期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
依维莫司生物可吸收血管支架与药物洗脱金属支架在冠状动脉疾病应用中临床结局比较的meta分析(英文)
1
作者 吴献鹏 陆艺 +1 位作者 傅婷婷 胡新央 《心脏杂志》 CAS 2018年第3期309-318,共10页
目的探讨生物可吸收血管支架(everolimus-eluting bioresorbable vascular scaffold,BVS)和依维莫司药物洗脱金属支架(everolimus-eluting metallic stents,EES)在冠状动脉疾病(coronary artery diseases,CAD)应用中的中长期临床结局的m... 目的探讨生物可吸收血管支架(everolimus-eluting bioresorbable vascular scaffold,BVS)和依维莫司药物洗脱金属支架(everolimus-eluting metallic stents,EES)在冠状动脉疾病(coronary artery diseases,CAD)应用中的中长期临床结局的meta分析,为临床决策提供参考依据。方法系统地检阅了电子数据库以及最新国际心血管会议记录,检索时间截止至2018年1月8日,收集已公布相关临床研究的最新随访数据并采用stata 12.0软件进行统计分析。结果最终共纳入11项临床研究,包括7项随机对照试验,总计7 321位患者。meta分析结果显示,BVS组较EES组有更高的明确/极可能支架内血栓(stent/scaffold thrombosis,ST)发生率[比值比(OR)=3.08,95%CI:2.04-4.66,P<0.01],其中早期(OR=2.26,95%CI:1.26-4.03,P=0.006)及极晚期ST(OR=4.46,95%CI:2.01-9.89,P<0.01)发生率均显著高于EES组。BVS植入患者在靶病变失败(OR=1.34,95%CI:1.11 to 1.60,P<0.01)、靶血管心肌梗死(OR=1.71,95%CI:1.31-2.23,P<0.01)、有临床指征的靶病变血运重建(OR=1.51,95%CI:1.15-2.00,P<0.01)以及总心肌梗死(OR=1.52,95%CI:1.22-1.90,P<0.01)的发生率上均较EES组增多。然而,两组在面向患者的复合终点、心因死亡、全因死亡以及全血运重建等发生率上并无显著性差异。结论BVS在冠状动脉疾病应用中的中长期临床结局劣于EES,但仍需更多大型长期临床随机对照试验进一步论证。 展开更多
关键词 依维莫司生物可吸收血管支架 依维莫司药物洗脱金属支架 冠状动脉疾病 支架内血栓 META分析
下载PDF
生物可吸收血管支架在冠心病患者中的应用研究进展
2
作者 毛丹妮 佘强 《临床医学进展》 2023年第5期8203-8209,共7页
生物可吸收血管支架(Bioresorbable vascular scaffold, BVS)是一种新型的支架装置,它提供结构支持和药物释放,以防止早期反冲或再狭窄,然后降解为无毒化合物。可以避免与金属药物洗脱支架(drug-eluting stents, DESs)相关的晚期并发症... 生物可吸收血管支架(Bioresorbable vascular scaffold, BVS)是一种新型的支架装置,它提供结构支持和药物释放,以防止早期反冲或再狭窄,然后降解为无毒化合物。可以避免与金属药物洗脱支架(drug-eluting stents, DESs)相关的晚期并发症。虽然BVS在冠心病患者中应用的优势性已被公认。然而,有研究表明使用BVS时,支架内血栓的发生率也较高,引起了临床广泛关注。因此,为了说明BVS的安全性和有效性,本研究采用文献综述的方法,对国内外生物可吸收血管支架在冠心病患者中的应用研究进展进行综述,以期为临床冠心病缓则支架的选择和相关研究提供借鉴。 展开更多
关键词 生物可吸收血管支架 冠状动脉粥样硬化性心脏病 介入 研究进展
下载PDF
Composite bioabsorbable vascular stents via 3D bio-printing and electrospinning for treating stenotic vessels 被引量:13
3
作者 刘媛媛 向科 +2 位作者 李瑜 陈海萍 胡庆夕 《Journal of Southeast University(English Edition)》 EI CAS 2015年第2期254-258,共5页
A new type of vascular stent is designed for treating stenotic vessels. Aiming at overcoming the shortcomings of existing equipment and technology for preparing a bioabsorbable vascular stent (BVS), a new method whi... A new type of vascular stent is designed for treating stenotic vessels. Aiming at overcoming the shortcomings of existing equipment and technology for preparing a bioabsorbable vascular stent (BVS), a new method which combines 3D bio-printing and electrospinning to prepare the composite bioabsorbable vascular stent (CBVS) is proposed. The inner layer of the CBVS can be obtained through 3D bio- printing using poly-p-dioxanone (PPDO). The thin nanofiber film that serves as the outer layer can be built through electrospinning using mixtures of chitosan-PVA (poly (vinyl alcohol)). Tests of mechanical properties show that the stent prepared through 3D bio-printing combined with electrospinning is better than that prepared through 3D bio- printing alone. Cells cultivated on the CBVS adhere and proliferate better due to the natural, biological chitosan in the outer layer. The proposed complex process and method can provide a good basis for preparing a controllable drug-carrying vascular stent. Overall, the CBVS can be a good candidate for treating stenotic vessels. 展开更多
关键词 3D three-dimensional bio-printing bioabsorbable vascular stent (BVS) ELECTROSPINNING CELLPROLIFERATION composite forming
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部