The resonator fiber optic gyro (R-FOG) ,which utilizes a resonance frequency change due to the Sagnac effect,is a promising candidate for the next generation inertial rotation sensor. In this study, an open-loop R-F...The resonator fiber optic gyro (R-FOG) ,which utilizes a resonance frequency change due to the Sagnac effect,is a promising candidate for the next generation inertial rotation sensor. In this study, an open-loop R-FOG is set up using phase modulation spectroscopy. First,the demodulation curve is obtained using a lock-in amplifier. From the demodulation signal,a gyro dynamic range of ± 4.2rad/s is obtained. Then,using different phase modulation frequencies,the open-loop gyro output signal is measured when the gyro is rotated clockwise or counterclockwise. The bias drift as a function of time is also measured. The fluctuation of the output over 5s is about 0.02rad/s. The drift can be reduced by taking countermeasures against system noise.展开更多
文摘The resonator fiber optic gyro (R-FOG) ,which utilizes a resonance frequency change due to the Sagnac effect,is a promising candidate for the next generation inertial rotation sensor. In this study, an open-loop R-FOG is set up using phase modulation spectroscopy. First,the demodulation curve is obtained using a lock-in amplifier. From the demodulation signal,a gyro dynamic range of ± 4.2rad/s is obtained. Then,using different phase modulation frequencies,the open-loop gyro output signal is measured when the gyro is rotated clockwise or counterclockwise. The bias drift as a function of time is also measured. The fluctuation of the output over 5s is about 0.02rad/s. The drift can be reduced by taking countermeasures against system noise.