Operability problem of dividing wall column (DWC) raised by vapor split was investigated by numerically analyzing four cases defined by different compositions of a three-component mixture. DWCs were firstly designed f...Operability problem of dividing wall column (DWC) raised by vapor split was investigated by numerically analyzing four cases defined by different compositions of a three-component mixture. DWCs were firstly designed for each case by optimizing the vapor split to the two sides of the dividing wall, and then their feasibilities and total annual costs in operation were evaluated against different vapor split ratios. The analysis on the operability of the DWC for four cases was made based on two scenarios: (1) vapor split is shifted by the vapor resistance difference between the column sections in the two sides of the dividing wall and (2) the feed composition is changed. It was demonstrated that the positioning of the dividing wall and the decision on the vapor split may affect significantly the operability of a DWC.展开更多
Dividing wall column(DWC)is shown to be energy efficient compared to conventional column sequence for multi components separation,which is used for olefin separation in fluidization methanol to propylene process in th...Dividing wall column(DWC)is shown to be energy efficient compared to conventional column sequence for multi components separation,which is used for olefin separation in fluidization methanol to propylene process in the present work.Detailed design for pilot DWC was performed and five control structures,i.e.composition control(CC),temperature control(TC),composition-temperature control(CC-TC),temperature difference control(TDC),double temperature difference control(DTDC)were proposed to circumvent feed disturbance.Sensitivity analysis and singular value decomposition(SVD)were used as criterion to select the controlled temperature locations in TC,CC-TC,TDC and DTDC control loops.The steady simulation result demonstrates that 25.7% and 30.2% duty can be saved for condenser and reboiler by substituting conventional column sequence with DWC,respectively.As for control structure selection,TC and TDC perform better than other three control schemes with smaller maximum deviation and shorter settling time.展开更多
基金Supported by the State Key Fundamental Research Program(2012CB720500)
文摘Operability problem of dividing wall column (DWC) raised by vapor split was investigated by numerically analyzing four cases defined by different compositions of a three-component mixture. DWCs were firstly designed for each case by optimizing the vapor split to the two sides of the dividing wall, and then their feasibilities and total annual costs in operation were evaluated against different vapor split ratios. The analysis on the operability of the DWC for four cases was made based on two scenarios: (1) vapor split is shifted by the vapor resistance difference between the column sections in the two sides of the dividing wall and (2) the feed composition is changed. It was demonstrated that the positioning of the dividing wall and the decision on the vapor split may affect significantly the operability of a DWC.
基金Supported by Open Research Project of State Key Laboratory of Chemical Engineering(Grant No.SKL-Ch E-16B06)
文摘Dividing wall column(DWC)is shown to be energy efficient compared to conventional column sequence for multi components separation,which is used for olefin separation in fluidization methanol to propylene process in the present work.Detailed design for pilot DWC was performed and five control structures,i.e.composition control(CC),temperature control(TC),composition-temperature control(CC-TC),temperature difference control(TDC),double temperature difference control(DTDC)were proposed to circumvent feed disturbance.Sensitivity analysis and singular value decomposition(SVD)were used as criterion to select the controlled temperature locations in TC,CC-TC,TDC and DTDC control loops.The steady simulation result demonstrates that 25.7% and 30.2% duty can be saved for condenser and reboiler by substituting conventional column sequence with DWC,respectively.As for control structure selection,TC and TDC perform better than other three control schemes with smaller maximum deviation and shorter settling time.