The increasing flexibility of active distribution systems(ADSs)coupled with the high penetration of renewable distributed generators(RDGs)leads to the increase of the complexity.It is of practical significance to achi...The increasing flexibility of active distribution systems(ADSs)coupled with the high penetration of renewable distributed generators(RDGs)leads to the increase of the complexity.It is of practical significance to achieve the largest amount of RDG penetration in ADSs and maintain the optimal operation.This study establishes an alternating current(AC)/direct current(DC)hybrid ADS model that considers the dynamic thermal rating,soft open point,and distribution network reconfiguration(DNR).Moreover,it transforms the optimal dispatching into a second-order cone programming problem.Considering the different control time scales of dispatchable resources,the following two-stage dispatching framework is proposed.d dispatch uses hourly input data with the goal(1)The day-ahea of minimizing the grid loss and RDG dropout.It obtains the optimal 24-hour schedule to determine the dispatching plans for DNR and the energy storage system.(2)The intraday dispatch uses 15-min input data for 1-hour rolling-plan dispatch but only executes the first 15 min of dispatching.To eliminate error between the actual operation and dispatching plan,the first 15 min is divided into three 5-min step-by-step executions.The goal of each step is to trace the tie-line power of the intraday rolling-plan dispatch to the greatest extent at the minimum cost.The measured data are used as feedback input for the rolling-plan dispatch after each step is executed.A case study shows that the comprehensive cooperative ADS model can release the line capacity,reduce losses,and improve the penetration rate of RDGs.Further,the two-stage dispatching framework can handle source-load fluctuations and enhance system stability.展开更多
Bipolar direct current(DC)distribution networks can effectively improve the connection flexibility for renewable generations and loads.In practice,concerns regarding the potential voltage unbalance issue of the distri...Bipolar direct current(DC)distribution networks can effectively improve the connection flexibility for renewable generations and loads.In practice,concerns regarding the potential voltage unbalance issue of the distribution networks and the frequency of switching still remain.This paper proposes a day-ahead polarity switching strategy to reduce voltage unbalance by optimally switching the polarity of renewable generations and loads while minimizing the switching times simultaneously in the range of a full day.First,a multi-objective optimization model is constructed to minimize the weighted sum of voltage unbalance factors and the sum of number of switching actions in the day based on the power flow model.Second,a two-step solution strategy is proposed to solve the optimization model.Finally,the proposed strategy is validated using 11-node and 34-node distribution networks as case studies,and a switching and stabilizing device is designed to enable unified switching of renewable generations and loads.Numerical results demonstrate that the proposed strategy can effectively reduce the switching times without affecting the improvement of voltage balance.展开更多
Direct current(DC)bus voltage stability is essential for the stable and reliable operation of a DC system.If an oscillation source can be quickly and accurately localized,the oscillation can be adequately eliminated.W...Direct current(DC)bus voltage stability is essential for the stable and reliable operation of a DC system.If an oscillation source can be quickly and accurately localized,the oscillation can be adequately eliminated.We propose a method based on the power spectral density for identifying the voltage oscillation source.Specifically,a DC distribution network model combined with the component connection method is developed,and the network is separated into multiple power modules.Compared with a conventional method,the proposed method does not require determining the model parameters of the entire power grid,which is typically challenging.Furthermore,combined with a novel judgment index,the oscillation source can be identified more intuitively and clearly to enhance the applicability to real power grids.The performance of the proposed method has been evaluated using the MATLAB/Simulink software and PLECS RT Box experimental platform.The simulation and experimental results verify that the proposed method can accurately identify oscillation sources in a DC distribution network.展开更多
基金supported by Universiti Sains Malaysia through Research University Team(RUTeam)Grant Scheme(No.1001/PELECT/8580011)。
文摘The increasing flexibility of active distribution systems(ADSs)coupled with the high penetration of renewable distributed generators(RDGs)leads to the increase of the complexity.It is of practical significance to achieve the largest amount of RDG penetration in ADSs and maintain the optimal operation.This study establishes an alternating current(AC)/direct current(DC)hybrid ADS model that considers the dynamic thermal rating,soft open point,and distribution network reconfiguration(DNR).Moreover,it transforms the optimal dispatching into a second-order cone programming problem.Considering the different control time scales of dispatchable resources,the following two-stage dispatching framework is proposed.d dispatch uses hourly input data with the goal(1)The day-ahea of minimizing the grid loss and RDG dropout.It obtains the optimal 24-hour schedule to determine the dispatching plans for DNR and the energy storage system.(2)The intraday dispatch uses 15-min input data for 1-hour rolling-plan dispatch but only executes the first 15 min of dispatching.To eliminate error between the actual operation and dispatching plan,the first 15 min is divided into three 5-min step-by-step executions.The goal of each step is to trace the tie-line power of the intraday rolling-plan dispatch to the greatest extent at the minimum cost.The measured data are used as feedback input for the rolling-plan dispatch after each step is executed.A case study shows that the comprehensive cooperative ADS model can release the line capacity,reduce losses,and improve the penetration rate of RDGs.Further,the two-stage dispatching framework can handle source-load fluctuations and enhance system stability.
基金supported by Fundamental Research Funds for the Central Universities(No.2022CDJXY-007)。
文摘Bipolar direct current(DC)distribution networks can effectively improve the connection flexibility for renewable generations and loads.In practice,concerns regarding the potential voltage unbalance issue of the distribution networks and the frequency of switching still remain.This paper proposes a day-ahead polarity switching strategy to reduce voltage unbalance by optimally switching the polarity of renewable generations and loads while minimizing the switching times simultaneously in the range of a full day.First,a multi-objective optimization model is constructed to minimize the weighted sum of voltage unbalance factors and the sum of number of switching actions in the day based on the power flow model.Second,a two-step solution strategy is proposed to solve the optimization model.Finally,the proposed strategy is validated using 11-node and 34-node distribution networks as case studies,and a switching and stabilizing device is designed to enable unified switching of renewable generations and loads.Numerical results demonstrate that the proposed strategy can effectively reduce the switching times without affecting the improvement of voltage balance.
基金supported in part by the National Natural Science Foundation of China(No.51807112)。
文摘Direct current(DC)bus voltage stability is essential for the stable and reliable operation of a DC system.If an oscillation source can be quickly and accurately localized,the oscillation can be adequately eliminated.We propose a method based on the power spectral density for identifying the voltage oscillation source.Specifically,a DC distribution network model combined with the component connection method is developed,and the network is separated into multiple power modules.Compared with a conventional method,the proposed method does not require determining the model parameters of the entire power grid,which is typically challenging.Furthermore,combined with a novel judgment index,the oscillation source can be identified more intuitively and clearly to enhance the applicability to real power grids.The performance of the proposed method has been evaluated using the MATLAB/Simulink software and PLECS RT Box experimental platform.The simulation and experimental results verify that the proposed method can accurately identify oscillation sources in a DC distribution network.