期刊文献+
共找到30,633篇文章
< 1 2 250 >
每页显示 20 50 100
A Rapid Adaptation Approach for Dynamic Air‑Writing Recognition Using Wearable Wristbands with Self‑Supervised Contrastive Learning
1
作者 Yunjian Guo Kunpeng Li +4 位作者 Wei Yue Nam‑Young Kim Yang Li Guozhen Shen Jong‑Chul Lee 《Nano-Micro Letters》 SCIE EI CAS 2025年第2期417-431,共15页
Wearable wristband systems leverage deep learning to revolutionize hand gesture recognition in daily activities.Unlike existing approaches that often focus on static gestures and require extensive labeled data,the pro... Wearable wristband systems leverage deep learning to revolutionize hand gesture recognition in daily activities.Unlike existing approaches that often focus on static gestures and require extensive labeled data,the proposed wearable wristband with selfsupervised contrastive learning excels at dynamic motion tracking and adapts rapidly across multiple scenarios.It features a four-channel sensing array composed of an ionic hydrogel with hierarchical microcone structures and ultrathin flexible electrodes,resulting in high-sensitivity capacitance output.Through wireless transmission from a Wi-Fi module,the proposed algorithm learns latent features from the unlabeled signals of random wrist movements.Remarkably,only few-shot labeled data are sufficient for fine-tuning the model,enabling rapid adaptation to various tasks.The system achieves a high accuracy of 94.9%in different scenarios,including the prediction of eight-direction commands,and air-writing of all numbers and letters.The proposed method facilitates smooth transitions between multiple tasks without the need for modifying the structure or undergoing extensive task-specific training.Its utility has been further extended to enhance human–machine interaction over digital platforms,such as game controls,calculators,and three-language login systems,offering users a natural and intuitive way of communication. 展开更多
关键词 Wearable wristband Self-supervised contrastive learning Dynamic gesture Air-writing Human-machine interaction
下载PDF
FedCLCC:A personalized federated learning algorithm for edge cloud collaboration based on contrastive learning and conditional computing
2
作者 Kangning Yin Xinhui Ji +1 位作者 Yan Wang Zhiguo Wang 《Defence Technology(防务技术)》 2025年第1期80-93,共14页
Federated learning(FL)is a distributed machine learning paradigm for edge cloud computing.FL can facilitate data-driven decision-making in tactical scenarios,effectively addressing both data volume and infrastructure ... Federated learning(FL)is a distributed machine learning paradigm for edge cloud computing.FL can facilitate data-driven decision-making in tactical scenarios,effectively addressing both data volume and infrastructure challenges in edge environments.However,the diversity of clients in edge cloud computing presents significant challenges for FL.Personalized federated learning(pFL)received considerable attention in recent years.One example of pFL involves exploiting the global and local information in the local model.Current pFL algorithms experience limitations such as slow convergence speed,catastrophic forgetting,and poor performance in complex tasks,which still have significant shortcomings compared to the centralized learning.To achieve high pFL performance,we propose FedCLCC:Federated Contrastive Learning and Conditional Computing.The core of FedCLCC is the use of contrastive learning and conditional computing.Contrastive learning determines the feature representation similarity to adjust the local model.Conditional computing separates the global and local information and feeds it to their corresponding heads for global and local handling.Our comprehensive experiments demonstrate that FedCLCC outperforms other state-of-the-art FL algorithms. 展开更多
关键词 Federated learning Statistical heterogeneity Personalized model Conditional computing contrastive learning
下载PDF
Low-concentration atropine(0.01%)on quantitative contrast sensitivity function in Chinese children with myopia
3
作者 Yu-Hao Ye Yi-Yong Xian +3 位作者 Fang Liu Zhong-Lin Lyu Xing-Tao Zhou Jing Zhao 《International Journal of Ophthalmology(English edition)》 2025年第1期117-124,共8页
AIM:To investigate the effect of 0.01%low-concentration atropine(LA)on quantitative contrast sensitivity function(qCSF)in children with myopia.METHODS:This paired case-control study included 90 eyes of 58 children who... AIM:To investigate the effect of 0.01%low-concentration atropine(LA)on quantitative contrast sensitivity function(qCSF)in children with myopia.METHODS:This paired case-control study included 90 eyes of 58 children who were sex-,age-,and refractionmatched and equally divided into two groups:the 0.01%LA group had undergone 6mo use of daily 0.01%atropine and control group was naïve to LA.Routine ophthalmic examinations and qCSF test without refractive correction were performed.Two groups were compared in monocular and binocular qCSF parameters,including the area under logCSF,CSF acuity,and contrast sensitivity(CS)at 1.0-18.0 cycle per degree(cpd).RESULTS:In the monocular comparison,the CSF acuity of the LA group was significantly higher than that of the control group(7.58±5.51 vs 6.37±4.22 cpd,P<0.05).The subgroup analysis showed that in the 6-9y group,CSF acuity was significantly higher in the LA group than the control group(8.76±6.19 vs 6.54±4.25 cpd,P<0.05),and in the Female group,low refraction sphere group,and high refraction cylinder group,the CS at high spatial frequencies(12.0 and 18.0 cpd)were significantly higher in the LA group than in the control group(all P<0.05).In the binocular test,CSF acuity and CS at 12.0 cpd were significantly higher in the LA group than in the control group(10.95±7.00 vs 8.65±5.12 cpd;0.17±0.33 vs 0.06±0.16,respectively;both P<0.05).CONCLUSION:Use of LA may result in improved CS in children with early onset myopia. 展开更多
关键词 low-concentration atropine MYOPIA quantitative contrast sensitivity function Chinese children
下载PDF
Innovative approaches beyond periprocedural hydration for preventing contrast-induced acute kidney injury
4
作者 Chun-Han Cheng Wen-Rui Hao Tzu-Hurng Cheng 《World Journal of Radiology》 2024年第9期375-379,共5页
Contrast-induced acute kidney injury(CI-AKI)is a major concern in clinical practice,particularly among high-risk patients with preexisting renal and cardiovascular conditions.Although periprocedural hydration has long... Contrast-induced acute kidney injury(CI-AKI)is a major concern in clinical practice,particularly among high-risk patients with preexisting renal and cardiovascular conditions.Although periprocedural hydration has long been the primary approach for CI-AKI prevention,recent advancements have led to the development of novel approaches such as RenalGuard and contrast removal systems.This editorial explores these emerging approaches and highlights their potential for enhancing CI-AKI prevention.By incorporating the latest evidence into clinical practice,health-care professionals can more effectively maintain renal function and improve outcomes for patients undergoing contrast-enhanced procedures. 展开更多
关键词 contrast-induced acute kidney injury contrast-induced acute kidney injury prevention Periprocedural hydration RenalGuard contrast removal systems
下载PDF
Navigating nephrotoxic waters:A comprehensive overview of contrast-induced acute kidney injury prevention 被引量:1
5
作者 Panagiotis Theofilis Rigas Kalaitzidis 《World Journal of Radiology》 2024年第6期168-183,共16页
Contrast-induced acute kidney injury(CI-AKI)is the third leading cause of acute kidney injury deriving from the intravascular administration of contrast media in diagnostic and therapeutic procedures and leading to lo... Contrast-induced acute kidney injury(CI-AKI)is the third leading cause of acute kidney injury deriving from the intravascular administration of contrast media in diagnostic and therapeutic procedures and leading to longer in-hospital stay and increased short and long-term mortality.Its pathophysiology,although not well-established,revolves around medullary hypoxia paired with the direct toxicity of the substance to the kidney.Critically ill patients,as well as those with pre-existing renal disease and cardiovascular comorbidities,are more susceptible to CI-AKI.Despite the continuous research in the field of CI-AKI prevention,clinical practice is based mostly on periprocedural hydration.In this review,all the investigated methods of prevention are presented,with an emphasis on the latest evidence regarding the potential of RenalGuard and contrast removal systems for CI-AKI prevention in high-risk individuals. 展开更多
关键词 contrast-induced acute kidney injury contrast media PREVENTION HYDRATION RenalGuard Dyevert
下载PDF
Gastrointestinal contrast-enhanced ultrasonography for diagnosis and treatment of peptic ulcer in children
6
作者 Yu-Hua Zhang Zhi-Hua Xu +1 位作者 Shuang-Shuang Ni Hong-Xia Luo 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期705-713,共9页
BACKGROUND The detection rate of peptic ulcer in children is improving,with development of diagnostic procedures.Gastroscopy is the gold standard for the diagnosis of peptic ulcer,but it is an invasive procedure.Gastr... BACKGROUND The detection rate of peptic ulcer in children is improving,with development of diagnostic procedures.Gastroscopy is the gold standard for the diagnosis of peptic ulcer,but it is an invasive procedure.Gastrointestinal contrast-enhanced ultrasonography(CEUS)has the advantages of being painless,noninvasive,nonradioactive,easy to use,and safe.AIM To investigate the clinical value of CEUS for diagnosis and treatment of peptic ulcer in children.METHODS We investigated 43 children with digestive tract symptoms in our hospital from January 2021 to June 2022.All children were examined by routine ultrasound,gastrointestinal CEUS,and gastroscopy.The pathological results of gastroscopy were taken as the gold standard.Routine ultrasonography was performed before gastrointestinal CEUS.Conventional ultrasound showed the thickness of the gastroduodenal wall,gastric peristalsis,and the adjacent organs and tissues around the abdominal cavity.Gastrointestinal CEUS recorded the thickness of the gastroduodenal wall;the size,location and shape of the ulcer;gastric peristalsis;and adjacent organs and tissues around the abdominal cavity.The results of routine ultrasound and gastrointestinal ultrasound were compared with those of gastroscopy to evaluate the diagnostic results and coincidence rate of routine ultrasound and gastrointestinal CEUS.All children received informed consent from their guardians for CEUS.This study was reviewed and approved by the hospital medical ethics committee.RESULTS Among the 43 children,17(15 male,2 female)were diagnosed with peptic ulcer by gastroscopy.There were 26 children with nonpeptic ulcer.There were eight cases of peptic ulcer and 35 of nonpeptic ulcer diagnosed by conventional ultrasound.The diagnostic coincidence rate of peptic ulcer in children diagnosed by conventional ultrasound was 79.1%(34/43),which was significantly different from that of gastroscopy(P=0.033).It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is low.Fifteen cases of peptic ulcer and 28 of nonpeptic ulcer were diagnosed by CEUS.The diagnostic coincidence rate of peptic ulcer in children was 95.3%(41/43).There was no significant difference between CEUS and gastroscopy(P=0.655).It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is high.CONCLUSION Gastrointestinal CEUS has a high coincidence rate in the diagnosis of peptic ulcer in children,and can be used as a preliminary examination method. 展开更多
关键词 contrast-enhanced ultrasound Peptic ulcer CHILDREN Gastrointestinal tract Abdominal pain Acoustic contrast agent
下载PDF
Right-to-left shunt detection via synchronized contrast transcranial Doppler combined with contrast transthoracic echocardiography:A preliminary study
7
作者 Man-Juan Yao Ying-Ying Zhao +4 位作者 Shui-Ping Deng Hua-Hua Xiong Jing Wang Li-Jie Ren Li-Ming Cao 《World Journal of Radiology》 2024年第11期657-667,共11页
BACKGROUND Patent foramen ovale(PFO)-related right-to-left shunts(RLSs)have been impli-cated in cryptogenic stroke and migraine,with larger shunts posing a higher risk.When used individually to detect RLS,contrast tra... BACKGROUND Patent foramen ovale(PFO)-related right-to-left shunts(RLSs)have been impli-cated in cryptogenic stroke and migraine,with larger shunts posing a higher risk.When used individually to detect RLS,contrast transcranial Doppler(cTCD)and contrast transthoracic echocardiography(cTTE)may yield false-negative results.Further,the literature exposes gaps regarding the understanding of the limitations of cTCD and cTTE,presents conflicting recommendations on their exclusive use,and highlights inefficiencies associated with nonsynchronous testing.AIM To investigate the accuracy of multimodal ultrasound to improve diagnostic efficiency in detecting PFO-related RLSs.METHODS We prospectively enrolled four patients with cryptogenic stroke(n=1),migraine(n=2),and unexplained dizziness(n=1)who underwent synchronized cTCD combined with cTTE.The participants were monitored and followed-up for 24 months.RESULTS cTTE identified moderate and large RLSs in patients with recurrent cryptogenic stroke and migraines,whereas cTCD revealed only small RLSs.Moderate and large RLS were confirmed on combined cTTE and cTCD.After excluding other causes,both patients underwent PFO occlusion.At 21-and 24-month follow-up examinations,neither stroke nor migraine had recurred.cTTE revealed a small RLS in a third patient with unexplained dizziness and a fourth patient with migraines;however,simultaneous cTCD detected a large RLS.These patients did not undergo interventional occlusion,and dizziness and headache recurred at the 17-and 24-month follow-up examin-ations.CONCLUSION Using cTTE or cTCD may underestimate RLS,impairing risk assessments.Combining synchronized cTCD with cTTE could enhance testing accuracy and support better diagnostic and therapeutic decisions. 展开更多
关键词 contrast transcranial Doppler contrast transthoracic echocardiography Cryptogenic stroke Multimodal ultrasonography Patent foramen ovale Right-to-left shunt
下载PDF
Accuracy and Utility of Vessel Analysis Using Non-Contrast CT for Planning Endovascular Aortic Repair
8
作者 Midori Komita-Moriya Yukihisa Ogawa +6 位作者 Akiyuki Kotoku Shintaro Nawata Kenji Kuramochi Yasuyoshi Ogawa Kiyoshi Chiba Hiroshi Nishimaki Hidefumi Mimura 《Open Journal of Medical Imaging》 2024年第3期96-105,共10页
Objectives: This study aimed to determine whether errors in vascular measurements would affect device selection in endovascular aortic repair (EVAR) by comparing measurements obtained using non-contrast computed tomog... Objectives: This study aimed to determine whether errors in vascular measurements would affect device selection in endovascular aortic repair (EVAR) by comparing measurements obtained using non-contrast computed tomography (NCT) with those obtained using contrast-enhanced CT (CECT). Materials and Methods: This single-center, retrospective study included 25 patients who underwent EVAR for abdominal aortic aneurysm at our institution. A 1-mm horizontal cross-sectional slice of NCT and CECT from each patient was retrospectively reviewed. The area from the abdominal aorta to the common iliac artery was divided into four zones. A centerline was created using the NCT by manually plotting the center points. Subsequently, the centerlines were automatically extracted and manually corrected during the arterial phase of CECT. The diameter and length of each zone were measured for each modality. The mean diameters and lengths of the target vessels were compared between NCT and CECT. Results: The measurements obtained using both methods were reproducible and demonstrated good agreement. The mean differences in vessel length and diameter measurements for each segment between NCT and CECT were not statistically significant, indicating good consistency. Conclusion: NCT may be useful for preoperative EVAR evaluation in patients with renal dysfunction or allergies to contrast agents. 展开更多
关键词 Non-contrast CT Vessel Analysis EVAR contrast-Enhanced CT Abdominal Aortic Aneurysm
下载PDF
Attribution of Biases of Interhemispheric Temperature Contrast in CMIP6 Models 被引量:1
9
作者 Shiyan ZHANG Yongyun HU +1 位作者 Jiankai ZHANG Yan XIA 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第2期325-340,共16页
One of the basic characteristics of Earth's modern climate is that the Northern Hemisphere(NH) is climatologically warmer than the Southern Hemisphere(SH). Here, model performances of this basic state are examined... One of the basic characteristics of Earth's modern climate is that the Northern Hemisphere(NH) is climatologically warmer than the Southern Hemisphere(SH). Here, model performances of this basic state are examined using simulation results from 26 CMIP6 models. Results show that the CMIP6 models underestimate the contrast in interhemispheric surface temperatures on average(0.8 K for CMIP6 mean versus 1.4 K for reanalysis data mean), and that there is a large intermodel spread, ranging from -0.7 K to 2.3 K. A box model energy budget analysis shows that the contrast in interhemispheric shortwave absorption at the top of the atmosphere, the contrast in interhemispheric greenhouse trapping, and the crossequatorial northward ocean heat transport, are all underestimated in the multimodel mean. By examining the intermodel spread, we find intermodel biases can be tracked back to biases in midlatitude shortwave cloud forcing in AGCMs. Models with a weaker interhemispheric temperature contrast underestimate the shortwave cloud reflection in the SH but overestimate the shortwave cloud reflection in the NH, which are respectively due to underestimation of the cloud fraction over the SH extratropical ocean and overestimation of the cloud liquid water content over the NH extratropical continents.Models that underestimate the interhemispheric temperature contrast exhibit larger double ITCZ biases, characterized by excessive precipitation in the SH tropics. Although this intermodel spread does not account for the multimodel ensemble mean biases, it highlights that improving cloud simulation in AGCMs is essential for simulating the climate realistically in coupled models. 展开更多
关键词 interhemispheric temperature contrast energy balance shortwave cloud forcing ITCZ CMIP6 AGCM
下载PDF
Computed tomography pulmonary angiography using a 20% reduction in contrast medium dose delivered in a multiphasic injection 被引量:3
10
作者 Mitchell Chen Gaith Mattar Jamal A Abdulkarim 《World Journal of Radiology》 CAS 2017年第3期143-147,共5页
AIM To evaluate the feasibility of reducing the dose of iodinated contrast agent in computed tomography pulmonary angiography(CTPA). METHODS One hundred and twenty-seven patients clinically suspected of having pulmona... AIM To evaluate the feasibility of reducing the dose of iodinated contrast agent in computed tomography pulmonary angiography(CTPA). METHODS One hundred and twenty-seven patients clinically suspected of having pulmonary embolism underwent spiral CTPA, out of whom fifty-seven received 75 mL and the remaining seventy a lower dose of 60 mL of contrast agent. Both doses were administered in a multiphasic injection. A minimum opacification threshold of 250 Hounsfield units(HU) in the main pulmonary artery is used for assessing the technical adequacy of the scans. RESULTS Mean opacification was found to be positively correlated to patient age(Pearson's correlation 0.4255, P < 0.0001) and independent of gender(male:female, 425.6 vs 450.4,P = 0.34). When age is accounted for, the study and control groups did not differ significantly in their mean opacification in the main(436.8 vs 437.9, P = 0.48),left(416.6 vs 419.8, P = 0.45) or the right pulmonary arteries(417.3 vs 423.5, P = 0.40). The number of sub-optimally opacified scans(the mean opacification in the main pulmonary artery < 250 HU) did not differ significantly between the study and control groups(7 vs 10).CONCLUSION A lower dose of iodine contrast at 60 mL can be feasibly used in CTPA without resulting in a higher number of sub-optimally opacified scans. 展开更多
关键词 Computed tomography pulmonary angiography contrast dose contrast induced nephropathy Acute kidney disease contrast safety contrast dose reduction Multiphasic injection
下载PDF
A new method for fluid identification and saturation calculation of low contrast tight sandstone reservoir
11
作者 Shuai Wang Ran-Hong Xie +2 位作者 Guo-Wen Jin Jiang-Feng Guo Li-Zhi Xiao 《Petroleum Science》 SCIE EI CAS CSCD 2024年第5期3189-3201,共13页
The resistivity difference between oil and gas layers and the water layers in low contrast tight sandstone reservoirs is subtle. Fluid identification and saturation calculation based on conventional logging methods ar... The resistivity difference between oil and gas layers and the water layers in low contrast tight sandstone reservoirs is subtle. Fluid identification and saturation calculation based on conventional logging methods are facing challenges in such reservoirs. In this paper, a new method is proposed for fluid identification and saturation calculation in low contrast tight sandstone reservoirs. First, a model for calculating apparent formation water resistivity is constructed, which takes into account the influence of shale on the resistivity calculation and avoids apparent formation water resistivity abnormal values.Based on the distribution of the apparent formation water resistivity obtained by the new model, the water spectrum is determined for fluid identification in low contrast tight sandstone reservoirs.Following this, according to the average, standard deviation, and endpoints of the water spectrum, a new four-parameter model for calculating reservoir oil and gas saturation is built. The methods proposed in this paper are applied to the low contrast tight sandstone reservoirs in the Q4 formation of the X53 block and X70 block in the south of Songliao Basin, China. The results show that the water spectrum method can effectively distinguish oil-water layers and water layers in the study area. The standard deviation of the water spectrum in the oil-water layer is generally greater than that in the water layer. The new four-parameter model yields more accurate oil and gas saturation. These findings verify the effectiveness of the proposed methods. 展开更多
关键词 Low contrast reservoirs Fluid identification Saturation calculation Water spectrum method Conventional logging
下载PDF
Signal intensity changes of dentate nucleus on plain MR T1WI innasopharyngeal carcinoma patients after radiotherapy andmultiple injections of gadolinium-base contrast agent
12
作者 SUN Jiping ZHOU Jian +2 位作者 TAO Zhigang LIANG Jiafeng DING Zhongxiang 《中国医学影像技术》 CSCD 北大核心 2024年第8期1170-1173,共4页
Objective To observe changes of plain MR T1WI signal intensity of dentate nucleus in nasopharyngeal carcinoma patients after radiotherapy and multiple times of intravenous injection of gadolinium-based contrast agent(... Objective To observe changes of plain MR T1WI signal intensity of dentate nucleus in nasopharyngeal carcinoma patients after radiotherapy and multiple times of intravenous injection of gadolinium-based contrast agent(GBCA).Methods Fifty patients with pathologically confirmed nasopharyngeal carcinoma and received intensity-modulated radiotherapy were retrospectively enrolled as the nasopharyngeal carcinoma group,and 50 patients with other malignant tumors and without history of brain radiotherapy were retrospectively enrolled as the control group.All patients received yearly GBCA enhanced MR examinations for the nasopharynx or the head.T1WI signal intensities of the dentate nucleus and the pons on same plane were measured based on images in the year of confirmed diagnosis(recorded as the first year)and in the second to the fifth years.T1WI signal intensity ratio of year i(ranging from 1 to 5)was calculated with values of dentate nucleus divided by values of the pons(ΔSI i),while the percentage of relative changes of year j(ranging from 2 to 5)was calculated withΔSI j compared toΔSI 1(Rchange j).The values of these two parameters were compared,and the correlation ofΔSI and GBCA injection year-time was evaluated within each group.Results No significant difference of gender,age norΔSI 1 was found between groups(all P>0.05).The second to the fifth yearΔSI and Rchange in nasopharyngeal carcinoma group were all higher than those in control group(all P<0.05).Within both groups,ΔSI was positively correlated with GBCA injection year-time(both P<0.05).Conclusion Patients with nasopharyngeal carcinoma who underwent radiotherapy and multiple times of intravenous injection of GBCA tended to be found with gradually worsening GBCA deposition in dentate nucleus,for which radiotherapy might be a risk factor. 展开更多
关键词 nasopharyngeal neoplasms RADIOTHERAPY contrast media cerebellar nuclei
下载PDF
Contrastive Consistency and Attentive Complementarity for Deep Multi-View Subspace Clustering
13
作者 Jiao Wang Bin Wu Hongying Zhang 《Computers, Materials & Continua》 SCIE EI 2024年第4期143-160,共18页
Deep multi-view subspace clustering (DMVSC) based on self-expression has attracted increasing attention dueto its outstanding performance and nonlinear application. However, most existing methods neglect that viewpriv... Deep multi-view subspace clustering (DMVSC) based on self-expression has attracted increasing attention dueto its outstanding performance and nonlinear application. However, most existing methods neglect that viewprivatemeaningless information or noise may interfere with the learning of self-expression, which may lead to thedegeneration of clustering performance. In this paper, we propose a novel framework of Contrastive Consistencyand Attentive Complementarity (CCAC) for DMVsSC. CCAC aligns all the self-expressions of multiple viewsand fuses them based on their discrimination, so that it can effectively explore consistent and complementaryinformation for achieving precise clustering. Specifically, the view-specific self-expression is learned by a selfexpressionlayer embedded into the auto-encoder network for each view. To guarantee consistency across views andreduce the effect of view-private information or noise, we align all the view-specific self-expressions by contrastivelearning. The aligned self-expressions are assigned adaptive weights by channel attention mechanism according totheir discrimination. Then they are fused by convolution kernel to obtain consensus self-expression withmaximumcomplementarity ofmultiple views. Extensive experimental results on four benchmark datasets and one large-scaledataset of the CCAC method outperformother state-of-the-artmethods, demonstrating its clustering effectiveness. 展开更多
关键词 Deep multi-view subspace clustering contrastive learning adaptive fusion self-expression learning
下载PDF
Effect of astigmatism and spherical equivalent correction on contrast sensitivity
14
作者 Maryam Saffarizadeh Saeed Rahmani +1 位作者 Alireza Akbarzadeh Baghban Mohammad Ghassemi-Broumand 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第12期2243-2247,共5页
AIM:To investigate the effect of astigmatism and spherical equivalent(SE)correction on contrast sensitivity(CS).METHODS:In this cross-sectional study,103 visually normal subjects aged 18 to 36y with bilateral regular ... AIM:To investigate the effect of astigmatism and spherical equivalent(SE)correction on contrast sensitivity(CS).METHODS:In this cross-sectional study,103 visually normal subjects aged 18 to 36y with bilateral regular astigmatism in range of 1.00 diopter cylinder(DC)to 4.00 DC and normal best-corrected visual acuity(20/20)were recruited.Binocular CS was assessed by linear sine-wave gratings at 1.5,3,6,12,and 18 cycles per degree(cpd),before correction of astigmatism,after full correction of astigmatism by cylindrical spectacle lenses,and after SE of refractive error.The repeated measures ANOVA and Bonferroni test were used to compare the effects of astigmatism correction on logCS.RESULTS:Totally 39 patients were male and 64 patients were female with the mean age of 28.25±5.38y.The average degree of astigmatism in right and left eye was 2.03±0.83 and 2.10±0.78,respectively.Increases in uncorrected astigmatic power correlated with decreases in the logCS,especially at high spatial frequencies.A statistically significant difference in logCS was found between these three cases:before correction of astigmatism,after SE of refractive error,and after full correction of astigmatism by cylindrical spectacle lenses at all frequencies(P<0.001),except at 18 cpd.At 18 cpd,there was no statistically significant difference between logCS before and after SE of refractive error(P=1.0).Also,there was no statistically significant difference in mean CS between with-the-rule(WTR)and against-the-rule(ATR)astigmatism,before correction of astigmatism,after correction of astigmatism with cylindrical lenses,and after SE of refractive error.CONCLUSION:Binocular astigmatism defocus decreases CS depending on the degree of astigmatism power;correction of this will improve patent’s quality of vision.Although high astigmatism refractive error(more than 2.00 DC)that is fully corrected by cylindrical spectacle lenses doesn’t increase the CS to the maximum value,especially at higher spatial frequencies(12 and 18).Also SE refractive error effects on improving CS in low astigmatism power(less than 2.00 DC),especially at lower spatial frequencies. 展开更多
关键词 ASTIGMATISM contrast sensitivity spherical equivalent
下载PDF
Optical design of a novel near-infrared phase contrast imaging(NI-PCI)diagnostic on the HL-2A tokamak
15
作者 徐皓 龚少博 +11 位作者 余羿 许敏 兰涛 王志斌 石中兵 聂林 赵光义 刘灏 周艺轩 袁子豪 肖晨雨 陈坚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期31-37,共7页
The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr... The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1). 展开更多
关键词 phase contrast imaging near infrared laser plasma laser diagnostic
下载PDF
Recommendation Method for Contrastive Enhancement of Neighborhood Information
16
作者 Hairong Wang Beijing Zhou +1 位作者 Lisi Zhang He Ma 《Computers, Materials & Continua》 SCIE EI 2024年第1期453-472,共20页
Knowledge graph can assist in improving recommendation performance and is widely applied in various person-alized recommendation domains.However,existing knowledge-aware recommendation methods face challenges such as ... Knowledge graph can assist in improving recommendation performance and is widely applied in various person-alized recommendation domains.However,existing knowledge-aware recommendation methods face challenges such as weak user-item interaction supervisory signals and noise in the knowledge graph.To tackle these issues,this paper proposes a neighbor information contrast-enhanced recommendation method by adding subtle noise to construct contrast views and employing contrastive learning to strengthen supervisory signals and reduce knowledge noise.Specifically,first,this paper adopts heterogeneous propagation and knowledge-aware attention networks to obtain multi-order neighbor embedding of users and items,mining the high-order neighbor informa-tion of users and items.Next,in the neighbor information,this paper introduces weak noise following a uniform distribution to construct neighbor contrast views,effectively reducing the time overhead of view construction.This paper then performs contrastive learning between neighbor views to promote the uniformity of view information,adjusting the neighbor structure,and achieving the goal of reducing the knowledge noise in the knowledge graph.Finally,this paper introduces multi-task learning to mitigate the problem of weak supervisory signals.To validate the effectiveness of our method,experiments are conducted on theMovieLens-1M,MovieLens-20M,Book-Crossing,and Last-FM datasets.The results showthat compared to the best baselines,our method shows significant improvements in AUC and F1. 展开更多
关键词 contrastive learning knowledge graph recommendation method
下载PDF
Position-Aware and Subgraph Enhanced Dynamic Graph Contrastive Learning on Discrete-Time Dynamic Graph
17
作者 Jian Feng Tian Liu Cailing Du 《Computers, Materials & Continua》 SCIE EI 2024年第11期2895-2909,共15页
Unsupervised learning methods such as graph contrastive learning have been used for dynamic graph represen-tation learning to eliminate the dependence of labels.However,existing studies neglect positional information ... Unsupervised learning methods such as graph contrastive learning have been used for dynamic graph represen-tation learning to eliminate the dependence of labels.However,existing studies neglect positional information when learning discrete snapshots,resulting in insufficient network topology learning.At the same time,due to the lack of appropriate data augmentation methods,it is difficult to capture the evolving patterns of the network effectively.To address the above problems,a position-aware and subgraph enhanced dynamic graph contrastive learning method is proposed for discrete-time dynamic graphs.Firstly,the global snapshot is built based on the historical snapshots to express the stable pattern of the dynamic graph,and the random walk is used to obtain the position representation by learning the positional information of the nodes.Secondly,a new data augmentation method is carried out from the perspectives of short-term changes and long-term stable structures of dynamic graphs.Specifically,subgraph sampling based on snapshots and global snapshots is used to obtain two structural augmentation views,and node structures and evolving patterns are learned by combining graph neural network,gated recurrent unit,and attention mechanism.Finally,the quality of node representation is improved by combining the contrastive learning between different structural augmentation views and between the two representations of structure and position.Experimental results on four real datasets show that the performance of the proposed method is better than the existing unsupervised methods,and it is more competitive than the supervised learning method under a semi-supervised setting. 展开更多
关键词 Dynamic graph representation learning graph contrastive learning structure representation position representation evolving pattern
下载PDF
Laser speckle contrast imaging to predict the effect of temporary spinal cord stimulation in postherpetic neuralgia patients: A prospective observational study
18
作者 Xiang Huang Dacheng Tang +3 位作者 Pan Chen Lumiao Chen Xiaohong Li Xiaoping Wang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期69-75,共7页
Temporary spinal cord stimulation(tSCS)can effectively reduce the pain and severity of postherpetic neuralgia(PHN).However,there are no effective and objective methods for predicting the effects of tSCS on PHN.Laser s... Temporary spinal cord stimulation(tSCS)can effectively reduce the pain and severity of postherpetic neuralgia(PHN).However,there are no effective and objective methods for predicting the effects of tSCS on PHN.Laser speckle contrast imaging(LSCI)is frequently used in neurology to evaluate the effectiveness of treatment.To assess the accuracy of LSCI in predicting the impact of tSCS on PHN,14 adult patients receiving tSCS treatments for spinal nerve-innervated(C6-T2)PHN participated in this observational study.Visual analog scale(VAS)assessments and LSCI bloodflow images of the-ngers were recorded after the tSCS procedure.The results showed that the VAS scores of all patients decreased signi-cantly.Moreover,the bloodflow index(BFI)values were signi-cantly higher than they were before the procedure.Increased bloodflow and pain alleviation were positively correlated.The-ndings indicated that spinal nerve PHN(C6-T2)was signi-cantly reduced by tSCS.Pain alleviation by tSCS was positively correlated with increased bloodflow in the hand.The effect of tSCS on PHN may thus be predicted using an independent and consistent indicator such as LSCI. 展开更多
关键词 Laser speckle contrast imaging temporary spinal cord stimulation postherpetic neuralgia
下载PDF
A Second-Order Image Denoising Model for Contrast Preservation
19
作者 Wei Zhu 《Communications on Applied Mathematics and Computation》 EI 2024年第2期1406-1427,共22页
In this work,we propose a second-order model for image denoising by employing a novel potential function recently developed in Zhu(J Sci Comput 88:46,2021)for the design of a regularization term.Due to this new second... In this work,we propose a second-order model for image denoising by employing a novel potential function recently developed in Zhu(J Sci Comput 88:46,2021)for the design of a regularization term.Due to this new second-order derivative based regularizer,the model is able to alleviate the staircase effect and preserve image contrast.The augmented Lagrangian method(ALM)is utilized to minimize the associated functional and convergence analysis is established for the proposed algorithm.Numerical experiments are presented to demonstrate the features of the proposed model. 展开更多
关键词 Image denoising Variational model Image contrast Augmented Lagrangian method(ALM)
下载PDF
Improved Weighted Local Contrast Method for Infrared Small Target Detection
20
作者 Pengge Ma Jiangnan Wang +3 位作者 Dongdong Pang Tao Shan Junling Sun Qiuchun Jin 《Journal of Beijing Institute of Technology》 EI CAS 2024年第1期19-27,共9页
In order to address the problem of high false alarm rate and low probabilities of infrared small target detection in complex low-altitude background,an infrared small target detection method based on improved weighted... In order to address the problem of high false alarm rate and low probabilities of infrared small target detection in complex low-altitude background,an infrared small target detection method based on improved weighted local contrast is proposed in this paper.First,the ratio information between the target and local background is utilized as an enhancement factor.The local contrast is calculated by incorporating the heterogeneity between the target and local background.Then,a local product weighted method is designed based on the spatial dissimilarity between target and background to further enhance target while suppressing background.Finally,the location of target is obtained by adaptive threshold segmentation.As experimental results demonstrate,the method shows superior performance in several evaluation metrics compared with six existing algorithms on different datasets containing targets such as unmanned aerial vehicles(UAV). 展开更多
关键词 infrared small target unmanned aerial vehicles(UAV) local contrast target detection
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部