An experimental study on nondestructive X-ray imaging of inner structure of soft tissues in phase con-trast has been conducted with Beijing Synchrotron Radiation Facility (BSRF). Modification to the beamline setupwas ...An experimental study on nondestructive X-ray imaging of inner structure of soft tissues in phase con-trast has been conducted with Beijing Synchrotron Radiation Facility (BSRF). Modification to the beamline setupwas made to enlarge the X-ray beam section and consequently larger samples could be imaged. In-line setup was em-ployed for experiments. Results on a series of samples were given and soft-tissue details of less than 50 μm inside afresh goldfish were obtained. Diagnosis of tumor in its early stage was also investigated taking SD rats as the model.Tumor at the size of ~ 100μm was observed. Potential of this technique in clinic diagnosis was discussed.展开更多
Under three-dimensional plane geometrical constraints ( X,Y,θ ), with two asymmetric achromatic sections, the combined three-section structural FODO-like magnet lattice design is adopted and finely optimized in the S...Under three-dimensional plane geometrical constraints ( X,Y,θ ), with two asymmetric achromatic sections, the combined three-section structural FODO-like magnet lattice design is adopted and finely optimized in the SSRF electron-beam transfer lines. The magnet lattice has high flexibility and robustness, and the Courant–Snyder parameters can be easily adjusted within a wide range to meet the requirements of transmission and injection for different operation modes of the linear accelerator, booster synchrotron, and storage ring. In this article, the main parameters of the linear optics design of the SSRF electron-beam transfer lines are described, involving the physical design criteria, the total geometrical layout, the magnet lattice, and the beam Courant–Snyder parameters matching. The studies of the variant beam dynamic simulation program calculations show that the design purpose of the efficient beam transmission and injection will be basically achieved.展开更多
In the 3rd generation synchrotron light source,beside the orbit,air disturbance and ground vibration also could affect the position stability of photon beam in synchrotrons radiation measurement.In the condition of im...In the 3rd generation synchrotron light source,beside the orbit,air disturbance and ground vibration also could affect the position stability of photon beam in synchrotrons radiation measurement.In the condition of implementation of orbit feedback system at SSRF,the measured position stability of photon beam in synchrotrons radiation measurement station was presented in this paper.And then the improvement methods of position stability of photon beam were discussed.Finally the measured result was shown when the designed feedback system is implemented to improve the position stability of photon beam.展开更多
基金National Natural Science Foundation of China(No.10275087)Shanghai Foundation on Development of Science and Technology(No.022261023) Shanghai Foundation for Natural Science(No.02ZF14116)
文摘An experimental study on nondestructive X-ray imaging of inner structure of soft tissues in phase con-trast has been conducted with Beijing Synchrotron Radiation Facility (BSRF). Modification to the beamline setupwas made to enlarge the X-ray beam section and consequently larger samples could be imaged. In-line setup was em-ployed for experiments. Results on a series of samples were given and soft-tissue details of less than 50 μm inside afresh goldfish were obtained. Diagnosis of tumor in its early stage was also investigated taking SD rats as the model.Tumor at the size of ~ 100μm was observed. Potential of this technique in clinic diagnosis was discussed.
基金Supported by National Important Scientific Project "Shanghai Synchrotron Radiation Facility".
文摘Under three-dimensional plane geometrical constraints ( X,Y,θ ), with two asymmetric achromatic sections, the combined three-section structural FODO-like magnet lattice design is adopted and finely optimized in the SSRF electron-beam transfer lines. The magnet lattice has high flexibility and robustness, and the Courant–Snyder parameters can be easily adjusted within a wide range to meet the requirements of transmission and injection for different operation modes of the linear accelerator, booster synchrotron, and storage ring. In this article, the main parameters of the linear optics design of the SSRF electron-beam transfer lines are described, involving the physical design criteria, the total geometrical layout, the magnet lattice, and the beam Courant–Snyder parameters matching. The studies of the variant beam dynamic simulation program calculations show that the design purpose of the efficient beam transmission and injection will be basically achieved.
基金Supported by Shanghai Synchrotron Radiation Facility project
文摘In the 3rd generation synchrotron light source,beside the orbit,air disturbance and ground vibration also could affect the position stability of photon beam in synchrotrons radiation measurement.In the condition of implementation of orbit feedback system at SSRF,the measured position stability of photon beam in synchrotrons radiation measurement station was presented in this paper.And then the improvement methods of position stability of photon beam were discussed.Finally the measured result was shown when the designed feedback system is implemented to improve the position stability of photon beam.