An optical technique for 3 D shape measurement is presented. This technique, based on a deformed projected grating pattern which carries 3 D information of the measured object, can automatically and accurately obtain ...An optical technique for 3 D shape measurement is presented. This technique, based on a deformed projected grating pattern which carries 3 D information of the measured object, can automatically and accurately obtain the phase map of a measured object by using one step phase shift algorithm.In comparison with traditional phase shift technique, the technique is much faster, with the equivalent accuracy. Only one frame image is sufficient for measuring. Experimental result of typical object is presented.展开更多
A new method of 360° turning 3D shape measurement in which light sectioning and phase shifting techniques are both used is presented in this paper.A sine light field is applied in the projected light stripe,meanw...A new method of 360° turning 3D shape measurement in which light sectioning and phase shifting techniques are both used is presented in this paper.A sine light field is applied in the projected light stripe,meanwhile phase shifting technique is used to calculate phase of the light slit.Thereafter wrapped phase distribution of the slit is formed and the unwrapping process will be made by means of the height information based on the light sectioning method.Therefore phase measuring results with better precision can be obtained.At last the target 3D shape data can be produced according to geometric relationships between phases and the object heights.The principles of this method are discussed in detail and experimental results are shown in this paper.展开更多
A simple and rapid method for the determination of polyethylene oxide-type non-ionic surfactants is reported herein. This method is based on the adhesion of calcium/non-ionic surfactant complexes with tetra phenyl por...A simple and rapid method for the determination of polyethylene oxide-type non-ionic surfactants is reported herein. This method is based on the adhesion of calcium/non-ionic surfactant complexes with tetra phenyl porphine sulfonic acid (TPPS) to the wall of reaction vessel upon vigorous shaking. The ion-associate adhering to the inner wall of the vessel was dissolved with water after discarding the solution and spectrophotometrically assayed at 412 nm. From the standard curve for Triton X-100, the order of the sensitivity for different ions was as follows: Ca^2+〉 K^+〉 NH4^+〉 Ba^2+. The proposed method does not involve extraction of the ion-associated with harmful solvents and can be simply performed by combining a procedure based on hand shaking and the use of a spectrophotometer.展开更多
文摘An optical technique for 3 D shape measurement is presented. This technique, based on a deformed projected grating pattern which carries 3 D information of the measured object, can automatically and accurately obtain the phase map of a measured object by using one step phase shift algorithm.In comparison with traditional phase shift technique, the technique is much faster, with the equivalent accuracy. Only one frame image is sufficient for measuring. Experimental result of typical object is presented.
文摘A new method of 360° turning 3D shape measurement in which light sectioning and phase shifting techniques are both used is presented in this paper.A sine light field is applied in the projected light stripe,meanwhile phase shifting technique is used to calculate phase of the light slit.Thereafter wrapped phase distribution of the slit is formed and the unwrapping process will be made by means of the height information based on the light sectioning method.Therefore phase measuring results with better precision can be obtained.At last the target 3D shape data can be produced according to geometric relationships between phases and the object heights.The principles of this method are discussed in detail and experimental results are shown in this paper.
文摘A simple and rapid method for the determination of polyethylene oxide-type non-ionic surfactants is reported herein. This method is based on the adhesion of calcium/non-ionic surfactant complexes with tetra phenyl porphine sulfonic acid (TPPS) to the wall of reaction vessel upon vigorous shaking. The ion-associate adhering to the inner wall of the vessel was dissolved with water after discarding the solution and spectrophotometrically assayed at 412 nm. From the standard curve for Triton X-100, the order of the sensitivity for different ions was as follows: Ca^2+〉 K^+〉 NH4^+〉 Ba^2+. The proposed method does not involve extraction of the ion-associated with harmful solvents and can be simply performed by combining a procedure based on hand shaking and the use of a spectrophotometer.