期刊文献+
共找到533篇文章
< 1 2 27 >
每页显示 20 50 100
Dynamic propagation velocity of a positive streamer in a 3 m air gap under lightning impulse voltage
1
作者 李志伟 雷挺 +5 位作者 苏宇 姚修远 杨冰雪 刘德龙 律方成 丁玉剑 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期114-121,共8页
Streamers represent an important stage in the initiation of gap discharge. In this work, we used an eight-frame intensified charge-coupled device camera to capture the streamer development process when a lightning imp... Streamers represent an important stage in the initiation of gap discharge. In this work, we used an eight-frame intensified charge-coupled device camera to capture the streamer development process when a lightning impulse voltage of 95%–100% U50% was applied in a 3 m rod–plate gap and the streamer velocity was analyzed. Analysis of the observations shows that streamer velocity can be defined by three stages: rapid velocity decline(stage 1), rapid velocity rise(stage 2)and slow velocity decline(stage 3). The effects of electrode shape, applied voltage and gap breakdown or withstanding on streamer velocity were analyzed. The electrode with a larger radius of curvature will result in a higher initial velocity, and a higher voltage amplitude will cause the streamer to propagate faster at stage 3. Gap withstanding or breakdown has no obvious effect on streamer velocity. In addition, the experimental results are compared with previous results and the statistical characteristics of the primary streamer discharge are discussed. 展开更多
关键词 lightning impulse 3 m air gap development process streamer velocity
下载PDF
Insulation characteristics of triple mixtures of c-C_4F_8/N_2/CO_2 under lightning impulse voltage 被引量:1
2
作者 Zhouming ZHANG Zhaorui NI +1 位作者 Dengming XIAO Yizhou WU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第10期112-117,共6页
This paper has researched the insulation characteristics of 10% c-C4F8/N2/CO2 mixtures under lightning impulse voltage by experiment. It is shown that the positive and negative lightning impulse breakdown voltages of ... This paper has researched the insulation characteristics of 10% c-C4F8/N2/CO2 mixtures under lightning impulse voltage by experiment. It is shown that the positive and negative lightning impulse breakdown voltages of 10%c-C4F8/N2/CO2 gas mixtures rise linearly as the electrode gap distance and gas pressure increase and under the same conditions, the positive lightning impulse breakdown voltage of the gas mixtures is always higher than the negative lightning impulse breakdown voltage. As the gas mixtures have a little higher liquefied temperature than SF6 and the comprehensive GWP is about 5% of SF6, and the positive and negative lightning impulse breakdown voltages can both reach 60% of SF6, 10%c-C4F8/N2/CO2 gas mixtures can be applied as insulation gas in electrical equipment such as C-GIS, GIT, GIL and so on. 展开更多
关键词 SF6 alternative insulation characteristics lightning impulse voltage c-C4F8 gas mixtures
下载PDF
Movement Patterns of Metallic Particles in a Single Phase Gas Insulated Busduct with Superimposed Lightning and Switching Impulses 被引量:1
3
作者 M. Venu Gopala Rao J. Amarnath +2 位作者 G.V. Nagesh Kumar S. Kamakshaiah K. D. Srivastava 《高电压技术》 EI CAS CSCD 北大核心 2008年第12期2642-2647,共6页
Transient over voltages due to lightning and switching surges cause steep build-up of voltage on transmission lines and other electrical apparatus,like circuit breakers,transformers,insulators etc.Therefore it is nece... Transient over voltages due to lightning and switching surges cause steep build-up of voltage on transmission lines and other electrical apparatus,like circuit breakers,transformers,insulators etc.Therefore it is necessary for the GIS also to withstand such voltages without breakdown of Insulation.The system has to be tested under these conditions.Usually the GIS system operates on power frequency.Lightning Impulse Voltage of 1050 kV and Switching Impulse Voltage of 750 kV superimposed on Power frequency voltages of 75 kV,100 kV and 132 kV are applied to Single Phase Gas Insulated Busduct and the maximum movement of Aluminum,Copper and Silver particles is determined.The movement patterns are also determined with and without Monte Carlo Simulation for movement of particle in axial and radial directions.The results show that there is a sudden jump in the movement at the application of impulse on sine wave.This is because of high magnitude voltage of 1050 kV during 1.2/50 μs.Similar movement patterns of reduced maximum movement is observed for Switching Impulse superimposed on sine wave.The results are presented and analyzed. 展开更多
关键词 重复雷击 金属微粒 运动形态 气相绝缘站 粒子污染物
下载PDF
Properties of Electrical Discharges Developing in Transformer Oil Under Lightning Impulse in the Setup of Insulated Electrodes
4
作者 Pawel Rozga 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1805-1812,共8页
Looking at the problem of electrical discharge development in mineral oil, it is easy to see that most studies in this area focused on the setups of bare high voltage electrodes having a point-plane electrode arrangem... Looking at the problem of electrical discharge development in mineral oil, it is easy to see that most studies in this area focused on the setups of bare high voltage electrodes having a point-plane electrode arrangement. The setups with insulated electrodes are the mar- gin of these studies but it seems to be important to find the dependences between the paper insulation on high voltage electrode and parameters of the discharges initiated in the vicinity of this electrode. Hence, in this paper the results of researches intended to reveal the role of insulation wrapping on a HV electrode in the mechanism of electrical discharges in transformer oil under lightning impulse of both polar- ities are presented. This role is determined by analysis of the parameters characterizing the discharges (onset voltage, propagation velocity, time to initiation, rise-time of light impulses) and also by observation of their spatio-temporal development and oscillograms of the light emitted by their channels. The research was performed for two model electrode configurations: an electrode with paper insulation and a bare electrode which had the same outer dimensions as the insulated one. The most essential conclusion from performed experiment is related to times to initiation. These times, equal in the case of insulated electrodes and model bare electrode, indicate that the source of "weak points" of the paper-oil insulation system is the oil, not the surface of insulation wrapping or the metal. 展开更多
关键词 高压电极 放电特性 雷电冲击 变压器油 绝缘纸 上升时间 安装 开发
下载PDF
Quality Assessment of FY-4A Lightning Data in Inland China 被引量:4
5
作者 LIU Rui-xia LU Qi-feng +3 位作者 CHEN Min ZHANG Yong HUI Wen LI Xiao-qing 《Journal of Tropical Meteorology》 SCIE 2020年第3期286-299,共14页
The Lightning Mapping Imager(LMI)equipped on the FY-4 A(Feng Yun-4 A)geostationary satellite achieves lightning positioning through optical imaging and has the advantages of high temporal resolution,high stability,and... The Lightning Mapping Imager(LMI)equipped on the FY-4 A(Feng Yun-4 A)geostationary satellite achieves lightning positioning through optical imaging and has the advantages of high temporal resolution,high stability,and continuous observation.In this study,FY-4 A LMI lightning event,group and flash data from April to August 2018 are selected,and their quality are assessed through qualitative and quantitative comparison with the ground-based Advanced Time of Arrival and Direction system(ADTD)lightning observation network data and the American International Space Station(ISS)lightning imaging sensor(LIS)data.The results show that the spatial distributions of FY-4 A lightning are consistent with those of the ground-based ADTD and ISS LIS.The temporal variation in FY-4 A lightning group frequency is consistent with that of ADTD stroke,which reflects that FY-4 A LMI can capture the lightning occurrence in inland China.Quantitative statistics show that the consistency rate of FY-4 A LMI and ISS LIS events is relatively high but their consistency rate is lower in terms of lightning group and flash data.Compared with the lightning observations by the ISS LIS and the ground-based ADTD,FY-4 A LMI reports fewer lightning events in the Tibetan Plateau.The application of Tibetan Plateau lightning data requires further processing and consideration. 展开更多
关键词 FY-4A lightning data quality assessment inland China ADTD ISS liS
下载PDF
The Performance of Lightning Rod Arrester and Its Effect on the Top Potential of Tower for 500 kV Transmission System
6
作者 Jian’gang Gong Zhouyou Lin +2 位作者 Yangyong Xu Shen Zhao Qiang Zhang 《Journal of Power and Energy Engineering》 2014年第11期19-23,共5页
When the tower overhead is struck by the lightning impulse, the lightning current flows into the earth through the impedance of tower and the grounding resistance, which heightens potential of the tower overhead and p... When the tower overhead is struck by the lightning impulse, the lightning current flows into the earth through the impedance of tower and the grounding resistance, which heightens potential of the tower overhead and possibly induces insulator flashover. Lighting rod arrester is used to shield the tower and provide another routine for lightning current, decreasing the potential of tower overhead. In this paper, the performance of a 500 kV lighting rod arrester is tested used in AC transmission system under the current impulse. Besides, the influence of the lightning rod arrester performance on the top potential of tower is also studied. The results show that, when the rod arrester is connected to the tower, the top potential of tower can be obviously limited under the lightning strike. 展开更多
关键词 lightning impulse Grounding Resistance lightning Rod Top POTENTIAL of TOWER Insulator FLASHOVER lightning Protection
下载PDF
Comparison Voltage across Insulator Strings of 69 kV and 24 kV Lines due to Lightning Strokes to Top Pole and Mid Span
7
作者 Nattachote Rugthaicharoenchep Wetarin Thansiphrasertt~ +1 位作者 Nattapong Suwannachot Att Phayomhom 《Journal of Energy and Power Engineering》 2013年第7期1382-1387,共6页
This paper analyzes the effects of the voltage across insulator of 69 kV and 24 kV lines installed on the same pole. The case studies illustrated the lightning strike to direct top pole and mid span of ground wire usi... This paper analyzes the effects of the voltage across insulator of 69 kV and 24 kV lines installed on the same pole. The case studies illustrated the lightning strike to direct top pole and mid span of ground wire using the ATP-EMTP (Alternative Transient Program-Electromagnetic Transient Program). The results found that when lightning strike the voltage across the 69 kV line insulator at mid span is 1.55 times and 1.34 times higher than at top pole when the front time is 0.25/100μs and 10/350 μs, respectively. When lightning strike the voltage across the 24 kV line at mid span is 1.04 times and 0.64 times higher than at top pole when the front time is 0.25/100μs and 10/350μs, respectively. So the effect of lightning strike is more severe at mid span than at the direct top pole, especially for the 69 kV insulator. 展开更多
关键词 Overhead ground wire ground rod INSULATOR subtransmission ATP-EMTP lightning concrete pole impulse impedance.
下载PDF
Experimental investigation on ablation characteristics of coated and uncoated steel under 30/80 μs impulse current
8
作者 Mingqiu DAI Yakun LIU +2 位作者 Zhengcai FU Juan LIU Xiaolei BI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第7期123-134,共12页
The ablation tests on coated and uncoated Q235 B steel sheets were conducted under 30/80 μs impulse current simulating the lightning first return stroke current, aimed at further understanding the ablation characteri... The ablation tests on coated and uncoated Q235 B steel sheets were conducted under 30/80 μs impulse current simulating the lightning first return stroke current, aimed at further understanding the ablation characteristics of steel and investigating the impact of anti-corrosion coating on these characteristics. Ablation characteristics were investigated through the macroscopic morphology and x-ray diffraction patterns on the surface of damaged zones, the microstructure and micro Vickers hardness on the cross-section of damaged zones, and the maximum rear-face temperature of sample sheets. It can be concluded that the ablation areas of uncoated sheet consist of the melted layer and the heat-affect layer. These ablation areas include not only the area ablated directly by the arc root, of which the depth is deeper, but also the area forming due to the splashing of molten steel, of which the depth is shallower and decreases when the area’s distance from the arc attachment point increases. For coated sheet, coating materials have decomposed and evaporated forming an ablation pit on the sheet surface, in which the steel surface is exposed, and zinc filler of coating primer has infused into the exposed surface. The ablation diameter of uncoated sheet relates to the amplitude of the 30/80 μs impulse current in quadratic function, while for coated sheet, the relation is linear. In general, under the 30/80 μs impulse current, the coating can decrease the energy injected from the arc to the steel sheet and reduce the melting and splashing of steel. As a result, the ablation severity of uncoated sheet is severer than that of coated sheet. 展开更多
关键词 arc ablation effect ANTI-CORROSION coating lightning first return stroke CURRENT 30/80 μs impulse CURRENT Q235B STEEL microstructure x-ray diffraction
下载PDF
用TRMM/LIS资料分析长江三角洲地区的闪电活动 被引量:46
9
作者 戴建华 )秦虹 郑杰 《应用气象学报》 CSCD 北大核心 2005年第6期728-736,共9页
统计分析了1998~2004年长江三角洲(长三角)地区由星载闪电成像传感器(LIS)观测的闪电资料,发现了该地区LIS闪电活动的一些时空分布特征:闪电次数的年差异较大,最多年份是最少年份的3倍;7~8月盛夏季节是闪电高发期,闪电次数和日数分别... 统计分析了1998~2004年长江三角洲(长三角)地区由星载闪电成像传感器(LIS)观测的闪电资料,发现了该地区LIS闪电活动的一些时空分布特征:闪电次数的年差异较大,最多年份是最少年份的3倍;7~8月盛夏季节是闪电高发期,闪电次数和日数分别占全年的70%和60%;闪电高发期间的抬升指数(IL)小于-2 ℃;7~8月闪电主要集中于午后,3~6月则集中在上半夜;上海地区单日LIS闪电次数超过8次时,多伴有强对流天气和短时强降水;长三角地区的闪电活动区主要分布在上海的东部,部分沿江、沿湖地区和浙江的龙门山等山区;水域闪电少于陆地,大城市城区下风方向闪电活动较多,部分雷暴刚入海时有加强的趋势.分析表明:太阳辐射的季节变化和日变化等是造成闪电时间分布的主要原因;地形的动力作用和下垫面的物理特性及其差异是造成气候意义上中小尺度闪电空间分布差异的主要原因.文章对LIS闪电定位资料进行了探测效率订正,根据LIS注视时间计算了闪电密度,并与地基闪电定位资料和多普勒天气雷达资料进行了对比.LIS闪电活动特征的分析,对雷暴预警和防灾减灾有指导意义. 展开更多
关键词 长江三角洲地区 闪电活动 TRMM资料 liS资料 星载闪电成像传感器 时空分布
下载PDF
基于LIS/OTD格点数据的中国东北地区雷击火时空分布原因分析 被引量:2
10
作者 赵俊卉 郭广猛 +2 位作者 亢新刚 董斌 周梅 《内蒙古农业大学学报(自然科学版)》 CAS 2008年第3期49-54,共6页
东北是中国雷击火发生最频繁的地区,因此有必要研究该地区的闪电活动规律。本文根据美国NASA提供的LIS/OTD v2.2格点资料,分析了东北地区闪电活动的时空分布。并结合雷击火的时空分布,用东北地区的气象资料、DEM数据和植被数据,分析了... 东北是中国雷击火发生最频繁的地区,因此有必要研究该地区的闪电活动规律。本文根据美国NASA提供的LIS/OTD v2.2格点资料,分析了东北地区闪电活动的时空分布。并结合雷击火的时空分布,用东北地区的气象资料、DEM数据和植被数据,分析了雷击火发生的原因。结果表明闪电在呼伦贝尔盟和黑河地区活动频繁,7月闪电最集中;而雷击火在大兴安岭、呼伦贝尔盟和黑河地区分布较多,6月份雷击火最多。可见二者在空间分布上大致一致,但也存在差异;在时间分布上有明显差别。本文研究发现,大兴安岭闪电活动不多,但雷击火频繁发生,主要原因是:地形起伏大、受大气环流影响容易形成干暴雷、易燃物分布广泛;相对于7月、8月来说,6月份闪电值较小但雷击火最多,主要原因是:7月、8月份降水多、相对湿度大、风速小,不容易着火。 展开更多
关键词 liS/OTD 闪电活动 雷击火 时空分布 植被分布 数字高程模型 气象因子
下载PDF
LIS和LD-Ⅱ雷电数据质量分析 被引量:1
11
作者 周后福 郭品文 《安徽农业科学》 CAS 北大核心 2009年第10期4556-4559,4593,共5页
基于2007年全年主要闪电过程的TRMM/LIS探测闪电定位数据和LD-Ⅱ型闪电定位数据,应用图像定性对比、比例定量比较等方法,对闪电定位数据探测质量进行分析研究。结果表明:①尽管LD-Ⅱ闪电数据明显少于LIS闪电数据,但是两类闪电数据的分... 基于2007年全年主要闪电过程的TRMM/LIS探测闪电定位数据和LD-Ⅱ型闪电定位数据,应用图像定性对比、比例定量比较等方法,对闪电定位数据探测质量进行分析研究。结果表明:①尽管LD-Ⅱ闪电数据明显少于LIS闪电数据,但是两类闪电数据的分布形态基本相同。②分别以LD-Ⅱ闪电数据和LIS闪电数据为基准,各个闪电过程比例的变化各有特点,大致都可以分成2类,一类是变化比较平缓,一类是变化比较剧烈,每个种类都有13次闪电过程,其界限值分别为17%和13%。③以LIS闪电数据为基准,相同距离范围时其比例要比LD-Ⅱ闪电数据为基准的小,以及此时的界限值要低,原因为LIS闪电数据的定位精度比LD-Ⅱ闪电数据准确。④两种闪电定位数据的比较可知,0.1s的时间间隔基本上可以当成1次闪电。 展开更多
关键词 雷电 liS LD-Ⅱ 闪电定位 数据质量
下载PDF
基于Simulink的冲击电压放电试验仿真系统
12
作者 杨玲 王智东 +2 位作者 邓丰强 梁梅 董笑 《环境技术》 2021年第4期217-221,共5页
雷电冲击电压放电试验用以检测电力设备在运行过程中承受暂时过电压及雷电过电压时的绝缘水平,是系统中常见的设备绝缘测试方法。传统的测试方法涉及的设备元器件多,搭建试验平台较为繁琐,且参数计算与测试过程用时较长,因此测试效率较... 雷电冲击电压放电试验用以检测电力设备在运行过程中承受暂时过电压及雷电过电压时的绝缘水平,是系统中常见的设备绝缘测试方法。传统的测试方法涉及的设备元器件多,搭建试验平台较为繁琐,且参数计算与测试过程用时较长,因此测试效率较低。本论文研究了一种基于Simulink的冲击电压放电试验仿真系统,该系统首先对试验设备进行建模,通过仿真的方法计算合理的试验参数,运行得出理想的试验结果,再以此作为依据在测试平台上进行试验。采用冲击电压放电试验仿真系统进行雷电冲击电压放电试验,可大幅缩短试验时间,提高测试效率。 展开更多
关键词 雷电冲击 绝缘测试 SIMUliNK 建模仿真
下载PDF
基于TRMM/LIS资料的浙江省及周边地区闪电特征和气象要素分析 被引量:3
13
作者 张祎 边学文 +2 位作者 王康挺 张卫斌 王振会 《热带气象学报》 CSCD 北大核心 2021年第4期602-610,共9页
利用TRMM/LIS0.1°超高分辨率闪电定位产品,分析了浙江省及周边地区(117.5~123.0°E,26~32°N)卫星闪电资料的时空分布特点;并结合中国区域地面气象要素驱动数据集、亚洲大陆气溶胶光学厚度数据集,分析了该区域闪电与气象... 利用TRMM/LIS0.1°超高分辨率闪电定位产品,分析了浙江省及周边地区(117.5~123.0°E,26~32°N)卫星闪电资料的时空分布特点;并结合中国区域地面气象要素驱动数据集、亚洲大陆气溶胶光学厚度数据集,分析了该区域闪电与气象要素的关系。结果表明:研究区域内闪电平均密度为5.97f1/(km^(2)·a),其中陆地闪电平均密度为7.94f1/(km^(2)·a),海洋闪电平均密度为2.09f1/(km^(2)·a),陆地闪电平均密度为海洋闪电平均密度的3.80倍;平均闪电密度值逐月变化特征在陆地和海洋区域有很好的一致性,夏季闪电密度最大,冬季闪电密度值最小;陆地闪电密度日变化呈现单峰结构,海洋闪电密度日变化呈现双峰双谷波形。该区域陆地气温、地面辐射、比湿及降水率均与闪电密度的月变化成正相关,其中地面降水率和闪电密度月变化相关系数最高,为0.8580;气溶胶光学厚度与闪电密度月变化呈现弱的负相关,相关系数为-0.3978。 展开更多
关键词 TRMM/liS 闪电 时空分布 气象要素 相关分析
下载PDF
负极性OLIV下GIS局部放电UHF信号的相位特征 被引量:7
14
作者 饶章权 郑书生 +3 位作者 王增彬 陈义龙 吴吉 吕鸿 《高电压技术》 EI CAS CSCD 北大核心 2019年第12期3924-3931,共8页
为实现冲击电压下气体绝缘开关设备(GIS)局部放电(PD)缺陷的诊断,通过试验测量与信号分析研究了在冲击电压作用下典型GIS缺陷的局部放电特高频信号特征。首先,搭建负极性振荡型雷电冲击电压下GIS局部放电试验平台,设置高压金属尖端、悬... 为实现冲击电压下气体绝缘开关设备(GIS)局部放电(PD)缺陷的诊断,通过试验测量与信号分析研究了在冲击电压作用下典型GIS缺陷的局部放电特高频信号特征。首先,搭建负极性振荡型雷电冲击电压下GIS局部放电试验平台,设置高压金属尖端、悬浮金属体、绝缘子沿面等3种GIS典型绝缘缺陷,并组建特高频检波信号采集系统;然后,通过试验获取特高频(UHF)信号,统计生成相位相关脉冲序列(PRPS)谱图、相位角差(∆φi+1-∆φi)谱图;最后,分析3种缺陷相位特征谱图的差异及其产生机理。研究结果表明:尖端放电特高频信号主要出现在振荡电压的上升沿,其相位角在90~190°区间;悬浮放电与沿面放电的特高频信号出现在上升沿和下降沿;与尖端放电、悬浮放电不同的是,在∆φi+1-∆φi谱图中沿面放电特高频信号的分布在0~45°区间。此结论可作为负极性振荡型雷电冲击电压下GIS局部放电诊断的依据。 展开更多
关键词 振荡型雷电冲击电压 GIS 局部放电 特高频 检波 相位特征
下载PDF
基于Simulink的雷电冲击高压试验激励建模仿真分析 被引量:2
15
作者 闫红强 王关平 +4 位作者 孙伟 杨婉霞 杨森 雒琦 任辉 《黑龙江工业学院学报(综合版)》 2021年第6期62-67,共6页
随着电力系统电压等级的逐步升高,气体绝缘全封闭组合电器(Gas Insulated Substation,GIS)等高压电力设备的应用愈加广泛,为降低设备的安全隐患,确保设备的绝缘性能,GIS等高压设备在交付前均要进行耐压与绝缘试验,雷电冲击高压试验是设... 随着电力系统电压等级的逐步升高,气体绝缘全封闭组合电器(Gas Insulated Substation,GIS)等高压电力设备的应用愈加广泛,为降低设备的安全隐患,确保设备的绝缘性能,GIS等高压设备在交付前均要进行耐压与绝缘试验,雷电冲击高压试验是设备交接试验项目之一,雷电冲击高压试验激励建模仿真对雷电冲击高压试验至关重要。基于Simulink构建雷电冲击高压试验激励仿真模型,设置主要模块相关参数,计算冲击电压峰值、波前时间及半峰值时间,进而生成一个完整的标准冲击电压波形,为后续特超高压系统开展相关试验提供技术支持,有一定的借鉴作用和指导意义。 展开更多
关键词 雷电冲击 SIMUliNK 系统模型 高压试验
下载PDF
雷电间接效应多重脉冲组电流产生装置的设计
16
作者 刘宏伟 栾崇彪 +3 位作者 袁建强 肖金水 黄宇鹏 王凌云 《强激光与粒子束》 CAS CSCD 北大核心 2024年第2期1-7,共7页
针对雷电间接效应多重脉冲组电流模拟需求,完成了雷电间接效应多重脉冲组模拟源的设计,采用20个Crowbar电路支路,通过分时放电的方式实现1个脉冲串内多脉冲输出需求,每个支路可以实现最小间隔30 ms的重复频率放电,从而实现3个脉冲串的... 针对雷电间接效应多重脉冲组电流模拟需求,完成了雷电间接效应多重脉冲组模拟源的设计,采用20个Crowbar电路支路,通过分时放电的方式实现1个脉冲串内多脉冲输出需求,每个支路可以实现最小间隔30 ms的重复频率放电,从而实现3个脉冲串的输出需求。对放电支路的参数进行了详细设计,分析了电容、波尾电路电感、波尾电路电阻参数变化对输出特性的影响。分析了采用并联大电容实现放电电容重复频率快速充电的可行性,完成了装置的初步结构设计并结合装置结构简要分析了电路模拟参数设置的合理性。该装置建成后,可为电子、电气设备等开展测试提供技术支持。 展开更多
关键词 雷电间接效应 多重脉冲组(H波) 雷电模拟源 冲击电流发生器
下载PDF
高原地区隧道净空绝缘间隙修正
17
作者 蒋兴良 胡松林 +3 位作者 杨国林 李雨泰 张志劲 胡建林 《高电压技术》 EI CAS CSCD 北大核心 2024年第8期3589-3597,共9页
高原地区雷害频繁,电气外绝缘性能降低。修建高原铁路隧道需要对隧道净空绝缘间隙进行修正,其中隧道-架空接触网气隙间距是确定隧道净空间隙的重要依据,雷电冲击放电电压是确定该气隙最小间距的控制因素。国内外现有高海拔修正系列标准... 高原地区雷害频繁,电气外绝缘性能降低。修建高原铁路隧道需要对隧道净空绝缘间隙进行修正,其中隧道-架空接触网气隙间距是确定隧道净空间隙的重要依据,雷电冲击放电电压是确定该气隙最小间距的控制因素。国内外现有高海拔修正系列标准均不适用于3000 m以上地区,考虑放电基本特性和原理,在人工气候实验室搭建铁路隧道的典型结构,并模拟高原地区气候特点,研究300~700 mm 5个短间隙在243~4000 m 5个海拔条件下的正、负极性雷电冲击放电特性。基于大气实际参数提出了3种隧道净空绝缘间隙修正方法,建议在2、3、4 km海拔处分别按照340、390、440 mm进行隧道-架空接触网绝缘间隙修正,从而确定最小隧道净空高度。该方法可为高海拔地区铁路的电气化设计和改造提供指导,具有工程应用意义。 展开更多
关键词 高原地区 隧道净空 空气绝缘间隙 雷电冲击放电 修正方法
下载PDF
1200 kV雷电冲击电压标准测量系统 被引量:1
18
作者 王凯雨 赵伟 +2 位作者 李传生 蔡晋辉 张煌辉 《计量学报》 CSCD 北大核心 2024年第1期89-96,共8页
目前,冲击电压测量系统溯源所需的国家计量标准系统额定电压只有700 kV,无法满足3500 kV及以上的特高压电器的溯源需求。对研制的1200 kV电阻分压器进行结构分析,并对建立的1200 kV冲击电压测量系统进行性能测试及改进,在700 kV电压范... 目前,冲击电压测量系统溯源所需的国家计量标准系统额定电压只有700 kV,无法满足3500 kV及以上的特高压电器的溯源需求。对研制的1200 kV电阻分压器进行结构分析,并对建立的1200 kV冲击电压测量系统进行性能测试及改进,在700 kV电压范围内与已有的700 kV冲击电压国家标准测量系统进行比对校准,在700 kV至1200 kV电压范围进行线性度实验。对1200 kV标准冲击电压测量系统进行了不确定度评定,评定结果表明研制的1200 kV雷电冲击电压标准测量系统的试验电压、波前时间、半峰值时间的测量误差均在国际标准IEC 60060及国家标准GB/T 16927允许范围内,将我国的冲击电压国家标准测量系统额定电压等级提高至1200 kV。 展开更多
关键词 冲击电压测量 特高压电器 不确定度评定 计量标准 雷电冲击 比对校准
下载PDF
干燥空气绝缘开关柜中应用的固封极柱绝缘结构设计及优化 被引量:1
19
作者 李龙江 吴小钊 李俊豪 《高压电器》 CAS CSCD 北大核心 2024年第2期94-101,共8页
为了实现气体绝缘开关柜的绝缘介质由SF6向干燥空气等环保型气体转变,开发一种结构小型化、绝缘水平满足要求的干燥空气绝缘开关柜中使用的固封极柱是亟需解决的问题。文中分析了40.5 kV SF6固封极柱置于干燥空气绝缘开关柜中的相间及... 为了实现气体绝缘开关柜的绝缘介质由SF6向干燥空气等环保型气体转变,开发一种结构小型化、绝缘水平满足要求的干燥空气绝缘开关柜中使用的固封极柱是亟需解决的问题。文中分析了40.5 kV SF6固封极柱置于干燥空气绝缘开关柜中的相间及对地电场分布,结果显示灭弧室动、静端盖板以及绝缘拉杆附近的气—固沿面电场严重超标,易造成沿面闪络。依据气—固复合绝缘理论,采取增加均压屏蔽网、改进绝缘壳体外观结构、重新设计绝缘拉杆等措施进行电场优化。通过仿真分析,优化设计后的固封极柱灭弧室端盖附近沿面最大场强由3.4 kV/mm降至2.03 kV/mm,绝缘拉杆沿面最大场强由4.1 kV/mm降至1.7 kV/mm。对优化前后的固封极柱进行了局部放电和雷电冲击耐压试验,局部放电试验的起弧电压由35 kV提升到62 kV,雷电冲击耐压试验的峰值耐受电压由145 kV提升到218 kV,证明了优化方案的可行性,为后续40.5 kV及更高电压等级的类似固封极柱的研发及优化提供了有关参考。 展开更多
关键词 干燥空气绝缘 固封极柱 仿真分析 沿面电场 均压屏蔽 结构优化 局部放电 雷电冲击
下载PDF
触发闪电环境下地网冲击接地电阻特征分析
20
作者 张鹃 王孝波 +1 位作者 颜旭 陈绍东 《热带气象学报》 CSCD 北大核心 2024年第2期208-216,共9页
基于触发闪电技术,研究了2019年夏季8次触发闪电44次回击、5次初始连续电流脉冲(ICCP)和24次M分量对冲击接地电阻的影响,探索了冲击接地电阻随雷电流注入的动态变化规律。结果发现:闪电放电ICCP、M分量和回击过程冲击接地电阻均小于工... 基于触发闪电技术,研究了2019年夏季8次触发闪电44次回击、5次初始连续电流脉冲(ICCP)和24次M分量对冲击接地电阻的影响,探索了冲击接地电阻随雷电流注入的动态变化规律。结果发现:闪电放电ICCP、M分量和回击过程冲击接地电阻均小于工频接地电阻,ICCP和叠加在回击回落之后连续电流上的M分量冲击接地电阻略大于回击过程,平均值分别为11.2Ω和10.8Ω。叠加在回击下降沿上的M分量冲击接地电阻平均值7.8Ω,明显小于回击过程,最小值可达2.4Ω。ICCP和M分量冲击接地电阻随电流增加而减小,回击过程与电流峰值没有明显的相关性。叠加在回击下降沿上的M分量冲击接地电阻随雷电流峰值、背景电流值的增加呈指数衰减关系,还与之前回击电流峰值成一定的反比例关系。随着闪电回击电流的注入,冲击接地电阻呈现动态变化过程,小电流在回击峰值下降后出现一个缓慢增长的过程,大电流在回击峰值下降后出现一个快速下降的过程。闪电不同物理过程火花和电感效应的作用是不同的,两者共同作用决定了土壤的电离程度,从而决定了冲击接地电阻的大小和变化。 展开更多
关键词 人工触发闪电 回击 初始连续电流脉冲 M分量 冲击接地电阻
下载PDF
上一页 1 2 27 下一页 到第
使用帮助 返回顶部