Hydrogen challenge mitigation stands as one of the main objectives in the management of severe accidents at Nuclear Power Plants (NPPs). Key strategies for hydrogen control include atmospheric inertization and hydroge...Hydrogen challenge mitigation stands as one of the main objectives in the management of severe accidents at Nuclear Power Plants (NPPs). Key strategies for hydrogen control include atmospheric inertization and hydrogen removal with Passive Autocatalytic Recombiners (PARs) being a commonly accepted approach. However, an examination of PAR operation specificity reveals potential inefficiencies and reliability issues in certain severe accident scenarios. Moreover, during the in-vessel stage of severe accident development, in some severe accident scenarios PARs can unexpectedly become a source of hydrogen detonation. The effectiveness of hydrogen removal systems depends on various factors, including the chosen strategies, severe accident scenarios, reactor building design, and other influencing factors. Consequently, a comprehensive hydrogen mitigation strategy must effectively incorporate a combination of strategies rather than be based on one strategy, taking into consideration the probabilistic risks and uncertainties associated with the implementation of PARs or other traditional methods. In response to these considerations, within the framework of this research it has been suggested a conceptual strategy to mitigate the hydrogen challenge during the in-vessel stage of severe accident development.展开更多
This study presents a probabilistic safety analysis(PSA)method for the external event of extreme snowfall on a floating nuclear power plant(FNPP)deployed in the Bohai Sea.We utilized the Weibull and Gumbel extreme val...This study presents a probabilistic safety analysis(PSA)method for the external event of extreme snowfall on a floating nuclear power plant(FNPP)deployed in the Bohai Sea.We utilized the Weibull and Gumbel extreme value distributions to fit the collected meteorological data and obtained a hazard curve for the event of an extreme snowfall where the FNPP is located,providing a basis for the frequency of extreme snowfall-initiating events.Our analysis indicates that extreme snowfall primarily affects the ventilation openings of the equipment,leading to the failure of devices such as the diesel generators.Additionally,extreme snowfall can result in a loss of off-site power(LOOP).Therefore,the developed extreme snowfall PSA model is mainly based on the LOOP event tree,considering responses such as snowfall removal by personnel.Our calculations indicate a core damage frequency(CDF)of 1.13×10^(-10) owing to extreme snowfall,which is relatively low.The results of the cut-set analysis indicate that valve failures in the core makeup tank(CMT),passive residual heat removal system(PRS),and in-containment refueling water storage tank(IRWST)significantly contribute to the CDF.展开更多
Blockage in the storage and transportation of waste resin is a difficult problem in the radioactive waste treatment process of nuclear power plants.In this study,in order to solve the problems of unstable resin transp...Blockage in the storage and transportation of waste resin is a difficult problem in the radioactive waste treatment process of nuclear power plants.In this study,in order to solve the problems of unstable resin transport concentration and easy blockage of conveying equipment and pipelines in nuclear power plants in China,a set of non⁃stirring conveying devices is developed,and theoretical calculations,simulation analysis and experimental verification are carried out.By transporting resin using the no stirring conveying device developed in this paper,it is not only to eliminate the risk of blockage and ensure the safety of transportation,but also to adjust the concentration of conveying resin to change the transport efficiency according to the operating conditions.The effective bearing rate of waste resin storage tank can be improved,so that the comprehensive performance of waste resin storage and transportation in nuclear power plants can be greatly improved.展开更多
Flow accelerated corrosion(FAC) is the main failure cause of the secondary circuit carbon steel piping in nuclear power plants.The piping failures caused by FAC have resulted in numerous unplanned outages and tragic...Flow accelerated corrosion(FAC) is the main failure cause of the secondary circuit carbon steel piping in nuclear power plants.The piping failures caused by FAC have resulted in numerous unplanned outages and tragic fatalities.The existing researches focus on the main factors contributing to FAC,which include metallurgical factors,environmental factors and hydrodynamic factors. Some effective FAC management methods and programs with long term monitoring and inspection data analysis are recommended.But a comprehensive FAC management system should be developed in order to mitigate and manage FAC systematically.In this paper,the FAC influencing factors are analyzed in combination with the operating conditions of the secondary circuit piping in the Third Qinshan Nuclear Power Plant(TQNPP),China(Third Qinshan Nuclear Power Company Limited,China).A comprehensive FAC mitigation and management system is developed for TQNPP secondary circuit piping.The system is composed of five processes,viz.materials substitution,water chemical optimization,long-term monitor strategy for the susceptible piping,integrity evaluation of the local thinning defects,and repair or replacement.With the implementation of the five processes,the material of FAC sensitive pipe fittings are modified from carbon steel to stainless steel,N_2H_4 and NH_3 are finally selected as the water chemical regulator of secondary circuit,the secondary circuit pips are classified according to FAC susceptibility in order to conduct long term monitoring strategy,and an integrity evaluation flow for local thinning caused by FAC in carbon steel piping is developed.If the component with local thinning defects is not fit-for-service,corresponding repair or replacement should be conducted.The comprehensive FAC mitigation and management system with five interrelated processes would be a cost-effective method of increasing personnel safety,plant safety and availability.展开更多
DCS (distributed control system) plays a decisive role in the overall operation of a nuclear power plant. If DCS fails, it will seriously affect the normal production of nuclear power plant, causing great losses. So...DCS (distributed control system) plays a decisive role in the overall operation of a nuclear power plant. If DCS fails, it will seriously affect the normal production of nuclear power plant, causing great losses. So it is very important to take perfect lightning protection measures on DCS of the nuclear power plant. In this paper, according to the actual situation of DCS in a nuclear power plant, by controlling lightning point, securely booting lightning into the ground network, improving low-resistance ground network, eliminating ground loops, determining the safety space, surge protection of power and signal, a set of complete lightning protection design scheme was systematically put forward. Some specific lightning protection measures were highlighted, such as the DCS grounding, equipotential bonds and shields, and some specific considerations were put forward. All of these could offer reference in the practical application.展开更多
Aiming to meet the demand of the country' s nuclear demonstration project on the CAP1400 nuclear power plant, Baosteel uses the roll-bonding technology and develops the SA-533 Type B CL. 1 + SA-240 Type 304L high-st...Aiming to meet the demand of the country' s nuclear demonstration project on the CAP1400 nuclear power plant, Baosteel uses the roll-bonding technology and develops the SA-533 Type B CL. 1 + SA-240 Type 304L high-strength and high-toughness clad steel plate with a shear strength of over 310 MPa for the nuclear power plant' s safety injection tank. The properties of the quenched and tempered and the simulated post-weld heat treatment states are systematically studied herein through a comprehensive inspection and evaluation of the composition,microstructure,and properties of the clad steel plate. The results show that the bonding interface has high shear strength and that the base metal has high strength and good toughness at low temperatures. Hence, the performance fully meets the technical requirements of the CAP1400 nuclear power plant' s safety injection tank in the country' s nuclear demonstration project. The roll-bonded clad steel plate can be used to manufacture the safety injection tank of the CAP1400 nuclear power plant.展开更多
Good practices of maintenance optimization in nuclear power field need to be effectively consolidated and inherited,and maintenance optimization can provide technology support to create a long-term reliable and econom...Good practices of maintenance optimization in nuclear power field need to be effectively consolidated and inherited,and maintenance optimization can provide technology support to create a long-term reliable and economic operation for nuclear power plants( NPPs) especially for a large number of nuclear powers under construction. Based on the development and application of maintenance template in developed countries,and combining with reliability-centered maintenance( RCM) analysis results and maintenance experience data over the past ten years in domestic NPPs, the development process of maintenance template was presented for Chinese pressurized water reactor( PWR) NPP,and the application of maintenance template to maintenance program development and maintenance optimization combined with cases were demonstrated. A shortcut was provided for improving the efficiency of maintenance optimization in domestic PWR NPP,and help to realize a safe,reliable,and economic operation for domestic NPPs.展开更多
With the global warming and sea level rising, it is widely recognized that there is an increasing tendency of typhoon occurrence frequency and intensity. The defenses code against typhoon attacks for nuclear power pla...With the global warming and sea level rising, it is widely recognized that there is an increasing tendency of typhoon occurrence frequency and intensity. The defenses code against typhoon attacks for nuclear power plant should be calibrated because of the increasing threat of typhoon disaster and severe consequences. This paper discusses the probabilistic approach of definitions about "probable maximum typhoon" and "probable maximum storm surge" in nuclear safety regulations of China and has made some design code calibrations by use of a newly proposed Double Layer Nested Mtdti-objective Probability Model (DLNMPM).展开更多
Recently, plant construction throughout the world, including nuclear power plant construction, has grown significantly. The scale of Korea’s nuclear power plant construction in particular, has increased gradually sin...Recently, plant construction throughout the world, including nuclear power plant construction, has grown significantly. The scale of Korea’s nuclear power plant construction in particular, has increased gradually since it won a contract for a nuclear power plant construction project in the United Arab Emirates in 2009. However, time and monetary resources have been lost in some nuclear power plant construction sites due to lack of risk management ability. The need to prevent losses at nuclear power plant construction sites has become more urgent because it demands professional skills and large-scale resources. Therefore, in this study, the Analytic Hierarchy Process (AHP) and Fuzzy Analytic Hierarchy Process (FAHP) were applied in order to make comparisons between decision-making methods, to assess the potential risks at nuclear power plant construction sites. To suggest the appropriate choice between two decision-making methods, a survey was carried out. From the results, the importance and the priority of 24 risk factors, classified by process, cost, safety, and quality, were analyzed. The FAHP was identified as a suitable method for risk assessment of nuclear power plant construction, compared with risk assessment using the AHP. These risk factors will be able to serve as baseline data for risk management in nuclear power plant construction projects.展开更多
The water level control system of steam generator in a pressurized water reactor of nuchear power plant plays an important role which effects the water level control of the steam generator are due the reverse dynamics...The water level control system of steam generator in a pressurized water reactor of nuchear power plant plays an important role which effects the water level control of the steam generator are due the reverse dynamics behavior,so the transient analysis of the steam generator should firstly solve their mathematical models.For determination of dynamic behavior and design and testing of the control system, a nonlinear math model is developed using one dimensional conservation equations of mass,momentum and energy of primary and secondary sides of the steam generator. The nonlinear model is verified with standard power plant data available in the references, then the steady states and transient calculations are performed for full power to 5% power reactor operation of the steam generator of Chinese Qinshan Nuclear Power Plant.展开更多
Abstract: The containment vessel of a nuclear power plant is the last barrier to prevent nuclear reactor radiation. Aseismic safety analysis is the key to appropriate containment vessel design. A prestressed concrete...Abstract: The containment vessel of a nuclear power plant is the last barrier to prevent nuclear reactor radiation. Aseismic safety analysis is the key to appropriate containment vessel design. A prestressed concrete containment vessel (PCCV) model with a semi-infinite elastic foundation and practical arrangement of tendons has been established to analyze the aseismic ability of the CPR1000 PCCV structure under seismic loads and internal pressure. A method to model the prestressing tendon and its interaction with concrete was proposed and the axial force of the prestressing tendons showed that the simulation was reasonable and accurate. The numerical results show that for the concrete structure, the location of the cylinder wall bottom around the equipment hatch and near the ring beam are critical locations with large principal stress. The concrete cracks occurred at the bottom of the PCCV cylinder wall under the peak earthquake motion of 0.50 g, however the PCCV was still basically in an elastic state. Furthermore, the concrete cracks occurred around the equipment hatch under the design internal pressure of 0.4MPa, but the steel liner was still in the elastic stage and its leak-proof function soundness was verified. The results provide the basis for analysis and design of containment vessels.展开更多
Oil cleaning agents generated from nuclear power plants(NPPs)are radioactive organic liquid wastes.To date,because there are no satisfactory industrial treatment measures,these wastes can only be stored for a long tim...Oil cleaning agents generated from nuclear power plants(NPPs)are radioactive organic liquid wastes.To date,because there are no satisfactory industrial treatment measures,these wastes can only be stored for a long time.In this work,the optimization for the supercritical water oxidation(SCWO)of the spent organic solvent was investigated.The main process parameters of DURSET(oil cleaning agent)SCWO,such as temperature,reaction time,and excess oxygen coefficient,were optimized using response surface methodology,and a quadratic polynomial model was obtained.The determination coefficient(R^(2))of the model is 0.9812,indicating that the model is reliable.The optimized process conditions were at 515 C,66 s,and an excess oxygen coefficient of 211%.Under these conditions,the chemical oxygen demand removal of organic matter could reach 99.5%.The temperature was found to be the main factor affecting the SCWO process.Ketones and benzene-based compounds may be the main intermediates in DURSET SCWO.This work provides basic data for the industrialization of the degradation of spent organic solvents from NPP using SCWO technology.展开更多
It is necessary to develop an automatic fault diagnosis system to avoid a possible nuclear disaster caused by an inaccurate fault diagnosis in the nuclear power plant by the operator. Because Radial Basis Function Neu...It is necessary to develop an automatic fault diagnosis system to avoid a possible nuclear disaster caused by an inaccurate fault diagnosis in the nuclear power plant by the operator. Because Radial Basis Function Neural Network (RBFNN) has the characteristics of optimal approximation and global approximation. The mixed coding of binary system and decimal system is introduced to the structure and parameters of RBFNN, which is trained in course of the genetic optimization. Finally, a fault diagnosis system according to the frequent faults in condensation and feed water system of nuclear power plant is set up. As a result, Genetic-RBF Neural Network (GRBFNN) makes the neural network smaller in size and higher in generalization ability. The diagnosis speed and accuracy are also improved.展开更多
The countermeasures are the actions that should be taken, after the occurrence of a nuclear accident to protect the public against the associated risks. These actions may be represented by sheltering, evacuation, dist...The countermeasures are the actions that should be taken, after the occurrence of a nuclear accident to protect the public against the associated risks. These actions may be represented by sheltering, evacuation, distribution of stable iodine tablets and/or relocation. This study represents a comprehensive probabilistic study to investigate the role of the adoption of the countermeasures in case of a hypothetical accident of type LOCA for nuclear power plant of PWR (1000 Mw). The effective doses in different organs, short and long health effects, and the associated risks are calculated with and without countermeasures. In addition, the overall costs of the accident and the costs of countermeasures are estimated which represent our first trials to know how much the proposed accident cost. The results showed that, the area around the site requires early and late countermeasures action after the accident especially in the downwind sectors. For late countermeasures, the duration time of relocation ranged from about two to 10 years. The adoption of the countermeasures increases the costs of emergency plan by 40% but reduces the risk associated the accident.展开更多
New research developments suggest that nuclear reactors using fusion may enter the market sooner than imagined even for mobile applications, like merchant ship propulsion and remote power generation. This article aims...New research developments suggest that nuclear reactors using fusion may enter the market sooner than imagined even for mobile applications, like merchant ship propulsion and remote power generation. This article aims at pointing such developments and how they could affect nuclear fusion. The method is enumerating the main nuclear reactors concepts, identifying new technological or theoretical developments useful to nuclear field, and analysing how new recombination could affect feasibility of nuclear fusion. New technologies or experimental results do not always work the way people imagine, being better or worse for intended effects or even bringing completely unforeseen effects. Results point the following designs could be successful, in descending order of potential: aneutronic nuclear reactions using lattice confinement, aneutronic nuclear reactions using inertial along magnetic confinement, hybrid fission-lattice confinement fusion, and fission reactions.展开更多
This paper presents the ageing mechanism of fuse in nuclear power plant in detail. Metal Electromigration is identified as the dominant ageing mechanism. On this basis, the dominant status indicators, temperature and ...This paper presents the ageing mechanism of fuse in nuclear power plant in detail. Metal Electromigration is identified as the dominant ageing mechanism. On this basis, the dominant status indicators, temperature and resistance of fuse were ensured, and current-temperature curve was proposed. The infrared thermal imaging technology was used to inspect the ageing condition and prove the current-temperature curve. Finally, the accelerated ageing testing was conducted abiding by the dominant ageing mechanism, and the lifetime was evaluated.展开更多
To evaluate the effects of the Hongyanhe Nuclear Power Plant on the zooplankton community in the surrounding seawater during summer, multiple environmental factors and zooplankton distribution along the east coast of ...To evaluate the effects of the Hongyanhe Nuclear Power Plant on the zooplankton community in the surrounding seawater during summer, multiple environmental factors and zooplankton distribution along the east coast of Liaodong Bay were investigated in the summer of 2017. In particular, the influences of seawater temperature, salinity, and chlorophyll a(Chl a) on the zooplankton community were analyzed. Zooplankton abundances and Chl a concentrations along the east coast of Liaodong Bay showed an initial increase followed by a decrease from July to September. During the three months, the zooplankton abundance was the highest(8116.70 ind m^(-3)) in August. The Shannon-Wiener index showed a downtrend from July to September, with the average value falling from 1.65 in July to 1.50 in September. Calanus sinicus, Paracalanus parvus, copepodid, and bivalve larvae were the dominant species/groups in the three months. The effects of the nuclear power plant's outlet on the environment factors were mainly reflected in the increased seawater temperature. Redundancy analysis showed that the zooplankton community was jointly affected by seawater temperature, salinity and Chl a concentration, and the degree of this impact varied monthly. The impact of seawater temperature on the zooplankton community was stronger than that of salinity. The primary impact of the Hongyanhe Nuclear Power Plant on the structure and distribution of the zooplankton community in the surrounding seawater during the summer was increased seawater temperature, which caused a reduction in the abundance of dominant species/groups.展开更多
: Consideration of the dynamic effects of the site and structural parameter uncertainty is required by the standards for nuclear power plants (NPPs) in most countries. The anti-seismic standards provide two basic m...: Consideration of the dynamic effects of the site and structural parameter uncertainty is required by the standards for nuclear power plants (NPPs) in most countries. The anti-seismic standards provide two basic methods to analyze parameter uncertainty. Directly manually dealing with the calculated floor response spectra (FRS) values of deterministic approaches is the first method. The second method is to perform probability statistical analysis of the FRS results on the basis of the Monte Carlo method. The two methods can only reflect the overall effects of the uncertain parameters, and the results cannot be screened for a certain parameter's influence and contribution. In this study, based on the dynamic analyses of the floor response spectra of NPPs, a comprehensive index of the assessed impact for various uncertain parameters is presented and recommended, including the correlation coefficient, the regression slope coefficient and Tornado swing. To compensate for the lack of guidance in the NPP seismic standards, the proposed method can effectively be used to evaluate the contributions of various parameters from the aspects &sensitivity, acuity and statistical swing correlations. Finally, examples are provided to verify the set of indicators from systematic and intuitive perspectives, such as the uncertainty of the impact of the structure parameters and the contribution to the FRS of NPPs. The index is sensitive to different types of parameters, which provides a new technique for evaluating the anti-seismic parameters required for NPPs.展开更多
The purpose of this study is to establish an intelligent expert system for nuclear power plant emergency response.A new framework of environmental risk management methodology by the concept of pattern recognition was ...The purpose of this study is to establish an intelligent expert system for nuclear power plant emergency response.A new framework of environmental risk management methodology by the concept of pattern recognition was introduced in this paper.A knowledge-based decision support system for emergency response and risk management of nuclear power plant was also discussed.The mathematical pattern relationship of accidental release effects on neighboring area and the corresponding response measures were presented in this paper.With this decision system,the decision maker can specify the procedure and minimize their human error in the decision process.The improvement of risk response and the quality of management system could be upgraded by this system.Besides,the methodology can also be served as a basis for the future development of environmental risk response system design.展开更多
Pico-and nano-eukaryotic plankton are important members of marine ecosystems.To understand their community structure and spatio-temporal variations in the Beibu Gulf,and to study the impact of Changjiang Nuclear Power...Pico-and nano-eukaryotic plankton are important members of marine ecosystems.To understand their community structure and spatio-temporal variations in the Beibu Gulf,and to study the impact of Changjiang Nuclear Power Plant(CNPP)located in the northwest coast of the Hainan Island on the eukaryotic plankton,we studied these issues in the coastal water near CNPP bimonthly from February 2018 to January 2019 via 18 S Illumina sequencing.The results reveal a higher genetic alphadiversity and less beta-diversity of the plankton community in small-size(0.45-5μm and 5-20μm)fractions than in large-size(20-200μm and>20μm)fractions.The small-sized phytoplankton,including Micromonas(Chlorophyta)and Minutocellus(Bacillariophyta),as well as heterotrophic plankton,including Paraphysomonas(Chrysophyceae),Ellobiopsis(Dinoflagellates),and Syndiniales(Dinoflagellates),took up a considerable proportion in eukaryotic plankton community.In addition,it showed a slight temperature increase and no significant difference in eukaryotic plankton community between the outfall of CNPP and other sampling sites,suggesting that the impact of the thermal discharge from the CNPP on local eukaryotic plankton community was limited.展开更多
文摘Hydrogen challenge mitigation stands as one of the main objectives in the management of severe accidents at Nuclear Power Plants (NPPs). Key strategies for hydrogen control include atmospheric inertization and hydrogen removal with Passive Autocatalytic Recombiners (PARs) being a commonly accepted approach. However, an examination of PAR operation specificity reveals potential inefficiencies and reliability issues in certain severe accident scenarios. Moreover, during the in-vessel stage of severe accident development, in some severe accident scenarios PARs can unexpectedly become a source of hydrogen detonation. The effectiveness of hydrogen removal systems depends on various factors, including the chosen strategies, severe accident scenarios, reactor building design, and other influencing factors. Consequently, a comprehensive hydrogen mitigation strategy must effectively incorporate a combination of strategies rather than be based on one strategy, taking into consideration the probabilistic risks and uncertainties associated with the implementation of PARs or other traditional methods. In response to these considerations, within the framework of this research it has been suggested a conceptual strategy to mitigate the hydrogen challenge during the in-vessel stage of severe accident development.
文摘This study presents a probabilistic safety analysis(PSA)method for the external event of extreme snowfall on a floating nuclear power plant(FNPP)deployed in the Bohai Sea.We utilized the Weibull and Gumbel extreme value distributions to fit the collected meteorological data and obtained a hazard curve for the event of an extreme snowfall where the FNPP is located,providing a basis for the frequency of extreme snowfall-initiating events.Our analysis indicates that extreme snowfall primarily affects the ventilation openings of the equipment,leading to the failure of devices such as the diesel generators.Additionally,extreme snowfall can result in a loss of off-site power(LOOP).Therefore,the developed extreme snowfall PSA model is mainly based on the LOOP event tree,considering responses such as snowfall removal by personnel.Our calculations indicate a core damage frequency(CDF)of 1.13×10^(-10) owing to extreme snowfall,which is relatively low.The results of the cut-set analysis indicate that valve failures in the core makeup tank(CMT),passive residual heat removal system(PRS),and in-containment refueling water storage tank(IRWST)significantly contribute to the CDF.
基金Sponsored by the Independent Scientific Research Fund of China Nuclear Power Engineering Co.,Ltd(Grant No.KY1744).
文摘Blockage in the storage and transportation of waste resin is a difficult problem in the radioactive waste treatment process of nuclear power plants.In this study,in order to solve the problems of unstable resin transport concentration and easy blockage of conveying equipment and pipelines in nuclear power plants in China,a set of non⁃stirring conveying devices is developed,and theoretical calculations,simulation analysis and experimental verification are carried out.By transporting resin using the no stirring conveying device developed in this paper,it is not only to eliminate the risk of blockage and ensure the safety of transportation,but also to adjust the concentration of conveying resin to change the transport efficiency according to the operating conditions.The effective bearing rate of waste resin storage tank can be improved,so that the comprehensive performance of waste resin storage and transportation in nuclear power plants can be greatly improved.
文摘Flow accelerated corrosion(FAC) is the main failure cause of the secondary circuit carbon steel piping in nuclear power plants.The piping failures caused by FAC have resulted in numerous unplanned outages and tragic fatalities.The existing researches focus on the main factors contributing to FAC,which include metallurgical factors,environmental factors and hydrodynamic factors. Some effective FAC management methods and programs with long term monitoring and inspection data analysis are recommended.But a comprehensive FAC management system should be developed in order to mitigate and manage FAC systematically.In this paper,the FAC influencing factors are analyzed in combination with the operating conditions of the secondary circuit piping in the Third Qinshan Nuclear Power Plant(TQNPP),China(Third Qinshan Nuclear Power Company Limited,China).A comprehensive FAC mitigation and management system is developed for TQNPP secondary circuit piping.The system is composed of five processes,viz.materials substitution,water chemical optimization,long-term monitor strategy for the susceptible piping,integrity evaluation of the local thinning defects,and repair or replacement.With the implementation of the five processes,the material of FAC sensitive pipe fittings are modified from carbon steel to stainless steel,N_2H_4 and NH_3 are finally selected as the water chemical regulator of secondary circuit,the secondary circuit pips are classified according to FAC susceptibility in order to conduct long term monitoring strategy,and an integrity evaluation flow for local thinning caused by FAC in carbon steel piping is developed.If the component with local thinning defects is not fit-for-service,corresponding repair or replacement should be conducted.The comprehensive FAC mitigation and management system with five interrelated processes would be a cost-effective method of increasing personnel safety,plant safety and availability.
基金Research Fund for Youth in Jiangsu Provincial Meteorological Bureau,China(Q201007)
文摘DCS (distributed control system) plays a decisive role in the overall operation of a nuclear power plant. If DCS fails, it will seriously affect the normal production of nuclear power plant, causing great losses. So it is very important to take perfect lightning protection measures on DCS of the nuclear power plant. In this paper, according to the actual situation of DCS in a nuclear power plant, by controlling lightning point, securely booting lightning into the ground network, improving low-resistance ground network, eliminating ground loops, determining the safety space, surge protection of power and signal, a set of complete lightning protection design scheme was systematically put forward. Some specific lightning protection measures were highlighted, such as the DCS grounding, equipotential bonds and shields, and some specific considerations were put forward. All of these could offer reference in the practical application.
文摘Aiming to meet the demand of the country' s nuclear demonstration project on the CAP1400 nuclear power plant, Baosteel uses the roll-bonding technology and develops the SA-533 Type B CL. 1 + SA-240 Type 304L high-strength and high-toughness clad steel plate with a shear strength of over 310 MPa for the nuclear power plant' s safety injection tank. The properties of the quenched and tempered and the simulated post-weld heat treatment states are systematically studied herein through a comprehensive inspection and evaluation of the composition,microstructure,and properties of the clad steel plate. The results show that the bonding interface has high shear strength and that the base metal has high strength and good toughness at low temperatures. Hence, the performance fully meets the technical requirements of the CAP1400 nuclear power plant' s safety injection tank in the country' s nuclear demonstration project. The roll-bonded clad steel plate can be used to manufacture the safety injection tank of the CAP1400 nuclear power plant.
文摘Good practices of maintenance optimization in nuclear power field need to be effectively consolidated and inherited,and maintenance optimization can provide technology support to create a long-term reliable and economic operation for nuclear power plants( NPPs) especially for a large number of nuclear powers under construction. Based on the development and application of maintenance template in developed countries,and combining with reliability-centered maintenance( RCM) analysis results and maintenance experience data over the past ten years in domestic NPPs, the development process of maintenance template was presented for Chinese pressurized water reactor( PWR) NPP,and the application of maintenance template to maintenance program development and maintenance optimization combined with cases were demonstrated. A shortcut was provided for improving the efficiency of maintenance optimization in domestic PWR NPP,and help to realize a safe,reliable,and economic operation for domestic NPPs.
基金supported by the Nationam Natural Science Foundation of China(Grant No.50679076)Office of State Flood Control and Drought Relief Headquarters of China(Grant No.20060120)
文摘With the global warming and sea level rising, it is widely recognized that there is an increasing tendency of typhoon occurrence frequency and intensity. The defenses code against typhoon attacks for nuclear power plant should be calibrated because of the increasing threat of typhoon disaster and severe consequences. This paper discusses the probabilistic approach of definitions about "probable maximum typhoon" and "probable maximum storm surge" in nuclear safety regulations of China and has made some design code calibrations by use of a newly proposed Double Layer Nested Mtdti-objective Probability Model (DLNMPM).
文摘Recently, plant construction throughout the world, including nuclear power plant construction, has grown significantly. The scale of Korea’s nuclear power plant construction in particular, has increased gradually since it won a contract for a nuclear power plant construction project in the United Arab Emirates in 2009. However, time and monetary resources have been lost in some nuclear power plant construction sites due to lack of risk management ability. The need to prevent losses at nuclear power plant construction sites has become more urgent because it demands professional skills and large-scale resources. Therefore, in this study, the Analytic Hierarchy Process (AHP) and Fuzzy Analytic Hierarchy Process (FAHP) were applied in order to make comparisons between decision-making methods, to assess the potential risks at nuclear power plant construction sites. To suggest the appropriate choice between two decision-making methods, a survey was carried out. From the results, the importance and the priority of 24 risk factors, classified by process, cost, safety, and quality, were analyzed. The FAHP was identified as a suitable method for risk assessment of nuclear power plant construction, compared with risk assessment using the AHP. These risk factors will be able to serve as baseline data for risk management in nuclear power plant construction projects.
文摘The water level control system of steam generator in a pressurized water reactor of nuchear power plant plays an important role which effects the water level control of the steam generator are due the reverse dynamics behavior,so the transient analysis of the steam generator should firstly solve their mathematical models.For determination of dynamic behavior and design and testing of the control system, a nonlinear math model is developed using one dimensional conservation equations of mass,momentum and energy of primary and secondary sides of the steam generator. The nonlinear model is verified with standard power plant data available in the references, then the steady states and transient calculations are performed for full power to 5% power reactor operation of the steam generator of Chinese Qinshan Nuclear Power Plant.
基金National Natural Science Foundation of China under Grant Nos.51138001 and 51479027
文摘Abstract: The containment vessel of a nuclear power plant is the last barrier to prevent nuclear reactor radiation. Aseismic safety analysis is the key to appropriate containment vessel design. A prestressed concrete containment vessel (PCCV) model with a semi-infinite elastic foundation and practical arrangement of tendons has been established to analyze the aseismic ability of the CPR1000 PCCV structure under seismic loads and internal pressure. A method to model the prestressing tendon and its interaction with concrete was proposed and the axial force of the prestressing tendons showed that the simulation was reasonable and accurate. The numerical results show that for the concrete structure, the location of the cylinder wall bottom around the equipment hatch and near the ring beam are critical locations with large principal stress. The concrete cracks occurred at the bottom of the PCCV cylinder wall under the peak earthquake motion of 0.50 g, however the PCCV was still basically in an elastic state. Furthermore, the concrete cracks occurred around the equipment hatch under the design internal pressure of 0.4MPa, but the steel liner was still in the elastic stage and its leak-proof function soundness was verified. The results provide the basis for analysis and design of containment vessels.
基金supported by Shanghai Sail Program(No.19YF1458000).
文摘Oil cleaning agents generated from nuclear power plants(NPPs)are radioactive organic liquid wastes.To date,because there are no satisfactory industrial treatment measures,these wastes can only be stored for a long time.In this work,the optimization for the supercritical water oxidation(SCWO)of the spent organic solvent was investigated.The main process parameters of DURSET(oil cleaning agent)SCWO,such as temperature,reaction time,and excess oxygen coefficient,were optimized using response surface methodology,and a quadratic polynomial model was obtained.The determination coefficient(R^(2))of the model is 0.9812,indicating that the model is reliable.The optimized process conditions were at 515 C,66 s,and an excess oxygen coefficient of 211%.Under these conditions,the chemical oxygen demand removal of organic matter could reach 99.5%.The temperature was found to be the main factor affecting the SCWO process.Ketones and benzene-based compounds may be the main intermediates in DURSET SCWO.This work provides basic data for the industrialization of the degradation of spent organic solvents from NPP using SCWO technology.
文摘It is necessary to develop an automatic fault diagnosis system to avoid a possible nuclear disaster caused by an inaccurate fault diagnosis in the nuclear power plant by the operator. Because Radial Basis Function Neural Network (RBFNN) has the characteristics of optimal approximation and global approximation. The mixed coding of binary system and decimal system is introduced to the structure and parameters of RBFNN, which is trained in course of the genetic optimization. Finally, a fault diagnosis system according to the frequent faults in condensation and feed water system of nuclear power plant is set up. As a result, Genetic-RBF Neural Network (GRBFNN) makes the neural network smaller in size and higher in generalization ability. The diagnosis speed and accuracy are also improved.
文摘The countermeasures are the actions that should be taken, after the occurrence of a nuclear accident to protect the public against the associated risks. These actions may be represented by sheltering, evacuation, distribution of stable iodine tablets and/or relocation. This study represents a comprehensive probabilistic study to investigate the role of the adoption of the countermeasures in case of a hypothetical accident of type LOCA for nuclear power plant of PWR (1000 Mw). The effective doses in different organs, short and long health effects, and the associated risks are calculated with and without countermeasures. In addition, the overall costs of the accident and the costs of countermeasures are estimated which represent our first trials to know how much the proposed accident cost. The results showed that, the area around the site requires early and late countermeasures action after the accident especially in the downwind sectors. For late countermeasures, the duration time of relocation ranged from about two to 10 years. The adoption of the countermeasures increases the costs of emergency plan by 40% but reduces the risk associated the accident.
文摘New research developments suggest that nuclear reactors using fusion may enter the market sooner than imagined even for mobile applications, like merchant ship propulsion and remote power generation. This article aims at pointing such developments and how they could affect nuclear fusion. The method is enumerating the main nuclear reactors concepts, identifying new technological or theoretical developments useful to nuclear field, and analysing how new recombination could affect feasibility of nuclear fusion. New technologies or experimental results do not always work the way people imagine, being better or worse for intended effects or even bringing completely unforeseen effects. Results point the following designs could be successful, in descending order of potential: aneutronic nuclear reactions using lattice confinement, aneutronic nuclear reactions using inertial along magnetic confinement, hybrid fission-lattice confinement fusion, and fission reactions.
文摘This paper presents the ageing mechanism of fuse in nuclear power plant in detail. Metal Electromigration is identified as the dominant ageing mechanism. On this basis, the dominant status indicators, temperature and resistance of fuse were ensured, and current-temperature curve was proposed. The infrared thermal imaging technology was used to inspect the ageing condition and prove the current-temperature curve. Finally, the accelerated ageing testing was conducted abiding by the dominant ageing mechanism, and the lifetime was evaluated.
基金supported by the National Key R&D Program of China (Nos. 2017YFC1404401,2017YFC1404402)the Science & Technology Basic Resources Investigation Program of China (No. 2017FY100803)the National Natural Science Foundation of China (No. 41306155)。
文摘To evaluate the effects of the Hongyanhe Nuclear Power Plant on the zooplankton community in the surrounding seawater during summer, multiple environmental factors and zooplankton distribution along the east coast of Liaodong Bay were investigated in the summer of 2017. In particular, the influences of seawater temperature, salinity, and chlorophyll a(Chl a) on the zooplankton community were analyzed. Zooplankton abundances and Chl a concentrations along the east coast of Liaodong Bay showed an initial increase followed by a decrease from July to September. During the three months, the zooplankton abundance was the highest(8116.70 ind m^(-3)) in August. The Shannon-Wiener index showed a downtrend from July to September, with the average value falling from 1.65 in July to 1.50 in September. Calanus sinicus, Paracalanus parvus, copepodid, and bivalve larvae were the dominant species/groups in the three months. The effects of the nuclear power plant's outlet on the environment factors were mainly reflected in the increased seawater temperature. Redundancy analysis showed that the zooplankton community was jointly affected by seawater temperature, salinity and Chl a concentration, and the degree of this impact varied monthly. The impact of seawater temperature on the zooplankton community was stronger than that of salinity. The primary impact of the Hongyanhe Nuclear Power Plant on the structure and distribution of the zooplankton community in the surrounding seawater during the summer was increased seawater temperature, which caused a reduction in the abundance of dominant species/groups.
基金the State Key Program of the National Natural Science Fundation of China under Grant No.51138001the Science Fund for Creative Research Groups of the National Natural Science Foundation of China under Grant No.51421064+2 种基金the State Key Laboratory of Coastal and Offshore Engineering Young Scholars Innovation Fund(LY1609)the Fundamental Research Funds for the Central Universities under Grant No.DUT15TD17the Open Research Fund of Hunan Province Key Laboratory of Key Technologies for Water Power Resources Development under Grant No.PKLHD20130
文摘: Consideration of the dynamic effects of the site and structural parameter uncertainty is required by the standards for nuclear power plants (NPPs) in most countries. The anti-seismic standards provide two basic methods to analyze parameter uncertainty. Directly manually dealing with the calculated floor response spectra (FRS) values of deterministic approaches is the first method. The second method is to perform probability statistical analysis of the FRS results on the basis of the Monte Carlo method. The two methods can only reflect the overall effects of the uncertain parameters, and the results cannot be screened for a certain parameter's influence and contribution. In this study, based on the dynamic analyses of the floor response spectra of NPPs, a comprehensive index of the assessed impact for various uncertain parameters is presented and recommended, including the correlation coefficient, the regression slope coefficient and Tornado swing. To compensate for the lack of guidance in the NPP seismic standards, the proposed method can effectively be used to evaluate the contributions of various parameters from the aspects &sensitivity, acuity and statistical swing correlations. Finally, examples are provided to verify the set of indicators from systematic and intuitive perspectives, such as the uncertainty of the impact of the structure parameters and the contribution to the FRS of NPPs. The index is sensitive to different types of parameters, which provides a new technique for evaluating the anti-seismic parameters required for NPPs.
基金Supported by Jinwen University of Science and Technology
文摘The purpose of this study is to establish an intelligent expert system for nuclear power plant emergency response.A new framework of environmental risk management methodology by the concept of pattern recognition was introduced in this paper.A knowledge-based decision support system for emergency response and risk management of nuclear power plant was also discussed.The mathematical pattern relationship of accidental release effects on neighboring area and the corresponding response measures were presented in this paper.With this decision system,the decision maker can specify the procedure and minimize their human error in the decision process.The improvement of risk response and the quality of management system could be upgraded by this system.Besides,the methodology can also be served as a basis for the future development of environmental risk response system design.
基金the National Key Research and Development Program of China(No.2019YFE0124700)the Scientific Research Foundation of Third Institute of Oceanography,MNR(No.2020017)。
文摘Pico-and nano-eukaryotic plankton are important members of marine ecosystems.To understand their community structure and spatio-temporal variations in the Beibu Gulf,and to study the impact of Changjiang Nuclear Power Plant(CNPP)located in the northwest coast of the Hainan Island on the eukaryotic plankton,we studied these issues in the coastal water near CNPP bimonthly from February 2018 to January 2019 via 18 S Illumina sequencing.The results reveal a higher genetic alphadiversity and less beta-diversity of the plankton community in small-size(0.45-5μm and 5-20μm)fractions than in large-size(20-200μm and>20μm)fractions.The small-sized phytoplankton,including Micromonas(Chlorophyta)and Minutocellus(Bacillariophyta),as well as heterotrophic plankton,including Paraphysomonas(Chrysophyceae),Ellobiopsis(Dinoflagellates),and Syndiniales(Dinoflagellates),took up a considerable proportion in eukaryotic plankton community.In addition,it showed a slight temperature increase and no significant difference in eukaryotic plankton community between the outfall of CNPP and other sampling sites,suggesting that the impact of the thermal discharge from the CNPP on local eukaryotic plankton community was limited.