m vs.0-10 T/m)on type 1 diabetic(T1D) and type 2 diabetic(T2D) mice.We found that 14 h of prolonged treatment of gradient(as high as 55.5 T/m) high SMFs(1.0-8.6 T) had negative effects on T1D and T2D mice,including spleen,hepatic,and renal tissue impairment and elevated glycosylated serum protein,blood glucose,inflammation,and anxiety,while 9.4 T quasi-uniform SMFs at 0-10 T/m did not induce the same effects.In regular T1D mice(blood glucose>16.7 mmol/L),the>10 T/m gradient high SMFs increased malondialdehyde(P<0.01) and decreased superoxide dismutase(P<0.05).However,in the severe T1D mice(blood glucose≥30.0 mmol/L),the>10 T/m gradient high SMFs significantly increased tissue damage and reduced survival rate.In vitro cellular studies showed that gradient high SMFs increased cellular reactive oxygen species and apoptosis and reduced MS-1 cell number and proliferation.Therefore,this study showed that prolonged exposure to high-field(1.0-8.6 T)>10 T/m gradient SMFs(35-1 380 times higher than that of current clinical MRI)can have negative effects on diabetic mice,especially mice with severe T1D,whereas 9.4 T high SMFs at 0-10T/m did not produce the same effects,providing important information for the future development and clinical application of SMFs,especially high-field MRI.
基金supported by the National Natural Science Foundation of China(Grant Nos.61435007,11175094,91221205)the National Basic Research Program of China(Grant No.2015CB921002)
文摘We consider a cantilever mechanical oscillator(MO) made of diamond. A nitrogen-vacancy(NV) center lies at the end of the cantilever. Two magnetic tips near the NV center induce a strong second-order magnetic field gradient. Under coherent driving of the MO, we find that the coupling between the MO and the NV center is greatly enhanced. We studied how to generate entanglement between the MO and the NV center and realize quantum state transfer between them. We also propose a scheme to generate two-mode squeezing between different MO modes by coupling them to the same NV center. The decoherence and dissipation effects for both the MO and the NV center are numerically calculated using the present parameter values of the experimental configuration. We have achieved high fidelity for entanglement generation, quantum state transfer, and large twomode squeezing.
基金Item Sponsored by the National Natural Science Foundation of China (Grant Nos.51006020 and 51174056) the Fundamental Research Funds for the Central Universities (Grant Nos.N090109001+3 种基金N100409008and N100609001) the National Basic Research Program of China (Grant Nos.2011CB612206 and 2011CB610405) the Wuhan National High Magnetic Field Center (Grant No.WHMFCK2011006)
文摘In this study,the effects of high magnetic field gradients on the segregation of alloying elements,crystallized phases,and particles in alloys during solidification process and corresponding microstructures were discussed.It was confirmed that applying an external high magnetic field gradient during solidification process is an effective processing route for controlling segregation in alloys and then fabricating functional materials which have special mierostruetures and properties.Such controlling and fabrication were realized by controlling the migration of the alloying elements, crystallized phases,and particles in the liquid matrix on the basis of the Lorentz and magnetic forces.
基金Supported by the National Natural Science Foundation of China under Grant Nos.11374032,61435007,and 11704026the Joint Fund of the Ministry of Education of China under Grant No.6141A02011604+1 种基金NSAF(China)under Grant No.U1530401National Key Research and Development Program of China under Grant No.2016YFA0301201
文摘Optically levitated nano-particle with spins is a promising system for high-precision measurement and quantum information processing. We theoretically analyze the ratio between the fluctuation of particle's displacement caused by spins in magnetic field and caused by molecular collisions of the residual air. When the ratio is larger than unity, the displacement fluctuation of spins flipping can be remarkably detected. By theoretical analysis and numerical simulation, we propose and validate a scheme for the detection of gradient of the magnetic field by levitating ferromagnetic nano-particle, and also put forward a realizable detection scheme of the single spin by levitating nano-diamond particle with single nitrogen-vacancy(NV) centers.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.51425401,51690161,51574073,and 51774086)Fundamental Research Funds for the Central Universities,China(Grant Nos.N170902002 and N170908001)Liaoning Innovative Research Team in University,China(Grant No.LT2017011)
文摘We present a review of the principal developments in the evolution and synergism of solute and particle migration in a liquid melt in high-gradient magnetic fields and we also describe their effects on the solidification microstructure of alloys.Diverse areas relevant to various aspects of theory and applications of high-gradient magnetic field-controlled migration of solutes and particles are surveyed.They include introduction,high-gradient magnetic field effects,migration behavior of solute and particles in high-gradient magnetic fields,microstructure evolution induced by high-gradient magnetic fieldcontrolled migrations of solute and particles,and properties of materials modified by high-gradient magnetic field-tailored microstructure.Selected examples of binary and multiphase alloy systems are presented and examined,with the main focus on the correlation between the high-gradient magnetic field-modified migration and the related solidification microstructure evolution.Particular attention is given to the mechanisms responsible for the microstructure evolution induced by highgradient magnetic fields.
文摘Rice varieties Handao 2,Zhongbai 4,Han-jingzi,and Akihikari were treated with gradi-ent magnetic fileld to study the effect of gradi-ent field on rice.The magnetic field was madeup of 12 plots magnetic plates arranged in eachother south and north pole.The magneticstrength was 0-40 mT.Each four varieties wasput under the magnetic plate 15 cm away,andwent through the magnetic field with the speedof 20 cm/s.The same varieties without thetreatment were used as CK.Both of the seedswere soaked in water for 48 h in room temper-ature,and then sprouted on the porcelain platewith absorbed water paper.When the
基金Project supported by the National Key R&D Program of China(Grant Nos.2016YFA0400900 and 2017YFA0402903)the National Natural Science Foundation of China(Grant Nos.U1532151 and 51627901)+2 种基金the Major/Innovative Program of Development Foundation of Hefei Center for Physical Science,Technology(Grant No.2016FXCX004)Hefei Science Center,CAS(Grant No.2016HSC-IU007)the CASHIPS Director’s Fund(Grant No.YZJJ201704)to Qingyou Lu and Xin Zhang
文摘Since high magnetic field(MF) intensity can improve the image quality and reduce magnetic resonance imaging(MRI) acquisition time, the field intensity of MRIs has continued to increase over the past few decades. Although MRIs in most current hospitals are 0.5 T–3 T, there are preclinical studies have been carried out using 9.4 T MRI, and engineers are also putting efforts on building MRIs with even higher MFs. However, the accompanied safety issue of high-field MRIs is an emergent question to address before their clinical applications. In the meantime, the static magnetic field(SMF) has been shown to inhibit tumor growth in previous studies. Here, we investigated both the safety issue and the anti-tumor potentials of 3.7 T–24.5 T SMFs on GIST-T1 gastrointestinal stromal tumor-bearing nude mice. We followed up the mice three weeks after their exposure to high SMF and found that none of the mice died or had severe organ damage, except for slightly decreased food intake, weight gain, and liver function. Moreover, the tumor growth was inhibited by 3.7 T–24.5 T SMFs(up to ~54%). It is interesting that the effects are more dependent on MF gradient than intensities, and for the same gradient and intensity, mice responded differently to hypogravity and hypergravity conditions. Therefore, our study not only demonstrated the safeness of high SMFs up to 24.5 T on mice but also revealed their anti-tumor potentials in the future.
基金provided by the Postdoctoral Science Foundation of China(No.2013M542076)the self-determined and innovative research funds of WUT(No.2014-IV-069)the Ministry of Science and Technology of China(No.2011BAB05B01)
文摘The section shape of an assembled magnetic medium is the most important structural parameter of a high gradient magnetic separator, which directly affects the induction distribution and magnetic field gradient of the magnetic separator. In this study, equilateral triangle, square, hexagonal, octagon, dodecagon, and round shape sections of the assembled magnetic medium are chosen to study their influence on magnetic field distribution characteristics using the ANSYS analysis. This paper utilizes a single assembled magnetic medium to understand the relationship between the geometry of the assembled magnetic medium and its magnetic field distribution characteristics. The results show that high magnetic field,regional field, magnetic field gradient, and magnetic force formed by the different sections of the assembled magnetic medium in the same background magnetic field reduce in turn based on the triangle,square, hexagonal, octagon, dodecagon, and round. Based on the magnetic field characteristics analytic results, the magnetic separation tests of the ilmenite are carried out. The results indicate that the section shape of the toothed plate compared with the section shape of cylinder can improve the recovery of ilmenite up to 45% in the same magnetizing current condition of 2A, which is consistent with magnetic field characteristics analysis of different assembled magnetic medium section shapes.
基金Project(10772061) supported by the National Natural Science Foundation of ChinaProject(A200907) supported by the Natural Science Foundation of Heilongjiang Province, China Project(20092322120001) supported by the PhD Programs Foundations of Ministry of Education of China
文摘In order to eliminate noise interference of metal magnetic memory signal in early diagnosis of stress concentration zones and metal defects, the empirical mode decomposition method combined with the magnetic field gradient characteristic was proposed. A compressive force periodically acting upon a casing pipe led to appreciable deformation, and magnetic signals were measured by a magnetic indicator TSC-1M-4. The raw magnetic memory signal was first decomposed into different intrinsic mode functions and a residue, and the magnetic field gradient distribution of the subsequent reconstructed signal was obtained. The experimental results show that the gradient around 350 mm represents the maximum value ignoring the marginal effect, and there is a good correlation between the real maximum field gradient and the stress concentration zone. The wavelet transform associated with envelop analysis also exhibits this gradient characteristic, indicating that the proposed method is effective for early identifying critical zones.
基金supported by the Key Project of Beijing Municipal Committee of Education(Grant No.00020)the Foundation Project of University of Science and Technology Beijing(Grant No.20040600290),China.
文摘This paper presents a novel method that uses the interception effect of gradient magnetic field on oxygen molecules to realize enrichment.The use of two opposite magnetic poles of two magnets at a certain distance forms a magnetic space having a field intensity gradient near its borders.When air injected into the magnetic space outflows from the magnetic space via its borders,oxygen molecules in the air will experience the interception effect of the gradient magnetic field,but nitrogen molecules will outflow from the magnetic space without hindrance.Thus,continuous oxygen enrichment is realized.The enrichment degree of oxygen reaches 0.65%when the inlet and outlet air flows are 40 mL/min and 20 mL/min,respectively,and the gas temperature is 298 K and the maximal product of magnetic flux density and its gradient is 563 T2/m(the distance between two magnetic poles is 1 mm).When the gas temperature rises to 343 K,the enrichment degree drops to 0.32%;and when the maximal product of magnetic flux density and field intensity gradient drops to 101 T2/m(the distance between two magnetic poles is 4 mm),the enrichment degree drops to 0.23%.The experimental results show that there is an optimal ratio between the inlet air flow and the outlet air flow.Under the experimental conditions in this paper,the value is about 2.0.It is demonstrated that the method presented in this paper can continuously enrich oxygen and has a higher enrich-ment degree than other oxygen-enrichment methods using magnetic separation.
基金supported by the NSF of China under Grant No11 904 242the NSF of Hebei province under Grant No A2019210280。
文摘We study the ground-state phases of two-dimensional rotating spin-orbit coupled spin-1/2 Bose-Einstein condensates(BECs) in a gradient magnetic field. The competition between gradient magnetic field, spin-orbit coupling and rotation leads to a variety of ground-state phase structures. In the weakly rotation regime, as the increase of gradient magnetic field strength, the BECs experiences a phase transition from the unstable phase to the single vortex-line phase. The unstable phase presents the vortex lines structures along the off-diagonal direction. With magnetic field gradient strength increasing, the number of vortex lines changes accordingly. As the magnetic field gradient strength increases further, the single vortex-line phase with a single vortex line along the diagonal direction is formed. The phase diagram shows that the boundary between the two phases is linear with the relative repulsion λ?≥?1 and is nonlinear with λ?
文摘A novel oxygen-enriched method is presented. Using two opposite magnetic poles of two magnets with certain distance forms a magnetic space having a field intensity gradient near its borders. When air injected into the magnetic space outflows from the magnetic space via its borders, oxygen molecules in air will experience the interception effect of the gradient magnetic field, but nitrogen molecules will outflow without hindrance. Thereby the continuous oxygen enrichment is realized. The results show that the maximum increment of oxygen concentration reaches 0.49% at 298 K when the maximum product of magnetic flux density and field intensity gradient is 563T^2/m. The enrichment level is significantly influenced by the gas temperature and the magnetic field. The maximum increment of oxygen concentration drops to 0.16% when the gas temperature rises to 343 K, and drops to 0.09% when the maximum product of magnetic flux density and gradient is reduced to 101 T^2/m from 563 T^2/m.
文摘The liquid metal free surface innovation concept have been considered as liquid metal devices of divertor/limiter and tile of first wall in fusion device because it can withstand over 50 MW·m^2 heating load, is easily renewed by circulation and many overcome neutron irradiation damage life time limit. There are three types of free surface in the innovation concept as film, curtain (jets or drops) and capillary. The free surface jet is played a more attention at present. But it is no so clear and only a few available data that their magneto-hydrodynamics (MHD) instabilities, interaction with plasma and exclusion of the particles (ions, Alpha particles and so on) from liquid metal, in despite of many liquid metal free surface facilities built and operated especially in US in last two years. Recently, some primary results are carried out at LMEL facility at Southwestern Institute of Physics.
文摘The design requirement and principle of the deflection magnet for Magnetron and Penning H^- ion source are discussed. It is proved that there exists a maximum emittance for the beam that may be transformed by the magnet into a state with equal Twiss parameters of αr=αy and βr =βr=βy, which is the requisite condition to get a minimum emittance at the entrance of RFQ after transporting by a LEBT with solenoids. For this maximum emittance, the corresponding magnetic field gradient index is 1.