To determine and calculate the stable fluidization zone in a magnetically fluidized bed, the fluidization characteristics of magnetic particles are investigated. Four kinds of magnetic particles with different average...To determine and calculate the stable fluidization zone in a magnetically fluidized bed, the fluidization characteristics of magnetic particles are investigated. Four kinds of magnetic particles with different average diameters, ranging from 231 to 512 μm, are fluidized in the presence of magnetic fields with specified values of the intensity in the range of zero to 7330 A/m, and the particle fluidization curves are plotted. For marking the stable fluidization zone in the curves, the minimum bubbling velocities of particles are measured by the pressure-drop fluctuation. Based on the fluidization curves, the influences of the average particle diameter and magnetic field intensity on the zone are analyzed and discussed. A correlation to determine the stable fluidization zone is derived from the experimental data, using three dimensionless numbers, i. e., the ratio of magnetic potential to gravity potential, the Reynolds number and the Archimedes number. Compared with available data reported, it is shown that the correlation is more simplified to predict relative parameters for the bed operating in the state of stable fluidization under reasonable conditions.展开更多
In order to study the settling mechanism of particles in an air-solid magnetically stabilized fluidized bed(MSFB) for separation,we carried out free settling and quasi-zero settling tests on the tracing particles.The ...In order to study the settling mechanism of particles in an air-solid magnetically stabilized fluidized bed(MSFB) for separation,we carried out free settling and quasi-zero settling tests on the tracing particles.The results show that the main resistance forces as the tracing particles settled in an air-solid MSFB were motion resistance force and yield force.The motion resistance and yield forces greatly hindered the free settling of the particles by greatly decreasing the acceleration for settling process of the particles.The acceleration decreased from 3022.62 cm/s 2 to zero in 0.1 s,and in the end,the particles stopped in the air-solid MSFB.The yield force on particles increased with increasing the magnetic field intensity,resulting in decrease of the quasi-zero settling displacement.However,the yield force on particles decreased with increasing the fluidized air velocity,leading to increase of the quasi-zero settling displacement.When the structure and operating parameters of the air-solid MSFB were set up,the yield stress on particles stopped in an air-solid MSFB was a function of diameter and density of particles.The settling displacements of equal diameter particles increased with increasing their densities,and the settling displacements of equal density particles increased with increasing their diameters.展开更多
To enhance the bioregeneration of Fe(II)EDTA and to avoid the inhibition of the components in nitrogen oxides(NOx) scrubbing solution, a novel integrated process of metal chelate absorption and two-stage bioreduction ...To enhance the bioregeneration of Fe(II)EDTA and to avoid the inhibition of the components in nitrogen oxides(NOx) scrubbing solution, a novel integrated process of metal chelate absorption and two-stage bioreduction was developed. In this process, magnetically stabilized fluidized beds(MSFB) were used as the bioreactors, and the phase diagram for the MSFB operation was determined. Factors including inlet NO, O2 and SO2 concentrations, magnetic field intensity, gas flow rate and liquid circulation rate, were studied experimentally to investigate their effects on NO removal. In addition, a mathematical model for NO removal in this integrated system was developed. The results revealed that the integrated system could be steadily operated with a high NO removal efficiency and elimination capacity, even under the condition of high NO and O2 shock-loading. The established model showed that NO removal efficiency was related to the spray column property and the active Fe(II)EDTA concentration, while the latter depends on the bioregeneration of the disabled absorbent in the MSFB.展开更多
基金The National Natural Science Foundation of China(No50576013)
文摘To determine and calculate the stable fluidization zone in a magnetically fluidized bed, the fluidization characteristics of magnetic particles are investigated. Four kinds of magnetic particles with different average diameters, ranging from 231 to 512 μm, are fluidized in the presence of magnetic fields with specified values of the intensity in the range of zero to 7330 A/m, and the particle fluidization curves are plotted. For marking the stable fluidization zone in the curves, the minimum bubbling velocities of particles are measured by the pressure-drop fluctuation. Based on the fluidization curves, the influences of the average particle diameter and magnetic field intensity on the zone are analyzed and discussed. A correlation to determine the stable fluidization zone is derived from the experimental data, using three dimensionless numbers, i. e., the ratio of magnetic potential to gravity potential, the Reynolds number and the Archimedes number. Compared with available data reported, it is shown that the correlation is more simplified to predict relative parameters for the bed operating in the state of stable fluidization under reasonable conditions.
基金supported by the National Natural Science Foundation of China (Nos. 51134022 and 51174203)the Key Project of Chinese National Programs for Fundamental Research and Development (No. 2012CB214904)+2 种基金the National Natural Science Foundation of China for Innovative Research Group (No. 50921002)the Natural Science Foundation of Jiangsu Province (No. BK2010002)the Fundamental Research Funds for the Central Universities (Nos. 2010QNB11 and 2010ZDP01A06)
文摘In order to study the settling mechanism of particles in an air-solid magnetically stabilized fluidized bed(MSFB) for separation,we carried out free settling and quasi-zero settling tests on the tracing particles.The results show that the main resistance forces as the tracing particles settled in an air-solid MSFB were motion resistance force and yield force.The motion resistance and yield forces greatly hindered the free settling of the particles by greatly decreasing the acceleration for settling process of the particles.The acceleration decreased from 3022.62 cm/s 2 to zero in 0.1 s,and in the end,the particles stopped in the air-solid MSFB.The yield force on particles increased with increasing the magnetic field intensity,resulting in decrease of the quasi-zero settling displacement.However,the yield force on particles decreased with increasing the fluidized air velocity,leading to increase of the quasi-zero settling displacement.When the structure and operating parameters of the air-solid MSFB were set up,the yield stress on particles stopped in an air-solid MSFB was a function of diameter and density of particles.The settling displacements of equal diameter particles increased with increasing their densities,and the settling displacements of equal density particles increased with increasing their diameters.
基金sponsored by the National Natural Science Foundation of China(21077035)the Program for New Century Excellent Talents in the University of China(NCET-11-0851)the Promotion Program for Young and Middle-aged Teacher of Huaqiao University(ZQN-YX104)
文摘To enhance the bioregeneration of Fe(II)EDTA and to avoid the inhibition of the components in nitrogen oxides(NOx) scrubbing solution, a novel integrated process of metal chelate absorption and two-stage bioreduction was developed. In this process, magnetically stabilized fluidized beds(MSFB) were used as the bioreactors, and the phase diagram for the MSFB operation was determined. Factors including inlet NO, O2 and SO2 concentrations, magnetic field intensity, gas flow rate and liquid circulation rate, were studied experimentally to investigate their effects on NO removal. In addition, a mathematical model for NO removal in this integrated system was developed. The results revealed that the integrated system could be steadily operated with a high NO removal efficiency and elimination capacity, even under the condition of high NO and O2 shock-loading. The established model showed that NO removal efficiency was related to the spray column property and the active Fe(II)EDTA concentration, while the latter depends on the bioregeneration of the disabled absorbent in the MSFB.