5-Fluorouracil (5-FU) has a broad spectrum of anti-tumor activity, widely applied to the treatment of cancers. However, it is necessary to determine the plasma concentration of 5-FU in clinical practice due to its nar...5-Fluorouracil (5-FU) has a broad spectrum of anti-tumor activity, widely applied to the treatment of cancers. However, it is necessary to determine the plasma concentration of 5-FU in clinical practice due to its narrow therapeutic index. Therefore, a simple, economic and sensitive high-performance liquid chromatography (HPLC) method was developed and validated for the determination of 5-FU in human plasma. Ethyl acetate was chosen as extraction reagent. Chromatographic separation was performed on a Diamonsil C18 column (250 mm × 4.6 mm i.d., 5 μm) with the mobile phase consisting of methanol and 20 mmol/L ammonium formate using a linear gradient elution at a flow rate of 0.8 mL/min. 5-FU and 5-bromouracil (5-BU) were detected by UV detector at 265 nm. The calibration curve was linear over the concentration range of 5—500 ng/mL and the correlation coefficient was not less than 0.992 6 for all calibration curves. The intra- and inter-day precisions were less than 10.5% and 4.3%, respectively, and the accuracy was within ±3.7%. The recovery at all concentration levels was 80.1±8.6%. 5-FU was stable under possible conditions of storing and handling. This method is proved applicable to therapeutic drug monitoring and pharmacokinetic studies of 5-FU in human.展开更多
A method was developed for the analysis of hydroxylated brominated diphenyl ethers (OH-PBDEs) in plant samples using an ultra performance liquid chromatography-triple quadrupole mass spectrometer (UPLC-ESI-MS/MS) in n...A method was developed for the analysis of hydroxylated brominated diphenyl ethers (OH-PBDEs) in plant samples using an ultra performance liquid chromatography-triple quadrupole mass spectrometer (UPLC-ESI-MS/MS) in negative mode. Plant samples were extracted and cleaned up through florisil column, resolved on a 100 mm C18 column with linear gradient elution and detected by mass spectrometry in multiple reaction monitoring (MRM) mode. The method provided good recoveries rang- ing from 68.2% to 94.6%, relative standard deviation (RSD) in the range of 3.2% - 9.1%, and limits of quantification (LOQ) defined as the signal-to-noise ratio of 10 of 0.3-2.1 ng/g. It allowed a fast separation and sensitive quantification of the isomers and homologues of seven OH-PBDE congeners 2′-OH-BDE-3, 3′-OH-BDE-7, 4′-OH-BDE-17, 3′-OH-BDE-28, 3-OH-BDE-47, 5-OH-BDE-47 and 6-OH-BDE-47. The method was successfully applied to identify and quantify the formation of hydroxylat- ed metabolites in alfalfa exposed to BDE-209. Five OH-PBDEs were detected in plant tissues, and more congeners were found in roots than in shoots. To our knowledge, this work represents the first attempt to validate UPLC-MS/MS method to quantify OH-PBDEs in plant samples without derivatization.展开更多
基金Supported by National Natural Science Foundation of China (No. 30630075 and 20675056)Major State Basic Research Development Program of China ("973" Program) (No. 2006CB933303)
文摘5-Fluorouracil (5-FU) has a broad spectrum of anti-tumor activity, widely applied to the treatment of cancers. However, it is necessary to determine the plasma concentration of 5-FU in clinical practice due to its narrow therapeutic index. Therefore, a simple, economic and sensitive high-performance liquid chromatography (HPLC) method was developed and validated for the determination of 5-FU in human plasma. Ethyl acetate was chosen as extraction reagent. Chromatographic separation was performed on a Diamonsil C18 column (250 mm × 4.6 mm i.d., 5 μm) with the mobile phase consisting of methanol and 20 mmol/L ammonium formate using a linear gradient elution at a flow rate of 0.8 mL/min. 5-FU and 5-bromouracil (5-BU) were detected by UV detector at 265 nm. The calibration curve was linear over the concentration range of 5—500 ng/mL and the correlation coefficient was not less than 0.992 6 for all calibration curves. The intra- and inter-day precisions were less than 10.5% and 4.3%, respectively, and the accuracy was within ±3.7%. The recovery at all concentration levels was 80.1±8.6%. 5-FU was stable under possible conditions of storing and handling. This method is proved applicable to therapeutic drug monitoring and pharmacokinetic studies of 5-FU in human.
基金funded by the National Natural Science Foundation of China (40730740 & 20921063)the National Basic Research Program of China (2009CB421603)
文摘A method was developed for the analysis of hydroxylated brominated diphenyl ethers (OH-PBDEs) in plant samples using an ultra performance liquid chromatography-triple quadrupole mass spectrometer (UPLC-ESI-MS/MS) in negative mode. Plant samples were extracted and cleaned up through florisil column, resolved on a 100 mm C18 column with linear gradient elution and detected by mass spectrometry in multiple reaction monitoring (MRM) mode. The method provided good recoveries rang- ing from 68.2% to 94.6%, relative standard deviation (RSD) in the range of 3.2% - 9.1%, and limits of quantification (LOQ) defined as the signal-to-noise ratio of 10 of 0.3-2.1 ng/g. It allowed a fast separation and sensitive quantification of the isomers and homologues of seven OH-PBDE congeners 2′-OH-BDE-3, 3′-OH-BDE-7, 4′-OH-BDE-17, 3′-OH-BDE-28, 3-OH-BDE-47, 5-OH-BDE-47 and 6-OH-BDE-47. The method was successfully applied to identify and quantify the formation of hydroxylat- ed metabolites in alfalfa exposed to BDE-209. Five OH-PBDEs were detected in plant tissues, and more congeners were found in roots than in shoots. To our knowledge, this work represents the first attempt to validate UPLC-MS/MS method to quantify OH-PBDEs in plant samples without derivatization.