Stacking velocity V_(C2),vertical velocity ratio γ_0,effective velocity ratio γ_(eff),and anisotropic parameter x_(eff) are correlated in the PS-converted-wave(PS-wave) anisotropic prestack Kirchhoff time mi...Stacking velocity V_(C2),vertical velocity ratio γ_0,effective velocity ratio γ_(eff),and anisotropic parameter x_(eff) are correlated in the PS-converted-wave(PS-wave) anisotropic prestack Kirchhoff time migration(PKTM) velocity model and are thus difficult to independently determine.We extended the simplified two-parameter(stacking velocity V_(C2) and anisotropic parameter k_(eff)) moveout equation from stacking velocity analysis to PKTM velocity model updating and formed a new four-parameter(stacking velocity V_(C2),vertical velocity ratio γ_0,effective velocity ratio γ_(eff),and anisotropic parameter k_(eff)) PS-wave anisotropic PKTM velocity model updating and process flow based on the simplified twoparameter moveout equation.In the proposed method,first,the PS-wave two-parameter stacking velocity is analyzed to obtain the anisotropic PKTM initial velocity and anisotropic parameters;then,the velocity and anisotropic parameters are corrected by analyzing the residual moveout on common imaging point gathers after prestack time migration.The vertical velocity ratio γ_0 of the prestack time migration velocity model is obtained with an appropriate method utilizing the P- and PS-wave stacked sections after level calibration.The initial effective velocity ratio γ_(eff) is calculated using the Thomsen(1999) equation in combination with the P-wave velocity analysis;ultimately,the final velocity model of the effective velocity ratio γ_(eff) is obtained by percentage scanning migration.This method simplifies the PS-wave parameter estimation in high-quality imaging,reduces the uncertainty of multiparameter estimations,and obtains good imaging results in practice.展开更多
The main cause of dynamic errors is due to frequency response limitation of measurement system. One way of solving this problem is designing an effective inverse filter. Since the problem is ill-conditioned, a small u...The main cause of dynamic errors is due to frequency response limitation of measurement system. One way of solving this problem is designing an effective inverse filter. Since the problem is ill-conditioned, a small uncertainty in the measurement will came large deviation in reconstncted signals. The amplified noise has to be suppressed at the sacrifice of biasing in estimation. The paper presents a kind of designing method of inverse filter in frequency domain based on stabilized solutions of Fredholm integral equations of the fast kind in order to reduce dynamic errors. Compared with previous several work, the method has advantage of generalization. Simulations with different Signal-to-Noise ratio (SNR) are investigated. Flexibility of the method is verified. Application of correcting dynamic error is given.展开更多
基金supported by the Important National Science&Technology Specific Projects(No.2011ZX05019-003)the New Method and Technology Research Project of Geophysical Exploration of CNPC(No.2014A-3612)
文摘Stacking velocity V_(C2),vertical velocity ratio γ_0,effective velocity ratio γ_(eff),and anisotropic parameter x_(eff) are correlated in the PS-converted-wave(PS-wave) anisotropic prestack Kirchhoff time migration(PKTM) velocity model and are thus difficult to independently determine.We extended the simplified two-parameter(stacking velocity V_(C2) and anisotropic parameter k_(eff)) moveout equation from stacking velocity analysis to PKTM velocity model updating and formed a new four-parameter(stacking velocity V_(C2),vertical velocity ratio γ_0,effective velocity ratio γ_(eff),and anisotropic parameter k_(eff)) PS-wave anisotropic PKTM velocity model updating and process flow based on the simplified twoparameter moveout equation.In the proposed method,first,the PS-wave two-parameter stacking velocity is analyzed to obtain the anisotropic PKTM initial velocity and anisotropic parameters;then,the velocity and anisotropic parameters are corrected by analyzing the residual moveout on common imaging point gathers after prestack time migration.The vertical velocity ratio γ_0 of the prestack time migration velocity model is obtained with an appropriate method utilizing the P- and PS-wave stacked sections after level calibration.The initial effective velocity ratio γ_(eff) is calculated using the Thomsen(1999) equation in combination with the P-wave velocity analysis;ultimately,the final velocity model of the effective velocity ratio γ_(eff) is obtained by percentage scanning migration.This method simplifies the PS-wave parameter estimation in high-quality imaging,reduces the uncertainty of multiparameter estimations,and obtains good imaging results in practice.
基金The paper is sponsored by National Natural Science Foundation of China(No.50675211)Natural Science Foundation(No.2009011023)Returned Overseas Graduates Foundation(No.2008067) of Shanxi Provincein China
文摘The main cause of dynamic errors is due to frequency response limitation of measurement system. One way of solving this problem is designing an effective inverse filter. Since the problem is ill-conditioned, a small uncertainty in the measurement will came large deviation in reconstncted signals. The amplified noise has to be suppressed at the sacrifice of biasing in estimation. The paper presents a kind of designing method of inverse filter in frequency domain based on stabilized solutions of Fredholm integral equations of the fast kind in order to reduce dynamic errors. Compared with previous several work, the method has advantage of generalization. Simulations with different Signal-to-Noise ratio (SNR) are investigated. Flexibility of the method is verified. Application of correcting dynamic error is given.