期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Comparative study on density gradients and swim-up preparation techniques utilizing neat and cryopreserved spermatozoa 被引量:15
1
作者 ShyamS.R.Allamaneni AshokAgarwal +2 位作者 SreedharRama PavithraRanganathan RakeshK.Sharma 《Asian Journal of Andrology》 SCIE CAS CSCD 2005年第1期86-92, ,共7页
Aim: To 1) compare post-wash and post-thaw parameters of sperm processed with PureSperm density gradient technique and swim-up method; and 2) test the efficacy of two commonly available density gradient media PureSper... Aim: To 1) compare post-wash and post-thaw parameters of sperm processed with PureSperm density gradient technique and swim-up method; and 2) test the efficacy of two commonly available density gradient media PureSperm and ISolate. Methods: This prospective study used semen specimens from 22 patients. Specimens from nine patients were processed by both PureSperm density gradient and swim-up method. These specimens were then cryopreserved. Thirteen specimens were processed by both PureSperm (40 % and 80 %) and Isolate (50 % and 90 %) double density gradient techniques. The two fractions processed by both PureSperm and swim-up were analyzed for post-wash sperm characteristics. Post-thaw analysis was done after 24 hours. Sperm fractions obtained after processing with PureSperm and ISolate were compared for post-wash sperm characteristics and ROS levels. Results: Specimens prepared with PureSperm had significantly higher median total motile sperm counts (TMSC) (32.2 x 10~6 vs. 17.6 x 10~6), recovery rates (69.2 % vs. 50.0 %), and longevity at 4 hours (83.0 % vs. 55.0 %) compared to specimen prepared by swim-up. Post-thaw specimens also had a higher recovery and longevity at 4 hours with PureSperm as compared to the swim-up. Semen specimens processed by PureSperm had significantly higher total sperm count, TMSC, and percentage recovery rates (30.0 % vs. 19.7 %) than ISolate. Conclusion: Semen quality is better preserved in fresh and cryopreserved semen prepared with PureSperm density gradient compared to swim-up. A significant enrichment of sperm is observed with PureSperm compared to ISolate. Higher recovery rates of mature motile sperm obtained after PureSperm sperm preparation may be beneficial for successful ART. i 展开更多
关键词 SPERMATOZOA CRYOPRESERVATION density gradient centrifugation sperm motility
下载PDF
DIAGNOSTIC VALUE OF DENSITY GRADIENT CENTRIFU-GATION FOR EXFOLIATIVE TUMOR CELLS IN MALIG-NANT PLEURAL EFFUSIONS
2
作者 郭胤仕 朱任之 《Journal of Shanghai Second Medical University(Foreign Language Edition)》 2004年第2期118-120,共3页
Objective To find out a specific method for diagnosis of malignant pleural effusions (MPEs)with higher sensitivity and practicality. Methods The diagnosis of MPEs were made using density gradient cen-trifugation(DGC) ... Objective To find out a specific method for diagnosis of malignant pleural effusions (MPEs)with higher sensitivity and practicality. Methods The diagnosis of MPEs were made using density gradient cen-trifugation(DGC) , smear cytologic examination( SCE) and pleural needle biopsy (PNB). Comparisons between these results and those of benign pleural effusions were also made. Results The positive rates of DGC,SCE and PNB for diagnosing MPEs were 94. 3% ,62. 9% and 44. 6% , respectively, and the positive rate of SCE combined with PNB for diagnosing MPEs was 73. 2%. The positive rate of the exfoliative tumor cells ( ETCs ) by DGC was much higher than that of SCE or/and PNB with no false-positive. Conclusion The ETCs isolated by DGC from the MPEs is quite specific for the diagnosis of malignant tumors with higher sensitivity and practicality in clinico-patho-logical practice. 展开更多
关键词 pleural effusion density gradient centrifugation exfoliative cells cytologic examination
下载PDF
Phospholipase C-Zeta Reveals the Underlying Pathological Influence after Density Gradient Centrifugation, Microfluidic Sorting, and Cryopreservation of Human Sperm
3
作者 CAI Jing-jing 《Chinese Journal of Biomedical Engineering(English Edition)》 CAS 2023年第1期1-10,18,共11页
Objective:Sperm preparation techniques and cryopreservation are widely used in assisted reproductive techniques(ART).How to improve the quality of sperm management is a matter of great concern.Phospholipase C-zeta(PLC... Objective:Sperm preparation techniques and cryopreservation are widely used in assisted reproductive techniques(ART).How to improve the quality of sperm management is a matter of great concern.Phospholipase C-zeta(PLCζ)is considered a sperm-specific agent that activates oocyte activation and thus playing a crucial role in male fertility.However,the potential mechanisms by which semen processing and cryopreservation on PLCζcontribute to keyhole have not been addressed.Methods:In this study,semen samples were taken from have not been addressed 10 normozoospermic men.Each semen sample was assigned to the following groups:density gradient centrifugation(DGC)as control,microfluidic sorting,and cryopreservation.Sperm parameters of molity,viability,membrane integrity,and intracellular ROS were evaluated during sperm preparation and cryopreservation.The expression of PLCζin human sperm was determined by immunofluorescence and western blotting.Results:The results showed that molity,viability,and membrane integrity decreased in cryopreservation group.Intracellular ROS were also significantly increased compared to the the control group.There was no significant difference between DGC and microfluidic sorting group.Our investigation revealed that total levels of PLCζwere comparable between DGC and microfluidic sorting,but there were significantly reduced levels of PLCζafter cryopreservation as quantified by both immunofluorescenceand immunoblotting.PLCζimmunofluorescence in sperm revealed different PLCζlocalization patterns around the acrosomal(Ac),equatorial(Eq),post-acrosomal(PA)areas of sperm heads,and their combination.The predominant patterns of PLCζlocalization in DGC were similar to that of microfluidic sorting,with strong,with staining.In contrast,PLCζstaining in freeze-thawed sperm was considerably weaker fluorescence intensity.Conclusion:This study clarified the mechanism of sperm preparation and cryopreservation underlying effect on sperm characteristic,accompanied with PLCζexpresion.We demonstrated that microfluidic sorting provides a highly efficient preparation method for clinical selection of PLCζ-expressing sperm comparable to DGC gene expression.It is suggested that the cryopreservation of sperm has a significant detrimental effect on PLCζ. 展开更多
关键词 microfluidic sorting density gradient centrifugation(DGC) CRYOPRESERVATION oocyte activation phospholipase C-zeta(PLCζ)
原文传递
Single and double layer centrifugation improve the quality of cryopreserved bovine sperm from poor quality ejaculates
4
作者 Alessia Gloria Augusto Carluccio +3 位作者 Laura Wegher Domenico Robbe Giovanni Befacchia Alberto Contri 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2017年第1期80-88,共9页
Background: Density gradient centrifugation was reported as a technique of semen preparation in assisted reproductive techniques in humans and animals. This technique was found to be efficient in improving semen qual... Background: Density gradient centrifugation was reported as a technique of semen preparation in assisted reproductive techniques in humans and animals. This technique was found to be efficient in improving semen quality after harmful techniques such as cryopreservation. Recently a modified technique, single layer centrifugation,was proposed as a technique providing a large amount of high quality spermatozoa, and this treatment was performed before conservation. Single layer centrifugation has been studied prevalently in stallions and in boars,but limited data were available for bulls. Occasionally bulls are known to experience a transient reduction in semen quality, thus techniques that allow improvement in semen quality could be applied in this context. The aim of this study was the evaluation of single layer and double layer centrifugation by the use of iodixanol, compared with conventional centrifugation and non-centrifuged semen, on the sperm characteristics during the cryopreservation process in bulls with normal and poor semen quality.Results: Single layer centrifugation and double layer centrifugation both significantly increased the percentage of normal spermatozoa and decreased the percentage of non-sperm cells in poor quality samples, while both were ineffective in those of normal quality. Sperm characteristics in poor quality samples increased after single layer centrifugation and double layer centrifugation, reaching values similar to those recorded in normal samples, and this trend is maintained after equilibration and after cryopreservation. On the other hand, SLC and DLC resulted in a consistent reduction in the spermatozoa recovered, and this resulted in a reduction of the absolute amount of spermatozoa cryopreserved in the normal samples, without a clear improvement in sperm characteristics in this type of sample.Conclusions: These data suggested that both SLC and DLC could be performed in practice, but their application should be limited to the cases in which the quality of the spermatozoa recovered is more important than the total amount of spermatozoa. 展开更多
关键词 Bull Cryopreservation density gradient centrifugation Iodixanol Semen analysis
下载PDF
Changes in human sperm motility and DNA fragmentation index after incubation at different temperatures following density gradient centrifugation and swim-up procedures
5
作者 Yan-Nan Yang Ling Wang +5 位作者 Yu-Bing Liu Yun-Jing Xue Chen-Chen Liu Fei Shi Xue Dai Ri-Cheng Chian 《Reproductive and Developmental Medicine》 CSCD 2022年第4期243-248,共6页
Objective:The purpose of this study was to evaluate the sperm motility and DNA integrity at different temperatures to analyze whether the sperms are suitable on the second day for insemination of in vitro matured oocy... Objective:The purpose of this study was to evaluate the sperm motility and DNA integrity at different temperatures to analyze whether the sperms are suitable on the second day for insemination of in vitro matured oocytes by intra-cytoplasmic sperm injection(ICSI)following density gradient centrifugation(DGC)and swim-up(SU)procedures.Methods:Semen samples were collected from 30 outpatients who visited the Center for Reproductive Medicine for semen analyses.Following sperm selection by DGC and SU procedures,the liquified semen samples were divided into three groups and incubated at 4,25,and 37°C,respectively.Following incubation for 24,48,and 72 hours,the sperm motility and sperm DNA fragmentation index(DFI)were analyzed.Results:Following the combination of DGC and SU procedures,the sperm motility(91.8%±8.6%vs.50.8%±13.1%)and DFI(5.1%±7.9%vs.13.0%±11.6%)were significantly improved(P<0.01)compared to those without any treatment.The sperm motility of the 3 groups significantly declined(P<0.05)post-incubation compared to that of the groups prior incubation.However,sperm motility significantly increased(76.9%±10.4%)(P<0.05)at 25°C compared to that of the other 2 groups(53.5%±11.0%and 47.6%±10.2%).Sperm DFI significantly increased(P<0.05)at 37°C following incubation for 24 and 72 hours in comparison to that of the other 2 groups.However,the sperm DFI did not significantly increase when the sperm samples were incubated at 4(5.7%±5.9%)and 25°C(6.8%±5.6%)for 24 hours compared to that before incubation(5.1%±7.9%).Conclusions:These results indicate that the sperm quality,in terms of motility and DFI,can be efficiently improved by DGC in combination with SU.Following which,the sperm samples can be incubated at 25°C and be used on the second day for insemination of in vitro matured oocytes by ICSI. 展开更多
关键词 Sperm motility density gradient centrifugation SWIM-UP DNA fragmentation index matured oocytes
原文传递
A laboratory modification to testicular sperm preparation technique improves spermatogenic cell yield 被引量:2
6
作者 Sinan Ozkavukcu Ebru Ibis +2 位作者 Sule Kizil Suheyla Isbacar Kaan Aydos 《Asian Journal of Andrology》 SCIE CAS CSCD 2014年第6期852-857,共6页
Testicular sperm extraction is a common procedure used to find spermatogenic cells in men with nonobstructive azoospermia. The laboratory processing of biopsied testicular tissues needs to be performed meticulously to... Testicular sperm extraction is a common procedure used to find spermatogenic cells in men with nonobstructive azoospermia. The laboratory processing of biopsied testicular tissues needs to be performed meticulously to acquire a high yield of cells. In this study, the effectiveness of mincing the tissues after testicular biopsy was assessed using histological evaluation, as was the possible adverse effect of residual tissue on the migration of spermatogenic cells during density gradient centrifugation. Our results indicate that testicular residual tissue, when laid on the density gradient medium along with the sperm wash, hinders the spermatogenic cells' forming a pellet during centrifugation, and therefore impairs the intracytoplasmic sperm injection procedure. Whereas the mean number of recovered cells from the sperm wash medium (SWM) with residual tissue is 39.435 ~ 24.849, it was notably higher (60.189 ~ 28.214 cells) in the SWM without minced tissues. The remaining tissue contained no functional seminiferous tubules or spermatogenic cells in histological sections. In conclusion, the remaining residual tissue after mincing biopsied testicular tissue does not add any functional or cellular contribution to spermatogenic cell retrieval; in fact, it may block the cellular elements in the accompanying cell suspension from migrating through the gradient layers to form a pellet during centrifugation and cause loss of spermatogenic cells. 展开更多
关键词 assisted reproductive techniques AZOOSPERMIA gradient density centrifugation sperm yield testicular sperm extraction
下载PDF
Preparation and incubation conditions affect the DNA integrity of ejaculated human spermatozoa 被引量:10
7
作者 Rieko Matsuura Takumi Takeuchi Atsumi Yoshida 《Asian Journal of Andrology》 SCIE CAS CSCD 2010年第5期753-759,共7页
Appropriate semen processing and assessment are critical for successful infertility treatment. We investigated whether laboratory procedures including semen preparation and incubation affect sperm DNA integrity. A tot... Appropriate semen processing and assessment are critical for successful infertility treatment. We investigated whether laboratory procedures including semen preparation and incubation affect sperm DNA integrity. A total of 153 infertile men were involved. Conventional semen parameters and sperm chromatin structure assay (SCSA) parameters, that is, DNA fragmentation index (%DFI) and high DNA stainability (%HDS), were assessed on the flesh ejaculated semen samples, which were treated and incubated under different conditions. Negative correlations were identified between the %DFI and sperm concentration, motility, progressive motility and morphology. A lower percentage of DFI was detected in spermatozoa when density gradient centrifugation (DGC) was followed by swimup treatment in comparison with DGC alone (P 〈 0.01). Although the %DFI increased in a time-dependent manner with incubation both at room temperature (RT) and at 37℃ in air, the %DFI after 24 h at RT was significantly lower than that at 37℃ (P 〈 0.05). Incubation with 5% CO2 was effective in maintaining sperm motility (P 〈 0.01); however, it induced further elevation of %DFI (P 〈 0.001). Thus, sperm DNA damage was associated with longer incubation periods. Interestingly, common culture conditions, such as maintaining pH and temperature, compromised the sperm DNA integrity. 展开更多
关键词 density gradient centrifugation DNA damage male infertility sperm chromatin structure assay SPERMATOZOA
下载PDF
Selective Suspension in Aqueous Sodium Dodecyl Sulfate According to Electronic Structure Type Allows Simple Separation of Metallic from Semiconducting Single-Walled Carbon Nanotubes 被引量:7
8
作者 Kai Moshammer Frank Hennrich Manfred M.Kappes 《Nano Research》 SCIE EI CSCD 2009年第8期599-606,共8页
Both density gradient centrifugation and gel electrophoresis have been reported to allow high throughput separation of metallic from semiconducting single-walled carbon nanotubes(SWNTs)when using aqueous sodium dodecy... Both density gradient centrifugation and gel electrophoresis have been reported to allow high throughput separation of metallic from semiconducting single-walled carbon nanotubes(SWNTs)when using aqueous sodium dodecyl sulphate(SDS)suspensions.We show here that both methods rely on an initial dispersion-by-sonication step,which is already selective with respect to electronic structure type.The corresponding aqueous SDS“starting”suspensions obtained after sonication and purifi cation by simple centrifugation(70,000 g,1 h)contain semiconducting SWNTs primarily in the form of small bundles whereas metallic SWNTs are predominantly suspended as individual tubes.Density gradient centrifugation then separates the bundles from the individual tubes on the basis of differences in their overall buoyant densities.Gel electrophoresis separates the longer bundles from the shorter individual tubes on the basis of their different mobilities.We also demonstrate that such starting suspensions can be fractionated according to electronic structure type by even simpler techniques such as size exclusion chromatography or gel fi ltration,thus opening the way for simple scale-up. 展开更多
关键词 Single-walled carbon nanotubes metallic–semiconducting separation ELECTROPHORESIS density gradient centrifugation size exclusion chromatography
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部