[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by ga...[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.展开更多
The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar co...The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar compounds.This study introduces an optimized twin-column recycling chromatography method for the efficient and simultaneous purification of these elusive constituents.By introducing water at a small flowing rate between the twin columns,a step solvent gradient is created,by which the leading edge of concentration band would migrate at a slower rate than the trailing edge as it flowing from the upstream to downstream column.Hence,the band broadening is counterbalanced,resulting in an enrichment effect for those minor components in separation process.Herein,two target substances,which showed similar peak position in high performance liquid chromatography(HPLC)and did not exceed 1.8%in crude paclitaxel were selected as target compounds for separation.By using the twin-column recycling chromatography with a step solvent gradient,a successful purification was achieved in getting the two with the purity almost 100%.We suggest this method is suitable for the separation of most components in natural produces,which shows higher precision and recovery rate compared with the common lab-operated separation ways for natural products(thin-layer chromatography and prep-HPLC).展开更多
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc...In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.展开更多
Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant propertie...Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant properties of Gymnema sylvestre extracts.Ethanolic reflux extraction followed by column chromatography was employed to isolate phenolic compounds.The total phenolic and flavonoid contents were quantified using the Folin–Ciocalteu and aluminum chloride colorimetric methods,respectively.Antioxidant activities were assessed by DPPH,ABTS scavenging assays and the ferric reducing antioxidant power(FRAP)assay.High-Performance Liquid Chromatography(HPLC)with a C18 column and Thermo TSQ Quantum Access Max(LC-MS)were used to determine the levels of gymnemic acid and identify other potential phenolic compounds.The analysis revealed significant antioxidant activities in the fractions.Fraction A showed the highest DPPH and ABTS scavenging activities,and Fraction C demonstrated the highest ferric reducing power.LC-MS analysis identified several phenolic compounds,indicating that these are major contributors to the antioxidant efficacy of the extract.This study provides a detailed phenolic profile and confirms the strong antioxidant potential of Gymnema sylvestre leaf extract,supporting its therapeutic use and further investigation.展开更多
The low temperature coal tar(CT)is taken as the raw material,and the extraction and column chromatography are used for detailed and accurate characterization in this paper.The n-heptane soluble fraction(CT-HS)and inso...The low temperature coal tar(CT)is taken as the raw material,and the extraction and column chromatography are used for detailed and accurate characterization in this paper.The n-heptane soluble fraction(CT-HS)and insoluble fraction(CT-HI)were obtained by n-heptane Soxhlet extraction.The extraction rate of CT-HS reached 92.79%(mass),which indicated that there are few heavy compounds in it.Further,different solvents(methylbenzene,benzene,ethyl acetate,methylbenzene-ethanol)were used to elute CT-HS by chromatographic column to obtain five fractions(saturates,aromatics,heteroatoms,phenolics and resins,named CT-SA,CT-AR,CT-HE,CT-PH,CT-RE,respectively).The yields of CTSA,CT-AR,CT-HE,CT-PH,CT-RE are 42.12%,10.43%,2.19%,9.50%and 6.63%(mass),respectively.Gas chromatography-mass spectrometry analysis of eluting components show that alkanes are the main components in CT,followed by polycyclic aromatics,and the corresponding fractions are CT-SA and CT-AR,respectively.The relative content of aliphatics in CT-SA is 76.93%,and the relative content of aromatics in CT-AR is 75.05%.This separation technology effectively separates and enriches different components in CT,and the activation energy required for the pyrolysis process of a single eluting fraction is lower than that of CT,which is expected to provide an important reference for the separation,analysis and conversion of complex oil products such as coal-oil co-processing products,coal tar and other complex heavy carbon oil products.展开更多
The novel pulsed liquid chromatography radionuclide separation method presented here provides a new and promising strategy for the extraction of uranium from seawater.In this study,a new chromatographic separation met...The novel pulsed liquid chromatography radionuclide separation method presented here provides a new and promising strategy for the extraction of uranium from seawater.In this study,a new chromatographic separation method was proposed,and a pulsed nuclide automated separation device was developed,alongside a new chromatographic column.The length of this chromatographic column was 10 m,with an internal warp of 3 mm and a packing size of 1 mm,while the total separation units of the column reached 12,250.The most favorable conditions for the separation of nuclides were then obtained through optimizing the separation conditions of the device:Sample pH in the column=2,sample injection flow rate=5.698 mL/min,chromatographic column heating temperature=60℃.Separation experiments were also carried out for uranium,europium,and sodium ions in mixed solutions;uranium and sodium ions in water samples from the Ganjiang River;and uranium,sodium,and magnesium ions from seawater samples.The separation factors between the different nuclei were then calculated based on the experimental data,and a formula for the separation level was derived.The experimental results showed that the separation factor in the mixed solution of uranium and europium(1:1)was 1.088,while achieving the initial separation of uranium and europium theoretically required a 47-stage separation.Considering the separation factor of 1.50for the uranium and sodium ions in water samples from the Ganjiang River,achieving the initial separation of uranium and sodium ions would have theoretically required at least a 21-stage separation.Furthermore,for the seawater sample separation experiments,the separation factor of uranium and sodium ions was 1.2885;therefore,more than 28 stages of sample separation would be required to achieve uranium extraction from seawater.The novel pulsed liquid chromatography method proposed in this study was innovative in terms of uranium separation and enrichment,while expanding the possibilities of extracting uranium from seawater through chromatography.展开更多
[Objectives] To establish the process flow of preparation of Wufang Babu Poultice and the identification method of thin layer chromatography (TLC). [Methods] For the forming process of Wufang Babu Poultice, the prepar...[Objectives] To establish the process flow of preparation of Wufang Babu Poultice and the identification method of thin layer chromatography (TLC). [Methods] For the forming process of Wufang Babu Poultice, the preparation method of mixed pharmaceutical powder with suitable pharmaceutical excipients was adopted. Qualitative identification of medicinal materials in Wufang Babu Poultice (Strychni Semen, Rhei Radix Et Rhizoma, Dipsaci Radix, and Angelicae Sinensis Radix) was carried out by TLC. [Results] Mixed pharmaceutical powder mixed with glycerol, gelatin and other pharmaceutical excipients can be prepared for forming. The test solution chromatography of each medicinal material (Strychni Semen, Rhei Radix et Rhizoma, Dipsaci Radix, Angelicae Sinensis Radix) showed pigment spots of the same color at the same position as its corresponding control medicinal materials and reference chromatography, and the display was clear. [Conclusions] The preparation process is simple and feasible, and can be used as the forming process of Wufang Babu Poultice. The TLC determination method is simple to operate, has good specificity, and has no effect on negative results, and can be used for identification of Wufang Babu Poultice.展开更多
A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with flucona...A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with fluconazole as an Internal Standard and directed to protein precipitation and drug extraction. An aliquot of 1 μl was injected into the chromatographic system and separated by the Acquity BEH C18 column at a flow rate of 0.30 ml/min in a gradient mobile phase consisting of acetonitrile, Ultrapure water (UPW), methanol and formic acid. Voriconazole was detected by a Triple Quadrupole Detector (TQD) operating on Multiple Reaction Monitoring (MRM) and a positive ion mode Electrospray ionization (ESI) Q1 mass: 350.1 m/z, Q3 mass: 281.1 m/z. Method linearity of the calibration curve (0.10 - 8.00 μg/ml) indicated a correlation coefficient r ≥ 0.99. The intra and inter-assay accuracy was within 85% - 115% and the intra and inter-assay precision was ≤5.76%. Voriconazole recovery percentage was between 97.69 - 119.62%. The method was successively applied in routine voriconazole TDM.展开更多
The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, a...The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R2> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection.展开更多
Applications of pyrolysis-gas chromatography and pyrolysis capillary gas chromatography in explosive and propellant analysis are reviewed, including the identification of explosives and propel- lants, the investigatio...Applications of pyrolysis-gas chromatography and pyrolysis capillary gas chromatography in explosive and propellant analysis are reviewed, including the identification of explosives and propel- lants, the investigation of the thermal decomposition of nitrocellulose (NC), cyclotetramethylene tetranitramine (HMX)and cyclotrimethylene trinitramine (RDX), and the study of the wear- reducing mechanism of polyurethane additive in propellant gain.展开更多
Aim A novel method has been developed for evaluation of the levels of total residual protein in antibiotics produced by fermentation using gel filtration chromatography (GFC) combined with Bradford assay based on dete...Aim A novel method has been developed for evaluation of the levels of total residual protein in antibiotics produced by fermentation using gel filtration chromatography (GFC) combined with Bradford assay based on determination of residual protein in lincomycin hydrochloride. Methods The chromatographic conditions were SuperdexTM peptide column, 0.01 mol*L-1 phosphate buffer solution as mobile phase, and flow rate of 1 mL·min-1. Five hundred microliters of lincomycin hydrochloride solution (3 g of lincomycin hydrochloride dissolved in 10 mL of mobile phase) was injected into the chromatograph and the eluted solution was collected between 6 min and 14.5 min (protein eluted from column within this period), and the residual content of total protein in the eluted solution was assayed using Bradford assay method. Results The average recovery was more than 90% for bovine serum albumin, the calibration equation for the range of 0-12 μg·mL-1 of protein was y=-0.002 4x2+0.064 2x+0.002 9, r2=0.999 9, RSD=0.1%-0.9%, and the LOD and LOQ were 3 and 10 ng·mL-1 of protein, respectively. Conclusion The novel method for determining the residual protein in ferment antibio-tics is simple, rapid, and precise.展开更多
Aim To establish a reversed-phase liquid chromatographic (LC) method forsimultaneous determination of tetramethylpyrazine (TMP) and aspirin in a new compound formulation.Methods Chromatographic separation of the two d...Aim To establish a reversed-phase liquid chromatographic (LC) method forsimultaneous determination of tetramethylpyrazine (TMP) and aspirin in a new compound formulation.Methods Chromatographic separation of the two drugs was achieved on a Diamonsil C_(18) column, usinga binary mixture of methanol-1.5% acetic acid (35:65, V/V, pH = 3.1) as mobile phase at a flow rateof 1.0 mL·min^(-1). Results Separation was completed in less than 12 min. Benzoic acid was used asthe internal standard. Recoveries at levels corresponding to 80 % to 120 % of the label claim ofthe formulation ranged from 99.6 to 100.3 % for aspirin and from 99.9 to 101.3% for TMP. The linearrange was 12.6 - 150.9 μg·mL^(-1)(r= 0.9997, n = 5) for aspirin and 25.0- 300.0 μg·mL^(-1) (r =0.9999, n = 5) for TMP. Conclusion The method developed can be used for the simultaneousdetermination of TMP and aspirin in pharmaceutical preparations.展开更多
The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples...The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples of five different geographic origins: Eastern China.Central China.South-western China,North-western China and North-eastern China.Principal component analysis and SIMCA are applied to effectively classifying the samples according to the origin of the plants.The chemical information contained in the high resolution gas chromatographic data is sufficient to characterize the geographic origin of sam- pies.展开更多
[Objective] The aim was to analyze sugar components in fermented rice wine by ion chromatography. [Method] The optimal condition for chromatography system of sugar analysis was selected by measuring sugars in fermente...[Objective] The aim was to analyze sugar components in fermented rice wine by ion chromatography. [Method] The optimal condition for chromatography system of sugar analysis was selected by measuring sugars in fermented rice wine with ion chromatography and pulsed amperometric detection. [Result] The optimal measurement conditions were as follows: Leacheate (Leachate), consisting of NaOH and CH3COONa, was eluted by gradient concentrations, with column temperature at 35 ℃ and flow rate at 0.4 ml/min. In the condition, sugars in rice wine were ana- lyzed and the results showed that the method is featured by low detection limit, good repetition and high recovery rate. [Conclusion] The research establishes and determines the approaches and optimum conditions for sugar analysis in rice wine by ion chromatography and pulsed amperometric detection, providing references for advancement of research on quality improvement of fermented rice wine.展开更多
The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi...The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy.展开更多
A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with...A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with N-hexane,and then they were cleanup with column that filled with florisil,subsequently separated by Capillary Column Gas Chromatography,and the electron capture detector (ECD) was used for detection.The detection limit of this method was 0.005 mg/kg (S/N=3),and this method was rapid,sensitive and accurate,and was applied in the determination of dichlofluanid residue in soybean.展开更多
A new capillary gas chromatography stationary phase, monokis (2,6 di O benzyl 3 O propyl (3’)) hexakis(2,6 di O benzyl 3 O methyl) β CD bonded polysiloxane, was synthesized. It ex...A new capillary gas chromatography stationary phase, monokis (2,6 di O benzyl 3 O propyl (3’)) hexakis(2,6 di O benzyl 3 O methyl) β CD bonded polysiloxane, was synthesized. It exhibited separation abilities to disubstituted benzene isomers and some chiral solutes. It was also found that the polarity of CD derivatives can be lowered both by chemically bonding it to polysiloxane and by diluting it in polysiloxane. The separation abilities of the polysiloxane anchored CDs (SP CD) are higher than that of the unbonded CDs (S CD) and the diluted S CD at lower column temperature. Hydrosilylation reaction is one of the best methods to lower the operating temperature of CDs.展开更多
A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas...A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs.展开更多
The cross-linking of crown ether-SE-54 in fused-silica capillary columns were initiated by dicumyl peroxide(DCUP),azo-bis-isobutyronitrile (AIBN)and ozone(O_3).Parameters of evaluation such as polarity,selectivity, ph...The cross-linking of crown ether-SE-54 in fused-silica capillary columns were initiated by dicumyl peroxide(DCUP),azo-bis-isobutyronitrile (AIBN)and ozone(O_3).Parameters of evaluation such as polarity,selectivity, phase transition temperature and thermal stability were studied and compared with those of poly(crown ether)stationary phase.展开更多
A method was developed for determination of chlorine and bromine in plant materials by ion chromatography using temperature programing-semi molten for sample preparation. Values of detection limits of the method found...A method was developed for determination of chlorine and bromine in plant materials by ion chromatography using temperature programing-semi molten for sample preparation. Values of detection limits of the method found were 1.0×10^-5 for CI and 1.3×10^-6 for Br. The measuring range of the method found were 0.3-20.0 mg/L for CI and 4,0-120,0 μg/L for Br. The results obtained agreed quite well with those reference values.展开更多
基金Supported by The Fourth Batch of High-end Talent Project in Hebei Province.
文摘[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.
基金supported by the National Natural Science Foundation of China(22078281)。
文摘The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar compounds.This study introduces an optimized twin-column recycling chromatography method for the efficient and simultaneous purification of these elusive constituents.By introducing water at a small flowing rate between the twin columns,a step solvent gradient is created,by which the leading edge of concentration band would migrate at a slower rate than the trailing edge as it flowing from the upstream to downstream column.Hence,the band broadening is counterbalanced,resulting in an enrichment effect for those minor components in separation process.Herein,two target substances,which showed similar peak position in high performance liquid chromatography(HPLC)and did not exceed 1.8%in crude paclitaxel were selected as target compounds for separation.By using the twin-column recycling chromatography with a step solvent gradient,a successful purification was achieved in getting the two with the purity almost 100%.We suggest this method is suitable for the separation of most components in natural produces,which shows higher precision and recovery rate compared with the common lab-operated separation ways for natural products(thin-layer chromatography and prep-HPLC).
文摘In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.
文摘Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant properties of Gymnema sylvestre extracts.Ethanolic reflux extraction followed by column chromatography was employed to isolate phenolic compounds.The total phenolic and flavonoid contents were quantified using the Folin–Ciocalteu and aluminum chloride colorimetric methods,respectively.Antioxidant activities were assessed by DPPH,ABTS scavenging assays and the ferric reducing antioxidant power(FRAP)assay.High-Performance Liquid Chromatography(HPLC)with a C18 column and Thermo TSQ Quantum Access Max(LC-MS)were used to determine the levels of gymnemic acid and identify other potential phenolic compounds.The analysis revealed significant antioxidant activities in the fractions.Fraction A showed the highest DPPH and ABTS scavenging activities,and Fraction C demonstrated the highest ferric reducing power.LC-MS analysis identified several phenolic compounds,indicating that these are major contributors to the antioxidant efficacy of the extract.This study provides a detailed phenolic profile and confirms the strong antioxidant potential of Gymnema sylvestre leaf extract,supporting its therapeutic use and further investigation.
基金financed by the project supported by the National Natural Science Foundation of China(22078266,21908180,22178289,22278338)the Key Research and Development Program of Shaanxi(2020ZDLGY11-02,2021GY-136)the Special Fund for High-level Scholars of China(XJ21B10)。
文摘The low temperature coal tar(CT)is taken as the raw material,and the extraction and column chromatography are used for detailed and accurate characterization in this paper.The n-heptane soluble fraction(CT-HS)and insoluble fraction(CT-HI)were obtained by n-heptane Soxhlet extraction.The extraction rate of CT-HS reached 92.79%(mass),which indicated that there are few heavy compounds in it.Further,different solvents(methylbenzene,benzene,ethyl acetate,methylbenzene-ethanol)were used to elute CT-HS by chromatographic column to obtain five fractions(saturates,aromatics,heteroatoms,phenolics and resins,named CT-SA,CT-AR,CT-HE,CT-PH,CT-RE,respectively).The yields of CTSA,CT-AR,CT-HE,CT-PH,CT-RE are 42.12%,10.43%,2.19%,9.50%and 6.63%(mass),respectively.Gas chromatography-mass spectrometry analysis of eluting components show that alkanes are the main components in CT,followed by polycyclic aromatics,and the corresponding fractions are CT-SA and CT-AR,respectively.The relative content of aliphatics in CT-SA is 76.93%,and the relative content of aromatics in CT-AR is 75.05%.This separation technology effectively separates and enriches different components in CT,and the activation energy required for the pyrolysis process of a single eluting fraction is lower than that of CT,which is expected to provide an important reference for the separation,analysis and conversion of complex oil products such as coal-oil co-processing products,coal tar and other complex heavy carbon oil products.
基金the Natural Science Foundation of Jiangxi Province,China(No.20202BABL203004)the Opening Project of the State Key Laboratory of Nuclear Resources and Environment(East China University of Technology)(No.2022NRE23)the Opening Project of Jiangxi Province Key Laboratory of Polymer Micro/Nano Manufacturing and Devices(No.PMND202101).
文摘The novel pulsed liquid chromatography radionuclide separation method presented here provides a new and promising strategy for the extraction of uranium from seawater.In this study,a new chromatographic separation method was proposed,and a pulsed nuclide automated separation device was developed,alongside a new chromatographic column.The length of this chromatographic column was 10 m,with an internal warp of 3 mm and a packing size of 1 mm,while the total separation units of the column reached 12,250.The most favorable conditions for the separation of nuclides were then obtained through optimizing the separation conditions of the device:Sample pH in the column=2,sample injection flow rate=5.698 mL/min,chromatographic column heating temperature=60℃.Separation experiments were also carried out for uranium,europium,and sodium ions in mixed solutions;uranium and sodium ions in water samples from the Ganjiang River;and uranium,sodium,and magnesium ions from seawater samples.The separation factors between the different nuclei were then calculated based on the experimental data,and a formula for the separation level was derived.The experimental results showed that the separation factor in the mixed solution of uranium and europium(1:1)was 1.088,while achieving the initial separation of uranium and europium theoretically required a 47-stage separation.Considering the separation factor of 1.50for the uranium and sodium ions in water samples from the Ganjiang River,achieving the initial separation of uranium and sodium ions would have theoretically required at least a 21-stage separation.Furthermore,for the seawater sample separation experiments,the separation factor of uranium and sodium ions was 1.2885;therefore,more than 28 stages of sample separation would be required to achieve uranium extraction from seawater.The novel pulsed liquid chromatography method proposed in this study was innovative in terms of uranium separation and enrichment,while expanding the possibilities of extracting uranium from seawater through chromatography.
基金Supported by Key R&D Plan of Guangxi Zhuang Autonomous Region(Guike AB20297010).
文摘[Objectives] To establish the process flow of preparation of Wufang Babu Poultice and the identification method of thin layer chromatography (TLC). [Methods] For the forming process of Wufang Babu Poultice, the preparation method of mixed pharmaceutical powder with suitable pharmaceutical excipients was adopted. Qualitative identification of medicinal materials in Wufang Babu Poultice (Strychni Semen, Rhei Radix Et Rhizoma, Dipsaci Radix, and Angelicae Sinensis Radix) was carried out by TLC. [Results] Mixed pharmaceutical powder mixed with glycerol, gelatin and other pharmaceutical excipients can be prepared for forming. The test solution chromatography of each medicinal material (Strychni Semen, Rhei Radix et Rhizoma, Dipsaci Radix, Angelicae Sinensis Radix) showed pigment spots of the same color at the same position as its corresponding control medicinal materials and reference chromatography, and the display was clear. [Conclusions] The preparation process is simple and feasible, and can be used as the forming process of Wufang Babu Poultice. The TLC determination method is simple to operate, has good specificity, and has no effect on negative results, and can be used for identification of Wufang Babu Poultice.
文摘A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with fluconazole as an Internal Standard and directed to protein precipitation and drug extraction. An aliquot of 1 μl was injected into the chromatographic system and separated by the Acquity BEH C18 column at a flow rate of 0.30 ml/min in a gradient mobile phase consisting of acetonitrile, Ultrapure water (UPW), methanol and formic acid. Voriconazole was detected by a Triple Quadrupole Detector (TQD) operating on Multiple Reaction Monitoring (MRM) and a positive ion mode Electrospray ionization (ESI) Q1 mass: 350.1 m/z, Q3 mass: 281.1 m/z. Method linearity of the calibration curve (0.10 - 8.00 μg/ml) indicated a correlation coefficient r ≥ 0.99. The intra and inter-assay accuracy was within 85% - 115% and the intra and inter-assay precision was ≤5.76%. Voriconazole recovery percentage was between 97.69 - 119.62%. The method was successively applied in routine voriconazole TDM.
文摘The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R2> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection.
文摘Applications of pyrolysis-gas chromatography and pyrolysis capillary gas chromatography in explosive and propellant analysis are reviewed, including the identification of explosives and propel- lants, the investigation of the thermal decomposition of nitrocellulose (NC), cyclotetramethylene tetranitramine (HMX)and cyclotrimethylene trinitramine (RDX), and the study of the wear- reducing mechanism of polyurethane additive in propellant gain.
文摘Aim A novel method has been developed for evaluation of the levels of total residual protein in antibiotics produced by fermentation using gel filtration chromatography (GFC) combined with Bradford assay based on determination of residual protein in lincomycin hydrochloride. Methods The chromatographic conditions were SuperdexTM peptide column, 0.01 mol*L-1 phosphate buffer solution as mobile phase, and flow rate of 1 mL·min-1. Five hundred microliters of lincomycin hydrochloride solution (3 g of lincomycin hydrochloride dissolved in 10 mL of mobile phase) was injected into the chromatograph and the eluted solution was collected between 6 min and 14.5 min (protein eluted from column within this period), and the residual content of total protein in the eluted solution was assayed using Bradford assay method. Results The average recovery was more than 90% for bovine serum albumin, the calibration equation for the range of 0-12 μg·mL-1 of protein was y=-0.002 4x2+0.064 2x+0.002 9, r2=0.999 9, RSD=0.1%-0.9%, and the LOD and LOQ were 3 and 10 ng·mL-1 of protein, respectively. Conclusion The novel method for determining the residual protein in ferment antibio-tics is simple, rapid, and precise.
文摘Aim To establish a reversed-phase liquid chromatographic (LC) method forsimultaneous determination of tetramethylpyrazine (TMP) and aspirin in a new compound formulation.Methods Chromatographic separation of the two drugs was achieved on a Diamonsil C_(18) column, usinga binary mixture of methanol-1.5% acetic acid (35:65, V/V, pH = 3.1) as mobile phase at a flow rateof 1.0 mL·min^(-1). Results Separation was completed in less than 12 min. Benzoic acid was used asthe internal standard. Recoveries at levels corresponding to 80 % to 120 % of the label claim ofthe formulation ranged from 99.6 to 100.3 % for aspirin and from 99.9 to 101.3% for TMP. The linearrange was 12.6 - 150.9 μg·mL^(-1)(r= 0.9997, n = 5) for aspirin and 25.0- 300.0 μg·mL^(-1) (r =0.9999, n = 5) for TMP. Conclusion The method developed can be used for the simultaneousdetermination of TMP and aspirin in pharmaceutical preparations.
文摘The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples of five different geographic origins: Eastern China.Central China.South-western China,North-western China and North-eastern China.Principal component analysis and SIMCA are applied to effectively classifying the samples according to the origin of the plants.The chemical information contained in the high resolution gas chromatographic data is sufficient to characterize the geographic origin of sam- pies.
基金Supported by Changsha Key Project in Hunan Province(K1005007-21)~~
文摘[Objective] The aim was to analyze sugar components in fermented rice wine by ion chromatography. [Method] The optimal condition for chromatography system of sugar analysis was selected by measuring sugars in fermented rice wine with ion chromatography and pulsed amperometric detection. [Result] The optimal measurement conditions were as follows: Leacheate (Leachate), consisting of NaOH and CH3COONa, was eluted by gradient concentrations, with column temperature at 35 ℃ and flow rate at 0.4 ml/min. In the condition, sugars in rice wine were ana- lyzed and the results showed that the method is featured by low detection limit, good repetition and high recovery rate. [Conclusion] The research establishes and determines the approaches and optimum conditions for sugar analysis in rice wine by ion chromatography and pulsed amperometric detection, providing references for advancement of research on quality improvement of fermented rice wine.
文摘The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy.
文摘A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with N-hexane,and then they were cleanup with column that filled with florisil,subsequently separated by Capillary Column Gas Chromatography,and the electron capture detector (ECD) was used for detection.The detection limit of this method was 0.005 mg/kg (S/N=3),and this method was rapid,sensitive and accurate,and was applied in the determination of dichlofluanid residue in soybean.
文摘A new capillary gas chromatography stationary phase, monokis (2,6 di O benzyl 3 O propyl (3’)) hexakis(2,6 di O benzyl 3 O methyl) β CD bonded polysiloxane, was synthesized. It exhibited separation abilities to disubstituted benzene isomers and some chiral solutes. It was also found that the polarity of CD derivatives can be lowered both by chemically bonding it to polysiloxane and by diluting it in polysiloxane. The separation abilities of the polysiloxane anchored CDs (SP CD) are higher than that of the unbonded CDs (S CD) and the diluted S CD at lower column temperature. Hydrosilylation reaction is one of the best methods to lower the operating temperature of CDs.
基金The National Basic Research Program of China(973Program)(No.2012CB933302)the National Instrumental Research Program(No.2014YQ06077303)+1 种基金the National Natural Science Foundation of China(No.81172720,21307086)Suzhou Science and Technology Department Foundation(No.ZXG201441)
文摘A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs.
文摘The cross-linking of crown ether-SE-54 in fused-silica capillary columns were initiated by dicumyl peroxide(DCUP),azo-bis-isobutyronitrile (AIBN)and ozone(O_3).Parameters of evaluation such as polarity,selectivity, phase transition temperature and thermal stability were studied and compared with those of poly(crown ether)stationary phase.
文摘A method was developed for determination of chlorine and bromine in plant materials by ion chromatography using temperature programing-semi molten for sample preparation. Values of detection limits of the method found were 1.0×10^-5 for CI and 1.3×10^-6 for Br. The measuring range of the method found were 0.3-20.0 mg/L for CI and 4,0-120,0 μg/L for Br. The results obtained agreed quite well with those reference values.