The atomistic Green’s function method is improved to compute the polarization resolved phonon transport in a multiterminal system. Based on the recent developments in literature, the algorithm is simplified. The comp...The atomistic Green’s function method is improved to compute the polarization resolved phonon transport in a multiterminal system. Based on the recent developments in literature, the algorithm is simplified. The complex phonon band structure of a semi-infinite periodic terminal is obtained by the generalized eigenvalue equation. Then both the surface Green’s function and phonon group velocity in the terminal are determined from the wave modes propagating away from the scattering region along the terminal. With these key ingredients, the individual phonon mode transmittance between the terminals can be calculated. The feasibility and validity of the method are demonstrated by the chain example compared with the wave packet method, and an example of graphene nanojunction with three terminals.展开更多
The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power thr...The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power through overhead lines,HCBs are required to have reclosing capability due to the high fault probability and the fact that most of the faults are temporary faults.To avoid the secondary fault strike and equipment damage that may be caused by the reclosing of the HCB when the permanent fault occurs,an adaptive reclosing scheme based on traveling wave injection is proposed in this paper.The scheme injects traveling wave signal into the fault dc line through the additionally configured auxiliary discharge branch in the HCB,and then uses the reflection characteristic of the traveling wave signal on the dc line to identify temporary and permanent faults,to be able to realize fast reclosing when the temporary fault occurs and reliably avoid reclosing after the permanent fault occurs.The test results in the simulation model of the four-terminal dc grid show that the proposed adaptive reclosing scheme can quickly and reliably identify temporary and permanent faults,greatly shorten the power outage time of temporary faults.In addition,it has the advantages of easiness to implement,high reliability,robustness to high-resistance fault and no dead zone,etc.展开更多
Multi-terminal hybrid high-voltage direct current(HVDC)systems have been developed quickly in recent years in power transmission area.However,for voltage-source converter(VSC)stations in hybrid HVDC systems,no direct ...Multi-terminal hybrid high-voltage direct current(HVDC)systems have been developed quickly in recent years in power transmission area.However,for voltage-source converter(VSC)stations in hybrid HVDC systems,no direct current(DC)filters are required.In addition,the DC reactor is also not installed at the line end because the DC fault can be limited by the converter itself.This means that the boundary element at the line end is absent,and the single-ended protections used in line commutated converter(LCC)based HVDC(LCC-HVDC)systems or VSC-HVDC systems cannot distinguish the fault line in multi-terminal hybrid HVDC systems.This paper proposes a novel singleended DC protection strategy suitable for the multi-terminal hybrid HVDC system,which mainly applies the transient information and active injection concept to detect and distinguish the fault line.Compared with the single-ended protections used in LCC-HVDC and VSC-HVDC systems,the proposed protection strategy is not dependent on the line boundary element and is thus suitable for the multiterminal hybrid HVDC system.The corresponding simulation cases based on power systems computer aided design(PSCAD)/electromagnetic transients including DC(EMTDC)are carried out to verify the superiority of the proposed protection.展开更多
Transport properties in a multi-terminal regular polygonal quantum ring with Rashba spin-orbit coupling (SOC) are investigated analytically using quantum networks and the transport matrix metLod. The results show th...Transport properties in a multi-terminal regular polygonal quantum ring with Rashba spin-orbit coupling (SOC) are investigated analytically using quantum networks and the transport matrix metLod. The results show that conduc- tances remain at exactly the same values when the output leads are located at axisymmetric positions. However, for the nonaxisymmetrical case, there is a phase difference between the upper and lower arm, which leads to zero conductances appearing periodically. An isotropy of the conductance is destroyed by the Rashba SOC effect in the axisymmetric case. In addition, the position of zero conductance is regulated with the strength of the Rashba SOC.展开更多
Security constrained multi area multi objective dynamic economic dispatch (SCMAMODED) with renewable energy (RE) and all the possible MTDC stability constraints is formulated for the first time. The stability merits o...Security constrained multi area multi objective dynamic economic dispatch (SCMAMODED) with renewable energy (RE) and all the possible MTDC stability constraints is formulated for the first time. The stability merits of multi terminal DC (MTDC) tie lines as compared to the traditional HVAC forms the main objective of this paper. Probabilistic load flow (PLF) is applied to determine the system parameters while the uncertainties are modelled using Scenario Based Method (SBM). The simulation results reveal that with the use of MTDC tie lines, the frequency and voltage stability in the MAMODED with renewable energy sources (RES) are enhanced while keeping the MTDC power exchange interface nodes at secure levels.展开更多
Reservoir computing(RC)is an energy-efficient computational framework with low training cost and high efficiency in processing spatiotemporal information.The state-of-the-art fully memristor-based hardware RC system s...Reservoir computing(RC)is an energy-efficient computational framework with low training cost and high efficiency in processing spatiotemporal information.The state-of-the-art fully memristor-based hardware RC system suffers from bottlenecks in the computation efficiencies and accuracy due to the limited temporal tunability in the volatile memristor for the reservoir layer and the nonlinearity in the nonvolatile memristor for the readout layer.Additionally,integrating different types of memristors brings fabrication and integration complexities.To overcome the challenges,a multifunctional multi-terminal electrolyte-gated transistor(MTEGT)that combines both electrostatic and electrochemical doping mechanisms is proposed in this work,integrating both widely tunable volatile dynamics with high temporal tunable range of 10^(2) and nonvolatile memory properties with high long-term potentiation/long-term depression(LTP/LTD)linearity into a single device.An ion-controlled physical RC system fully implemented with only one type of MTEGT is constructed for image recognition using the volatile dynamics for the reservoir and nonvolatility for the readout layer.Moreover,an ultralow normalized mean square error of 0.002 is achieved in a time series prediction task.It is believed that the MTEGT would underlie next-generation neuromorphic computing systems with low hardware costs and high computational performance.展开更多
A fault identification scheme for protection and adaptive reclosing is proposed for a hybrid multi-terminal HVDC system to increase the reliability of fault isolation and reclosing.By analyzing the"zero passing&q...A fault identification scheme for protection and adaptive reclosing is proposed for a hybrid multi-terminal HVDC system to increase the reliability of fault isolation and reclosing.By analyzing the"zero passing"characteristic of current at the local end during the converter capacitor discharge stage,the fault identification scheme is proposed.The distributed parameter-based fault location equation,which incorporates fault distance and fault impedance,is developed with the injection signal and the distributed parameter model during the adaptive reclosing stage.The fault distance is determined using a trust region reflection algorithm to identify the permanent fault,and a fault iden-tification scheme for adaptive reclosing is developed.Simulation results show that the proposed scheme is suitable for long-distance transmission lines with strong anti-fault impedance and anti-interference performance.Also,it is less affected by communication delay and DC boundary strength than existing methods.展开更多
This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The sche...This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The scheme overcomes existing detection difficulties in the protection of long transmission lines resulting from high grounding resistance and attenuation,and also avoids the sophisticated process of threshold value selection.The high-frequency components in the measured voltage extracted by a wavelet transform and the amplitude of the zero-mode set of the positive-sequence voltage are the inputs to a trained SVM.The output of the SVM determines the fault type.A model of a four-terminal DC power grid with overhead transmission lines is built in PSCAD/EMTDC.Simulation results of EMTDC confirm that the proposed scheme achieves 100%accuracy in detecting short-circuit faults with high resistance on long transmission lines.The proposed scheme eliminates mal-operation of DC circuit breakers when faced with power order changes or AC-side faults.Its robustness and time delay are also assessed and shown to have no perceptible effect on the speed and accuracy of the detection scheme,thus ensuring its reliability and stability.展开更多
This paper presents a framework of a multi-terminal HVDC transmission system and its multi-functional control strategy.The framework possesses the basic characteristics of the DC-grid and is suitable in integrating di...This paper presents a framework of a multi-terminal HVDC transmission system and its multi-functional control strategy.The framework possesses the basic characteristics of the DC-grid and is suitable in integrating distributed power sources.The paper proposes the first architecture for a multiterminal HVDC transmission system using the VSC technology.Its control strategy offers various functionalities that include controls for operation mode,start-up and shutdown,DC voltage,and station online re-connecting,which are significantly different from the control of point-to-point VSC-HVDC systems.The framework has not only been evaluated in real-time simulation studies,but has also been implemented onsite for the first time via the China Southern Grid's Nan'ao Multi-terminal VSCHVDC(VSC-MTDC)project.This paper gives a brief review of the current research and engineering achievements in this field,which includes four aspects:the architecture of the VSCMTDC system,the structure of the control and protection system,simulation verification tests setting,and the results of real-time hardware in hardware in loop(HIL)simulation studies and onsite tests.展开更多
Multi-terminal direct current(MTDC)grids provide the possibility of meshed interconnections between regional power systems and various renewable energy resources to boost supply reliability and economy.The modular mul...Multi-terminal direct current(MTDC)grids provide the possibility of meshed interconnections between regional power systems and various renewable energy resources to boost supply reliability and economy.The modular multilevel converter(MMC)has become the basic building block for MTDC and DC grids due to its salient features,i.e.,modularity and scalability.Therefore,the MMC-based MTDC systems should be pervasively embedded into the present power system to improve system performance.However,several technical challenges hamper their practical applications and deployment,including modeling,control,and protection of the MMC-MTDC grids.This paper presents a comprehensive investigation and reference in modeling,control,and protection of the MMC-MTDC grids.A general overview of state-of-the-art modeling techniques of the MMC along with their performance in simulation analysis for MTDC applications is provided.A review of control strategies of the MMC-MTDC grids which provide AC system support is presented.State-of-the art protection techniques of the MMCMTDC systems are also investigated.Finally,the associated research challenges and trends are highlighted.展开更多
A hierarchical control scheme is proposed for optimal power flow control to minimize loss in a hybrid multiterminal HVDC(hybrid-MTDC)transmission system.In this scheme,the lower level is the droop control,which enable...A hierarchical control scheme is proposed for optimal power flow control to minimize loss in a hybrid multiterminal HVDC(hybrid-MTDC)transmission system.In this scheme,the lower level is the droop control,which enables fast response to power fluctuation and ensures a stable DC voltage,and the upper level is power flow optimization control,which minimizes the losses during the operation of hybrid-MTDC and solves the contradiction between minimizing losses and preventing commutation failure.A 6-terminal hybrid-MTDC is also designed and simulated in PSCAD according to the potential demand of power transmission and wind farms integration in China to verify the proposed control strategy.First,the steady state analysis is conducted and then compared with simulation results.The analysis shows that the proposed control scheme achieves the desired minimum losses while at the same time satisfying system constraints.The proposed control scheme also guarantees that the hybrid-MTDC not only has a good dynamic response,but also remains stable during communication failure.展开更多
For the planning,operation and control of multiterminal voltage source converter(VSC)based high-voltage direct current(HVDC)(VSC-MTDC)systems,an accurate power flow formulation is a key starting point.Conventional pow...For the planning,operation and control of multiterminal voltage source converter(VSC)based high-voltage direct current(HVDC)(VSC-MTDC)systems,an accurate power flow formulation is a key starting point.Conventional power flow formulations assume the constant frequencies for all asynchronous AC systems.Therefore,a new feature about the complex coupling relations between AC frequencies,DC voltages and the exchanged power via VSC stations cannot be characterized if VSC-MTDC systems are required to provide cross-regional frequency responses.To address this issue,this paper proposes a comprehensive frequency-dependent power flow formulation.The proposed approach takes the frequencies of asynchronous AC systems as explicit variables,and investigates the novel bus models of the interlinking buses of VSC stations.The proposed approach accommodates different operation modes and frequency droop strategies of VSC stations,and considers the power losses of VSC stations.The effectiveness and generality of the developed approach are validated by a 6-terminal VSC-HVDC test system.The test system presents the characteristics of the coexistence of numerous VSC operation modes,the absence of slack buses in both AC and DC subsystems,and diversified grid configurations such as point-to-point integration of renewable energy sources and one AC system integrated with multiple VSC stations.展开更多
This paper is concerned with power reduction control which is used to avoid DC over-voltage for multiterminal HVDC transmission of offshore wind power.Voltages and frequencies of offshore AC wind farm networks are use...This paper is concerned with power reduction control which is used to avoid DC over-voltage for multiterminal HVDC transmission of offshore wind power.Voltages and frequencies of offshore AC wind farm networks are used for transmitting control signals for the power reduction control.These methods do not require fast communication.Power reduction sharing among the offshore wind farms using the different control signals is analysed.The control systems are also compared against the DC chopper method to prevent a DC overvoltage.Simulation and experiments are carried out to evaluate the control systems.展开更多
Multi-terminal high-voltage DC(MTDC)technology is a promising way to transmit large amounts of offshore wind power to the main grids.This paper proposes a hybrid MTDC scheme to integrate several offshore wind farms in...Multi-terminal high-voltage DC(MTDC)technology is a promising way to transmit large amounts of offshore wind power to the main grids.This paper proposes a hybrid MTDC scheme to integrate several offshore wind farms into the onshore power grids at different locations.A hybrid four-terminal HVDC system comprising two onshore line commutated converters(LCCs)and two voltage source converters(VSCs)connecting an offshore wind farm is constructed in PSCAD/EMTDC.A coordination control scheme based on the VSCs’AC voltage control and the LCCs’DC voltage droop control is designed to ensure smooth system operation and proper power sharing between onshore AC grids.The operational characteristics of the system are analyzed.In addition,a black start-up method without any auxiliary power supply for the VSCs is proposed.The transmission scheme is tested through simulations under various conditions,including start-up,wind speed variation,and the disconnection of one VSC or of one LCC.展开更多
The multi-terminal VSC-HVDC grid is believed to be widely applied in the future power system. The dc line protection is the key technique for operation security and power supply reliability of the dc grid. In this pap...The multi-terminal VSC-HVDC grid is believed to be widely applied in the future power system. The dc line protection is the key technique for operation security and power supply reliability of the dc grid. In this paper, the single-ended protections, namely, the traveling-wave based protection and transient-variable based protection, as well as the pilot protections, mainly including the directional pilot protection and current differential protection, are discussed in detail. With the analyzed protections, the effective main and back-up protection strategy can be configured for the dc line in multi-terminal VSC-HVDC grid.展开更多
A hybrid of line commutated converters(LCCs)and modular multi-level converters(MMCs)can provide the advantages of both the technologies.However,the commutation failure still exists if the LCC operates as an inverter i...A hybrid of line commutated converters(LCCs)and modular multi-level converters(MMCs)can provide the advantages of both the technologies.However,the commutation failure still exists if the LCC operates as an inverter in a hybrid LCC/MMC system.In this paper,the system behavior during a commutation failure is investigated.Both halfbridge and full-bridge MMCs are considered.Control strategies are examined through simulations conducted in PSCAD/EMTDC.Additionally,commutation failure protection strategies for multi-terminal hybrid LCC/MMC systems with AC and DC circuit breakers are studied.This paper can contribute to the protection design of future hybrid LCC/MMC systems against commutation failures.展开更多
Multi-terminal voltage sourced converter(VSC)-based high voltage direct current (HVDC) system composes of a number of VSCs connected to an HVDC grid (or dc grid).The dc grid is often configured by cable interconnectio...Multi-terminal voltage sourced converter(VSC)-based high voltage direct current (HVDC) system composes of a number of VSCs connected to an HVDC grid (or dc grid).The dc grid is often configured by cable interconnections between converter stations,thus imposing resonance issues affecting harmonic interaction in the system.Based on the harmonic transfer characteristics of VSC and HVDC systems,the appearance and the interaction of inter-harmonics in the multi-terminal VSC-based HVDC system are analyzed.Simulation models are built and implemented using SimPowerSystems in MATLAB.The simulation results show that,a series of inter-harmonics are produced and tend to be dominant in low-frequency range.Especially in the dc grid,the inter-harmonic transfer can be magnified due to inter-harmonic resonances.The complex resonance issues in the dc grid are investigated in combination with interaction through the VSC,it is beneficial to harmonic filter designs as well as other harmonic mitigation methods.展开更多
Controllability of DC current/power flow is essentialin multi-terminal HVDC (MTDC) grids, particularly for theMTDC grids in a meshed topology. In this paper, consideringmeshed MTDC (M2TDC) grids with the installation ...Controllability of DC current/power flow is essentialin multi-terminal HVDC (MTDC) grids, particularly for theMTDC grids in a meshed topology. In this paper, consideringmeshed MTDC (M2TDC) grids with the installation of twoline/multi-lineDC current flow controllers (CFCs), a small-signalmodel of the DC CFCs integrated M2TDC grids is derived,studying the impact of the power losses of the DC CFC andtheir influence on the analysis of energy exchanges. The systemstability analysis is analysed using the Nyquist diagram, which ismore suitable for analyzing complex nonlinear systems with morecompact and reliable indicators of stability in comparison withgain/phase margins shown in the Bode diagram. In addition, aselection method of the interconnected capacitor of the DC CFCis proposed under different operating conditions. The impact ofthe switching frequencies of the DC CFC on the control ranges ofthe DC current flows is analyzed. The effectiveness of the Nyquistanalysis and the capacitance selection method is verified bysimulation studies using PSCAD/EMTDC. The obtained control ranges of the DC CFC with different switching frequenciesand capacitances would be useful for practical engineeringapplications.展开更多
In order to overcome the problems of power flow control and fault current limiting in multi-terminal high voltage direct current(MTDC)grids,this paper proposes a modular multi-terminal DC power flow controller(MM-DCPF...In order to overcome the problems of power flow control and fault current limiting in multi-terminal high voltage direct current(MTDC)grids,this paper proposes a modular multi-terminal DC power flow controller(MM-DCPFC)with fault current limiting function.The topology structure,operation principle,and equivalent circuit of MM-DCPFC are introduced,and such a structure has the advantages of modularity and scalability.The power balance mechanism is studied and a hierarchical power balance control strategy is proposed.The results show that MM-DCPFC can achieve internal power exchange,which avoids the use of external power supply.The fault characteristics of MM-DCPFC are analyzed,fault current limiting and self-protection methods are proposed,and the factors affecting the current limiting capability are studied.The simulation models are established in PLECS,and the simulation results verify the effectiveness of MM-DCPFC in power flow control,fault current limiting,and scalability.In addition,a prototype is developed to validate the function and control method of MM-DCPFC.展开更多
This paper puts forward a new practical voltage source converter(VSC)based AC-DC converter model suitable for conducting power flow assessment of multi-terminal VSCbased high-voltage direct current(VSC-MTDC)systems.Th...This paper puts forward a new practical voltage source converter(VSC)based AC-DC converter model suitable for conducting power flow assessment of multi-terminal VSCbased high-voltage direct current(VSC-MTDC)systems.The model uses an advanced method to handle the operational limits and control modes of VSCs into the power flow formulation.The new model is incorporated into a unified framework encompassing AC and DC power grids and is solved by using the Newton-Raphson method to enable quadratically convergent iterative solutions.The use of complementarity constraints,together with the Fischer-Burmeister function,is proposed to enable the seamless incorporation of operational control modes of VSC and automatic enforcement of any converter’s operational limits that become violated during the iterative solution process.Thus,a dedicated process for checking limits is no longer required.Furthermore,all existing relationships between the VSC control laws and their operational limits are considered directly during the solution of the power flow problem.The applicability of the new model is demonstrated with numerical examples using various multi-terminal AC-DC transmission networks,one of which is a utility-sized power system.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant No.51376094)Jiangsu Overseas Visiting Scholar Program for University Prominent Young&Middle-aged Teachers and Presidents,China
文摘The atomistic Green’s function method is improved to compute the polarization resolved phonon transport in a multiterminal system. Based on the recent developments in literature, the algorithm is simplified. The complex phonon band structure of a semi-infinite periodic terminal is obtained by the generalized eigenvalue equation. Then both the surface Green’s function and phonon group velocity in the terminal are determined from the wave modes propagating away from the scattering region along the terminal. With these key ingredients, the individual phonon mode transmittance between the terminals can be calculated. The feasibility and validity of the method are demonstrated by the chain example compared with the wave packet method, and an example of graphene nanojunction with three terminals.
基金supported by the Science and Technology Project of State Grid Corporation of China under Grant 520201210025。
文摘The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power through overhead lines,HCBs are required to have reclosing capability due to the high fault probability and the fact that most of the faults are temporary faults.To avoid the secondary fault strike and equipment damage that may be caused by the reclosing of the HCB when the permanent fault occurs,an adaptive reclosing scheme based on traveling wave injection is proposed in this paper.The scheme injects traveling wave signal into the fault dc line through the additionally configured auxiliary discharge branch in the HCB,and then uses the reflection characteristic of the traveling wave signal on the dc line to identify temporary and permanent faults,to be able to realize fast reclosing when the temporary fault occurs and reliably avoid reclosing after the permanent fault occurs.The test results in the simulation model of the four-terminal dc grid show that the proposed adaptive reclosing scheme can quickly and reliably identify temporary and permanent faults,greatly shorten the power outage time of temporary faults.In addition,it has the advantages of easiness to implement,high reliability,robustness to high-resistance fault and no dead zone,etc.
文摘Multi-terminal hybrid high-voltage direct current(HVDC)systems have been developed quickly in recent years in power transmission area.However,for voltage-source converter(VSC)stations in hybrid HVDC systems,no direct current(DC)filters are required.In addition,the DC reactor is also not installed at the line end because the DC fault can be limited by the converter itself.This means that the boundary element at the line end is absent,and the single-ended protections used in line commutated converter(LCC)based HVDC(LCC-HVDC)systems or VSC-HVDC systems cannot distinguish the fault line in multi-terminal hybrid HVDC systems.This paper proposes a novel singleended DC protection strategy suitable for the multi-terminal hybrid HVDC system,which mainly applies the transient information and active injection concept to detect and distinguish the fault line.Compared with the single-ended protections used in LCC-HVDC and VSC-HVDC systems,the proposed protection strategy is not dependent on the line boundary element and is thus suitable for the multiterminal hybrid HVDC system.The corresponding simulation cases based on power systems computer aided design(PSCAD)/electromagnetic transients including DC(EMTDC)are carried out to verify the superiority of the proposed protection.
基金Project supported by the National Natural Science Foundation of China(Grant No.61176089)Hebei Provincial Natural Science Foundation,China(Grant No.A2011205092)
文摘Transport properties in a multi-terminal regular polygonal quantum ring with Rashba spin-orbit coupling (SOC) are investigated analytically using quantum networks and the transport matrix metLod. The results show that conduc- tances remain at exactly the same values when the output leads are located at axisymmetric positions. However, for the nonaxisymmetrical case, there is a phase difference between the upper and lower arm, which leads to zero conductances appearing periodically. An isotropy of the conductance is destroyed by the Rashba SOC effect in the axisymmetric case. In addition, the position of zero conductance is regulated with the strength of the Rashba SOC.
文摘Security constrained multi area multi objective dynamic economic dispatch (SCMAMODED) with renewable energy (RE) and all the possible MTDC stability constraints is formulated for the first time. The stability merits of multi terminal DC (MTDC) tie lines as compared to the traditional HVAC forms the main objective of this paper. Probabilistic load flow (PLF) is applied to determine the system parameters while the uncertainties are modelled using Scenario Based Method (SBM). The simulation results reveal that with the use of MTDC tie lines, the frequency and voltage stability in the MAMODED with renewable energy sources (RES) are enhanced while keeping the MTDC power exchange interface nodes at secure levels.
基金supported by Guangdong Basic and Applied Basic Research Foundation(No.2022A1515011272)the National Natural Science Foundation of China(Nos.61904208,62104091,52273246)+2 种基金Guangdong Natural Science Foundation(No.2022A1515011064)Young Innovative Talent Project Research Program(No.2021KQNCX077)Shenzhen Science and Technology Program(Nos.JCYJ20190807155411277,JCYJ20220530115204009).
文摘Reservoir computing(RC)is an energy-efficient computational framework with low training cost and high efficiency in processing spatiotemporal information.The state-of-the-art fully memristor-based hardware RC system suffers from bottlenecks in the computation efficiencies and accuracy due to the limited temporal tunability in the volatile memristor for the reservoir layer and the nonlinearity in the nonvolatile memristor for the readout layer.Additionally,integrating different types of memristors brings fabrication and integration complexities.To overcome the challenges,a multifunctional multi-terminal electrolyte-gated transistor(MTEGT)that combines both electrostatic and electrochemical doping mechanisms is proposed in this work,integrating both widely tunable volatile dynamics with high temporal tunable range of 10^(2) and nonvolatile memory properties with high long-term potentiation/long-term depression(LTP/LTD)linearity into a single device.An ion-controlled physical RC system fully implemented with only one type of MTEGT is constructed for image recognition using the volatile dynamics for the reservoir and nonvolatility for the readout layer.Moreover,an ultralow normalized mean square error of 0.002 is achieved in a time series prediction task.It is believed that the MTEGT would underlie next-generation neuromorphic computing systems with low hardware costs and high computational performance.
基金supported by the Technology Projects of Southern Power Grid Electric Power Research Institute of China(SEPRI-K22B055)National Nature Science Foundation project(2021YFB1507000,2021YFB1507004)the Natural Science Foundation of Xinjiang Uygur Autonomous Region(2022D01C662).
文摘A fault identification scheme for protection and adaptive reclosing is proposed for a hybrid multi-terminal HVDC system to increase the reliability of fault isolation and reclosing.By analyzing the"zero passing"characteristic of current at the local end during the converter capacitor discharge stage,the fault identification scheme is proposed.The distributed parameter-based fault location equation,which incorporates fault distance and fault impedance,is developed with the injection signal and the distributed parameter model during the adaptive reclosing stage.The fault distance is determined using a trust region reflection algorithm to identify the permanent fault,and a fault iden-tification scheme for adaptive reclosing is developed.Simulation results show that the proposed scheme is suitable for long-distance transmission lines with strong anti-fault impedance and anti-interference performance.Also,it is less affected by communication delay and DC boundary strength than existing methods.
文摘This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The scheme overcomes existing detection difficulties in the protection of long transmission lines resulting from high grounding resistance and attenuation,and also avoids the sophisticated process of threshold value selection.The high-frequency components in the measured voltage extracted by a wavelet transform and the amplitude of the zero-mode set of the positive-sequence voltage are the inputs to a trained SVM.The output of the SVM determines the fault type.A model of a four-terminal DC power grid with overhead transmission lines is built in PSCAD/EMTDC.Simulation results of EMTDC confirm that the proposed scheme achieves 100%accuracy in detecting short-circuit faults with high resistance on long transmission lines.The proposed scheme eliminates mal-operation of DC circuit breakers when faced with power order changes or AC-side faults.Its robustness and time delay are also assessed and shown to have no perceptible effect on the speed and accuracy of the detection scheme,thus ensuring its reliability and stability.
基金supported by the 863 National High Technology Research and Development Program of China(2011AA05AI02)China Southern Power Grid Company.
文摘This paper presents a framework of a multi-terminal HVDC transmission system and its multi-functional control strategy.The framework possesses the basic characteristics of the DC-grid and is suitable in integrating distributed power sources.The paper proposes the first architecture for a multiterminal HVDC transmission system using the VSC technology.Its control strategy offers various functionalities that include controls for operation mode,start-up and shutdown,DC voltage,and station online re-connecting,which are significantly different from the control of point-to-point VSC-HVDC systems.The framework has not only been evaluated in real-time simulation studies,but has also been implemented onsite for the first time via the China Southern Grid's Nan'ao Multi-terminal VSCHVDC(VSC-MTDC)project.This paper gives a brief review of the current research and engineering achievements in this field,which includes four aspects:the architecture of the VSCMTDC system,the structure of the control and protection system,simulation verification tests setting,and the results of real-time hardware in hardware in loop(HIL)simulation studies and onsite tests.
基金funded by SGCC Science and Technology Program under project Research on Electromagnetic Transient Simulation Technology for Large-scale MMC-HVDC Systems.
文摘Multi-terminal direct current(MTDC)grids provide the possibility of meshed interconnections between regional power systems and various renewable energy resources to boost supply reliability and economy.The modular multilevel converter(MMC)has become the basic building block for MTDC and DC grids due to its salient features,i.e.,modularity and scalability.Therefore,the MMC-based MTDC systems should be pervasively embedded into the present power system to improve system performance.However,several technical challenges hamper their practical applications and deployment,including modeling,control,and protection of the MMC-MTDC grids.This paper presents a comprehensive investigation and reference in modeling,control,and protection of the MMC-MTDC grids.A general overview of state-of-the-art modeling techniques of the MMC along with their performance in simulation analysis for MTDC applications is provided.A review of control strategies of the MMC-MTDC grids which provide AC system support is presented.State-of-the art protection techniques of the MMCMTDC systems are also investigated.Finally,the associated research challenges and trends are highlighted.
基金supported in part by the 111 Project of China under Grant B08013State Grid Corporation of China under Grant XT71-14-042.
文摘A hierarchical control scheme is proposed for optimal power flow control to minimize loss in a hybrid multiterminal HVDC(hybrid-MTDC)transmission system.In this scheme,the lower level is the droop control,which enables fast response to power fluctuation and ensures a stable DC voltage,and the upper level is power flow optimization control,which minimizes the losses during the operation of hybrid-MTDC and solves the contradiction between minimizing losses and preventing commutation failure.A 6-terminal hybrid-MTDC is also designed and simulated in PSCAD according to the potential demand of power transmission and wind farms integration in China to verify the proposed control strategy.First,the steady state analysis is conducted and then compared with simulation results.The analysis shows that the proposed control scheme achieves the desired minimum losses while at the same time satisfying system constraints.The proposed control scheme also guarantees that the hybrid-MTDC not only has a good dynamic response,but also remains stable during communication failure.
基金supported by the National Key Research and Development Program of China(No.2017YFB0902200)National Natural Science Foundation of China(No.U1766201)State Grid Technology Project(No.SGGSKY00FJJS1600209)。
文摘For the planning,operation and control of multiterminal voltage source converter(VSC)based high-voltage direct current(HVDC)(VSC-MTDC)systems,an accurate power flow formulation is a key starting point.Conventional power flow formulations assume the constant frequencies for all asynchronous AC systems.Therefore,a new feature about the complex coupling relations between AC frequencies,DC voltages and the exchanged power via VSC stations cannot be characterized if VSC-MTDC systems are required to provide cross-regional frequency responses.To address this issue,this paper proposes a comprehensive frequency-dependent power flow formulation.The proposed approach takes the frequencies of asynchronous AC systems as explicit variables,and investigates the novel bus models of the interlinking buses of VSC stations.The proposed approach accommodates different operation modes and frequency droop strategies of VSC stations,and considers the power losses of VSC stations.The effectiveness and generality of the developed approach are validated by a 6-terminal VSC-HVDC test system.The test system presents the characteristics of the coexistence of numerous VSC operation modes,the absence of slack buses in both AC and DC subsystems,and diversified grid configurations such as point-to-point integration of renewable energy sources and one AC system integrated with multiple VSC stations.
基金supported by the Research Councils UK,through the HubNet consortium,www.hubnet.org.uk(grant number:EP/I01363611)the Top and Tail Transformation programme,(grant number:EP/I031707/1)+1 种基金supported by the People Programme(Marie Curie Actions)of the European Union's Seventh Framework Programme FP7/2007-20131(grant number:317221,project title MEDOW)supported by the Joint Research Fund for Overseas Chinese,Hong Kong,and Macao Scientists of the National Natural Science Foundation of China(grant number:51128701).
文摘This paper is concerned with power reduction control which is used to avoid DC over-voltage for multiterminal HVDC transmission of offshore wind power.Voltages and frequencies of offshore AC wind farm networks are used for transmitting control signals for the power reduction control.These methods do not require fast communication.Power reduction sharing among the offshore wind farms using the different control signals is analysed.The control systems are also compared against the DC chopper method to prevent a DC overvoltage.Simulation and experiments are carried out to evaluate the control systems.
基金This study was supported by National Natural Science Foundation of China(No.50937002,No.51190104)National HI-Tech R&D Program of China(No.2011AA05A112).
文摘Multi-terminal high-voltage DC(MTDC)technology is a promising way to transmit large amounts of offshore wind power to the main grids.This paper proposes a hybrid MTDC scheme to integrate several offshore wind farms into the onshore power grids at different locations.A hybrid four-terminal HVDC system comprising two onshore line commutated converters(LCCs)and two voltage source converters(VSCs)connecting an offshore wind farm is constructed in PSCAD/EMTDC.A coordination control scheme based on the VSCs’AC voltage control and the LCCs’DC voltage droop control is designed to ensure smooth system operation and proper power sharing between onshore AC grids.The operational characteristics of the system are analyzed.In addition,a black start-up method without any auxiliary power supply for the VSCs is proposed.The transmission scheme is tested through simulations under various conditions,including start-up,wind speed variation,and the disconnection of one VSC or of one LCC.
基金supported by the National Natural Science Foundation of China(No.U1866205).
文摘The multi-terminal VSC-HVDC grid is believed to be widely applied in the future power system. The dc line protection is the key technique for operation security and power supply reliability of the dc grid. In this paper, the single-ended protections, namely, the traveling-wave based protection and transient-variable based protection, as well as the pilot protections, mainly including the directional pilot protection and current differential protection, are discussed in detail. With the analyzed protections, the effective main and back-up protection strategy can be configured for the dc line in multi-terminal VSC-HVDC grid.
基金supported by the Science and Technology Project of the State Grid Corporation of China,HVDC Systems/Grids for Transnational Interconnections(Project number:SGTYHT/16-JS-198).
文摘A hybrid of line commutated converters(LCCs)and modular multi-level converters(MMCs)can provide the advantages of both the technologies.However,the commutation failure still exists if the LCC operates as an inverter in a hybrid LCC/MMC system.In this paper,the system behavior during a commutation failure is investigated.Both halfbridge and full-bridge MMCs are considered.Control strategies are examined through simulations conducted in PSCAD/EMTDC.Additionally,commutation failure protection strategies for multi-terminal hybrid LCC/MMC systems with AC and DC circuit breakers are studied.This paper can contribute to the protection design of future hybrid LCC/MMC systems against commutation failures.
基金supported by"111"Project of China(No.B08013)National Natural Science Foundation of China(No.51177044)
文摘Multi-terminal voltage sourced converter(VSC)-based high voltage direct current (HVDC) system composes of a number of VSCs connected to an HVDC grid (or dc grid).The dc grid is often configured by cable interconnections between converter stations,thus imposing resonance issues affecting harmonic interaction in the system.Based on the harmonic transfer characteristics of VSC and HVDC systems,the appearance and the interaction of inter-harmonics in the multi-terminal VSC-based HVDC system are analyzed.Simulation models are built and implemented using SimPowerSystems in MATLAB.The simulation results show that,a series of inter-harmonics are produced and tend to be dominant in low-frequency range.Especially in the dc grid,the inter-harmonic transfer can be magnified due to inter-harmonic resonances.The complex resonance issues in the dc grid are investigated in combination with interaction through the VSC,it is beneficial to harmonic filter designs as well as other harmonic mitigation methods.
基金National Natural Science Foundation of China under Grant 51807091Natural Science Foundation of Jiangsu Province BK20180478+1 种基金the China Postdoctoral Science Foundation under Grant 2019M661846EPSRC under Grant EP/N032888/1.
文摘Controllability of DC current/power flow is essentialin multi-terminal HVDC (MTDC) grids, particularly for theMTDC grids in a meshed topology. In this paper, consideringmeshed MTDC (M2TDC) grids with the installation of twoline/multi-lineDC current flow controllers (CFCs), a small-signalmodel of the DC CFCs integrated M2TDC grids is derived,studying the impact of the power losses of the DC CFC andtheir influence on the analysis of energy exchanges. The systemstability analysis is analysed using the Nyquist diagram, which ismore suitable for analyzing complex nonlinear systems with morecompact and reliable indicators of stability in comparison withgain/phase margins shown in the Bode diagram. In addition, aselection method of the interconnected capacitor of the DC CFCis proposed under different operating conditions. The impact ofthe switching frequencies of the DC CFC on the control ranges ofthe DC current flows is analyzed. The effectiveness of the Nyquistanalysis and the capacitance selection method is verified bysimulation studies using PSCAD/EMTDC. The obtained control ranges of the DC CFC with different switching frequenciesand capacitances would be useful for practical engineeringapplications.
基金supported in part by National Key R&D Program of China(No.2018YFB0904600)National Natural Science Foundation of China(No.51807053)。
文摘In order to overcome the problems of power flow control and fault current limiting in multi-terminal high voltage direct current(MTDC)grids,this paper proposes a modular multi-terminal DC power flow controller(MM-DCPFC)with fault current limiting function.The topology structure,operation principle,and equivalent circuit of MM-DCPFC are introduced,and such a structure has the advantages of modularity and scalability.The power balance mechanism is studied and a hierarchical power balance control strategy is proposed.The results show that MM-DCPFC can achieve internal power exchange,which avoids the use of external power supply.The fault characteristics of MM-DCPFC are analyzed,fault current limiting and self-protection methods are proposed,and the factors affecting the current limiting capability are studied.The simulation models are established in PLECS,and the simulation results verify the effectiveness of MM-DCPFC in power flow control,fault current limiting,and scalability.In addition,a prototype is developed to validate the function and control method of MM-DCPFC.
基金supported by Fondo de Sustentabilidad Energética SENERConacyt,México(No.246949 and No.249795)。
文摘This paper puts forward a new practical voltage source converter(VSC)based AC-DC converter model suitable for conducting power flow assessment of multi-terminal VSCbased high-voltage direct current(VSC-MTDC)systems.The model uses an advanced method to handle the operational limits and control modes of VSCs into the power flow formulation.The new model is incorporated into a unified framework encompassing AC and DC power grids and is solved by using the Newton-Raphson method to enable quadratically convergent iterative solutions.The use of complementarity constraints,together with the Fischer-Burmeister function,is proposed to enable the seamless incorporation of operational control modes of VSC and automatic enforcement of any converter’s operational limits that become violated during the iterative solution process.Thus,a dedicated process for checking limits is no longer required.Furthermore,all existing relationships between the VSC control laws and their operational limits are considered directly during the solution of the power flow problem.The applicability of the new model is demonstrated with numerical examples using various multi-terminal AC-DC transmission networks,one of which is a utility-sized power system.