本文制备了平均直径为1.4 nm的11-巯基十一烷酸(Mercaptoundecanoic acid,MUA)修饰的金纳米颗粒,随后通过硅晶片上壳聚糖薄涂层静电吸附制备了厚度约为10 nm的超薄膜,原子力显微镜(Atomic Force Microscopy,AFM)和扫描电子显微镜(Scanni...本文制备了平均直径为1.4 nm的11-巯基十一烷酸(Mercaptoundecanoic acid,MUA)修饰的金纳米颗粒,随后通过硅晶片上壳聚糖薄涂层静电吸附制备了厚度约为10 nm的超薄膜,原子力显微镜(Atomic Force Microscopy,AFM)和扫描电子显微镜(Scanning Electron Microscopy,SEM)表明金纳米颗粒在薄膜中分布较为均匀且薄膜较平整。进一步采用紫外光电子能谱(Ultraviolet Photoelectron Spectroscopy,UPS)研究了不同热处理温度对超薄膜的二次电子发射能力的影响。结果表明,适度的热处理有助于超薄膜二次电子发射强度的提高,尤其是经150°C热处理的薄膜二次电子发射峰强是未处理样品的4倍,更高的热处理温度造成二次电子发射峰强度急剧下降。本文结果有助于推动有机配体金纳米颗粒超薄膜在光电子发射材料方面的应用。展开更多
The vertical cavity surface emitting laser (VCSEL) arrays and VCSEL-based optical transmission modules are investigated.It includes the VCSEL's spectral characteristic,modulation characteristic,high frequency char...The vertical cavity surface emitting laser (VCSEL) arrays and VCSEL-based optical transmission modules are investigated.It includes the VCSEL's spectral characteristic,modulation characteristic,high frequency characteristic,and compatibility with microelectronic circuit.The module consists of 1×16 VCSEL array and 16-channel lasers driver with 0.35μm CMOS circuit by hybrid integration.During the test process,the module operates well at more than 2GHz in -3dB frequency bandwidth.展开更多
In order to build method for measuring of elements in honey, the contents of Ba, Cu, Pb, Cd, As, Hg, Cr, Mn, Se had been determined by microwave diges- tion (MWD) and actively coupled plasma atomic emission spectrom...In order to build method for measuring of elements in honey, the contents of Ba, Cu, Pb, Cd, As, Hg, Cr, Mn, Se had been determined by microwave diges- tion (MWD) and actively coupled plasma atomic emission spectrometry (ICP-AES). The results show that, the range of heavy metal elements were in the range of 0- 10.0 mg/L, with good linear relationship. In addition, all correlation coefficients kept higher than 0.999, and the recovery rate of ample added with standard solution was in 94.1%-110%. By comparison with the result of chemical experiment, the method was quickly accessible and convenient, widely used in the measurement of elements in honey, with satisfactory results.展开更多
In order to develop a method for measuring of elements in Sipunculus nudus, the contents of Cu, Pb, Cd, Cr, Mn, As, Hg and Ba were determined by actively coupled plasma atomic emission spectrometry (MWD) and microwa...In order to develop a method for measuring of elements in Sipunculus nudus, the contents of Cu, Pb, Cd, Cr, Mn, As, Hg and Ba were determined by actively coupled plasma atomic emission spectrometry (MWD) and microwave digestion (ICP-AES). The results showed that correlation coefficients al kept higher than 0.999 and the recovery rates of sample added standard solutions were in 98%-114%. The results indicated that the contents of Cu, Pb, Cd, Cr, Mn, As, Hg and Ba were 17.119, 3.781, 0.695, 7.351, 1997.982, 0.620, 0.144, 4.249 mg/kg respectively. The contents of Mn exceeded national limit by hundredfold, Cd sevenfold, Pd fourfold, Cd three-and-a-half-fold, and As onefold. Sipunculs nudus became seriously pol uted. Therefore, it is necessary to formulate robust policies to fol ow closely and pay close attention to coastal areas pol ution around Dongfang City.展开更多
文摘本文制备了平均直径为1.4 nm的11-巯基十一烷酸(Mercaptoundecanoic acid,MUA)修饰的金纳米颗粒,随后通过硅晶片上壳聚糖薄涂层静电吸附制备了厚度约为10 nm的超薄膜,原子力显微镜(Atomic Force Microscopy,AFM)和扫描电子显微镜(Scanning Electron Microscopy,SEM)表明金纳米颗粒在薄膜中分布较为均匀且薄膜较平整。进一步采用紫外光电子能谱(Ultraviolet Photoelectron Spectroscopy,UPS)研究了不同热处理温度对超薄膜的二次电子发射能力的影响。结果表明,适度的热处理有助于超薄膜二次电子发射强度的提高,尤其是经150°C热处理的薄膜二次电子发射峰强是未处理样品的4倍,更高的热处理温度造成二次电子发射峰强度急剧下降。本文结果有助于推动有机配体金纳米颗粒超薄膜在光电子发射材料方面的应用。
文摘The vertical cavity surface emitting laser (VCSEL) arrays and VCSEL-based optical transmission modules are investigated.It includes the VCSEL's spectral characteristic,modulation characteristic,high frequency characteristic,and compatibility with microelectronic circuit.The module consists of 1×16 VCSEL array and 16-channel lasers driver with 0.35μm CMOS circuit by hybrid integration.During the test process,the module operates well at more than 2GHz in -3dB frequency bandwidth.
文摘In order to build method for measuring of elements in honey, the contents of Ba, Cu, Pb, Cd, As, Hg, Cr, Mn, Se had been determined by microwave diges- tion (MWD) and actively coupled plasma atomic emission spectrometry (ICP-AES). The results show that, the range of heavy metal elements were in the range of 0- 10.0 mg/L, with good linear relationship. In addition, all correlation coefficients kept higher than 0.999, and the recovery rate of ample added with standard solution was in 94.1%-110%. By comparison with the result of chemical experiment, the method was quickly accessible and convenient, widely used in the measurement of elements in honey, with satisfactory results.
文摘In order to develop a method for measuring of elements in Sipunculus nudus, the contents of Cu, Pb, Cd, Cr, Mn, As, Hg and Ba were determined by actively coupled plasma atomic emission spectrometry (MWD) and microwave digestion (ICP-AES). The results showed that correlation coefficients al kept higher than 0.999 and the recovery rates of sample added standard solutions were in 98%-114%. The results indicated that the contents of Cu, Pb, Cd, Cr, Mn, As, Hg and Ba were 17.119, 3.781, 0.695, 7.351, 1997.982, 0.620, 0.144, 4.249 mg/kg respectively. The contents of Mn exceeded national limit by hundredfold, Cd sevenfold, Pd fourfold, Cd three-and-a-half-fold, and As onefold. Sipunculs nudus became seriously pol uted. Therefore, it is necessary to formulate robust policies to fol ow closely and pay close attention to coastal areas pol ution around Dongfang City.