An experiment of measuring soil moisture was carried out by using dual-frequency microwave radiometer designed by the authors. The measured data were analyzed by using statistical regression method and the empirical r...An experiment of measuring soil moisture was carried out by using dual-frequency microwave radiometer designed by the authors. The measured data were analyzed by using statistical regression method and the empirical regression model of retrieving soil moisture in L-band and C-band was developed. The soil moisture in a rainfall event was retrieved using the experiential regression model, which is consistent well with the field sampling value. The results show that when soil moisture is lower than 75%, the brightness temperature is linear with soil moisture. However, when soil moisture is higher than 75%, the brightness temperature is not linear with soil moisture, so it is difficult for microwave radiometer to measure the changes of soil moisture. The experiment verifies the effectiveness and feasibility of microwave remote sensing soil moisture. Although this method for linear regression based on the data measured with the radiometer is simple, and has strong adaptability, generally it has only local application value, and lacks universal applicability for different areas and different conditions.展开更多
The formula for calculating the threshold of average transmitting power of cylindrical TE11 mode window is revised by accurate deduction and a practical method for calculating the temperature increment of the dielectr...The formula for calculating the threshold of average transmitting power of cylindrical TE11 mode window is revised by accurate deduction and a practical method for calculating the temperature increment of the dielectric disk in cylindrical box type window is given. Meanwhile,a typical cylindrical box type window is calculated and used as an example to discuss the power capacity, the special harmfulness and elimination of ghost mode resonance when the window is used to transmit high power Continuous Wave(CW).展开更多
One of the most important electron density diagnostics, microwave reflectometry, has been developed on many large and medium nuclear fusion devices in recent years . Not only the electron density profiles with high te...One of the most important electron density diagnostics, microwave reflectometry, has been developed on many large and medium nuclear fusion devices in recent years . Not only the electron density profiles with high temporal and spatial resolutions, but also the profiles of plasma rotation and turbulence can be obtained with this diagnostic system.展开更多
This paper rerports a related microwave diagnostic methhod that measures both the electron number density and the electron-neu- tral collision frequency, which are crucial to understand the behavior of microwave trave...This paper rerports a related microwave diagnostic methhod that measures both the electron number density and the electron-neu- tral collision frequency, which are crucial to understand the behavior of microwave traveling in plasma. Arrays of standard commercial fluoresoent lamp placed directly against each other in two rows are used to produce a plasma layer. Attenuations of microwave by plasma layer are studied experimentally in the frequencies of 1--8 C44z using a synthesized signal generator and a spectnnn analyzer. Two wavepolarizations are trader investigation: dectric field of the wave is either parallel ( E -wave) or perpendicular (H-wave) to the fluorescent lamp axis. The electron number density and the electron-neutral collision frequency of fluorescent lamp plasma are obtained by microwave diagnostics, for the purpose of analyzing microwave scattering characteristics by plasma.展开更多
基金Under the auspices of Knowledge Innovation Program of Chinese Academy of Sciences (No. KZCX2-309)
文摘An experiment of measuring soil moisture was carried out by using dual-frequency microwave radiometer designed by the authors. The measured data were analyzed by using statistical regression method and the empirical regression model of retrieving soil moisture in L-band and C-band was developed. The soil moisture in a rainfall event was retrieved using the experiential regression model, which is consistent well with the field sampling value. The results show that when soil moisture is lower than 75%, the brightness temperature is linear with soil moisture. However, when soil moisture is higher than 75%, the brightness temperature is not linear with soil moisture, so it is difficult for microwave radiometer to measure the changes of soil moisture. The experiment verifies the effectiveness and feasibility of microwave remote sensing soil moisture. Although this method for linear regression based on the data measured with the radiometer is simple, and has strong adaptability, generally it has only local application value, and lacks universal applicability for different areas and different conditions.
文摘The formula for calculating the threshold of average transmitting power of cylindrical TE11 mode window is revised by accurate deduction and a practical method for calculating the temperature increment of the dielectric disk in cylindrical box type window is given. Meanwhile,a typical cylindrical box type window is calculated and used as an example to discuss the power capacity, the special harmfulness and elimination of ghost mode resonance when the window is used to transmit high power Continuous Wave(CW).
文摘One of the most important electron density diagnostics, microwave reflectometry, has been developed on many large and medium nuclear fusion devices in recent years . Not only the electron density profiles with high temporal and spatial resolutions, but also the profiles of plasma rotation and turbulence can be obtained with this diagnostic system.
文摘This paper rerports a related microwave diagnostic methhod that measures both the electron number density and the electron-neu- tral collision frequency, which are crucial to understand the behavior of microwave traveling in plasma. Arrays of standard commercial fluoresoent lamp placed directly against each other in two rows are used to produce a plasma layer. Attenuations of microwave by plasma layer are studied experimentally in the frequencies of 1--8 C44z using a synthesized signal generator and a spectnnn analyzer. Two wavepolarizations are trader investigation: dectric field of the wave is either parallel ( E -wave) or perpendicular (H-wave) to the fluorescent lamp axis. The electron number density and the electron-neutral collision frequency of fluorescent lamp plasma are obtained by microwave diagnostics, for the purpose of analyzing microwave scattering characteristics by plasma.