期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
一种直观判别两个表面色相对偏色的方法
1
作者 杨卫平 曾华 +4 位作者 白凤翔 尚鹤岭 廖宁放 石俊生 余鸿飞 《云南师范大学学报(自然科学版)》 1998年第1期54-57,共4页
本文介绍了一种利用分色差概念,精确计算出两个表面色的相对偏色(解析方法),并在CIELAB色差分析图上直观显示出来(图解法)。亦可根据孟塞尔颜色系统的计算机模型,实现CIELAB色空间到孟塞尔颜色系统的转换,计算出两... 本文介绍了一种利用分色差概念,精确计算出两个表面色的相对偏色(解析方法),并在CIELAB色差分析图上直观显示出来(图解法)。亦可根据孟塞尔颜色系统的计算机模型,实现CIELAB色空间到孟塞尔颜色系统的转换,计算出两个表面色的孟塞尔色相角,从而判断出两个表面色的相对偏色。为生产厂家提供了一种简便、快捷、准确、直观的判别色样偏色的检验手段。 展开更多
关键词 CIELAB 相对偏色 分色差 直观判别 表面色 染色
下载PDF
Determination of Cholesterol Content in Waste Fat by Dual-wavelength Spectrophotometry
2
作者 LIU Jia-di XU Shu-jun +1 位作者 XU Chun-xiang QIN Jin-ping 《Chinese Food Science》 2012年第2期40-42,共3页
[Objective]The aim was to find a way to measure the cholesterol content in deserted oil.[Method]Dual-wavelength spectrophotometry method was used for the determination of cholesterol in edible oil.630 nm and 720 nm we... [Objective]The aim was to find a way to measure the cholesterol content in deserted oil.[Method]Dual-wavelength spectrophotometry method was used for the determination of cholesterol in edible oil.630 nm and 720 nm were set as target band and reference band in this method,respectively.The result was compared to liquid chromatography method.[Result]The relative standard deviation(RSD)was at 1.26% and recovery was between 101.9% and 110.7%.Linear range was 8.0-40.0 μg/ml.The tested result was close to the result of liquid chromatography.[Conclusion]It was proved that this method was easy,fast and accurate.The disturbance of sitosterol was eliminated without isolation.It can be used for fast identification of the authenticity of waste fat. 展开更多
关键词 Dual-wavelength Spectrophotometry Waste fat CHOLESTEROL SITOSTEROL China
下载PDF
A new analytical method for quantifying of sterane and hopane biomarkers 被引量:1
3
作者 WANG HuiTong ZHANG ShuiChang +4 位作者 WENG Na ZHANG Bin WEI XiaoFang YU Han WEI CaiYun 《Science China Earth Sciences》 SCIE EI CAS 2014年第8期1713-1722,共10页
An analytical method for quantifying biomarker compounds of the sterane and the hopane existing in saturated hydrocarbons has been established by using comprehensive two-dimensional gas chromatography-flame ionization... An analytical method for quantifying biomarker compounds of the sterane and the hopane existing in saturated hydrocarbons has been established by using comprehensive two-dimensional gas chromatography-flame ionization detector(GC×GC-FID) with optimized operating parameters. The new method achieves the quantification by using a GC×GC-FID system which is able to completely separate steranes from hopanes. The data obtained by the new method are of good repeatability and reliability. Compared with the original data, the relative standard deviations(RSDs) of 12 reference compounds are less than 5%. The RSDs of the quantitative results of the biomarkers based on seven separate analyses are also less than 5%. Compared with the traditional method of gas chromatography-mass spectrometry(GC-MS), the new method has a number of advantages, such as common internal standards(ISs), high resolution, no co-eluting peak, and no interference caused by diagnostic ion peaks. The new method provides petroleum geologists with an effective and scientific means in future researches. 展开更多
关键词 comprehensive two-dimensional gas chromatography (GCxGC) flame ionization detector (FID) time-of.flight massspectrometry (TOFMS) saturated hydrocarbon biomarker compounds quantification STERANE HOPANE
原文传递
上一页 1 下一页 到第