The current parallel ankle rehabilitation robot(ARR)suffers from the problem of difficult real-time alignment of the human-robot joint center of rotation,which may lead to secondary injuries to the patient.This study ...The current parallel ankle rehabilitation robot(ARR)suffers from the problem of difficult real-time alignment of the human-robot joint center of rotation,which may lead to secondary injuries to the patient.This study investigates type synthesis of a parallel self-alignment ankle rehabilitation robot(PSAARR)based on the kinematic characteristics of ankle joint rotation center drift from the perspective of introducing"suitable passive degrees of freedom(DOF)"with a suitable number and form.First,the self-alignment principle of parallel ARR was proposed by deriving conditions for transforming a human-robot closed chain(HRCC)formed by an ARR and human body into a kinematic suitable constrained system and introducing conditions of"decoupled"and"less limb".Second,the relationship between the self-alignment principle and actuation wrenches(twists)of PSAARR was analyzed with the velocity Jacobian matrix as a"bridge".Subsequently,the type synthesis conditions of PSAARR were proposed.Third,a PSAARR synthesis method was proposed based on the screw theory and type of PSAARR synthesis conducted.Finally,an HRCC kinematic model was established to verify the self-alignment capability of the PSAARR.In this study,93 types of PSAARR limb structures were synthesized and the self-alignment capability of a human-robot joint axis was verified through kinematic analysis,which provides a theoretical basis for the design of such an ARR.展开更多
Objective: To explore the effect of lower limb rehabilitation robot combined with task-oriented training on stroke patients and its influence on KFAROM score. Methods: 100 stroke patients with hemiplegia admitted to o...Objective: To explore the effect of lower limb rehabilitation robot combined with task-oriented training on stroke patients and its influence on KFAROM score. Methods: 100 stroke patients with hemiplegia admitted to our hospital from January 2023 to December 2023 were randomly divided into two groups, the control group (50 cases) was given task-oriented training assisted by nurses, and the observation group (50 cases) was given lower limb rehabilitation robot with task-oriented training. Lower limb balance, lower limb muscle strength, motor function, ankle function, knee flexion range of motion and walking ability were observed. Results: After treatment, the scores of BBS, quadriceps femoris and hamstrings in the observation group were significantly higher than those in the control group (P Conclusion: In the clinical treatment of stroke patients, the combination of task-oriented training and lower limb rehabilitation robot can effectively improve the lower limb muscle strength, facilitate the recovery of balance function, and have a significant effect on the recovery of motor function, which can improve the walking ability of stroke patients and the range of motion of knee flexion, and achieve more ideal therapeutic effectiveness.展开更多
In order to mitigate the effects of space adaptation syndrome(SAS) and improve the training efficiency of the astronauts, a novel astronaut rehabilitative training robot(ART) was proposed. ART can help the astronauts ...In order to mitigate the effects of space adaptation syndrome(SAS) and improve the training efficiency of the astronauts, a novel astronaut rehabilitative training robot(ART) was proposed. ART can help the astronauts to carry out the bench press training in the microgravity environment. Firstly, a dynamic model of cable driven unit(CDU) was established whose accuracy was verified through the model identification. Secondly, to improve the accuracy and the speed of the active loading, an active loading hybrid force controller was proposed on the basis of the dynamic model of the CDU. Finally, the actual effect of the hybrid force controller was tested by simulations and experiments. The results suggest that the hybrid force controller can significantly improve the precision and the dynamic performance of the active loading with the maximum phase lag of the active loading being 9° and the maximum amplitude error being 2% at the frequency range of 10 Hz. The controller can meet the design requirements.展开更多
Rehabilitation robots can help physiatrists to assist patients in improving their movement ability.Due to the interaction between rehabilitation robots and patients,the robots need to complete rehabilitation training ...Rehabilitation robots can help physiatrists to assist patients in improving their movement ability.Due to the interaction between rehabilitation robots and patients,the robots need to complete rehabilitation training on a safe basis.This paper presents an approach for smooth trajectory planning for a cable-driven parallel waist rehabilitation robot(CDPWRR)based on the rehabilitation evaluation factors.First,motion capture technology is used to collect the motion data of several volunteers in waist twisting.Considering the impact of motion variability,the feature points at the center of the human pelvis are obtained after eliminating unreasonable data through rationality judgments.Then,point-to-point waist training trajectory planning based on quintic polynomial and cycloid functions,and multipoint waist training trajectory planning based on quintic B-spline functions are carried out.The corresponding planned curves and kinematics characteristics using three methods are compared and analyzed.Subsequently,the rehabilitation evaluation factors are introduced to conduct smooth trajectory planning for waist training,and the waist trajectory with better compliance is obtained based on the safety and feasibility of waist motion.Finally,the physical prototype of the CDPWRR is built,and the feasibility and effectiveness of the proposed smooth trajectory planning method are proved by numerical analysis and experiments.展开更多
The National Natural Science Foundation of China is one of the major funding agencies for neuro rehabilitation research in China.This study reviews the frontier directions and achievements in the field of neurorehabil...The National Natural Science Foundation of China is one of the major funding agencies for neuro rehabilitation research in China.This study reviews the frontier directions and achievements in the field of neurorehabilitation in China and wo rldwide.We used data from the Web of Science Core Collection(WoSCC) database to analyze the publications and data provided by the National Natural Science Foundation of China to analyze funding information.In addition,the prospects for neurorehabilitation research in China are discussed.From 2010 to 2022,a total of 74,220 publications in neurorehabilitation were identified,with there being an overall upward tendency.During this period,the National Natural Science Foundation of China has funded 476 research projects with a total funding of 192.38 million RMB to support neuro rehabilitation research in China.With the support of the National Natural Science Foundation of China,China has made some achievements in neurorehabilitation research.Research related to neurorehabilitation is believed to be making steady and significant progress in China.展开更多
Converting customer needs into specific forms and providing consumers with services are crucial in product design.Currently,conversion is no longer difficult due to the development of modern technology,and various mea...Converting customer needs into specific forms and providing consumers with services are crucial in product design.Currently,conversion is no longer difficult due to the development of modern technology,and various measures can be applied for product realization,thus increasing the complexity of analysis and evaluation in the design process.The focus of the design process has thus shifted from problem solving to minimizing the total amount of information content.This paper presents a New Hybrid Axiomatic Design(AD)Methodology based on iteratively matching and merging design parameters that meet the independence axiom and attribute constraints by applying trimming technology,the ideal final results,and technology evolution theory.The proposed method minimizes the total amount of information content and improves the design quality.Finally,a case study of a rehabilitation robot design for hemiplegic patients is presented.The results indicate that the iterative matching and merging of related attributes can minimize the total amount of information content,reduce the cost,and improve design efficiency.Additionally,evolutionary technology prediction can ensure product novelty and improve market competitiveness.The methodology provides an excellent way to design a new(or improved)product.展开更多
Dyskinesia of the upper limbs caused by stroke,sports injury,or trafc accidents limits the ability to perform the activities of daily living.Besides the necessary medical treatment,correct and scientifc rehabilitation...Dyskinesia of the upper limbs caused by stroke,sports injury,or trafc accidents limits the ability to perform the activities of daily living.Besides the necessary medical treatment,correct and scientifc rehabilitation training for the injured joint is an important auxiliary means during the treatment of the efected upper limb.Conventional upperlimb rehabilitation robots have some disadvantages,such as a complex structure,poor compliance,high cost,and poor portability.In this study,a novel soft wearable upper limb rehabilitation robot(SWULRR)with reinforced soft pneumatic actuators(RSPAs)that can withstand high pressure and featuring excellent loading characteristics was developed.Driven by RSPAs,this portable SWULRR can perform rehabilitation training of the wrist and elbow joints.In this study,the kinematics of an SWULRR were analyzed,and the force and motion characteristics of RSPA were studied experimentally.The results provide a reference for the development and application of wearable upper limb rehabilitation robots.An experimental study on the rotation angle of the wrist and the pressure of the RSPA was conducted to test the efect of the rehabilitation training and verify the rationality of the theoretical model.The process of wrist rehabilitation training was tested and evaluated,indicating that SWULRR with RSPAs will enhance the fexibility,comfort,and safety of rehabilitation training.This work is expected to promote the development of wearable upper-limb rehabilitation robots based on modular reinforced soft pneumatic actuators.展开更多
A novel 5-DOF exoskeletal rehabilitation robot for upper limbs of hemiplegic patients caused by stroke is proposed in this paper. Its hardware structure is introduced and the control methods are ana- lyzed. To impleme...A novel 5-DOF exoskeletal rehabilitation robot for upper limbs of hemiplegic patients caused by stroke is proposed in this paper. Its hardware structure is introduced and the control methods are ana- lyzed. To implement intelligent and interactive rehabilitation exercises, motion intention of patients' up- per limb is introduced into control methods of rehabilitation exercises. In passive motions, according to the character of unilateral impaired, multi-channels surface electromyogram (sEMG) signals of patients' healthy arm muscles are acquired and analyzed to recognize the upper limb motions, then drive the robot and assist paralysis ann's rehabilitation exercises. In active-resistant motions, because patients are re- covered with some muscle forces and active motion ability after a rehabilitation period, the terminal force loaded on the robot by an impaired arm are estimated with multi-channel joint torque sensors, according to which, the terminal velocity of the robot is controlled to drive the joint motions with a damp controller.展开更多
Study results in the last decades show that amount and quality of physical exercises,then the active participation,and now the cognitive involvement of patient in rehabilitation training are crucial to enhance recover...Study results in the last decades show that amount and quality of physical exercises,then the active participation,and now the cognitive involvement of patient in rehabilitation training are crucial to enhance recovery outcome of motor dysfunction patients after stroke.Rehabilitation robots mainly have been developed along this direction to satisfy requirements of recovery therapy,or focused on one or more of the above three points.Therefore,rehabilitation robot based on neuro-machine interaction has been proposed for the paralyzed limb training of post-stroke patient,which utilizes motor related EEG,UCSDI(Ultrasound Current Source Density Imaging),EMG for the robot control and feeds back the multi-sensory interaction information such as visual,auditory,force,haptic sensation to the patient simultaneously.This neuro-controlled and perceptual rehabilitation robot will bring great benefits to post-stroke patients.In order to develop such a kind of rehabilitation robot,some key technologies,such as non-invasive precise measurement and decoding of neural signals,realistic sensation feedback,coordinated control for both the rehabilitation robot and the patient,need to be solved.In this paper,some fundamental problems in developing and optimizing such a kind of rehabilitation robot based on neuro-machine interaction are proposed and discussed.展开更多
<b><span style="font-family:Verdana;">Background</span></b><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="f...<b><span style="font-family:Verdana;">Background</span></b><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">: </span></b></span></span></span></span><span><span><span><span><span style="font-family:;" "=""><span style="font-family:Verdana;">Active rehabilitation of the paralyzed limb is necessary for functional recovery from upper limb paralysis after stroke. In particular, the </span><span style="font-family:Verdana;">amount of training is very important, and robot rehabilitation is useful. Howev</span><span style="font-family:Verdana;">er, most conventional robots are expensive, large, and stationary. We have d</span><span style="font-family:Verdana;">eveloped Rehabili-Mouse, a new tabletop rehabilitation robot that is compact and portable. The purpose of this study was to conduct paralyzed upper limb training for a patient after stroke using Rehabili-Mouse and to examine its effect.</span></span></span></span></span></span><span><span><span><span><span style="font-family:;" "=""> </span></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Case</span></b></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">: </span></b></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">The patient was a 44-year-old man who had left-sided paresis after a right cerebral infarction, 3 months after onset. The training was carried out between February 2021 and March 2021 at Oyu Rehabilitation Hot</span></span></span></span></span><span><span><span><span><span style="font-family:;" "=""><span style="font-family:Verdana;">spring Hospital. The training was 20 minutes of Rehabili-Mouse in addition to 40 minutes of usual occupational therapy and performed five times a week </span><span style="font-family:Verdana;">for four weeks. Upper limb functions were evaluated before and after the t</span><span style="font-family:Verdana;">raining, and two questionnaires of patient satisfaction with the device and the training were administered after the completion of the training. Upper limb function improved. The patient’s satisfaction with the device was poor, but his satisfaction with the training was good.</span></span></span></span></span></span><span><span><span><span><span style="font-family:;" "=""> </span></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Discussion</span></b></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">: </span></b></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">Training for the paralyzed upper limb after stroke using Rehabili-Mouse improved upper limb function and satisfied the trained patient. We plan to increase the number of cases and conduct further studies.</span></span></span></span></span>展开更多
To achieve human lower limbs rehabilitation training, the exoskeleton lower limbs rehabilitation robot is designed. Through respective motor driving, the retarding mechanism and telescopic adjusting mechanism, the fun...To achieve human lower limbs rehabilitation training, the exoskeleton lower limbs rehabilitation robot is designed. Through respective motor driving, the retarding mechanism and telescopic adjusting mechanism, the function of human walking is accomplished. After the design of the mechanical structure, the finite element analysis is carried out on the important parts and the control system is achieved by Single Chip Microcomputer.展开更多
In this paper, it introduced the mechanical structure design of the multifunctional walking rehabilitation robot, We used the SolidWorks to design and assemble the rehabilitation robot, and optimized the rehabilitatio...In this paper, it introduced the mechanical structure design of the multifunctional walking rehabilitation robot, We used the SolidWorks to design and assemble the rehabilitation robot, and optimized the rehabilitation robot based on ergonomics. The result shows that the multifunctional walking rehabilitation robot has the characteristics of complete functions, convenient operation, compact structure and so on. It can meet the requirements of medical care equipment, and effectively complete the nursing work of patients.展开更多
Objective:The effect of ankle rehabilitation robot on joint movement of hemiplegic patients was studied and quantitatively evaluated.Methods 90 hemiplegic patients with lower limb dysfunction treated in our hospital f...Objective:The effect of ankle rehabilitation robot on joint movement of hemiplegic patients was studied and quantitatively evaluated.Methods 90 hemiplegic patients with lower limb dysfunction treated in our hospital from April 2017 to March 2019 were selected as subjects.The patients were randomly divided into two groups:control group(n=45)and observation group(n=45).The patients in the two groups received language training,physiotherapy,exercise therapy,spa,occupational therapy,massage and other comprehensive rehabilitation treatment,on the basis of which the observation group received the auxiliary intervention of ankle rehabilitation robot.The soft tissue compliance of the patients was evaluated by ankle metatarsal flexion moment before and after treatment,the metatarsal flexor tension was evaluated by modified Tardieu scale,and the clinical effect was evaluated by ankle active ankle dorsiflexion.Results After treatment,the ankle flexion angles(0°,10°,20°,30°)in the two groups were significantly lower than those in the control group(P<0.05).Results compared with before treatment,the ankle flexion angles(0°,10°,20°,30°)in the two groups were significantly lower than those in the control group(P<0.05).After treatment,the angle of R1 and R2 measured by modified Tardieu scale of ankle plantar flexor group increased significantly,and the difference of R2-R1 decreased significantly(P<0.05).The improvement degree of the observation group was significantly better than that of the control group(P<0.05).After treatment,the active ankle extension activity of the two groups was significantly higher than that before treatment(P<0.05),and the effective rate of the observation group was significantly higher than that of the observation group(P<0.05).Conclusion Auxiliary intervention with ankle rehabilitation robot system can effectively improve the compliance of ankle soft tissue in spastic hemiplegia,reduce the contracture of metatarsal flexor muscle and improve the disturbance of joint movement in a short time.At the same time,the degree of coordination and acceptance of patients and their families is high,which is an effective means to improve the therapeutic effect.展开更多
<span style="font-family:Verdana;"><strong>Background:</strong></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span st...<span style="font-family:Verdana;"><strong>Background:</strong></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> This study aims to evaluate the effectiveness of the robotic device used in lower limb rehabilitation to reduce motor impairment and improve motor performance in patients with traumatic spinal injury.</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Methods:</span></b></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> The data were obtained by retrospective analysis of patients who underwent lower extremity rehabilitation after traumatic spinal injury by robot-assisted rehabilitation in the hospital between December 2017 and December 2019. The results were statistically analyzed and shown as mean ± SD (min-max).</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Results:</span></b></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> A total of 51 patients with mean age of 59.51 ± 8.2 (38</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">-</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">72) were admitted to the clinic. Mean ages of thirty-one male patients and twenty females patients were 58.74 ± 8.88 (38 - 77) and 60.7 ± 7.09 (44</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">-</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">72), respectively. Comparing ages in terms of gender, it was not statistically significant (p = 0.441). Body mass indexes of male patients were 32.84 ± 6.52 (20 - 48) and 31.4 ± 7.73 (18 - 48) for females. Body mass index of patients was not statistically significant in terms of their gender (p = 0.478). Oswestry disability index scores were 32.04 ± 10.74 (16 - 58) before treatment and 30.69 ± 10.31 (15 - 55) after treatment. Oswestry disability index values before and after robotic rehabilitation were statistically significant (p < 0.001). Significant improvement was observed in ASIA scale values after rehabilitation.</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Conclusions:</span></b></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> The motor function gains obtained during the robot-assisted treatment of traumatic spinal injury patients showed robotic device was useful in the training program. Robotic rehabilitation was effective in the improvement of the lower extremities during motor examination.</span></span></span>展开更多
The mechanical structure as well as the schematic organization has been designed to achieve lower limb rehabilitation training function; Solidworks has been used to model the robot. And the robot has been optimized by...The mechanical structure as well as the schematic organization has been designed to achieve lower limb rehabilitation training function; Solidworks has been used to model the robot. And the robot has been optimized by the means of human-interference engineering. The primary components of the robot have been analyzed by Ansys workbench.展开更多
Aiming at the problem that the existing ankle rehabilitation robot is difficult to fully fit the complex motion of human ankle joint and has poor human-machine motion compatibility,an equivalent series mechanism model...Aiming at the problem that the existing ankle rehabilitation robot is difficult to fully fit the complex motion of human ankle joint and has poor human-machine motion compatibility,an equivalent series mechanism model that is highly matched with the actual bone structure of the human ankle joint is proposed and mapped into a parallel rehabilita-tion mechanism.The parallel rehabilitation mechanism has two virtual motion centers(VMCs),which can simulate the complex motion of the ankle joint,adapt to the individual differences of various patients,and can meet the reha-bilitation needs of both left and right feet of patients.Firstly,based on the motion properties and physiological structure of the human ankle joint,the mapping relationship between the rehabilitation mechanism and ankle joint is determined,and the series equivalent model of the ankle joint is established.According to the kinematic and con-straint properties of the ankle equivalent model,the configuration design of the parallel ankle rehabilitation robot is carried out.Secondly,according to the intersecting motion planes theory,the full-cycle mobility of the mechanism is proved,and the continuous axis of the mechanism is judged based on the constraint power and its derivative.Then,the kinematics of the parallel ankle rehabilitation robot is analyzed.Finally,based on the OpenSim biomechanical soft-ware,a human-machine coupling rehabilitation simulation model is established to evaluate the rehabilitation effect,which lays the foundation for the formulation of a rehabilitation strategy for the later prototype.展开更多
With the increase in the number of stroke patients,there is a growing demand for rehabilitation training.Robot-assisted training is expected to play a crucial role in meeting this demand.To ensure the safety and comfo...With the increase in the number of stroke patients,there is a growing demand for rehabilitation training.Robot-assisted training is expected to play a crucial role in meeting this demand.To ensure the safety and comfort of patients during rehabilitation training,it is important to have a patient-cooperative compliant control system for rehabilitation robots.In order to enhance the motion compliance of patients during rehabilitation training,a hierarchical adaptive patient-cooperative compliant control strategy that includes patient-passive exercise and patient-cooperative exercise is proposed.A low-level adaptive backstepping position controller is selected to ensure accurate tracking of the desired trajectory.At the high-level,an adaptive admittance controller is employed to plan the desired trajectory based on the interaction force between the patient and the robot.The results of the patient-robot cooperation experiment on a rehabilitation robot show a significant improvement in tracking trajectory,with a decrease of 76.45%in the dimensionless squared jerk(DSJ)and a decrease of 15.38%in the normalized root mean square deviation(NRMSD)when using the adaptive admittance controller.The proposed adaptive patient-cooperative control strategy effectively enhances the compliance of robot movements,thereby ensuring the safety and comfort of patients during rehabilitation training.展开更多
This article introduces a cable-driven lower limb rehabilitation robot with movable distal anchor points(M-CDLR).The traditional cable-driven parallel robots(CDPRs)control the moving platform by changing the length of...This article introduces a cable-driven lower limb rehabilitation robot with movable distal anchor points(M-CDLR).The traditional cable-driven parallel robots(CDPRs)control the moving platform by changing the length of cables,M-CDLR can also adjust the position of the distal anchor point when the moving platform moves.The M-CDLR this article proposed has gait and single-leg training modes,which correspond to the plane and space motion of the moving platform,respectively.After introducing the system structure configuration,the generalized kinematics and dynamics of M-CDLR are established.The fully constrained CDPRs can provide more stable rehabilitation training than the under-constrained one but requires more cables.Therefore,a motion planning method for the movable distal anchor point of M-CDLR is proposed to realize the theoretically fully constrained with fewer cables.Then the expected trajectory of the moving platform is obtained from the motion capture experiment,and the motion planning of M-CDLR under two training modes is simulated.The simulation results verify the effectiveness of the proposed motion planning method.This study serves as a basic theoretical study of the structure optimization and control strategy of M-CDLR.展开更多
This study addresses two issues about the interaction of the upper limb rehabilitation robot with individuals who have disabilities.The first step is to estimate the human's target position(also known as TPH).The ...This study addresses two issues about the interaction of the upper limb rehabilitation robot with individuals who have disabilities.The first step is to estimate the human's target position(also known as TPH).The second step is to develop a robust adaptive impedance control mechanism.A novel Non-singular Terminal Sliding Mode Control combined with an adaptive super-twisting controller is being developed to achieve this goal.This combination's purpose is to provide high reliability,continuous performance tracking of the system's trajectories.The proposed adaptive control strategy reduces matched dynamic uncertainty while also lowering chattering,which is the sliding mode's most glaring issue.The proposed TPH is coupled with adaptive impedance control with the use of a Radial Basis Function Neural Network,which allows a robotic exoskeleton to simply track the desired impedance model.To validate the approach in real-time,an exoskeleton robot was deployed in controlled experimental circumstances.A comparison study has been set up to show how the adaptive impedance approach proposed is better than other traditional controllers.展开更多
The authors investigate the trajectory tracking control problem of an upper limb reha-bilitation robot system with unknown dynamics.To address the system's uncertainties and improve the tracking accuracy of the re...The authors investigate the trajectory tracking control problem of an upper limb reha-bilitation robot system with unknown dynamics.To address the system's uncertainties and improve the tracking accuracy of the rehabilitation robot,an adaptive neural full-state feedback control is proposed.The neural network is utilised to approximate the dy-namics that are not fully modelled and adapt to the interaction between the upper limb rehabilitation robot and the patient.By incorporating a high-gain observer,unmeasurable state information is integrated into the output feedback control.Taking into consider-ation the issue of joint position constraints during the actual rehabilitation training process,an adaptive neural full-state and output feedback control scheme with output constraint is further designed.From the perspective of safety in human–robot interaction during rehabilitation training,log-type barrier Lyapunov function is introduced in the output constraint controller to ensure that the output remains within the predefined constraint region.The stability of the closed-loop system is proved by Lyapunov stability theory.The effectiveness of the proposed control scheme is validated by applying it to an upper limb rehabilitation robot through simulations.展开更多
基金Supported by Key Scientific Research Platforms and Projects of Guangdong Regular Institutions of Higher Education of China(Grant No.2022KCXTD033)Guangdong Provincial Natural Science Foundation of China(Grant No.2023A1515012103)+1 种基金Guangdong Provincial Scientific Research Capacity Improvement Project of Key Developing Disciplines of China(Grant No.2021ZDJS084)National Natural Science Foundation of China(Grant No.52105009).
文摘The current parallel ankle rehabilitation robot(ARR)suffers from the problem of difficult real-time alignment of the human-robot joint center of rotation,which may lead to secondary injuries to the patient.This study investigates type synthesis of a parallel self-alignment ankle rehabilitation robot(PSAARR)based on the kinematic characteristics of ankle joint rotation center drift from the perspective of introducing"suitable passive degrees of freedom(DOF)"with a suitable number and form.First,the self-alignment principle of parallel ARR was proposed by deriving conditions for transforming a human-robot closed chain(HRCC)formed by an ARR and human body into a kinematic suitable constrained system and introducing conditions of"decoupled"and"less limb".Second,the relationship between the self-alignment principle and actuation wrenches(twists)of PSAARR was analyzed with the velocity Jacobian matrix as a"bridge".Subsequently,the type synthesis conditions of PSAARR were proposed.Third,a PSAARR synthesis method was proposed based on the screw theory and type of PSAARR synthesis conducted.Finally,an HRCC kinematic model was established to verify the self-alignment capability of the PSAARR.In this study,93 types of PSAARR limb structures were synthesized and the self-alignment capability of a human-robot joint axis was verified through kinematic analysis,which provides a theoretical basis for the design of such an ARR.
文摘Objective: To explore the effect of lower limb rehabilitation robot combined with task-oriented training on stroke patients and its influence on KFAROM score. Methods: 100 stroke patients with hemiplegia admitted to our hospital from January 2023 to December 2023 were randomly divided into two groups, the control group (50 cases) was given task-oriented training assisted by nurses, and the observation group (50 cases) was given lower limb rehabilitation robot with task-oriented training. Lower limb balance, lower limb muscle strength, motor function, ankle function, knee flexion range of motion and walking ability were observed. Results: After treatment, the scores of BBS, quadriceps femoris and hamstrings in the observation group were significantly higher than those in the control group (P Conclusion: In the clinical treatment of stroke patients, the combination of task-oriented training and lower limb rehabilitation robot can effectively improve the lower limb muscle strength, facilitate the recovery of balance function, and have a significant effect on the recovery of motor function, which can improve the walking ability of stroke patients and the range of motion of knee flexion, and achieve more ideal therapeutic effectiveness.
基金Project(61175128) supported by the National Natural Science Foundation of ChinaProject(2008AA040203) supported by the National High Technology Research and Development Program of ChinaProject(QC2010009) supported by the Natural Science Foundation of Heilongjiang Province,China
文摘In order to mitigate the effects of space adaptation syndrome(SAS) and improve the training efficiency of the astronauts, a novel astronaut rehabilitative training robot(ART) was proposed. ART can help the astronauts to carry out the bench press training in the microgravity environment. Firstly, a dynamic model of cable driven unit(CDU) was established whose accuracy was verified through the model identification. Secondly, to improve the accuracy and the speed of the active loading, an active loading hybrid force controller was proposed on the basis of the dynamic model of the CDU. Finally, the actual effect of the hybrid force controller was tested by simulations and experiments. The results suggest that the hybrid force controller can significantly improve the precision and the dynamic performance of the active loading with the maximum phase lag of the active loading being 9° and the maximum amplitude error being 2% at the frequency range of 10 Hz. The controller can meet the design requirements.
基金Supported by National Natural Science Foundation of China(Grant Nos.52205014,51925502)the Fundamental Research Funds for the Central Universities(Grant Nos.JZ2022HGTA0325,JZ2022HGQA0147).
文摘Rehabilitation robots can help physiatrists to assist patients in improving their movement ability.Due to the interaction between rehabilitation robots and patients,the robots need to complete rehabilitation training on a safe basis.This paper presents an approach for smooth trajectory planning for a cable-driven parallel waist rehabilitation robot(CDPWRR)based on the rehabilitation evaluation factors.First,motion capture technology is used to collect the motion data of several volunteers in waist twisting.Considering the impact of motion variability,the feature points at the center of the human pelvis are obtained after eliminating unreasonable data through rationality judgments.Then,point-to-point waist training trajectory planning based on quintic polynomial and cycloid functions,and multipoint waist training trajectory planning based on quintic B-spline functions are carried out.The corresponding planned curves and kinematics characteristics using three methods are compared and analyzed.Subsequently,the rehabilitation evaluation factors are introduced to conduct smooth trajectory planning for waist training,and the waist trajectory with better compliance is obtained based on the safety and feasibility of waist motion.Finally,the physical prototype of the CDPWRR is built,and the feasibility and effectiveness of the proposed smooth trajectory planning method are proved by numerical analysis and experiments.
文摘The National Natural Science Foundation of China is one of the major funding agencies for neuro rehabilitation research in China.This study reviews the frontier directions and achievements in the field of neurorehabilitation in China and wo rldwide.We used data from the Web of Science Core Collection(WoSCC) database to analyze the publications and data provided by the National Natural Science Foundation of China to analyze funding information.In addition,the prospects for neurorehabilitation research in China are discussed.From 2010 to 2022,a total of 74,220 publications in neurorehabilitation were identified,with there being an overall upward tendency.During this period,the National Natural Science Foundation of China has funded 476 research projects with a total funding of 192.38 million RMB to support neuro rehabilitation research in China.With the support of the National Natural Science Foundation of China,China has made some achievements in neurorehabilitation research.Research related to neurorehabilitation is believed to be making steady and significant progress in China.
基金Supported by Research Startup Fund Project of Fujian University of Technology(Grant No.GY-Z20089)Science Foundation for Young Scholars of Fujian Province of China(Grant No.2018J05099)Education and Scientific Research Projects of Young Teachers in Fujian Province of China(Grant No.JAT160313).
文摘Converting customer needs into specific forms and providing consumers with services are crucial in product design.Currently,conversion is no longer difficult due to the development of modern technology,and various measures can be applied for product realization,thus increasing the complexity of analysis and evaluation in the design process.The focus of the design process has thus shifted from problem solving to minimizing the total amount of information content.This paper presents a New Hybrid Axiomatic Design(AD)Methodology based on iteratively matching and merging design parameters that meet the independence axiom and attribute constraints by applying trimming technology,the ideal final results,and technology evolution theory.The proposed method minimizes the total amount of information content and improves the design quality.Finally,a case study of a rehabilitation robot design for hemiplegic patients is presented.The results indicate that the iterative matching and merging of related attributes can minimize the total amount of information content,reduce the cost,and improve design efficiency.Additionally,evolutionary technology prediction can ensure product novelty and improve market competitiveness.The methodology provides an excellent way to design a new(or improved)product.
基金Supported by National Natural Science Foundation of China(Grant Nos.51975505 and U2037202)Science and Technology Project of Hebei Education Department(Grant No.SLRC2019039)+1 种基金Postgraduate Innovation Ability Cultivation Funded Project of Hebei Province(Grant No.CXZZBS2021135)Open Project of Hebei Industrial Manipulator Control and reliability Technology Innovation Center,Hebei University of Water Resources and Electric Engineering(Grant No.JXKF2102).
文摘Dyskinesia of the upper limbs caused by stroke,sports injury,or trafc accidents limits the ability to perform the activities of daily living.Besides the necessary medical treatment,correct and scientifc rehabilitation training for the injured joint is an important auxiliary means during the treatment of the efected upper limb.Conventional upperlimb rehabilitation robots have some disadvantages,such as a complex structure,poor compliance,high cost,and poor portability.In this study,a novel soft wearable upper limb rehabilitation robot(SWULRR)with reinforced soft pneumatic actuators(RSPAs)that can withstand high pressure and featuring excellent loading characteristics was developed.Driven by RSPAs,this portable SWULRR can perform rehabilitation training of the wrist and elbow joints.In this study,the kinematics of an SWULRR were analyzed,and the force and motion characteristics of RSPA were studied experimentally.The results provide a reference for the development and application of wearable upper limb rehabilitation robots.An experimental study on the rotation angle of the wrist and the pressure of the RSPA was conducted to test the efect of the rehabilitation training and verify the rationality of the theoretical model.The process of wrist rehabilitation training was tested and evaluated,indicating that SWULRR with RSPAs will enhance the fexibility,comfort,and safety of rehabilitation training.This work is expected to promote the development of wearable upper-limb rehabilitation robots based on modular reinforced soft pneumatic actuators.
基金supported by the High Technology Research and Development Programme of China(No.2004AA421030)
文摘A novel 5-DOF exoskeletal rehabilitation robot for upper limbs of hemiplegic patients caused by stroke is proposed in this paper. Its hardware structure is introduced and the control methods are ana- lyzed. To implement intelligent and interactive rehabilitation exercises, motion intention of patients' up- per limb is introduced into control methods of rehabilitation exercises. In passive motions, according to the character of unilateral impaired, multi-channels surface electromyogram (sEMG) signals of patients' healthy arm muscles are acquired and analyzed to recognize the upper limb motions, then drive the robot and assist paralysis ann's rehabilitation exercises. In active-resistant motions, because patients are re- covered with some muscle forces and active motion ability after a rehabilitation period, the terminal force loaded on the robot by an impaired arm are estimated with multi-channel joint torque sensors, according to which, the terminal velocity of the robot is controlled to drive the joint motions with a damp controller.
基金supported by the National Natural Science Foundation of China ( Grant no. 61272379, 61325018)the Technique Support Project of Jiangsu Province ( Grantno. BE2014132)
文摘Study results in the last decades show that amount and quality of physical exercises,then the active participation,and now the cognitive involvement of patient in rehabilitation training are crucial to enhance recovery outcome of motor dysfunction patients after stroke.Rehabilitation robots mainly have been developed along this direction to satisfy requirements of recovery therapy,or focused on one or more of the above three points.Therefore,rehabilitation robot based on neuro-machine interaction has been proposed for the paralyzed limb training of post-stroke patient,which utilizes motor related EEG,UCSDI(Ultrasound Current Source Density Imaging),EMG for the robot control and feeds back the multi-sensory interaction information such as visual,auditory,force,haptic sensation to the patient simultaneously.This neuro-controlled and perceptual rehabilitation robot will bring great benefits to post-stroke patients.In order to develop such a kind of rehabilitation robot,some key technologies,such as non-invasive precise measurement and decoding of neural signals,realistic sensation feedback,coordinated control for both the rehabilitation robot and the patient,need to be solved.In this paper,some fundamental problems in developing and optimizing such a kind of rehabilitation robot based on neuro-machine interaction are proposed and discussed.
文摘<b><span style="font-family:Verdana;">Background</span></b><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">: </span></b></span></span></span></span><span><span><span><span><span style="font-family:;" "=""><span style="font-family:Verdana;">Active rehabilitation of the paralyzed limb is necessary for functional recovery from upper limb paralysis after stroke. In particular, the </span><span style="font-family:Verdana;">amount of training is very important, and robot rehabilitation is useful. Howev</span><span style="font-family:Verdana;">er, most conventional robots are expensive, large, and stationary. We have d</span><span style="font-family:Verdana;">eveloped Rehabili-Mouse, a new tabletop rehabilitation robot that is compact and portable. The purpose of this study was to conduct paralyzed upper limb training for a patient after stroke using Rehabili-Mouse and to examine its effect.</span></span></span></span></span></span><span><span><span><span><span style="font-family:;" "=""> </span></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Case</span></b></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">: </span></b></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">The patient was a 44-year-old man who had left-sided paresis after a right cerebral infarction, 3 months after onset. The training was carried out between February 2021 and March 2021 at Oyu Rehabilitation Hot</span></span></span></span></span><span><span><span><span><span style="font-family:;" "=""><span style="font-family:Verdana;">spring Hospital. The training was 20 minutes of Rehabili-Mouse in addition to 40 minutes of usual occupational therapy and performed five times a week </span><span style="font-family:Verdana;">for four weeks. Upper limb functions were evaluated before and after the t</span><span style="font-family:Verdana;">raining, and two questionnaires of patient satisfaction with the device and the training were administered after the completion of the training. Upper limb function improved. The patient’s satisfaction with the device was poor, but his satisfaction with the training was good.</span></span></span></span></span></span><span><span><span><span><span style="font-family:;" "=""> </span></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Discussion</span></b></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">: </span></b></span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">Training for the paralyzed upper limb after stroke using Rehabili-Mouse improved upper limb function and satisfied the trained patient. We plan to increase the number of cases and conduct further studies.</span></span></span></span></span>
基金Supported by Science and Technology Department of Anhui Province Regional Innovation Projects and Qiushi Plan(JZ2015QSJH0245)
文摘To achieve human lower limbs rehabilitation training, the exoskeleton lower limbs rehabilitation robot is designed. Through respective motor driving, the retarding mechanism and telescopic adjusting mechanism, the function of human walking is accomplished. After the design of the mechanical structure, the finite element analysis is carried out on the important parts and the control system is achieved by Single Chip Microcomputer.
基金Supported by Science and Technology Department of Anhui province Qiushi Plan(JZ2015QSJH0245)National College Students’Entrepreneurship Practice Project(201410359070)
文摘In this paper, it introduced the mechanical structure design of the multifunctional walking rehabilitation robot, We used the SolidWorks to design and assemble the rehabilitation robot, and optimized the rehabilitation robot based on ergonomics. The result shows that the multifunctional walking rehabilitation robot has the characteristics of complete functions, convenient operation, compact structure and so on. It can meet the requirements of medical care equipment, and effectively complete the nursing work of patients.
基金Guangdong provincial medical science and technology research funding project(No.A2017250)Chinese and western medicine for knee osteoarthritis
文摘Objective:The effect of ankle rehabilitation robot on joint movement of hemiplegic patients was studied and quantitatively evaluated.Methods 90 hemiplegic patients with lower limb dysfunction treated in our hospital from April 2017 to March 2019 were selected as subjects.The patients were randomly divided into two groups:control group(n=45)and observation group(n=45).The patients in the two groups received language training,physiotherapy,exercise therapy,spa,occupational therapy,massage and other comprehensive rehabilitation treatment,on the basis of which the observation group received the auxiliary intervention of ankle rehabilitation robot.The soft tissue compliance of the patients was evaluated by ankle metatarsal flexion moment before and after treatment,the metatarsal flexor tension was evaluated by modified Tardieu scale,and the clinical effect was evaluated by ankle active ankle dorsiflexion.Results After treatment,the ankle flexion angles(0°,10°,20°,30°)in the two groups were significantly lower than those in the control group(P<0.05).Results compared with before treatment,the ankle flexion angles(0°,10°,20°,30°)in the two groups were significantly lower than those in the control group(P<0.05).After treatment,the angle of R1 and R2 measured by modified Tardieu scale of ankle plantar flexor group increased significantly,and the difference of R2-R1 decreased significantly(P<0.05).The improvement degree of the observation group was significantly better than that of the control group(P<0.05).After treatment,the active ankle extension activity of the two groups was significantly higher than that before treatment(P<0.05),and the effective rate of the observation group was significantly higher than that of the observation group(P<0.05).Conclusion Auxiliary intervention with ankle rehabilitation robot system can effectively improve the compliance of ankle soft tissue in spastic hemiplegia,reduce the contracture of metatarsal flexor muscle and improve the disturbance of joint movement in a short time.At the same time,the degree of coordination and acceptance of patients and their families is high,which is an effective means to improve the therapeutic effect.
文摘<span style="font-family:Verdana;"><strong>Background:</strong></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> This study aims to evaluate the effectiveness of the robotic device used in lower limb rehabilitation to reduce motor impairment and improve motor performance in patients with traumatic spinal injury.</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Methods:</span></b></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> The data were obtained by retrospective analysis of patients who underwent lower extremity rehabilitation after traumatic spinal injury by robot-assisted rehabilitation in the hospital between December 2017 and December 2019. The results were statistically analyzed and shown as mean ± SD (min-max).</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Results:</span></b></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> A total of 51 patients with mean age of 59.51 ± 8.2 (38</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">-</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">72) were admitted to the clinic. Mean ages of thirty-one male patients and twenty females patients were 58.74 ± 8.88 (38 - 77) and 60.7 ± 7.09 (44</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">-</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">72), respectively. Comparing ages in terms of gender, it was not statistically significant (p = 0.441). Body mass indexes of male patients were 32.84 ± 6.52 (20 - 48) and 31.4 ± 7.73 (18 - 48) for females. Body mass index of patients was not statistically significant in terms of their gender (p = 0.478). Oswestry disability index scores were 32.04 ± 10.74 (16 - 58) before treatment and 30.69 ± 10.31 (15 - 55) after treatment. Oswestry disability index values before and after robotic rehabilitation were statistically significant (p < 0.001). Significant improvement was observed in ASIA scale values after rehabilitation.</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Conclusions:</span></b></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> The motor function gains obtained during the robot-assisted treatment of traumatic spinal injury patients showed robotic device was useful in the training program. Robotic rehabilitation was effective in the improvement of the lower extremities during motor examination.</span></span></span>
基金Supported by Science and Technology Department of Anhui province Qiushi Plan(JZ2015QSJH0245)National College Students'Entrepreneurship Practice Project(201410359070)
文摘The mechanical structure as well as the schematic organization has been designed to achieve lower limb rehabilitation training function; Solidworks has been used to model the robot. And the robot has been optimized by the means of human-interference engineering. The primary components of the robot have been analyzed by Ansys workbench.
基金Supported by National Natural Science Foundation of China(Grant No.52075145)S&T Program of Hebei Province of China(Grant No.20281805Z)+1 种基金Hebei Provincial Natural Science Foundation of China(Grant No.E2022202130)Central Government Guides Basic Research Projects of Local Science and Technology Development Funds of China(Grant No.206Z1801G).
文摘Aiming at the problem that the existing ankle rehabilitation robot is difficult to fully fit the complex motion of human ankle joint and has poor human-machine motion compatibility,an equivalent series mechanism model that is highly matched with the actual bone structure of the human ankle joint is proposed and mapped into a parallel rehabilita-tion mechanism.The parallel rehabilitation mechanism has two virtual motion centers(VMCs),which can simulate the complex motion of the ankle joint,adapt to the individual differences of various patients,and can meet the reha-bilitation needs of both left and right feet of patients.Firstly,based on the motion properties and physiological structure of the human ankle joint,the mapping relationship between the rehabilitation mechanism and ankle joint is determined,and the series equivalent model of the ankle joint is established.According to the kinematic and con-straint properties of the ankle equivalent model,the configuration design of the parallel ankle rehabilitation robot is carried out.Secondly,according to the intersecting motion planes theory,the full-cycle mobility of the mechanism is proved,and the continuous axis of the mechanism is judged based on the constraint power and its derivative.Then,the kinematics of the parallel ankle rehabilitation robot is analyzed.Finally,based on the OpenSim biomechanical soft-ware,a human-machine coupling rehabilitation simulation model is established to evaluate the rehabilitation effect,which lays the foundation for the formulation of a rehabilitation strategy for the later prototype.
基金approved by the Biomedical Ethics Committee of Hebei University of Technology(NO.HEBUThMEC2022005).
文摘With the increase in the number of stroke patients,there is a growing demand for rehabilitation training.Robot-assisted training is expected to play a crucial role in meeting this demand.To ensure the safety and comfort of patients during rehabilitation training,it is important to have a patient-cooperative compliant control system for rehabilitation robots.In order to enhance the motion compliance of patients during rehabilitation training,a hierarchical adaptive patient-cooperative compliant control strategy that includes patient-passive exercise and patient-cooperative exercise is proposed.A low-level adaptive backstepping position controller is selected to ensure accurate tracking of the desired trajectory.At the high-level,an adaptive admittance controller is employed to plan the desired trajectory based on the interaction force between the patient and the robot.The results of the patient-robot cooperation experiment on a rehabilitation robot show a significant improvement in tracking trajectory,with a decrease of 76.45%in the dimensionless squared jerk(DSJ)and a decrease of 15.38%in the normalized root mean square deviation(NRMSD)when using the adaptive admittance controller.The proposed adaptive patient-cooperative control strategy effectively enhances the compliance of robot movements,thereby ensuring the safety and comfort of patients during rehabilitation training.
基金funded by the National Natural Science Foundation of China,Grant Number:52175006.
文摘This article introduces a cable-driven lower limb rehabilitation robot with movable distal anchor points(M-CDLR).The traditional cable-driven parallel robots(CDPRs)control the moving platform by changing the length of cables,M-CDLR can also adjust the position of the distal anchor point when the moving platform moves.The M-CDLR this article proposed has gait and single-leg training modes,which correspond to the plane and space motion of the moving platform,respectively.After introducing the system structure configuration,the generalized kinematics and dynamics of M-CDLR are established.The fully constrained CDPRs can provide more stable rehabilitation training than the under-constrained one but requires more cables.Therefore,a motion planning method for the movable distal anchor point of M-CDLR is proposed to realize the theoretically fully constrained with fewer cables.Then the expected trajectory of the moving platform is obtained from the motion capture experiment,and the motion planning of M-CDLR under two training modes is simulated.The simulation results verify the effectiveness of the proposed motion planning method.This study serves as a basic theoretical study of the structure optimization and control strategy of M-CDLR.
文摘This study addresses two issues about the interaction of the upper limb rehabilitation robot with individuals who have disabilities.The first step is to estimate the human's target position(also known as TPH).The second step is to develop a robust adaptive impedance control mechanism.A novel Non-singular Terminal Sliding Mode Control combined with an adaptive super-twisting controller is being developed to achieve this goal.This combination's purpose is to provide high reliability,continuous performance tracking of the system's trajectories.The proposed adaptive control strategy reduces matched dynamic uncertainty while also lowering chattering,which is the sliding mode's most glaring issue.The proposed TPH is coupled with adaptive impedance control with the use of a Radial Basis Function Neural Network,which allows a robotic exoskeleton to simply track the desired impedance model.To validate the approach in real-time,an exoskeleton robot was deployed in controlled experimental circumstances.A comparison study has been set up to show how the adaptive impedance approach proposed is better than other traditional controllers.
基金National Natural Science Foundation of China,Grant/Award Numbers:61563032,61963025Science and Technology Program of Gansu Province,Grant/Award Numbers:22CX8GA131,22YF7GA164。
文摘The authors investigate the trajectory tracking control problem of an upper limb reha-bilitation robot system with unknown dynamics.To address the system's uncertainties and improve the tracking accuracy of the rehabilitation robot,an adaptive neural full-state feedback control is proposed.The neural network is utilised to approximate the dy-namics that are not fully modelled and adapt to the interaction between the upper limb rehabilitation robot and the patient.By incorporating a high-gain observer,unmeasurable state information is integrated into the output feedback control.Taking into consider-ation the issue of joint position constraints during the actual rehabilitation training process,an adaptive neural full-state and output feedback control scheme with output constraint is further designed.From the perspective of safety in human–robot interaction during rehabilitation training,log-type barrier Lyapunov function is introduced in the output constraint controller to ensure that the output remains within the predefined constraint region.The stability of the closed-loop system is proved by Lyapunov stability theory.The effectiveness of the proposed control scheme is validated by applying it to an upper limb rehabilitation robot through simulations.