期刊文献+
共找到66篇文章
< 1 2 4 >
每页显示 20 50 100
Determination of velocity correction factors for real-time air velocity monitoring in underground mines 被引量:15
1
作者 Lihong Zhou Liming Yuan +1 位作者 Rick Thomas Anthony Iannacchione 《International Journal of Coal Science & Technology》 EI 2017年第4期322-332,共11页
When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air vel... When there are installations of air velocity sensors in the mining industry for real-time airflow monitoring, a problem exists with how the monitored air velocity at a fixed location corresponds to the average air velocity, which is used to determine the volume flow rate of air in an entry with the cross-sectional area. Correction factors have been practically employed to convert a measured centerline air velocity to the average air velocity. However, studies on the recommended correction factors of the sensor-measured air velocity to the average air velocity at cross sections are still lacking. A comprehensive airflow measurement was made at the Safety Research Coal Mine, Bruceton, PA, using three measuring methods including single-point reading, moving traverse, and fixed-point traverse. The air velocity distribution at each measuring station was analyzed using an air velocity contour map generated with Surfer~. The correction factors at each measuring station for both the centerline and the sensor location were calculated and are discussed. 展开更多
关键词 Underground mine Airflow measurement - correction factor
下载PDF
Estimation of structure crack propagation based on multiple factors correction
2
作者 朱林 贾民平 +1 位作者 姜长城 张菀 《Journal of Southeast University(English Edition)》 EI CAS 2017年第1期39-45,共7页
By deriving the stress concentration factor of theestimation approach for residual fatigue life’ an estimationapproach for structure crack propagation based on multiplefactors correction is proposed. Then’ the quant... By deriving the stress concentration factor of theestimation approach for residual fatigue life’ an estimationapproach for structure crack propagation based on multiplefactors correction is proposed. Then’ the quantitativeexpression among the structure factor’ stress ratio’ loadingtype’ the manufacture processing factor and the crackpropagation is achieved. The proposed approach iimplemented in a case study for an instance structure’ and theinfluences of correction factors on the crack propagation areanalyzed. Meanwhile’ the probabilistic method based onWeibull distribution probability density function is selected toevaluate the precision of the corrected estimation approach’and the probability density of results is calculated by theprobability density function. It is shown that the resultsestimated by the corrected approach is more precise than thoseestimated by the fracture mechanics, and they are closer to thetest data. 展开更多
关键词 estimation study crack propagation multiple factor correction probability density function
下载PDF
Correction Factors of the Approximate Theories for Axisymmetric Modes of Longitudinal Waves in Circular Rods
3
作者 Longtao Xie Chunlei Bian Ji Wang 《Acta Mechanica Solida Sinica》 SCIE EI CSCD 2022年第5期824-833,共10页
The longitudinal waves guided by rods are widely used in broad engineering fields.Approximate theories are required to improve the understanding of the longitudinal wave propagation in finite rods in particular.The co... The longitudinal waves guided by rods are widely used in broad engineering fields.Approximate theories are required to improve the understanding of the longitudinal wave propagation in finite rods in particular.The correction factors are commonly used in the vibration analyses of beams and plates,but are seldom adopted to the longitudinal wave propagation in rods in a similar manner.In this paper,the longitudinal and radial displacements in axisymmetric problems of circular rods are expanded in infinite power series of the radial coordinate.By using Hamilton’s principle,an infinite one-dimensional system of equations of motion is established.The high-order components of stress and strain,and their relations are introduced to obtain the infinite one-dimensional system for the axisymmetric wave propagation in elastic rods.A proper truncation of the infinite equations leads to an approximate theory of a specific order.To improve the truncated equations,some high-order components of strain are multiplied by the correction factors.The correction factors for the first-to fourth-order approximations are systematically determined to ensure that the cutoff frequencies are the same as the exact values calculated by the Pochhmammer–Chree equation.The frequency spectra,via the well-known Pochhmammer–Chree equation and the approximate theories of order one to four,are presented for comparison in a region where the longitudinal wave is not attenuating and the wavelength in the axial direction is longer than the diameter of the rod.Compared to the approximate theories without correction factors,the approximate theories with correction factors show some advantages in accuracy when the branches are high. 展开更多
关键词 Symmetric wave Approximate theory of rods correction factor Frequency
原文传递
New scale factor correction scheme for CORDIC algorithm 被引量:1
4
作者 戴志生 张萌 +1 位作者 高星 汤佳健 《Journal of Southeast University(English Edition)》 EI CAS 2009年第3期313-315,共3页
To overcome the drawbacks such as irregular circuit construction and low system throughput that exist in conventional methods, a new factor correction scheme for coordinate rotation digital computer( CORDIC) algorit... To overcome the drawbacks such as irregular circuit construction and low system throughput that exist in conventional methods, a new factor correction scheme for coordinate rotation digital computer( CORDIC) algorithm is proposed. Based on the relationship between the iteration formulae, a new iteration formula is introduced, which leads the correction operation to be several simple shifting and adding operations. As one key part, the effects caused by rounding error are analyzed mathematically and it is concluded that the effects can be degraded by an appropriate selection of coefficients in the iteration formula. The model is then set up in Matlab and coded in Verilog HDL language. The proposed algorithm is also synthesized and verified in field-programmable gate array (FPGA). The results show that this new scheme requires only one additional clock cycle and there is no change in the elementary iteration for the same precision compared with the conventional algorithm. In addition, the circuit realization is regular and the change in system throughput is very minimal. 展开更多
关键词 coordinate rotation digital computer (CORDIC) algorithm scale factor correction field-programmable gate array (FPGA)
下载PDF
Period-doubling bifurcation in two-stage power factor correction converters using the method of incremental harmonic balance and Floquet theory 被引量:4
5
作者 Wang Fa-Qiang Zhang Hao Ma Xi-Kui 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第2期153-162,共10页
In this paper, period-doubling bifurcation in a two-stage power factor correction converter is analyzed by using the method of incremental harmonic balance (IHB) and Floquet theory. A two-stage power factor correcti... In this paper, period-doubling bifurcation in a two-stage power factor correction converter is analyzed by using the method of incremental harmonic balance (IHB) and Floquet theory. A two-stage power factor correction converter typically employs a cascade configuration of a pre-regulator boost power factor correction converter with average current mode control to achieve a near unity power factor and a tightly regulated post-regulator DC-DC Buck converter with voltage feedback control to regulate the output voltage. Based on the assumption that the tightly regulated postregulator DC-DC Buck converter is represented as a constant power sink and some other assumptions, the simplified model of the two-stage power factor correction converter is derived and its approximate periodic solution is calculated by the method of IHB. And then, the stability of the system is investigated by using Floquet theory and the stable boundaries are presented on the selected parameter spaces. Finally, some experimental results are given to confirm the effectiveness of the theoretical analysis. 展开更多
关键词 two-stage power factor correction converter incremental harmonic balance Floquet theory period-doubling bifurcation
下载PDF
Spectral Dependence on the Correction Factor of Erythemal UV for Cloud, Aerosol, Total Ozone, and Surface Properties: A Modeling Study 被引量:2
6
作者 Sang Seo PARK Yeonjin JUNG Yun Gon LEE 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2016年第7期865-874,共10页
Radiative transfer modal simulations were used to investigate the erythemal ultraviolet (EUV) correction factors by separating the UV-A and UV-B spectral ranges. The correction factor was defined as the ratio of EUV... Radiative transfer modal simulations were used to investigate the erythemal ultraviolet (EUV) correction factors by separating the UV-A and UV-B spectral ranges. The correction factor was defined as the ratio of EUV caused by changing the amounts and characteristics of the extinction and scattering materials. The EUV correction factors (CFEUV) for UV-A [CFEUV(A)] and UV-B [CFEUV(B)] were affected by changes in the total ozone, optical depths of aerosol and cloud, and the solar zenith angle. The differences between CFEUV(A) and CFEUV(B) were also estimated as a function of solar zenith angle, the optical depths of aerosol and cloud, and total ozone. The differences between CFEUV(A) and CFEUV(B) ranged from -5.0% to 25.0% for aerosols, and from -9.5% to 2.0% for clouds in all simulations for different solar zenith angles and optical depths of aerosol and cloud. The rate of decline of CFEUV per unit optical depth between UV-A and UV-B differed by up to 20% for the same aerosol and cloud conditions. For total ozone, the variation in CFEUV(A) was negligible compared with that in CFEUV(B) because of the effective spectral range of the ozone absorption band. In addition, the sensitivity of the CFEUVs due to changes in surface conditions (i.e., surface albedo and surface altitude) was also estimated by using the model in this study. For changes in surface albedo, the sensitivity of the CFEUVs was 2.9%-4.1% per 0.1 albedo change, depending on the amount of aerosols or clouds. For changes in surface altitude, the sensitivity of CFEUV(B) was twice that of CFEUV(A), because the Rayleigh optical depth increased significantly at shorter wavelengths. 展开更多
关键词 Erythemal UV correction factor UV-A UV-B
下载PDF
Revisiting the Bjerrum's correction factor:Use of the liquidity index for assessing the effect of soil plasticity on undrained shear strength 被引量:2
7
作者 Kamil Kayabali Ozgur Akturk +2 位作者 Mustafa Fener Orhan Dikmen Furkan Hamza Harputlugil 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2015年第6期716-721,共6页
The undrained shear strength (su) of fine-grained soils that can be measured in situ and in laboratory isone of the key geotechnical parameters. The unconfined compression test (UCT) is widely used in laboratoryto... The undrained shear strength (su) of fine-grained soils that can be measured in situ and in laboratory isone of the key geotechnical parameters. The unconfined compression test (UCT) is widely used in laboratoryto measure this parameter due to its simplicity; however, it is severely affected by sampledisturbance. The vane shear test (VST) technique that is less sensitive to sample disturbance involves acorrection factor against the soil plasticity, commonly known as the Bjerrum's correction factor, m. Thisstudy aims to reevaluate the Bjerrum's correction factor in consideration of a different approach and arelatively new method of testing. Atterberg limits test, miniature VST, and reverse extrusion test (RET)were conducted on 120 remolded samples. The effect of soil plasticity on undrained shear strength wasexamined using the liquidity index instead of Bjerrum's correction factor. In comparison with the resultobatined using the Bjerrum's correction factor, the undrained shear strength was better representedwhen su values were correlated with the liquidity index. The results were validated by the RET, whichwas proven to take into account soil plasticity with a reliable degree of accuracy. This study also showsthat the RET has strong promise as a new tool for testing undrained shear strength of fine-grained soils. 展开更多
关键词 Soil plasticity Undrained shear strength Bjerrum's correction factor Vane shear test(VST) Reverse extrusion test(RET)
下载PDF
A new high-performance AC/DC power factor correction switching converter based on one-cycle control technology and active floating-charge technology 被引量:3
8
作者 高潮 《Journal of Chongqing University》 CAS 2008年第2期119-124,共6页
A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The t... A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The topology of a single-phase CCM and DCM Boost-PFC switching converter was also analyzed.Its operating prniciples and control methods were expounded.Based on these,a new type of AC/DC switching converter circuits for PFC combined with one-cycle control technology was presented herein.The proposed AC/DC switching converter significantly helps improve the converter efficiency and its power factor value. 展开更多
关键词 AC/DC converter floating charge technology active power factor correction switching converter
下载PDF
A New Thermodynamic Calculation Method for Binary Alloys Part II:Exploring the Correction Factor Function 被引量:1
9
作者 XingqiuCHEN P.Rogl 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2002年第4期328-331,共4页
A new method of revising activity values has been derived based on the so called correction factor function for binary alloys with a large difference between two components. The correction factor is a function of phys... A new method of revising activity values has been derived based on the so called correction factor function for binary alloys with a large difference between two components. The correction factor is a function of physical properties formed by the difference of two components. Its absolute value increases with the enhancement of the difference in the character of components. It can be either positive or negative and the rules for selecting the sign of correction factor have been analyzed. Results are in good agreement with the experimental values. 展开更多
关键词 correction factor function THERMODYNAMICS Binary alloys
下载PDF
Performance Evaluation of a Permanent Magnet Electric-Drive- Reconfigured Onboard Charger with Active Power Factor Correction 被引量:3
10
作者 Feng Yu Zhihao Zhu +1 位作者 Jingfeng Mao Juping Gu 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第1期72-80,共9页
This paper presents a comprehensive charging operation for an electric-drive-reconfigured onboard charger(EDROC)with active power factor correction(APFC).The charging topology exclusively utilizes the three-phase perm... This paper presents a comprehensive charging operation for an electric-drive-reconfigured onboard charger(EDROC)with active power factor correction(APFC).The charging topology exclusively utilizes the three-phase permanent magnet synchronous motor(PMSM)propulsion system as a three-channel boost-type converter in which only a contactor and a small diode bridge are added.First,the operation scenario of the EDROC is introduced.Second,the relationship between electromagnetic torque and rotor position is investigated.Third,the current ripple cancellation of the EDROC is discussed in detail.Moreover,to implement the single-phase APFC along with charging voltage/current regulation of propulsion battery,control strategies including current balancing and synchronous/interleaving PWM strategies are incorporated.Finally,200W proof-of-concept prototype-based tests are conducted under different operation scenarios. 展开更多
关键词 Active power factor correction current balancing electric-drive-reconfigured electromagnetic torque INTERLEAVING onboard charger.
下载PDF
Single-stage active clamp power factor correction AC/DC converter
11
作者 张继红 王伟哲 +1 位作者 吴长顺 吕志伟 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2007年第6期833-836,共4页
A simple single-stage AC/DC converter circuit with active clamp is presented. The operation theory and state are analyzed. The experimental results show that the voltage across main switch can be clamped to a certain ... A simple single-stage AC/DC converter circuit with active clamp is presented. The operation theory and state are analyzed. The experimental results show that the voltage across main switch can be clamped to a certain value,and zero voltage switching (ZVS) can be achieved. The voltage stress and switching loss are both decreased. In range of the whole load,power factors can be always more than 97%,and the highest efficiency can reach 88%. 展开更多
关键词 single stage AC/DC converter active clamp power factor correction
下载PDF
Correction of Factitious Hyperkalemia in Hemolysed Specimens from Adult Emergency Department Using the Beckman Coulter Unicell DxC 880i Analyzer Derived Factor
12
作者 C. Domingues R. Carneiro M. Dias 《Journal of Pharmacy and Pharmacology》 2017年第12期902-906,共5页
Hemolysis in ED (emergency department) patients is common due to difficult blood draws. Values of serum potassium (K+) become falsely elevated secondary to release of intracellular contents. Objective: The aim o... Hemolysis in ED (emergency department) patients is common due to difficult blood draws. Values of serum potassium (K+) become falsely elevated secondary to release of intracellular contents. Objective: The aim of the study was to establish a correction factor for factitious elevated K+ in samples for de adult ED. Methods: We used samples from 125 adult ED patients, in which the 2nd sample was drawn due to hemolysis of the first tube. Results: Firstly, we derived a correction factor expressing an increase in potassium concentration in 0.21 mmol/L (95% confidence interval, 0.17-0.24 mmol/L with p 〈 0.01) for each hemolysis index increment. Conclusions: A reliable correction factor for factitious hyperkalemia in a clinical relevant range exists. 展开更多
关键词 Potassium HEMOLYSIS correction factor.
下载PDF
New DCM Operated Single Phase Bridgeless Cuk Derived Converters for Power Factor Correction
13
作者 P. M. Dhanasekaran Parasunath Veena Rajaiah Jeyabharath 《Circuits and Systems》 2016年第9期2176-2188,共13页
This paper presents a power factor corrected (PFC) new bridgeless (BL) Cuk Topologies for low power applications. A BL configuration of Cuk converter is proposed which eliminates the usage of diode bridge rectifier at... This paper presents a power factor corrected (PFC) new bridgeless (BL) Cuk Topologies for low power applications. A BL configuration of Cuk converter is proposed which eliminates the usage of diode bridge rectifier at the front end of the PFC converter, thus reducing the switching and conduction losses coupled with it. This new BL Cuk converter has two semiconductors switches. The current flow during each switching cycle interval of the converter reduces the conduction losses compared to the conventional Cuk PFC converter. It also reduces the input current ripple and Electromagnetic Interference (EMI). The inrush current during the starting period is limited and the input, output currents of the converter are continuous with minimum current ripple. Hence it is preferred mostly compared to other PFC circuits. The proposed topology works in the Discontinuous Conduction Mode (DCM) with simple control circuitry to achieve almost a unity power factor with less distortion in the input AC current. The switching of the power switches is done under zero current. The proposed PFC topologies are theoretically investigated and performance comparisons are made with the conventional rectifiers. The proposed PFC converter is simulated in MATLAB/SIMULINK with Fuzzy Logic Controller (FLC) and results are demonstrated to evaluate the effectiveness of the controller. 展开更多
关键词 Bridgeless (BL) Cuk Converter Topology Power Factor correction (PFC) Total Harmonic Distortion (THD) Fuzzy Logic Controller (FLC)
下载PDF
Research on the distribution characteristics of explosive shock waves at different altitudes 被引量:6
14
作者 Liang-quan Wang De-ren Kong 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2023年第6期340-348,共9页
There are great differences in the distribution characteristics of shock waves produced by ammunition explosions at different altitudes.At present,there are many studies on plain explosion shock waves,but there are fe... There are great differences in the distribution characteristics of shock waves produced by ammunition explosions at different altitudes.At present,there are many studies on plain explosion shock waves,but there are few studies on the distribution characteristics of plateau explosion shock waves,and there is still a lack of complete analysis and evaluation methods.This paper compares and analyzes shock wave overpressure data at different altitudes,obtains the attenuation effect of different altitudes on the shock wave propagation process and proposes a calculation formula for shock wave overpressure considering the effect of altitude.The data analysis results show that at the same TNT equivalent and the same distance from the measuring point,the shock wave overpressure at high altitude is lower than that at low altitude.With the increase in the explosion center distance of the measuring point,the peak attenuation rate of the shock wave overpressure at high altitudes is smaller than that at low altitudes,and the peak attenuation rate of the shock wave overpressure at high altitudes gradually intensifies with increasing proportional distance.The average error between the shock wave overpressure and measured shock wave overpressure in a high-altitude environment obtained by using the above calculation formula is 11.1389%.Therefore,this method can effectively predict explosion shock wave overpressure in plateau environments and provides an effective calculation method for practical engineering tests. 展开更多
关键词 Shock wave overpressure calculation Pressure attenuation law Altitude correction factor Engineering numerical model
下载PDF
Simultaneous Determination of Five Components in Operculina turpethum
15
作者 Chaomin ZHONG Xin YANG +1 位作者 Nianzhi XU Bing LI 《Agricultural Biotechnology》 CAS 2023年第1期78-83,共6页
[Objectives]This study was conducted to establish a method for the simultaneous determination of caffeic acid, rutin, ononin, luteolin, and apigenin in Operculina turpethum(L.) S. Manso. [Methods]With ononin from O. t... [Objectives]This study was conducted to establish a method for the simultaneous determination of caffeic acid, rutin, ononin, luteolin, and apigenin in Operculina turpethum(L.) S. Manso. [Methods]With ononin from O. turpethum as the internal reference, the five components were separated by HPLC, and the contents of various components were calculated according to the relative correction factors of ononin with caffeic acid, rutin, luteolin, and apigenin. Meanwhile, the calculated results of quantitative analysis of multi-components by single marker(QAMS) were compared with the determined values of the external standard method. [Results] The linear relationship of the five components in their respective ranges was good(r=0.999 9). The average recovery was in the range of 97.48%-101.05%, and the RSD values were in the range of 1.04%-2.71%. The results obtained by QAMS were close to those obtained by the external standard method. [Conclusions] The method is accurate, stable and adaptable, and can be used for the determination of five flavonoids in O. turpethum. 展开更多
关键词 Operculina turpethum Relative correction factor Quantitative analysis of multi-components by single marker
下载PDF
Improving patient care and accuracy of given doses in radiation therapy using in vivo dosimetry verification
16
作者 Ahmed Shawky Shawata Tarek El Nimr Khaled M.Elshahat 《Oncology and Translational Medicine》 CAS 2015年第5期212-217,共6页
Objective This work aims to verify and improve the dose given for cancer patients in radiation therapy by using diodes to enhance patient in vivo dosimetry on a routine basis. Some characteristics of two available sem... Objective This work aims to verify and improve the dose given for cancer patients in radiation therapy by using diodes to enhance patient in vivo dosimetry on a routine basis. Some characteristics of two available semi-conductor diode dosimetry systems were evaluated. Methods The diodes had been calibrated to read the dose at Dmax below the surface. Correction factors of clinical relevance were quantified to convert the diode readings into patient dose. The diode was irradiated at various gantry angles (increments of 45~), various Field Sizes and various Source to Surface Distances (SSDs). Results The maximal response variation in the angular response with respect to an arbitrary angle of 0~ was 1.9%, and the minimum variation was 0.5%. The response of the diode with respect to various field siz- es showed the minimum and the maximum variations in the measured dose from the diode; the calculated doses were -1.6% (for 5 cm x 5 cm field size) and 6.6% (for 40 cm x 40 cm field size). The diode exhibited a significant perturbation in the response, which decreased with increasing SSD. No discrepancies larger than 5% were detected between the expected dose and the measured dose. Conclusion The results indicate that the diodes exhibit excellent linearity, dose reproducibility and minimal anisotropy; that they can be used with confidence for patient dose verification. Furthermore, diodes render real time verification of the dose delivered to patients. 展开更多
关键词 in vivo dosimetry diode dosimetry external beam radiation therapy UNCERTAINTY water slab phantom diode correction factors.
下载PDF
Experimental Investigation and Prediction Model of the Loads Exerted by Oblique Internal Solitary Waves on FPSO 被引量:3
17
作者 ZHANG Rui-rui WANG Hong-wei +3 位作者 CHEN Ke YOU Yun-xiang ZHANG Shu-guang XIONG Xiao-hu 《China Ocean Engineering》 SCIE EI CSCD 2022年第2期179-190,共12页
By using a 30-meter-long wave flume equipped with a double-plate wave maker,a series of depression ISWs were generated in a density stratified two-layer fluid and the forces exerted by oblique internal solitary waves(... By using a 30-meter-long wave flume equipped with a double-plate wave maker,a series of depression ISWs were generated in a density stratified two-layer fluid and the forces exerted by oblique internal solitary waves(ISWs)on fixed FPSO model had been measured.According to the laboratory experiments,a numerical flume taken the applicability of KdV,eKdV and MCC ISWs theories in consideration was adopted to study the force components.Based on the experimental data and the force composition,the simplified prediction model was established.It was shown that the horizontal and transversal loads consisted of two parts:the Froude−Krylov force that could be calculated by integrating the dynamic pressure induced by ISW along the FPSO wetted surface,as well as the viscous force that could be obtained by multiplying the friction coefficient Cfx(C_(fy)),correction factor K_(x)(K_(y))and the integration of particle tangential velocity along the FPSO wetted surface.The vertical load was mainly the vertical Froude−Krylov force.Based on the experimental results,a conclusion can be drawn that the friction coefficient Cf and correction factor K were regressed as a relationship of Reynolds number Re,Keulegan-Carpenter number KC,upper layer depth h1/h and ISW accident angleα.Moreover,the horizontal friction coefficient Cfx yielded the logarithmic function with Re,and transversal friction coefficient C_(fy)obeyed the exponent function with Re,while the correction factors K_(x)and K_(y)followed power function with KC.The force prediction was also performed based on the regression formulae and pressure integral.The predicted results agreed well with the experimental results.The maximum forces increase linearly with the ISWs amplitude.Besides,the upper layer thickness had an obvious influence on the extreme value of the horizontal and transversal forces. 展开更多
关键词 internal solitary wave(ISW) FPSO wave forces friction coefficient and correction factor accident angle
下载PDF
Thermal Fission Rate Calculated Numerically by Particles Multi-passing over SaddlePoint 被引量:3
18
作者 LIULing BAOJing-Dong 《Communications in Theoretical Physics》 SCIE CAS CSCD 2004年第2期273-278,共6页
Langevin simulation of the particles multi-passing over the saddle point is proposed to calculate thermal fission rate. Due to finite friction and the corresponding thermal fluctuation, a backstreaming exists in the p... Langevin simulation of the particles multi-passing over the saddle point is proposed to calculate thermal fission rate. Due to finite friction and the corresponding thermal fluctuation, a backstreaming exists in the process of the particle descent from the saddle to the scission. This leads to that the diffusion behind the saddle point has influence upon the stationary flow across the saddle point. A dynamical correction factor, as a ratio of the flows of multi- and first-overpassing the saddle point, is evaluated analytically. The results show that the fission rate calculated by the particles multi-passing over the saddle point is lower than the one calculated by the particle firstly passing over the saddle point, and the former approaches the results at the scission point. 展开更多
关键词 Langevin simulation backstreaming effect multi-passing oven saddle point dynamical correction factor
下载PDF
A novel arc welding inverter with unit power factor based on DSP control 被引量:3
19
作者 陈树君 曾华 +2 位作者 杜利 殷树言 陈永刚 《China Welding》 EI CAS 2006年第1期53-56,共4页
A novel inverter power source is developed characterized with constant output current and unit power factor input. Digital signal processor ( DSP ) is used to realize power factor correction and control of back-stag... A novel inverter power source is developed characterized with constant output current and unit power factor input. Digital signal processor ( DSP ) is used to realize power factor correction and control of back-stage inverter bridge of the arc welding inverter. The fore-stage adopts double closed loop proportion and integration (PI) rectifier technique and the back- stage adopts digital pulse width modulation ( PWM) technique. Simulated waves can be obtained in Matlab/Simulink and validated by experiments. Experiments of the prototype showed that the total harmonic distortion (THD) can be controlled within 10% and the power factor is approximate to 1. 展开更多
关键词 arc welding inverter power factor correction (PFC) digital signal processor (DSP) HARMONIC
下载PDF
Effect of Window Opening Percentage on the Air Flow Rate of Wind-Driven Natural Ventilation Rooms 被引量:2
20
作者 王勇 钟珂 +1 位作者 张宁波 亢燕铭 《Journal of Donghua University(English Edition)》 EI CAS 2012年第6期465-469,共5页
According to the investigations of window opening percentage (WOP) of Shanghai in 2011, the WOP varies significantly from season to season and thus affects the air flow rate of natural ventilation rooms. A three-dimen... According to the investigations of window opening percentage (WOP) of Shanghai in 2011, the WOP varies significantly from season to season and thus affects the air flow rate of natural ventilation rooms. A three-dimensional computional fluid dynamic(CFD) model was applied to simulating the flow fields in a street canyon under different wind speed and WOP. The numerical simulations show that WOP has a significant influence on the static pressure distribution of the downwind building. Therefore, a correction factor k can be used for calculating the flow rate of wind-driven natural ventilation. The results show that k ranges from 0.43 to 0.49 when WOP is 4.44%; when WOP increases to 9.78%, the correction factor k lies in 0.32 and 0.36. 展开更多
关键词 natural ventilation window opening percentage (WOP) correction factor numerical simulation
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部