Objectives Although development of new treatment modalities limited digoxin usage, digoxin intoxication is still an important issue which could be easily overlooked. In this report, we analyzed a case series definitiv...Objectives Although development of new treatment modalities limited digoxin usage, digoxin intoxication is still an important issue which could be easily overlooked. In this report, we analyzed a case series definitively diagnosed as digoxin intoxication in the modern era. Methods We analyzed 71 patients hospitalized with digoxin intoxication confirmed by history, complaints, clinical and electrocardiograph (ECG) findings, and serum digoxin levels 〉 2.0 ng/mL, during a five year period. The demographic and clinical data, indications for digoxin use, digoxin dosage, concurrent medications, laboratory data, hospital monitoring, and ECG findings were obtained from all patients. Results Thirty-eight of 71 patients (53.5%) had symptoms of heart failure during admission or later. Sixty-four percent of patients were older than 75 years. The percentage of females was 67%. Atrial fibrillation, hypertension and gastrointestinal complaints were more frequent in the females (64% in females, 30% in males, P = 0.007; 81% in female, 52% in males, P = 0.01; 50% in female, 17.3% in males, P = 0.008, respectively). The mortality rate during the hospital course was 7%. Conclusions This report demonstrated the reduced mortality rates in patients with digoxin intoxication over the study period. Gastrointestinal complaints are the most common symptoms in this population.展开更多
This paper proposes a different method to eliminate base wander and power line interference in electrocardiogram, which introduces the integer coefficient filter theory and gives the detail for designing digital filte...This paper proposes a different method to eliminate base wander and power line interference in electrocardiogram, which introduces the integer coefficient filter theory and gives the detail for designing digital filter to remove these two normal noise signals. Signal from the MIT-BIH electrocardiogram database was used to test the performance of the filter. From the test results, the performance of the digital filer is reDT good. The filter coefficient is an integer number, therefore, the filtering algorithm can be successfully implemented on the microprocessor.展开更多
文摘Objectives Although development of new treatment modalities limited digoxin usage, digoxin intoxication is still an important issue which could be easily overlooked. In this report, we analyzed a case series definitively diagnosed as digoxin intoxication in the modern era. Methods We analyzed 71 patients hospitalized with digoxin intoxication confirmed by history, complaints, clinical and electrocardiograph (ECG) findings, and serum digoxin levels 〉 2.0 ng/mL, during a five year period. The demographic and clinical data, indications for digoxin use, digoxin dosage, concurrent medications, laboratory data, hospital monitoring, and ECG findings were obtained from all patients. Results Thirty-eight of 71 patients (53.5%) had symptoms of heart failure during admission or later. Sixty-four percent of patients were older than 75 years. The percentage of females was 67%. Atrial fibrillation, hypertension and gastrointestinal complaints were more frequent in the females (64% in females, 30% in males, P = 0.007; 81% in female, 52% in males, P = 0.01; 50% in female, 17.3% in males, P = 0.008, respectively). The mortality rate during the hospital course was 7%. Conclusions This report demonstrated the reduced mortality rates in patients with digoxin intoxication over the study period. Gastrointestinal complaints are the most common symptoms in this population.
文摘This paper proposes a different method to eliminate base wander and power line interference in electrocardiogram, which introduces the integer coefficient filter theory and gives the detail for designing digital filter to remove these two normal noise signals. Signal from the MIT-BIH electrocardiogram database was used to test the performance of the filter. From the test results, the performance of the digital filer is reDT good. The filter coefficient is an integer number, therefore, the filtering algorithm can be successfully implemented on the microprocessor.