The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1....The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.669 m/s while the flow velocity distribution is not uniform for each cylinder.Moreover,the fluid velocity in proximity to the cylinder head is too low,thereby affecting the cooling performances of the water jacket.Two corresponding structural optimization schemes are proposed to mitigate this issue and the post-optimization performances of the water jacket are discussed in detail.展开更多
The electrohydrodynamics (EHD) enhancement of convection heat transfer of water in a jacket tube heat exchanger was studied through an experimental method in this paper. In the experiment,a DC high voltage electrode...The electrohydrodynamics (EHD) enhancement of convection heat transfer of water in a jacket tube heat exchanger was studied through an experimental method in this paper. In the experiment,a DC high voltage electrode was set in the central tube-side of the heat exchanger,and the high voltage electrode in the tube-side was adjustable in the range of 0-40 kV. Five differ-ent combinations of heat transfer enhancement experiments were conducted under the different voltage and rate of flow. The results indicate that the maximal enhancement coefficient θ is 1.224 when the flow rate of tube-side inlet is 0.1 m3/h. It is proved that,for the work medium of water,the convective heat transfer can be enhanced by applying high electric field. The performance of EHD-enhanced is sensitive to the variation of flow rate,and in the same flow rate,there exist an optimized voltage in the EHD-enhanced process ra-ther than the monotonic positive-correlation relationship.展开更多
文摘The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.669 m/s while the flow velocity distribution is not uniform for each cylinder.Moreover,the fluid velocity in proximity to the cylinder head is too low,thereby affecting the cooling performances of the water jacket.Two corresponding structural optimization schemes are proposed to mitigate this issue and the post-optimization performances of the water jacket are discussed in detail.
基金Supported by the National Natural Science Foundation of China (51006076, 50906065)the Program for Excellent Young and Mid-dle-Aged Researchers in Hubei Province (Q20081508)
文摘The electrohydrodynamics (EHD) enhancement of convection heat transfer of water in a jacket tube heat exchanger was studied through an experimental method in this paper. In the experiment,a DC high voltage electrode was set in the central tube-side of the heat exchanger,and the high voltage electrode in the tube-side was adjustable in the range of 0-40 kV. Five differ-ent combinations of heat transfer enhancement experiments were conducted under the different voltage and rate of flow. The results indicate that the maximal enhancement coefficient θ is 1.224 when the flow rate of tube-side inlet is 0.1 m3/h. It is proved that,for the work medium of water,the convective heat transfer can be enhanced by applying high electric field. The performance of EHD-enhanced is sensitive to the variation of flow rate,and in the same flow rate,there exist an optimized voltage in the EHD-enhanced process ra-ther than the monotonic positive-correlation relationship.