Based on the gas-liquid two-phase mixture transportation test, the k-c-A; turbulence model was applied to simulate the two-phase turbulent flow in a vortex pump. By comparing the simulation and experiment results, inn...Based on the gas-liquid two-phase mixture transportation test, the k-c-A; turbulence model was applied to simulate the two-phase turbulent flow in a vortex pump. By comparing the simulation and experiment results, inner flow features were revealed. The bubbles in the channel distribute mainly at the pressure side of the blades, and the aggregation degree of the bubbles is enhanced with an increase in inlet gas volume fraction. Experimental results indicate that the influence of the gas phase on vortex pump performance is small when the gas volume fraction is less than 10%. When the gas volume fraction contiuuously increases to 15%, the characteristic curves abruptly drop due to the gas blocking phenomenon.展开更多
Free surface vortex control is vital in a pump sump system because the air absorbed by free surface vortex induc- es noise, vibration, and cavitation corrosion on the pumping system. In this study, the change of free ...Free surface vortex control is vital in a pump sump system because the air absorbed by free surface vortex induc- es noise, vibration, and cavitation corrosion on the pumping system. In this study, the change of free surface vor- tex and air absorption in a pump intake has been investigated by the Volume of Fraction (VOF) method with steady multiphase flow model in order to represent the behavior of the free surface vortex exactly. The homoge- neous free surface model is used to apply interactions of air and water. The results show that air intake by the free surface vortex motion can be visualized using the iso-surface of air volume fraction. The vortices make an air column from the free surface to the pump intake. Also, it was found that the flee surface vortex can be controlled by installing curtain walls.展开更多
基金supported by the National Natural Science Foundation of China (No50879080, No 50609025 and No 50735004)Zhejiang Provincial Key Science Foundation of China (No2008C01024-1 and No2008C21023)
文摘Based on the gas-liquid two-phase mixture transportation test, the k-c-A; turbulence model was applied to simulate the two-phase turbulent flow in a vortex pump. By comparing the simulation and experiment results, inner flow features were revealed. The bubbles in the channel distribute mainly at the pressure side of the blades, and the aggregation degree of the bubbles is enhanced with an increase in inlet gas volume fraction. Experimental results indicate that the influence of the gas phase on vortex pump performance is small when the gas volume fraction is less than 10%. When the gas volume fraction contiuuously increases to 15%, the characteristic curves abruptly drop due to the gas blocking phenomenon.
基金supported by"BK21 Plus project"and"Human Resources Program in Energy Technology"(KETEP)granted financial resource from the Ministry of Trade,Industry&Energy,Republic of Korea.(No.20164010200940)
文摘Free surface vortex control is vital in a pump sump system because the air absorbed by free surface vortex induc- es noise, vibration, and cavitation corrosion on the pumping system. In this study, the change of free surface vor- tex and air absorption in a pump intake has been investigated by the Volume of Fraction (VOF) method with steady multiphase flow model in order to represent the behavior of the free surface vortex exactly. The homoge- neous free surface model is used to apply interactions of air and water. The results show that air intake by the free surface vortex motion can be visualized using the iso-surface of air volume fraction. The vortices make an air column from the free surface to the pump intake. Also, it was found that the flee surface vortex can be controlled by installing curtain walls.