A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the...A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the non-uniform distribution of ultimate stress in cored concrete.The accuracy of the analytical result is validated through running the numerical result by finite element method (FEM) and experimental data as well.The influences of the key parameters on the load capacity of the concrete-filled steel tube (CFST) was studied,including the separation ratio,concrete compressive strength,and steel strength.The results indicate that the load capacity of the tube increases with concrete strength and steel strength under the separation ratio less than 4%,while decreases with a higher separation ratio improved.展开更多
In order to find out the bearing behavior of super-long piles located in deep soft clay over stiff layers around Dongting Lake, China, a test pile was first designed with the field loading test finished afterward. Bas...In order to find out the bearing behavior of super-long piles located in deep soft clay over stiff layers around Dongting Lake, China, a test pile was first designed with the field loading test finished afterward. Based on the measured test results, load transfer mechanism and bearing behavior of the pile shaft were discussed in detail. Then, by introducing a bi-linear model for shaft friction and the tri-linear model for pile tip resistance, respectively, the governing differential equation of pile soil system was set up by the load transfer method with the analytical solutions derived as well, taking into account the effect by stratified feature and various bearing conditions of subsoil, material nonlinearity, and the sediment under pile tip. Furthermore, formulas to determine the axial capacity of super-long piles by the pile top settlement were advised and applied to analyze the test pile. Good agreement between the predicted load settlement variations and the measured data is obtained to verify the validity of the present method. The results also show that, the axial bearing capacity of super-long piles should be controlled by the allowable pile top settlement, and buckling stability of the pile shaft should be paid attention as well.展开更多
基金Projects(51078093,11272095)supported by the National Natural Science Foundation of ChinaProjects(2011B010300026,2012B04032005)supported by Guangdong Science and Technology Project,China+1 种基金Project(2011Y2-00006)supported by Guangzhou City Science and Technology Research Project,ChinaProject(2012CXZD0028)supported by the Science and Technology Innovation Projects of Department of Education of Guangdong Province,China
文摘A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the non-uniform distribution of ultimate stress in cored concrete.The accuracy of the analytical result is validated through running the numerical result by finite element method (FEM) and experimental data as well.The influences of the key parameters on the load capacity of the concrete-filled steel tube (CFST) was studied,including the separation ratio,concrete compressive strength,and steel strength.The results indicate that the load capacity of the tube increases with concrete strength and steel strength under the separation ratio less than 4%,while decreases with a higher separation ratio improved.
基金Project(50908084)supported by the National Natural Science Foundation of ChinaProject(200815)supported by the Transportation Science and Technology Program of Hunan Province,ChinaProject(531107040620)supported by the Growth Plan for Young Teachers of Hunan University,China
文摘In order to find out the bearing behavior of super-long piles located in deep soft clay over stiff layers around Dongting Lake, China, a test pile was first designed with the field loading test finished afterward. Based on the measured test results, load transfer mechanism and bearing behavior of the pile shaft were discussed in detail. Then, by introducing a bi-linear model for shaft friction and the tri-linear model for pile tip resistance, respectively, the governing differential equation of pile soil system was set up by the load transfer method with the analytical solutions derived as well, taking into account the effect by stratified feature and various bearing conditions of subsoil, material nonlinearity, and the sediment under pile tip. Furthermore, formulas to determine the axial capacity of super-long piles by the pile top settlement were advised and applied to analyze the test pile. Good agreement between the predicted load settlement variations and the measured data is obtained to verify the validity of the present method. The results also show that, the axial bearing capacity of super-long piles should be controlled by the allowable pile top settlement, and buckling stability of the pile shaft should be paid attention as well.